Material Measurement Lab Material Measurement Laboratory Q. Dong; M. Lorna A. De Leoz; L.E. Kilpatrick; Y. Liang; X. Yan; X. Yang; S.E. Stein Building.

Slides:



Advertisements
Similar presentations
Genomes and Proteomes genome: complete set of genetic information in organism gene sequence contains recipe for making proteins (genotype) proteome: complete.
Advertisements

Protein Quantitation II: Multiple Reaction Monitoring
Improvements in Mass Spectrometry for Life Science Research – Does Agilent Have the Answer? Ashley Sage PhD.
In-depth Analysis of Protein Amino Acid Sequence and PTMs with High-resolution Mass Spectrometry Lian Yang 2 ; Baozhen Shan 1 ; Bin Ma 2 1 Bioinformatics.
MN-B-C 2 Analysis of High Dimensional (-omics) Data Kay Hofmann – Protein Evolution Group Week 5: Proteomics.
N-Glycopeptide Identification from CID Tandem Mass Spectra using Glycan Databases and False Discovery Rate Estimation Kevin B. Chandler, Petr Pompach,
How to identify peptides October 2013 Gustavo de Souza IMM, OUS.
PepArML: A model-free, result-combining peptide identification arbiter via machine learning Xue Wu, Chau-Wen Tseng, Nathan Edwards University of Maryland,
Proposal for a Standard Representation of the Results of GC-MS Analysis: A Module for ArMet Helen Fuell 1, Manfred Beckmann 2, John Draper 2, Oliver Fiehn.
Building and Using Libraries of Peptide Ion Fragmentation Spectra S.E. Stein, L.E. Kilpatrick, M. Mautner, P. Neta, J. Roth National Institute of Standards.
Lawrence Hunter, Ph.D. Director, Computational Bioscience Program University of Colorado School of Medicine
LC/MS WORKSHOP IOWA STATE UNIVERSITY Kamel Harrata  Instrument Description  Data Acquisition  Data Processing.
Proteomics Informatics – Protein identification II: search engines and protein sequence databases (Week 5)
Proteomics Informatics Workshop Part I: Protein Identification
Previous Lecture: Regression and Correlation
HOW MASS SPECTROMETRY CAN IMPROVE YOUR RESEARCH
FIGURE 5. Plot of peptide charge state ratios. Quality Control Concept Figure 6 shows a concept for the implementation of quality control as system suitability.
Material Measurement Laboratory Mass Spectral Database of Glycans and Glycopeptides in Therapeutic Drugs Maria Lorna A. De Leoz, Xinjian (Eric) Yan, Xiaoyu.
My contact details and information about submitting samples for MS
Proteomics Informatics (BMSC-GA 4437) Course Director David Fenyö Contact information
Spectral Counting. 2 Definition The total number of identified peptide sequences (peptide spectrum matches) for the protein, including those redundantly.
Proteomics Informatics Workshop Part III: Protein Quantitation
Proteomics Informatics Workshop Part II: Protein Characterization David Fenyö February 18, 2011 Top-down/bottom-up proteomics Post-translational modifications.
Evaluated Reference MS/MS Spectra Libraries Current and Future NIST Programs.
Tryptic digestion Proteomics Workflow for Gel-based and LC-coupled Mass Spectrometry Protein or peptide pre-fractionation is a prerequisite for the reduction.
Mass Spectrometry Mass spectrometry (MS) is not true “spectroscopy” because it does not involve the absorption of electromagnetic radiation to form an.
MS/MS Libraries of Identified Peptides and Recurring Spectra in Protein Digests Lisa Kilpatrick, Jeri Roth, Paul Rudnick, Xiaoyu Yang, Steve Stein Mass.
Acknowledgements This work is supported by NSF award DBI , and National Center for Glycomics and Glycoproteomics, funded by NIH/NCRR grant 5P41RR
Common parameters At the beginning one need to set up the parameters.
1 Chemical Analysis by Mass Spectrometry. 2 All chemical substances are combinations of atoms. Atoms of different elements have different masses (H =
Outline Selection of candidate proteins for the multiplex analysis of DBS via targeted proteomics The currently employed strategies for the selection.
Analysis of Complex Proteomic Datasets Using Scaffold Free Scaffold Viewer can be downloaded at:
Laxman Yetukuri T : Modeling of Proteomics Data
