DRAFT US Department of Energy Underground Fire Protection Guide James Priest, PhD & James Niehoff DGS-SEE Seminar on Fire Protection for Physics Research.

Slides:



Advertisements
Similar presentations
Facilities Management and Design Chapter 4 Safety and Security systems.
Advertisements

Initiating Devices Manual Fire Alarm Boxes Ionization Smoke Detectors
Tritium Management at Fermilab Stuart Henderson Associate Laboratory Director for Accelerators Community Advisory Board Meeting August 23, 2012.
Engineering Controls and Laboratory Design Session 4 Laboratory Safety Training.
Fire Safety The “Fire Triangle” identifies the three components of any fire: –Fuel paper, wood, flammable gas, energized electrical equipment, etc...
DIVISION OF YOUTH CORRECTIONS
Underground Facilities Stub 2 Stub 2a,3 ‘H’ Area JIF Area The underground research facilities have evolved since dark matter studies began at Boulby. There.
The Yucca Mountain Repository for Nuclear Waste April 23, 2007 Edward F. Sproat III Director Office of Civilian Radioactive Waste Management U.S. Department.
Dr. Bhavani Thuraisingham The University of Texas at Dallas (UTD) June 2011 Physical (Environmental) Security.
Smoke Control Fire-Rated Stairwells Fireproofing of Structural Components Egress Lighting Fire-Resistive Construction Elements Fire and Smoke Dampers Emergency.
2012 International Fire Code Adopted as the minimum fire safety standard by the State of Wyoming City of Sheridan must adopt the minimum standard to retain.
Global Design Effort - CFS ILC CFS Baseline Technical Review - CERN 1 ILC CFS BASELINE TECHNICAL REVIEW AMERICAS REGION LIFE SAFETY CONVENTIONAL.
Unit 8: Portable Fire Extinguishers & Smoke Control Management Systems
EGRESS AND FIRE PROTECTION
Business Owners and Managers and the Fire Code
Church Administrators & Emergency Planning
PERFORMANCE & CODE ANALYSIS TIMBer Inc. ·Brooke Fedder · Marie Rottschaeffer· Izzie Molinuevo· Tena Pettit·
Conventional Facilities and Siting Global Design Effort Safety Requirements for IR Conventional Facilities and Siting Group Safety Requirements for IR.
Global Design Effort - CFS for Asian Single Tunnel Configuration Design Progress Masanobu Miyahara KEK.
MODULE:3 FIRE CONFINMENT AND EXTINGUISHMENT. OBJECTIVES Module 3 Select and deploy the appropriate hose lines to accomplish fire confinement and extinguishment.
Fire Prevention for Construction. Four classes of fires  A, B, C, and D 1a.
Code of Federal Regulations 30 Part 57 – Safety and Health Standards – Underground Metal and Nonmetal Mines Subpart J – Travelways and Escapeways
CLIC CES Webex 12 Nov Summary: – Set of fire safety measures defined in CERN Safety Report – Proposed Structure for CLIC/ILC Fire Safety Report Fabio.
Joint ILC/CLIC Safety document ► Incentive for this document:  Share effort to define a coherent safety protocol for future linear colliders.  Insure.
Fire Safety By Alicia Civile and Alexandra Fernandez.
CLIC CES Meeting 14 jan 2009 A resume table for fire safety in LHC, and a possible scheme for other machine – part 1 CERN –SC Fabio Corsanego.
Conventional Facilities and Siting 1 Alternate Site and Tunnel Configuration Status Report KEK (2) Nov. 2008, Chicago Global Design Effort Masami Tanaka.
Lift Typical Building Floor Plan. Complete with fire walls. Click on and we will add Some of the different Passive and Active systems that you could come.
Fermilab Neutrino Program Jim Strait Neutrino Discussion at CERN 26 November 2013.
The Nuclear Fuel Cycle 1. NUCLEAR FUEL Nuclear fuel is the energy source of nuclear reactors and an essential element of the reactor core. The heat energy.
ID 308 Construction + Materials IV: Construction Documents Prof. Brody Endicott College Systems Coordination.
Chapter 5 ID 234 Building Codes Fire Resistant Materials and Assemblies.
code calculations, construction drawings
ID 234 Building Codes Life Safety Diagram:Review.
J T Volk Fermilab April 2008 Ground Motion Studies at Fermi National Accelerator Laboratory James T Volk Applications Physicist II Vladimir Shiltsev, Shavkat.
Clear thinking on Nuclear: Waste disposal 1.One site for high-level radioactive waste is easier to monitor, regulate, and secure 2.A repository will provide.
Fire Prevention Facilities of Building 1 Civil Engineering Department Safety Promotion Project.
Fire Safety: Fire Safety: Prevention, Exit Drills and Hazards.
Maine State Fire Marshals Office1 Laws and Codes Relating to Existing Apartment occupancies in the State of Maine Mark Stevens CFI-II, CFPS, CFPE Inspections.
Part C: Class D Fires and Tactical Considerations.
The Yucca Mountain Repository for Nuclear Waste June Edward F. Sproat III Director Office of Civilian Radioactive Waste Management U.S. Department.
Chapter 6 ID 234 Building Codes Fire Suppression.
Low Background Studies at the Soudan Underground Laboratory-9/20/ Low Background Studies at the Soudan Underground Laboratory The Soudan Underground.
FIRES NEED 3 THINGS TO START Oxygen (Air) Fuel (any material that will burn) Heat (sparks, matches, flames)
Subpart F - Fire Protection & Prevention ( ) Flammables/combustibles - Approved containers Fire protection program/equipment 2A fire extinguishers.
ME444 ENGINEERING PIPING SYSTEM DESIGN
6/7/20161 Underground Safety Training. 6/7/20162 Recognize the physical layout of MI-65 and MINOS underground. Be aware of specific hazards of the underground.
FIRE SAFETY Fire Warden Training. Objectives Review NAIT fire emergency response plan To be prepared confident and equipped.
KEK, 04/28/061 Safety Plan Assumptions Break out of fire in the Beam Tunnel is negligible Cables in the Service Tunnel is main fire load They are combustible.
50% LBNE Concept Design WCD Infrastructure. Mechanical.
AREA SAFETY LIAISON TRAINING  Jennifer Laine, MPH  Safety Manager – Occupational Safety and Fire Prevention  Environmental Health & Safety.
3M B&CSD - Fire Protection Space for 3M Montage © 3M All Rights Reserved. 3M Fire Barrier Duct Wrap 615 For Ventilation Ducts.
Nuclear Energy and the Environment. Current Role of Nuclear Power Plants Worldwide Worldwide 436 power plants 436 power plants 17% of electricity 17%
Exercise #2 (part 2) Based on what you read in Chapter 4, determine if the corridors and exit doors meet the requirements for egress width, according to.
50% LBNE Concept Design LAr Infrastructure. Mechanical.
DoD Fuels Laboratory Standards UFC
Civil Courthouse 201 Caroline
Family Law Center 1115 Congress
FIRE PROTECTION & SECURITY in ELI Beamlines
What Library Staff Should Know About Fire Safety
Wilson Hall Fire Protection Features
Juvenile Justice Center 1200 Congress
GES SYSTEM THE IMPORTANCE OF GES SYSTEM IN BUILDING
29 CFR NFPA Life Safety Code
Fire Prevention Safety Department
MINNESOTA STATE FIRE MARHSAL DIVISION HEALTHCARE TEAM
DIVISION OF YOUTH CORRECTIONS
Criminal Justice Center 1201 Franklin
Fire Evacuation Procedures
Presentation transcript:

DRAFT US Department of Energy Underground Fire Protection Guide James Priest, PhD & James Niehoff DGS-SEE Seminar on Fire Protection for Physics Research Facilities 7 & 8 October 2015

Disclaimer No US national safety organization wanted to develop a new standard or guide This guide is still being vetted by the US Department of Energy community 10/7/15 & 10/8/15Priest & Niehoff | US DOE Underground Guide2

Organization Purpose Applicability and Scope Definitions Fire Prevention Fire Protection Means of Egress Fire Department Response Underground Facility Rescue Underground Facilities Services 10/7/15 & 10/8/15Priest & Niehoff | US DOE Underground Guide3

DOE Sample Facility 10/7/15 & 10/8/15Priest & Niehoff | US DOE Underground Guide4

Soudan Mine 10/7/15 & 10/8/15Priest & Niehoff | US DOE Underground Guide5

10/7/15 & 10/8/15Priest & Niehoff | US DOE Underground Guide6

10/7/15 & 10/8/15Priest & Niehoff | US DOE Underground Guide7 Soudan Mine Fire

10/7/15 & 10/8/15Priest & Niehoff | US DOE Underground Guide8

10/7/15 & 10/8/15Priest & Niehoff | US DOE Underground Guide9

10/7/15 & 10/8/15Priest & Niehoff | US DOE Underground Guide10

10/7/15 & 10/8/15Priest & Niehoff | US DOE Underground Guide11

FacilityLocationDateHazardDepthExitsSelf Exiting Y/N Limits on Number of People Fire Suppression System MSHA 57.1 or NFPA 520 Waste Isolation Pilot Plant (WIPP) Chihuahuan Desert, outside Carlsbad, N.M. March 26, 1999 transuranic (TRU) waste 2150 ft3: Salt Handling Shaft, Air intake Shaft, & Waste Shaft No145Protect vehicles with dry chemicals, Alarms, fire brigades, shafts. MSHA: Yucca Mountain nuclear waste repository Nye County, Nevada Not yetspent nuclear reactor fuelspent nuclear reactor fuel and other high level radioactive wastehigh level radioactive waste 1,000 feet beneath the surface and 1,000 feet above the water table 4 The North Portal, designated ventilation intake shafts, South Portal, North Construction Portal. N/A Automatic (sprinkler), refuge stations, Rescue, isolation, ventilation Firewater, Fire suppression, Fire detection, Fire alarm, Fire notification, Explosion protection, Fire barriers MSHA: NFPA 520: No SLAC Linac tunnel Menlo Park, CA 1967 (date of first linac beam) Prompt radiation High intensity electron beam line for research purposes. 25 feetLadders every 333 feet (total of 15). Three stairwells to surface. Exit to grade at west end. YesDuring long downs, no more than 100 people in linac tunnels. Air sampling smoke detection, wall mounted C02 portable fire extinguishers. Fire hydrants at surface. Two cross-tunnel fire barriers. MSHA-no. NFPA 520-no. SLAC Beam Switch Yard (BSY) Menlo Park, CA 1967Prompt radiation from high intensity electron beam for research purposes feetOne grade level exit, two ladders to surface, 5 exits through other tunnel spaces. Yes50 employees maximum during long downs. Combination of spot- type smoke detection and air sampling detection. Wheeled and portable CO2 fire extinguishers. MSHA – No. NFPA 520—under review. SLAC LCLSMenlo Park, CA 2007 (first beam) Prompt radiation from electron and x-ray beam pulses used for research. 0 – 70 feetOne grade exit, two stairwells, one ramp up to grade YesVaries, but no more than 60 employees in any one fire area Sprinklers, wall- mounted CO2 fire extinguishers, spot type/beam type/VESDA smoke detection (varies by area) MSHA—no. NFPA 520-no. Fermilab- NuMIoutside Batavia, Illinois, near Chicago Batavia, Illinois Chicago November 21, 1967 (as National Accelerator Laboratory neutrino beam generated MI-65 Target Hall and MINOS Detector Hall) 150 ft to 350 ft2-hour fire rated, 44-in width pressurized passageway, stair, & egress elevator Yes50 Occupants Emergency voice fire alarm system, heat & smoke detection, sprinklers MSHA 57.1: n/a NFPA 520: Yes 10/7/15 & 10/8/15Priest & Niehoff | US DOE Underground Guide12

10/7/15 & 10/8/15Priest & Niehoff | US DOE Underground Guide Fermilab- ILCoutside Batavia, Illinois, near Chicago Batavia, Illinois Chicago FutureInternational Linear Collider – Conceptual Design Phase only. Currently this project is unfunded 350 ft2 & refuge areas with 2 hour fire barriers, stairs > 44 in. Wide, and doors > 36 in. wide. Yes<50 Occupantsfire alarm system, heat & smoke detection, sprinklers MSHA 57.1: n/a NFPA 520: Yes Fermilab - LBNE outside Batavia, Illinois, near Chicago November 21, 1967 (as National Accelerator Laboratory Long baseline neutrino experiment – Conceptual Design Phase 320 ft2-hour fire rated, 44-in width pressurized passageway, stair, & egress elevator Yes50 OccupantsEmergency voice fire alarm system, heat & smoke detection, sprinklers University of Minnesota – Soudan Underground Laboratory Near Ely Minnesota 1900-est. mine est. lab Several Experiments (MINOS long baseline neutrino experiment receives a beam of neutrinos from Fermilab). 2,340 ftFire Rated Single Shaft Elevator average -11; maximum- 36 fire alarm system, heat & smoke detection, Automated suppressant system- sprinklers, Extinguishers, and 1 escape chamber (shafts), ventilation Sanford Underground Research Facility - SURF (Deep Underground Science and Engineering Laboratory, DUSEL) Homestake, SD 2002Experiments LUX- the most sensitive detector yet to search for dark matter cryogens and other hazardous materials 4850 ft below ground 2: Primary and secondary Yes **two means of access/egress will be provided Notification of an emergency “stench gas” system MSHA 57.1: Yes NFPA 520: Yes Nevada National Security Site Nye County, NV 1950s 8 active & 14 inactive facilities; hazards vary by facility but may include explosives, radioactive materials, wood, paper, oils, etc. Varies from hundreds to thousands of ft Shafts and portals depending upon the facility Yes and no, varies by facility. One facility has 3 shafts and the others have portals Varies by facility and by activity Varies by facility: Portable fire extinguishers, fire alarm systems, squawk boxes, miners cap lamps & emergency lighting, refuge stations, no automatic suppression. No & No** Ultra Low Background Counting Laboratory 3425 Building PNNL Richland, WA2010R&D Lab with some hazardous materials, cryogens 40 ft2 exits – one at each end of the building Yes30 – typically less than 10 N/A This is a building built per IBC and NFPA

Go to Draft Guide 10/7/15 & 10/8/15Priest & Niehoff | US DOE Underground Guide14