Autoclaves Nadina Wiórkiewicz (2011), Small benchtop laboratory autoclave [photograph]. Retrieved from https://commons.wikimedia.org/wiki/File:Laboratory_autoclave.jpg.

Slides:



Advertisements
Similar presentations
ONLINE self-study Autoclave.
Advertisements

Biological Hazards Routes of Entry
Biological Laboratory Safety. REHS Rutgers Environmental Health and Safety REHS supports Rutgers University by providing comprehensive and professional.
DECONTAMINATION AND DISPOSAL Prepared by; Syazwani Mahmad Puzi School of Biorocess Engineering UniMAP.
Autoclave Training Guide York University Department of Occupational Health and Safety Suite C, East Office Building, 4700 Keele St. Telephone :
DEPARTMENT OF HEALTH RESEARCH INSTITUTE FOR TROPICAL MEDICINE LABORATORY DECONTAMINATION and WASTE MANAGEMENT.
Emergency Response to Biological Incidents Response to Biological Spills in the Laboratory (Intentional or Accidental)
Annual Refresher Training. Preliminary Procedure in Glassware Washing Contaminated items. Return glassware that contains chemicals or contamination to.
These guidelines are in place for the safety of the personnel and animals in the facility and the environment at large and have been reviewed and endorsed.
Prepared by; Miss Syazwani Mahmad Puzi School of Bioprocess Engineering UniMAP.
Fundamentals of Nursing Care: Concepts, Connections, & Skills Copyright © 2011 F.A. Davis Company Chapter 22 Surgical Asepsis.
Onsite Biomedical Waste Management Environmental Health & Safety Environmental Protection Program
Infectious Waste Management. Types of Waste 1.Infectious Laboratory Waste 2. Pathological (biomedical) Waste 3.Broken Glass 4.Other “Objectionable” Wastes.
How to Manage Biohazardous Waste in Laboratories
Laboratory Biohazardous/Sharps Waste Management. Types of Biohazardous Waste Dry Solid- No pourable liquids! Dry Solid- No pourable liquids! –Contaminated.
University of Alaska Fairbanks Environmental Health, Safety, & Risk Management Laboratory Sharps: Handling and Disposal November
Safe Handling of Infectious Waste Procedure Overview.
3.03 Understand support services
Sterilization 4-H Veterinary Science Extension Veterinary Medicine Texas AgriLife Extension Service College of Veterinary Medicine and Biomedical Science.
Uses common terminology required in your veterinary practice Explain in detail, what is happening in the photo.
Autoclave Use and Safety
Micro Practical 3 PRINCIPLE AND WORKING OF AUTOCLAVE Dr. Shahzad Ali Assistant Professor Department of Wildlife and Ecology UVAS, Ravi Campus, Pattoki.
CSULB Department of Biological Sciences Common Use Equipment Training Autoclaves.
Autoclave Training Guide University of Windsor Chemical Control Centre Health and Safety B37 Essex Hall. Telephone : ext
Environmental Health & Safety Medical Waste Management for Custodians.
F.Y.I. The most common way for crime-scene personnel to become exposed to infectious blood borne pathogens, is through injuries involving sharps (needles,
Autoclave. What is an Autoclave? Autoclave is a pressurized device designed to heat aqueous solutions above their boiling point at normal atmospheric.
FLASHTITE INSTRUCTIONS FOR USE Copyright 2010 © Case Medical Inc.
7. EMERGENCY RESPONSE RYERSON UNIVERSITY.
Infection Control.
Aseptic Technique: Media and Equipment. Growth Medium A growth medium or culture medium is a liquid or gel designed to support the growth of microorganisms.
Clean UpEquipment/ Materials Safety Equipment Glass, Food, and Drink Accidents 100.
Lab Specific Training June 14 th, Responsibilities completing all required safety training; reading the Lab Safety Plan and all lab standard operating.
May 7 th,  There’s a direct link to it from the Shimizu Lab Website or go to  All personnel are responsible for.
$1 Million $500,000 $250,000 $125,000 $64,000 $32,000 $16,000 $8,000 $4,000 $2,000 $1,000 $500 $300 $200 $100 Welcome.
Lab safety rules practical NO (1) Dalia Kamal Eldien Mohammed.
Lab SAFETY. Laboratory Safety Rap! eo.php?video_id=
CHAPTER 6 Microbiology-Related Procedures
CSULB Department of Biological Sciences Common Use Equipment Training
Chemical Sterilization
Laboratory safety rules Dalia Kamal Eldien Mohammed Practical NO (1)
ASEPTIC TECHNIQUE IN HEALTHCARE. MICROBIAL GROWTH FOLLOWING FACTORS INFLUENCE MICROBIAL GROWTH: TEMPERATURE PH, OR THE VALUES USED IN CHEMISTRY TO EXPRESS.
Hazardous and Infectious Waste. Managing hazardous waste Hazardous waste includes chemicals and biological materials Disposal of waste in the health care.
Handling and Disposal of Infectious Wastes
SteriTite Instructions for use
Autoclave Training November 16, 2005 University of Kentucky Department of Biosafety.
Standard Operating Procedure for the Disposal of Sharp Objects in Laboratories.
Onsite Medical Waste Management and Bloodborne Pathogens
Biological Waste from Laboratories
3.03 Understand support services PP2
洗手及 负压技术 余 波
Laboratory equipment Lecture (5).
3.03 Understand support services
Needlestick and Sharps Training
Practical Medical Bacteriology
November 16, 2005 University of Kentucky Department of Biosafety
3.03 Understand support services
Infection Control Lesson 3: Surgical Asepsis
Sterilization process
Lab Safety Unit 1 Lesson 2.
3.03 Understand support services
Instructions for Wipe Testing for Radioactive Material Contamination
3.03 Understand support services PP2
Safety Moments Topic: Handling Waste
3.03 Understand support services
Sterile Technique.
Microbiology-Related Procedures
3.03 Understand support services
Laboratory equipment Lecture (9).
3.03 Understand support services
Presentation transcript:

