Aeration System Opportunities Dave Reardon, PE, ENV SP HDR National Director - Water Sustainability WW/W Sustainable Energy Cohort-Session 5 January 31,

Slides:



Advertisements
Similar presentations
SPRINGETTSBURY TOWNSHIP.
Advertisements

Newcastle Water Pollution Control Plant
Metro Wastewater Reclamation District Digester Complex What works and what doesnt.
Welcome to American #2 Wastewater Treatment Plant.
CE 370 Sedimentation.
1 Seair Diffusion Systems Inc. Pulp & Paper Solutions June 2009.
INTRODUCTION TO THE TREATMENT OF TANNERY EFFLUENTS
Sewage and Effluent Treatment 2-4 November 2002 Seán Moran -The first few slides.
ENVE 420 Industrial Pollution Control EQUALIZATION Dr. Aslıhan Kerç.
Located in Exmoor National Park, with nearby bathing beach 3800 population equivalent (summer) 1900 m 3 /d flow to full treatment Sewage feed started 12th.
Treatment of Slaughterhouse Wastewater
Biological waste water treatment
An-Najah National University Civil Engineering Department
Nutrient Removal and Power Savings in Wastewater Treatment Systems
INTRODUCTION TO THE TREATMENT OF TANNERY EFFLUENTS
TEXAS COMMISSION on ENVIRONMENTAL QUALITY. PROPOSED STUCTURE FOR CHAPTER 217 < Subchapter A Administrative Provisions < Subchapter B Design Bases < Subchapter.
CTC 450 Review Secondary Treatment Trickling Filters Biological Towers
Municipal Wastewater Treatment Preliminary Seventh Power Plan Energy Efficiency Estimates October 14, 2014 West Point Wastewater Treatment Plant, Seattle.
A Review of State-of-the-Practice Equipment at the Plum Creek WWTP By Tim Grotheer Plum Creek Wastewater Authority & Dave Oerke RTW Professional Engineers.
Activated Sludge Plants: Dimensioning Eduardo Cleto Pires.
Municipal Wastewater Treatment Preliminary Seventh Power Plan Energy Efficiency Estimates November 18, 2014 West Point Wastewater Treatment Plant, Seattle.
Lower Moosa Canyon. Moosa Energy Savings Kilowatts hours used; ,000kWh ,000kWh ,000kWh ,000kWh ,000kWh ,000kWh(est.)
Municipal Wastewater Efficiency Improvements Potential Savings for the 6 th Power Plan September 30, 2008 Regional Technical Forum South Treatment Plant.
Energy Conservation by Optimizing Aeration Systems By Tom Jenkins, P.E. Dresser Roots, Inc. Vikram M. Pattarkine, Ph.D. Brinjac Engineering, Inc Michael.
Flotation Flotation involves separation of solids from the water phase by attaching the solids to fine air bubbles to decrease the density of the particles.
Fifteenth Annual Vail Operator Training Seminar Understanding Centrifugal Blower Operation in Wastewater Aeration and Dissolved Oxygen Control Presented.
Moving Bed Biofilm Reactor Retrofit for Ammonia and Nitrate Removal
1 IV. Wastewater Treatment technologies Topic IV. 9. Wastewater Treatment Facilities with Suspended Biomass - Aerated Tanks: Kinds, Structures, Basic Technological.
Pennsylvania Water Environment Federation PennTEC Annual Technical Conference June 4, 2013 Altoona Westerly Wastewater Treatment Facility BNR Conversion.
Overview of AIRE-O2 Triton® Technology
CSU Channel Islands Reclaimed Water use in Central Plant Jose Chanes Associate Director of Infrastructure and Energy Facilities Services.
