G GE Power Management 269Plus Motor Management Relay.

Slides:



Advertisements
Similar presentations
Variable Frequency Drives Bypass Options
Advertisements

CL100D series DSP controlled Uninterruptible power supplies.
سیستم آلارم دیجیتالی مجهز به ثبات خطا
CommentaryVideo Hi, my name is Edward Guillergan and I’m one of AMETEK Programmable Power’s Applications Engineers. I’m here to provide an overview of.
Static Transfer Switch
Model H Free Standing Static Transfer Switch. Why choose a model H static transfer switch? Increases power availability. True solid state. Rugged, reliable.
Model W Wall Mount Static Transfer Switch. Why choose a model W static transfer switch? Increases power availability. Integrated maintenance bypass. True.
New Energy Horizons Opportunities and Challenges Fault Current Contributions from Wind Plants Dean Miller PacifiCorp July 25,
Submitted by: Name:Rajendra Kumar Choudhury Branch:Electrical Engg.
Three-Phase AC machines
MIFII DIGITAL FEEDER PROTECTION A Cost Effective Protection Solution for Overcurrent Protection at Any Voltage Level GE Multilin
WELCOME. Controllers Controller 1/32 DIN FKS SMART function for the self-tuning of control parameters. TC, RTD or linear input programmable. Dual Outputs,
GENERATOR PROTECTION.
FP5000 Refer to for the latest information on this constantly evolving productwww.eatonelectrical.com.
SYMAP-BC SYMAP-BC.
Generator Management Relay
M Family Industrial Systems 1 M Family relays provide economical & reliable digital protection, metering, control and monitoring in an integrated package.
Introducing GAC’s New Line of Intelligent Generator Set Controllers.
Introducing GAC’s New Line of Intelligent Generator Set Controllers
Slide 1 / 35 P&T - GPS - Training PhB - 01_TECH_TeSys_U_controller_ en 06/2004 Presentation of the range Composition of the controller  Control base 
G GE Power Management MMII Intelligent MCC Controller.
Generator Protection. Amount of Protection Rated power of the generator Ratio of its capacity to the total capacity of the system Configuration of the.
Chapter 8 Output Modules.
Industrial Systems Introducing the L90 Universal Relay Advanced transmission line protection and control High-speed current differential protection for.
MIG II DIGITAL FEEDER PROTECTION
Chapter 7 SYSTEM PROTECTION
Section 4: Electric Motors
MP-3000 Motor Protection.
Motor Protection for this Millennium
G GE Power Management 369 Motor Management Relay.
Alternative Energy Class Room Automation Control System Lighting and Temperature Control By: Al Woodward EET-2011.
1 Industrial Systems A dvanced L ine P rotection S ystem.
Workflow Based Tools Simplifying All Job Functions.
G650 Generator Protection & Control System
© 2006, ZTE Corporation. All rights reserved.   E300 Series Mini-type Integrated Universal Inverter.
FG Wilson Access 4000 Control Panel
MarsⅡ On-Line UPS Series
LDA Large Display for Analog Inputs. Agenda What is the LDA? Easy programming About the input Setpoint control Communication Other features Packaging.
Current operation (black keys) Descriptions Parameter / protection setting (blue keys) Main points to remember A B C D ? SEPAM UMIs SEPAM UMI OPERATION.
The PAX Lite: PAX quality at a great low price.. PAX Lite Series Indication and Setpoint Control Simple field set-up Perfect the low-cost meter users.
VS mini J7 COMPACT INVERTER FOR GENERAL USE
Motor-driven pumps  Sigma/ 1  Sigma/ 2  Sigma/ 3.
Universal Relay Family B30 Presentation Q&As. Power Management The Universal Relay Contents... Application Algorithm Biased Characteristic Dynamic Bus.
3-Phase Submersible Motor Control
YASKAWA VS-606 V7 COMPACT VECTOR - CONTROLLED INVERTER FOR GENERAL USE 230V (Single-Phase).1Kw ~ 3.7Kw (.13HP ~ 5HP) 230V (Three-Phase).1Kw ~ 7.5Kw (.13HP.
SmartMQn Motor Horner APG, LLC September 9, 2008.
Motor. What Does it Do? Monitors three phase motors for a number of current, temperature, estimated power and timing parameters. Provides motor protection.
Franklin Electric - The Company You Trust Deep Down Provides The Ultimate Protection for Your Pump & Motor! Franklin SubMonitor.
CUE – Make Any Pump an E-Pump
Hydro Multi-B – (2) or (3) CME Pumps in Parallel
SmartMQn Motor Protective Functions Ken Jannotta Jr. Horner APG, LLC.
1 Industrial Systems BUS2000 Busbar Differential Protection System Differential overcurrent system with percentage restraint protection.
Alarm units AL 175 NT and Aeon Gold For small, medium and large power range.
BASIC ELECTRICITY AND MAGNETISM
Comparison between MPR300 & Bimetal relays.
M20 Shaft Power Monitor PRODUCT TRAINING. Topics 1.What is an M20 Shaft Power Monitor 2.How does it measure Shaft HP 3.Benefits of Shaft Power measurement.
TPS - Thyristor Power Supply for Resistive/Inductive Loads
E2 Motors and Motor Starting
GROUND-FAULT GROUND-CHECK MONITOR
FEEDER PROTECTION UNIT
MPU-16A MOTOR PROTECTION UNIT.
MPU-16A / FPU-16 TEST UNIT TUTORIAL
Protection Philosophy
ACOE347 – Data Acquisition and Automation Systems
PowerLogic™ offer for the basic metering market
Presentation transcript:

g GE Power Management 269Plus Motor Management Relay

g GE Power Management 269Plus Motor Management Relay Offering optimum motor protection in situations where other relays cannot, the 269 Plus Motor Management Relay possesses the unique feature of its ability to “learn” individual motor parameters, giving it the flexibility to adapt to each application by “learning” values of motor inrush current, negative sequence current K factor, cool down rates, start thermal capacity and acceleration time.

g GE Power Management 269Plus Motor Management Relay Presentation Overview 6 Applications Applications 6 Protection and Protection and Protection and Control Control 6 Metering and Metering and Metering and Monitoring Monitoring 6 Inputs and Inputs and Inputs and Outputs Outputs 6 User Interface User Interface User Interface 6 Ordering Ordering 6 Communications Communications 6 Typical Wiring Typical Wiring Typical Wiring

Applications g GE Power Management 269Plus Motor Management Relay The 269 Plus is a microprocessor based product designed to provide complete and accurate protection for industrial motors and their associated mechanical systems.  Three phase AC motors  Mechanical system protection MAIN

g GE Power Management Applications G 400A 4160V BUS (4) ISOLATED ANALOG OUTPUTS COMMUNICATION with METERING OPTION VOLTS METERING OPTION AMPS MPM G 51G b RTD MOTOR LOAD AMBIENT AIR STATOR RTDs BEARING RTDs SPEED DEVICE CONTACTS DIFFERENTIAL RELAY CONTACTS SPARE INPUT STARTER AUXILIARY B CONTACT RS485 REMOTE COMMUNICATION SELF TEST ALARM AUXILIARY RELAY #1 AUXILIARY RELAY #2 TRIP RELAY ALARM RELAY GROUND CT PHASE CTs FUSED CONTACTOR 269PLUS RELAY FUNCTIONAL BLOCK DIAGRAM MAIN Legend

g GE Power Management Applications 14 Speed Device 37 Undercurrent/Minimum Load 38 Motor/Load Bearing Overtemperature 46 Unbalance - Negative Sequence 48 Multiple Starts/Locked Rotor 49 Stator Winding Overtemperature 49/51 Overload Curves/FlexCurves 50 Short Circuit/Mechanical Jam/Rapid Trip 50G/51G Zero Sequence Ground Fault 50N/51N Residual Ground Fault 52b Breaker 74 One Alarm Relay, Two Auxiliary Relays 86 Main Trip Latched Relay Auxiliary Relay No. 1 Auxiliary Relay No Differential Relay Contact Input 66 Starts per hour 47 Volts Phase Reversal (Meter Option) 27 Undervoltage (Meter Option) Frequency (Meter Option) 55 Power Factor (Meter Option) DEVICE PROTECTION

g GE Power Management 269Plus Motor Management Relay Protection  Stator winding overtemperature  Bearing overtemperature  Multiple starts  Overloads  8 standard overload curves  Ground fault  Undercurrent  Phase reversal (meter option)  Variable lock out time  “Learns” individual motor parameters  Short circuit  User defined overload FlexCurve TM  Locked rotor  Rapid trip/mechanical jam  Unbalance/single phasing MAIN