Autoclaves Nadina Wiórkiewicz (2011), Small benchtop laboratory autoclave [photograph]. Retrieved from https://commons.wikimedia.org/wiki/File:Laboratory_autoclave.jpg

Learning Objectives What materials can be autoclaved? What Personal Protective Equipment (PPE) is necessary for autoclave use? How does one properly load the autoclave? What steps assist in efficient decontamination of biohazardous waste? How does one verify autoclave performance for decontamination of biohazardous waste? Skeet, M., & Fear, D. (1995). Care and safe use of hospital equipment (p. 90). London: VSO.

Importance of Proper Autoclave Use Tremendous pressure from steam in chamber provides explosive potential High temperatures and presence of extremely hot water creates potential for burns and scalding Inadequate decontamination allows for the potential of biological hazards and personnel and environmental contamination Note: burning is the most common form of biowaste disposal in the developing world

What can be autoclaved? Surgical Instruments Glassware Plastic tubes and pipette tips Solutions and water Animal food and bedding Waste آرمین (2012), Surgical instruments [photograph]. Retrieved from https://commons.wikimedia.org/wiki/File:Surgical_instruments_02.JPG Pocar19 (012), Gilson Pipette Tip [photograph]. Retrieved from https://en.wikipedia.org/wiki/File:Gilson_pipette_tip.jpg Lilly_M (2011), Glass beakers [photographs]. Retrieved from https://commons.wikimedia.org/wiki/File:Glass_beakers-set.jpg