Secondary Treatment Processes
Increasing Energy Efficiency at the Allegan WWTP MWEA/AWWA Joint Annual Conference August 19, 2010.
automation 4 me TYPES OF LOAD 1 automation 4 me CONSTANT TORQUE LOAD : PERCENT SPEED NOTE:- A CONSTANT TORQUE LOAD IS NOT NECESSARILY 100% LOAD TORQUE.
OXYGENATION Brian Vinci, Ph.D. Steven Summerfelt, Ph.D.
July 2013 TECHNICAL DIRECTOR ENVIRONMENTAL APPLICATIONS OF ACCELERATORS INDUSTRY CHALLENGES – SLUDGE TREATMENT MARTIN JOLLY.
Re-Commissioning of the Water Cooling System at Université de Sherbrooke Department of Buildings June 2008.
November 2004 Low Hanging Fruit Low Cost Energy Efficiency Opportunities in Cleanrooms.
DESIGN OF WASTEWATER TREATMENT PLANT
MEMBRANE BIOREACTORS AS - MBR Vs MBBR - UF EEC GLOBAL OPERATION By: C.S. Umre Technical Director.
1 Tom Jenkins JenTech Inc N. Elm Tree Road Milwaukee, WI Energy Saving Measures - 2.
Construction OF AMMONIA REMOVAL UPGRADES FOR FIRST BROAD RIVER WWTP
Flow Equalization 1.  To overcome operational problems caused by flowrate variations  To improve the performance of the downstream processes  To reduce.
Energy Efficiency Opportunities at Wastewater Treatment Facilities UW – Madison Class November 3, 2010 Focus on Energy Joseph Cantwell, P.E.
Energy Saving Measures - 1
CEE 426 October :05 PM UW Madison Room 1209 Engineering Hall
LOW D.O. OPERATION: EFFECTS ON BIOLOGICAL PHOSPHORUS REMOVAL, OXYGEN TRANSFER EFFICIENCY, DENITRIFICATION, AND ENERGY SAVINGS.
CEE 426 September :05 PM UW Madison Room _____ Engineering Hall Energy in Wastewater Treatment Plants Thomas E. Jenkins, P.E. 1.
Electricity | Natural Gas | Water | Wastewater Adding Whey for Denitrification Dale Adams, P.E Managing Engineer, Colorado Springs Utilities September.
1 JCI 1 1 Energy can be neither created nor destroyed, but only converted from one form to another. First Law of Thermodynamics Karl Friedrich Mohr In.
FLOTATION. INTRODUCTION Flotation is an operation that removes not only oil and grease but also suspended solids from wastewaters. Flotation is an operation.
© 2014 Evoqua Water Technologies LLC INTRODUCING THE CAPTIVATOR George Smith; Director of Biological Processes.
7/15/2002PP.AFD.09 1 of 43 Yaskawa Electric America Variable Frequency Drives In HVAC Applications.
OPERATIONAL OPTIMIZATION 2013 KY/TN WEA Management Conference M. Shannon Lambert, P.E. PRESENTED BY:
Kaeser Compressors, Inc.
Membrane Bioreactors for Wastewater Treatment.
CTC 450 Review WW Collection Systems Types of pipes Installation.
WATER MANAGEMENT.
5th Annual Water and Sanitation Workshop
Process & Equipment – ECM’s
Lecture Objectives: Learn about thermal storage systems
Application: 100PE to 10,000PE.
Modified Ludzack-Ettinger Wastewater Plant
Secondary Treatment Processes
Flow Equalization Jae K. (Jim) Park Dept. of Civil and Environmental Engineering University of Wisconsin-Madison.
Wastewater Treatment Dr.Gulve R.M..
Wastewater Facilities Upgrade Project
Wastewater Treatment Secondary Treatment.
City of Janesville Wastewater Facility Plan Amendment Public Hearing
Nitrogen Removal University of Kansas
Presentation transcript:

Aeration System Opportunities Dave Reardon, PE, ENV SP HDR National Director - Water Sustainability WW/W Sustainable Energy Cohort-Session 5 January 31, 2013

All Set for an Hour Discussion of Fine Bubble Diffusers, Turbo Blowers, and Dissolved Oxygen (DO) Control? Too Bad… You Will Be Disappointed

Presentation Agenda Loading to Aeration Basin Blowers Impacts of SRT and Selectors Sidestream Treatment Overdesign Take Away Points Blower Pressure, Ammonia Control, and ML Recycle

Improving Primary Clarifier Performance Can Make A Difference  Improved hydraulics and baffling can increase suspended solids (SS) removal by 10%  SS = BOD = Energy in activated sludge process What Would Happen if We Removed 95% of SS Prior to Aeration?

Much Has Been Said About Turbo Blowers

Blower Selection and Sizing is Critical Isentropic Efficiency (%) Capacity (%) Positive Displacement with VFD Multi-StageIGV Single-Stage Single-Stage Dual- Point Control and High-Speed Turbo Blowers

Make Alpha Work for You, Not Against You in Heavily Loaded Section of Aeration Basin Mechanical Aeration or Coarse Bubble Have Better Transfer Efficiency? Energy Saving Benefits of Denitrification - Rosso and Stenstrom (2007) Tank Length (%) Tank Length (feet) α Conventional Process Process with Anoxic Selector Anoxic Selector (α not defined)

Impact of MCRT on Oxygen Transfer Rosso and Stenstrom (2007) Field Oxygen Transfer Efficiency (Fouled Diffusers) Tank Length (m) ,000 Tank Length (feet) Conventional MCRT ~ 2 days Nitrifying MCRT > 10 days

What About Blower Header Operating Pressures?

Modification of Dissolved Oxygen (DO) Control System to Include Ammonia Control Blower Energy Reduction of 5 to 10% May Be Possible

Configuration of Aeration Basins Can Reduce Mixed Liquor Recycle Energy 75% Reduction in Mixed Liquor Recycle Energy and Less Equipment Primary Effluent Single Pass Aeration Basin Mixed Liquor Recycle Primary Effluent “Folded” Basin Mixed Liquor Recycle

Side Stream Treatment (Digester Centrate or Filtrate) Has Energy Advantages  Sidestreams are a high source of ammonia  100% reduction in carbon source required  Small footprint  50% reduction in energy Anammox Tower

Right Sizing and Proper Selection of Equipment Produces Large Energy Savings

We Don’t Need to Optimize Energy … We Have a Brand New Plant!

You Have Just Been Asked to Design an Activated Sludge Aeration System

Where is the Energy? Blowers!!

Peaking Factors for Overdesigned Blower Systems Avg Condition Worst Case Peak Factor Yearly: Peak Day versus Average Day BOD Diffuser Alpha (a) Peak Day versus Average Day Ammonia Diurnal: Maximum Hour versus Average BOD Design Year 2025 versus current Loads Ten States Standards versus Actual BOD Data This doesn’t even include the safety factor for temperature!

What’s the Bottom Line? A total safety (or peaking) factor of 5.7!

Blower Design Conditions Average Flow Conditions Now 5,000 cfm Air Flow Worst Case Future28,500 cfm

Three-Blower Installation Will Require 14,250 cfm Blowers Blower No. 1 14,250 cfm Blower No. 2 14,250 cfm Standby Blower 14,250 cfm 28,500 cfm

5,000 Multi-Stage Blower Has Surge Point at Approximately Percent of Design Capacity ,000 Flow (cfm) 15,000 Discharge Pressure (psi) Surge: 7,100 cfm Design: 14,250 cfm at 8 psi 0

Unit Power Consumption on Multi- Stage Centrifugal Blowers Increases at Throttled Conditions HP/1,000 cfm Percent of Design Flow Constant Discharge Pressure

Blower Power Consumption HP Percent of Design Flow F, 36 0 RH, 5000 SCFM Blower 25      Single Stage, Inlet Guide Vanes, Outlet Diffusion Vanes Multi-Stage VFD Multi-Stage, Inlet Throttling  High Speed Turbo Blower

What Should You Do? Blower No. 1 8,000 cfm Blower No. 2 8,000 cfm Blower No. 3 14,250 cfm Blower No. 4 14,250 cfm OR Blower No. 1 8,000 cfm Blower No. 2 14,250 cfm Blower No. 3 14,250 cfm Blower No. 4 14,250 cfm

It’s Becoming Quite Fashionable to Combine Blower Types 14,250 cfm 8,000 cfm Two Single-Stage Two Multi-Stage

Channel Aeration Overdesign is Common 5 cfm/foot channel

Don’t Scrimp on Adding Equipment that Will Optimize Energy at Average Conditions $2.3 Million $100, hp Blower Capital Cost Energy (20 years)

Your Overdesign Repellant  Equipment operates at “worst case” conditions < 5 percent of the time  Most designs are specified to be efficient at worst case conditions  Equipment is often unstable, inefficient at average/minimum conditions

Your Overdesign Repellant (cont’d)  Use “jockey” pumps, blowers for minimum, average conditions  Kick your consultant in the behind! Ask about operation without all the safety factors

Your Take Away Points  Efficient aeration design is much more than blowers and fine bubble diffusers  Reduced loading on aeration basins  Conduct sustainability reviews of aeration systems and other processes  Overdesign must be avoided Challenge Your Consultants!

Aeration System Opportunities Dave Reardon, PE, ENV SP HDR National Director - Water Sustainability (916)