g GE Power Management Start and Running 269Plus Motor Management Relay  Motor is protected under both Acceleration and Running conditions The 269 Plus can trigger an alarm or trip the motor based on:  normal acceleration time  number of starts per hour  multiple starts  time between starts  motor overload conditions MAIN

g GE Power Management  One of eight standard overload curves may be programmed based on motor manufacturer’s locked rotor time capability.  Alternately, the user may program in a custom curve using the built- in FlexCurve™ function. Protection Overload MAIN View 8 Standard Overload Curves

g GE Power Management Protection 8 Standard Overload Curves Full Load Current SetpointMultiples of Full Load Current Setpoint  The motor’s service factor value is entered as the overload pickup level

g GE Power Management FlexCurve can be used to protect motors which have different rotor and stator damage, allowing total motor design capacity with complete protection. When a FlexCurve is programmed, the 269 Plus develops a smooth custom overload curve within a selected range. Protection FlexCurve™ Multiples of Full Load Current Setpoint 6500 HP, Volt INDUCED DRAFT FAN MOTOR 1) Programmed 269 Plus Custom Curve 2) Running Safetime (Rotor Limited) 3) Acceleration Safetime (Rotor Limited) 4) Motor 100% Voltage 5) Motor 80% Voltage

g GE Power Management Protection Thermal Modeling The Thermal Model within the 269Plus has the ability to compute the motor I 2 t value based on actual motor load current.  thermal model calculates value in terms of thermal capacity used  RTDs (resistance temperature units) measuring stator temperature act as a thermal capacity check to confirm value calculated by thermal model. RTDs may be used for monitoring stator, bearing, ambient, or other temperature monitoring.  thermal capacity used is then updated to reflect the higher of the two values MAIN

g GE Power Management Protection MotorMatch modifies the initially entered relay parameters to match actual measured motor characteristics. The key elements include:  accumulated I 2 t in the memory  RTD input to the memory  learned cooldown time from run to stop  learned cooldown time from run- overload to run-normal  learned acceleration time  learned negative sequence contribution (K-factor) Motor Match MAIN

g GE Power Management Protection RTD Hot Motor Compensation When hot motor compensation is enabled:  RTD feedback from actual stator temperature checks the thermal capacity model  User has the capability to match the motor thermal characteristics with a dual slope RTD bias curve  The two part curve allows for easy fitting of hot and cold motor damage curves to the RTD bias feature MAIN

g GE Power Management 269Plus Motor Management Relay User Interfaces = PC Software for setting, monitoring = 48 character alpha-numeric backlit LCD display = Five Target LED indicators = MPM (meter) com port = RS485 com port (ModBus® RTU) MAIN

g GE Power Management User Interfaces HELP KEY  Help key can be pressed at any time to provide additional information PROTECTIVE COVER  Rugged, corrosion and flame retardant case  Meets IP53/NEMA 12 MAIN

g GE Power Management User Interfaces DISPLAY  48 Character alpha-numeric backlit LCD display for viewing actual values, causes of alarms and trips, and programming setpoints. STATUS INDCATORS  5 LEDs indicate when an output is activated. When an LED is lit the cause of the output relay operation will be shown on the display. KEYPAD  Used to select the display of actual values, causes of alarms, causes of trips, fault diagnosis and to program setpoints. I 1=120I 2=120 I 3=121(AMPS) MAIN

LINE g GE Power Management User Interfaces CONTROL POWER  120/125 AC/DC  240/250 AC/DC  24 AC/DC, 48 AC/DC 4 OUTPUT RELAYS  Programmable alarm and trip conditions activated by:  programmable setpoints  switch input  remote communication control RTD 7-10  Can be assigned to monitor motor and load bearings, and ambient temperature INPUTS/OUTPUTS  Spare input  MPM (meter) com port  Differential relay input  Speed switch input  Access input  Emergency restart  External output  Analog output  RS485 com port RTD 1-3  Typically used for stator winding protection RTD 4-6  Typically used for stator winding protection Phase and ground CT inputsContrast dial MAIN

g GE Power Management 269Plus Motor Management Relay Communications = Successfull interface with many PLCs such as Modicon, Square D, Allen Bradley and GE Fanuc Protocol   Modbus® RTU protocol Terminals for RS485 located on rear port of the relay MAIN