Poster produced by Faculty & Curriculum Support (FACS), Georgetown University Medical Center Application of meta-search, grid-computing, and machine-learning.
A Reference Library of Peptide Ion Fragmentation Spectra: Yeast S.E. Stein, L.E. Kilpatrick, P. Neta, Q.L. Pu, J. Roth, X. Yang National Institute of Standards.
Proteomics What is it? How is it done? Are there different kinds? Why would you want to do it (what can it tell you)?
Glycoprotein Microheterogeneity via N-Glycopeptide Identification Kevin Brown Chandler, Petr Pompach, Radoslav Goldman, Nathan Edwards Georgetown University.
A Reference Library of Peptide Ion Fragmentation Spectra Stephen Stein 1 ; Lisa Kilpatrick 2 ; Pedatsur Neta 1 ; Jeri Roth 1 ; Xiaoyu Yang 1 National Institute.
Multiple flavors of mass analyzers Single MS (peptide fingerprinting): Identifies m/z of peptide only Peptide id’d by comparison to database, of predicted.
Eat Raw & Fresh: Introducing isotopic Mass-to-charge Ratio and Envelope Fingerprinting (iMEF) and ProteinGoggle for Protein Database Search Zhixin(Michael)
Overview of Mass Spectrometry
EBI is an Outstation of the European Molecular Biology Laboratory. In silico analysis of accurate proteomics, complemented by selective isolation of peptides.
Separates charged atoms or molecules according to their mass-to-charge ratio Mass Spectrometry Frequently.
Isotope Labeled Internal Standards in Skyline
Proteomics Informatics (BMSC-GA 4437) Instructor David Fenyö Contact information
Poster produced by Faculty & Curriculum Support (FACS), Georgetown University Medical Center Application of meta-search, grid-computing, and machine-learning.
Salamanca, March 16th 2010 Participants: Laboratori de Proteomica-HUVH Servicio de Proteómica-CNB-CSIC Participants: Laboratori de Proteomica-HUVH Servicio.
Metabolomics MS and Data Analysis PCB 5530 Tom Niehaus Fall 2015.
Oct 2011 SDMBT1 Lecture 11 Some quantitation methods with LC-MS a.ICAT b.iTRAQ c.Proteolytic 18 O labelling d.SILAC e.AQUA f.Label Free quantitation.
Application of meta-search, grid-computing, and machine-learning can significantly improve the sensitivity of peptide identification. The PepArML meta-search.
Deducing protein composition from complex protein preparations by MALDI without peptide separation.. TP #419 Kenneth C. Parker SimulTof Corporation, Sudbury,
Material Measurement Lab Material Measurement Laboratory Mass Spectrometry Data Center Biomolecular Measurement Division Q. Dong; M. Lorna A. De Leoz;
Geranyl acetate C12H20O2. Mass Spectral Libraries An Ever-Expanding Resource for Chemical Identification Steve Stein Mass Spectrometry Data Center National.
Proteomics Informatics (BMSC-GA 4437) Course Directors David Fenyö Kelly Ruggles Beatrix Ueberheide Contact information
Constructing high resolution consensus spectra for a peptide library
Protein quantitation I: Overview (Week 5). Fractionation Digestion LC-MS Lysis MS Sample i Protein j Peptide k Proteomic Bioinformatics – Quantitation.
Introduction to Liquid Phase Mass Spectrometry
Computational Challenges in Metabolomics (Part 1)
Finding the unexpected in SWATH™ Data Sets – Implications for Protein Quantification Ron Bonner; Stephen Tate; Adam Lau AB SCIEX, 71 Four Valley Drive,
Target Analyses in Parallel Reaction Monitoring Mode (PRM)
MS Libraries for Forensics: DART-MS and GC-MS
Metabolomics Part 2 Mass Spectrometry
Database Search Algorithm for Identification of Intact Cross-Links in Proteins and Peptides Using Tandem Mass Sepctrometry 신성호.
Mass Spectrometry makes it possible to measure protein/peptide masses (actually mass/charge ratio) with great accuracy Major uses Protein and peptide identification.
LC-MS/MS Identification of Impurities Present in Synthetic Peptide Drugs Dr Anna Meljon*, Dr Alan Thompson, Dr Osama Chahrour, and Dr John Malone Almac.
Bioinformatics Solutions Inc.
Proteomics Informatics David Fenyő
Metabolomics: Preanalytical Variables
Proteomics Informatics –
Proteomics Informatics David Fenyő
Presentation transcript:

Material Measurement Lab Material Measurement Laboratory Q. Dong; M. Lorna A. De Leoz; L.E. Kilpatrick; Y. Liang; X. Yan; X. Yang; S.E. Stein Building a Comprehensive Reference Tandem MS Library of Peptides, Glycans and Glycopeptides for Therapeutic Antibodies

Material Measurement Lab Content NIST-evaluated spectra for 212,961 compounds Accompanying chemical name(s) and identifiers Chemical structures and retention information Validated software for spectrum matching The NIST/EPA/NIH Mass Spectral Library (SRD1A) The NIST/EPA/NIH Mass Spectral Library (SRD1A) Reference Standard Mass Spectra for Chemical Identification Fragments of charged molecules provide reproducible, discriminating fingerprints for molecules in complex mixtures in: Usage World’s most widely used MS library >5,000 NEW installations per year Integrated into instrument vendor software systems Common element in GC-MS ‘gold standard’ identifications Environmental Analysis Medical Research Homeland Security Forensics Chemical Manufacturing Food Analysis Biomolecular Measurement Division

Material Measurement Lab Ion Fragmentation is Reproducible O’Neal et al. Anal. Chem NIST 2012 A mass spectrum is an energy-dependent property of an ion Hexadecane

Material Measurement Lab

# Precursor Ions NIST Tandem Mass Spectral Library 2012 Fragmentation Type Precursor Ions Ion Trap >10,000 Beam Collision Cell (QTOF, QQQ, HCD) >8,000 Classes: Metabolites, Drugs, Sugars, Phospholipids, Peptides, Surfactants, Pesticides, etc. Precursors: [M+H] +, [M+2H] 2+, [M­-H]- ­, [M+Na] +, [M+NH4] +, [Cat] +, [An]- ­, [p-H2O], [p-­NH3], etc. New Software Features: Exact or isotopic precursor mass & fragment ions. Formats: mzXML, mzData, mgf, msp, dta, pkl, JCAMP, …. Compatible with NIST EI & Peptide Tandem Libraries. New methods for finding targets in the presence of noise. New Scoring: Compounds with few dominant peaks. Compensates for m/z tuning errors. Compounds7,020 Precursor Ions15,517 Spectra123,781

Material Measurement Lab Ion Trap & Collision Cell Spectra HCD/Orbi 45 eV Ion Trap TKPREEQY N STYR

Material Measurement Lab 58eV 65eV 72eV [M+2Na] 2+ Energy Dependence Collision Energy

Material Measurement Lab Content Spectra for 8 species, including human 324,352 human peptide ions (24% coverage of human proteome) compiled from >30M replicates Validated software for spectrum matching NIST Library of Peptide Ion Fragmentation spectra (SRD1C) NIST Library of Peptide Ion Fragmentation spectra (SRD1C) Reference Standard tandem Mass Spectra for peptide and protein measurements Usage Most widely used peptide tandem MS database Freely distributed and accessible on the web Integrated into Thermo Scientific TM Proteome Discoverer software Compatible with many open-source projects Biomedical Research Protein Identification Characterization of Protein Modifications Bio-manufacturing Homeland Security Biomolecular Measurement Division

Material Measurement Lab Peptide Library Pipeline Raw Data Translate, Annotate XTandem Prospector OMSSA Comet Integrate, Class FDR Consensus Spectrum Library Build Library

Material Measurement Lab peptide.nist.gov NISTMSQC: Full Analysis of LC-MS/MS data Library/quality metrics “Performance Metrics for Liquid Chromatography-Tandem Mass Spectrometry Systems in Proteomics Analyses”, Molecular & Cellular Proteomics, 9, 225, 2010

Material Measurement Lab NIST Mass Spectral Libraries NIST/EPA/NIH Mass Spectral Library EI spectra of 212K compounds Peptide Library 500,000 peptides for 8 species Small Molecule Tandem MS 7,020 compounds Ion Trap/Collision Cell IgG Library with NIST reference material glycans glycopeptides peptides intact & large fragments?

Material Measurement Lab Why Libraries? Contain ‘fingerprints’ of previously identified components in a sample (digest) – Store, organize, annotate, extend and re-identify Identify all known components – Independent of settings Length, MCs, charge, protease, modification, … – More reliable (use peak intensities and priors) Common resource among different labs – Data standard

Material Measurement Lab David M. Hambly, Douglas D. Banks, Joanna L. Scavezze, Christine C. Siska, and Himanshu S.G Anal. Chem. 2009, 81, 7454–7459 Detection and Quantitation of IgG 1 Hinge Aspartate Isomerization: A Rapid Degradation in Stressed Stability Studies UV intensities MS masses

Material Measurement Lab Challenges with Improvements in Instrument Performance With increase in sensitivity and mass accuracy/resolution: – More components with increasing detail revealed Document in library – view and re-use All components may be ‘annotated’ – What are they? Are they significant? “Truth in Labeling” Libraries can hold this information in reusable format

Material Measurement Lab Single Protein Digest Library All identifiable, recurring products in the digest of 1 protein Peptides – Use available MS ‘sequencing’ methods for tentative IDs – Employ wide range of digestion conditions – Apply filters to reject ‘homologies’ – For each peptide store: Spectrum (ion trap and collision cell fragmentation) Occurrence frequencies, intensity, retention Glycopeptides – Identify by Oxonium and Loss-Patterns - then extract Glycans – From known samples: See Poster (Lorna De-Leoz)

Material Measurement Lab Start with Human Serum Albumin (HSA)

Material Measurement Lab Single Protein Digest Pipeline Raw Data Translate, Annotate XTandem Prospector OMSSA Comet Integrate, Class FDR Consensus Spectrum Six Filters Library Build Library InSpect TagRecon MS1, MS2, RT

Material Measurement Lab Six Filters FilterData TypeDescriptionRejection Threshold 1 Peptide classPeptide identityLow prior probability >= two or more unusual classes 2 Ion SignificanceMS1 Median relative abundance and peptide ion identification frequency, PIF PIF ≤ m/z ErrorMS1Median m/z deviation >=0.25 m/z for LTQ >=5 ppm for Orbitrap 4 Unidentified Fragment Ions MS2 Unidentified fraction of all and top 20 abundances and number of peaks Overall Score >= 0.28 Intensity Only Score >= Sufficient Ions Above the Precursor m/z MS2 Fraction of ions and abundance above precursor m/z Fraction of ions * fraction of abundance above the precursor m/z <=0.1 6 Unexpected Charge State Ion charge Number of basic units, NBU vs charge state, CS |NBU-CS|>0

Material Measurement Lab Biological Modifications Methionine Oxidation – ETYGEMADCCAK Cysteinylation – ALVLIAFAQYLQQCPFEDHVK Phosphorylation – TCVADESAENCDK Acetylation – LKCASLQK

Material Measurement Lab Some Analytical Modifications Methionine Oxidation – ETYGE M ADCCAK Glutamine Deamination – QTALVELVK Pyro-carbamidomethyl – C CTESLVNR Underalkylation – C C TESLVNR Overalkylation – LVNEVTEFAK Transpeptidation – TPVSDR R Iron – AAF TE CCQAADK Sodiation – LVN E VTEFAK Carbamylation – S LHTLFGDK Tris-derived N-term (=70) – Method/Sample Dependent

Material Measurement Lab Indigestible Peptides Hyper-missed cleavage peptides – DVFLGMFLYEYARRHPDYSVVLLLRLAKTYETTLEK/4+ – NYAEAKDVFLGMFLYEYARRHPDYSVVLLLR/4+ – QNCELFEQLGEYKFQNALLVRYTKKVPQVSTPTLVEVSR/5+ Formed quickly, not affected by digestion time

Material Measurement Lab IgG Modifications Large-Scale Identification and Quantification of Covalent Modifications in Therapeutic Proteins – “In an LC/MS/MS analysis of a tryptic digestion of an IgG2 mono-clonal antibody, 1712 peptide ions … and 227 modifications were identified …” Zhongqi Zhang, Anal. Chem. 2009, 81, 8354–8364 From protein and processing – Most from processing

Material Measurement Lab IgG Tryptic Peptide Libraries Six Commercial Drugs – 1 Constant Region, Individual Variable Region Libraries Cetuximab Example – Spectra for 975 Different Ions – 156 Simple Tryptics – 175 Modifications – 200 ‘In-sample’ Semitryptics – 169 ‘In-source’ Semitryptics – 101 Unexpected Missed Cleavage – 41 Under-/Over-alkylation – 133 Unidentified Modifications

Material Measurement Lab Cetuximab Modifications ModificationSiteDifferent Ions CarbamylN-term, K32 OxidationM, H, W27 Cation:NaD, E25 Gln->pyro-GluQ at N-term12 Cation:CaD, E12 FormylN-term, K, S, T10 DehydrationD8 Pyro-carbamidomethylC at N-term7 TranspeptidationArg and Lys at N or C-term6 Glu->pyro-GluE at N-term2 DeamidationN, Q2

Material Measurement Lab IgG Digest Peptides Annotation FNW(O)YVDGVEVHNAK/3+ Library Consensus Spectrum

Material Measurement Lab Glycopeptide Features NEUTRAL MONOSACCHARIDE LOSSES OXONIUM IONS TheoryOur addition m/z m/z m/z m/z m/z m/z m/z m/z (2H 2 O+CH 2 O) m/z H 2 O m/z H 2 O Oxonium ion peaks Threshold: ~60ppm Neutral Losses Threshold: ~20ppm All z=2 35eV HCD MS 2 Hexose N-acetylhexosamine Deoxyhexose (e.g. fucose)Sialic Acid (e.g. NeuAc)

Material Measurement Lab “Proteomics” Minor Constituents, Digest Quality Glycopeptide Peptide Sampled/No ID Unsampled

Material Measurement Lab

Vary Digestion Conditions

Material Measurement Lab Other Proteases

Material Measurement Lab Starter Glycan MS/MS Library NGA4 2 G0 NGA2F 1 G0F NGA3B 1,2 G0B NA2G1F 1 G1F A1F 1 G2FS NA2F 1 G2F A2F 1 G2FS2 NGA2B 2 G0B NGA2 1 G0 NGA4B 2 G0B 1 Purchased; 2From the Consortium for Functional Glycomics through Dr. Jim Paulson Typical Precursor ions  [M+2H] 2+  [M+H+K] 2+  [M+H+Na] 2+  [M+2Na] 2+ Additional precursor ions for sialylated glycans  [M+2Na-4H] 2-  [M+K-3H] 2-  [M-2H] 2-  [M+Na+K-4H] 2- Fragmentation Methods  Ion Trap (Resonant)  ‘HCD’ at 12 energies (5-70eV)

Material Measurement Lab Rituximab Glycan Library Head to Tail Comparison G LYCAN G0F FOUND IN R ITUXIMAB S AMPLE

Material Measurement Lab SRD Standard Reference Materials – Target Analytes (Cholesterol, Vitamin D) Often in Matrix (urine, plasma, …) – Whole Materials (Plasma Metabolites, …) Identify and value-assign many components Standard Reference Data – MS Library, Thermodynamic Data, Chemistry Webbook, … Standard Reference Materials + Data – Whole material + Data + Libraries SRD + SRM SRM/D

Material Measurement Lab SRM/D - Metabolites in PlasmaFuture: SRM/D IgG

Material Measurement Lab NIST MS Data Center Lab Computer