Types of waste Waste Type Container What You Need To Do Biological Infectious Waste Orange or clear autoclave bag Autoclave Medical Waste Biological Infectious Waste which cannot be autoclaved Red incineration bag in red waste container Medical Center- close and place by trash in lab for pick-up, Outside Medical Center- contact Environmental Management for pick-up Sharps- All needles, syringes, scalpels, blades, and all other sharp medical waste Sharps container Animal Carcasses- no biological, chemical, or radiological hazard Opaque bag Return to appropriate DLAR location Animal Carcasses- intentionally infected Red incineration bag Incinerate (Medical Center or call Environmental Management pick-up) Used Biological Culture Media Glass or plastic Disinfect with bleach or autoclave

Principles of Autoclave Operation Steam penetrates objects in the autoclave 121 °C (249°F) Condensation creates negative pressure and draws in additional steam Moist heat kills microorganisms via coagulation of proteins Two types of autoclaves Gravity Displacement Vacuum Assisted

Gravity Displacement Snelling, Guy. “Autoclave Validation-What is Really Required?.” Retrieved from: http://www.frankshospitalworkshop.com/equipment/documents/ autoclaves/background/Autoclave_validation_-_what_is_really_required.pdf

Autoclave Use Basics Personal Protective Equipment (PPE) Packaging Loading Operating User logs Maintenance logs Unloading Improper Autoclave Practices Nadina Wiórkiewicz (2011), Small benchtop laboratory autoclave [photograph]. Retrieved from https://commons.wikimedia.org/wiki/File:Laboratory_autoclave.jpg

PPE for Autoclave Users Eye Protection Lab Coat, Buttoned Closed-toed Shoes Heat-resistant Gloves Lilly_M (2011) Laboratory protection goggles [photograph]. Retrieved from https://commons.wikimedia.org/wiki/File:Laboratory_protection_goggles-blue.jpg Public Domain Pictures (2014), Retrieved from Pixabay

Packaging for Autoclaving Be sure the material should be autoclaved No volatile chemicals, sharps, red bag waste, radioactivity Utilize containers and autoclave bags appropriate for autoclaving Clear or orange bags UK Stores 6532-0046    Do not overfill containers Tom Beatty (2012), Autoclaves [photograph]. Retrieved from https://www.flickr.com/photos/northcoastoutfitters/8291521701

Packaging for Autoclaving Carefully add water to autoclave bags Add approximately 1 liter of water to 24” x 30” bag Aids in reaching appropriate temperature quickly Creates steam in the autoclave bag to replace cold air Prepare packaging to allow steam penetration Check that all containers including bags are vented Loosely close autoclave bags Vent lids on bottles containing solutions Place packaged material in a secondary container Stainless steel tray or autoclavable polypropylene bin

Loading the Autoclave Load material to allow efficient steam penetration Autoclave clean items and waste separately Do not allow material to be autoclaved to touch the sides or top of the chamber Nadina Wiórkiewicz (2011) Laboratory autoclave [photograph]. Retrieved from: https://commons.wikimedia.org/wiki/File:Laboratory_autoclave.jpg

Operating the Autoclave Be sure the autoclave is functioning properly before use Record information in User Log Close door properly and securely Choose the correct conditions for your material For decontamination: Temperatures between 121-124°C Total processing time 60-120 minutes Exposure time greater than 20 minutes Pressure minimum 15 PSI Select liquid cycle or slow exhaust cycle ONLY use destined water!!! Clean with vinegar every day

Autoclave User Log Complete User Log with Every Use Maintain User Logs for Two Years Complete User Log with Every Use

Autoclave Maintenance Log Maintain Maintenance Logs for Five Years Complete Maintenance Log for Every Repair Maintain records of Yearly Calibration

Unloading the Autoclave Put on Personal Protective Equipment Allow the autoclave to completely finish cycle Pressure gauge must read zero Verify cycle conditions were met Open door slightly to allow steam to escape Allow contents to cool before removal Carefully remove items Be especially careful with fluids and plastic bins

Improper Autoclave Practices MFERMION (2014), Biomedical Waste [photograph]. Retrieved from https://commons.wikimedia.org/wiki/File:Biomedical_waste.jpg

Common Problems Build up of a scale due to the use of non-distilled water Scale may cause the air release valve and the over-pressure relief valve to be clogged Soaking them for several days in pure distilled water should dissolve any deposits Hissing noise due a leak in the pressure vessel or valve Leaky door seal Thermostat

Autoclave Verification Program Program will ensure that all potentially hazardous biological waste is properly decontaminated prior to deposition in landfill Program requires testing of the ability of campus autoclaves to kill microorganisms There are over 50 autoclaves on campus which require this verification program

Autoclave Verification Each Load of Biohazardous Waste Autoclaves with automatic documentation Review the printed report If conditions were met, initial, date, and place User Log number on printed report If conditions were not met, do not remove the load, repeat autoclave cycle. If conditions are not met again, autoclave must be labeled out of order. Contact responsible individual posted on autoclave. Responsible individual contacts service company to schedule repairs.

Autoclave Verification Each Load of Biohazardous Waste Autoclaves without automatic documentation A Chemical Integrator Test Pack (CITP) must be incorporated in each load. Based on color change the performance of the autoclave will be evaluated. Tape the autoclaved CITP strip in the appropriate section of the User Log for your load.

Autoclave Verification Monthly Verification for Biological Waste Autoclaves Biological Indicator Test Checks all conditions of autoclave cycle, time, temperature, and pressure Verifies ability of autoclave to kill a microorganism Utilize the 3M Attest Biological Indicator Monitoring Kit Record results in Biological Indicator Results Log

Biological Indicator Results Log Maintain Results Logs for Five Years Complete Results Log with Every Monthly Test

Chemical Indicators These indicators change color after being exposed to specific temperatures. There are two types of chemical indicators, temperature sensitive tape (autoclave tape) and integrated chemical indicator strips. Autoclave tape can only attest to the temperature attained and not to exposure time and hence success of sterilization. Integrated chemical indicator strips however, provide a limited validation of temperature and time, though this is not as accurate as a Biological Indicator, and so it cannot be used as a replacement.

Biological Indicator Test Procedure Label Attest package containing biological indicator vial with date, autoclave ID, and load number from user log Place the indicator vial package in the autoclave with the biohazard waste load Run the autoclave cycle as usual Using proper unloading procedures, remove the indicator package from the autoclave

Biological Indicator Test Procedure Label the indicator vial with all information from package Check indicator vial label for color change from rose to brown Place the biological indicator vial into the 56°C incubator for 24-48 hours

Biological Indicator Test Procedure Place a non-autoclaved, labeled control tube in the incubator Examine the indicator tube at 8, 12, 24, and 48 hours for any color change Yellow color change indicates bacterial growth Compare to non-autoclaved control at each time point Record 48 hour test results in Results Log

Learning Objectives Review What materials can be autoclaved? Surgical Instruments Glassware Plastic tubes and pipette tips Solutions and water Animal food and bedding Waste

Learning Objectives Review What Personal Protective Equipment (PPE) is necessary for autoclave use? Lilly_M (2011) Laboratory protection goggles [photograph]. Retrieved from https://commons.wikimedia.org/wiki/File:Laboratory_protection_goggles-blue.jpg Public Domain Pictures (2014), Retrieved from Pixabay

Learning Objectives Review How does one properly load the autoclave? Load material to allow efficient steam penetration Autoclave clean items and waste separately Do not allow material to be autoclaved to touch the sides or top of the chamber

Learning Objectives Review What steps assist in efficient decontamination of biohazardous waste? Add approximately 1 liter of water to 24” x 30” bag Loosely close autoclave bags Place packaged material in an approved 2° container

Learning Objectives Review How does one verify autoclave performance for decontamination of biohazardous waste? Each Load Verify cycle conditions via autoclave printout CITP indicator use Monthly Utilize Attest Biological Indicator Vial