g GE Power Management 269Plus Motor Management Relay Metering  average and individual phase currents  RTD temperatures (hottest, individual, maximum)  unbalance ratio (%I n /I p )  ground leakage current  thermal capacity remaining / estimated time to trip at present overload level  motor load as a percent of full load  phase to phase or phase to neutral voltage (meter option)  W, var, MWhr, PF, Hz (meter option) Actual Values MAIN

g GE Power Management 269Plus Motor Management Relay Monitoring  immediate overload/stall warning  ground fault  mechanical jam  unbalance  undercurrent  RTD overtemperature, broken RTD sensor, low temperature RTD  self-test-service  under/overvoltage (meter option)  low power factor (meter option) Prior Alarms MAIN

g GE Power Management 269Plus Motor Management Relay Monitoring Fault Diagnosis = 269 Plus displays the cause of the trip and will show the remaining lock-out time if applicable = cause of the last trip and pre-trip values can be recalled for rapid fault diagnosis. MAIN

g GE Power Management 269Plus Motor Management Relay Statistical Data (StatTrac TM ) = StatTrac TM provides statistical data of motor use for operations monitoring, maintenance, and fault diagnosis. = Using the Keypad, the user can display: Monitoring = running hours and number of starts since last commissioning = number of all trips = number of specific types of trips = total Watt-hours (with meter option) MAIN

g GE Power Management 269Plus Motor Management Relay Inputs  Speed Switch Input  Differential Relay Input  Spare Input = enables the user to use an external speed device = provided terminals to accept contact closure from an external differential relay = all protective functions grouped through one main relay = spare input terminals configurable to represent either a standard contact input (ie-pressure switch), or a specific contact input (circuit breaker/contactor status) = 52b contact from a circuit breaker = positive identification of the position of the breaker(open or closed) MAIN

g GE Power Management 269Plus Motor Management Relay Outputs  4 Output Relay Contacts  Trip Relay as main latched output relay  Alarm output relay (latched or unlatched)  Auxiliary 1 output relay (latched or unlatched)  Auxiliary 2 output relay  Analog output  Used to indicate motor thermal capacity used, motor current, hottest stator RTD, bearing RTD, or CT secondary current MAIN

MOTOR ZERO SEQUENCE GROUND CONNECTION 269Plus TYPICAL WIRING RESIDUAL GROUND CONNECTION (ALTERNATE) ALTERNATE CONNECTION FOR COMMON SHIELD STARTSTOPFUSE GROUND BUS 52b METER COM PORT EXTERNAL CONTACTS JUMPER OR KEYSWITCH KEYSWITCH EXTERNAL RESET AMMETER OR PROGRAMMABLE CONTROLLER RS485 COM PORT GROUNDED AT MASTER ONLY PHASE A CT MAIN PHASE B CT PHASE C CT50:0.025 GROUND CT PHASE A CT PHASE B CT PHASE C CT

269PLUS **** * * 269PLUS Motor Management Relay SVStandard version D/ODrawout version Phase CT 1 Ground CT (required for D/O only) 1:52000:1 2:5:5 3:12000:1 4:1:5 Relay fail safe code 2 (required for D/O only) TripAlarmAux1Aux2 1FSNFSNFSFS 2NFSFSNFSFS 3FSFSNFSFS 4NFSNFSFSFS 5FSNFSFSFS 6NFSFSFSFS 7FSFSFSFS 8NFSNFSNFSFS Relay contact arrangement 3 (required for D/O only) AlarmAux1Aux2 1N.O.N.O.N.O. 2N.O.N.O.N.C. 3N.O.N.C.N.O. 4N.O.N.C.N.C. 5N.C.N.O.N.O. 6N.C.N.O.N.C. 7N.C.N.C.N.O. 8N.C.N.C.N.C. 100P100 Ohm platinum RTD 10C 10 Ohm copper RTD 100N100 Ohm nickel RTD 120N120 Ohm nickel RTD AC/125 DC control voltage AC/250 DC control voltage 24DC24 DC control voltage 48DC48 DC control voltageOR D E R CO D E g

g GE Power Management 269Plus Motor Management Relay Contact : GE Power Management 215 Anderson Ave., Markham, Ont. Canada L6E 1B3 Tel: Fax: