Gaining New insights into Pharmaceutical Stability using High Resolution MS with on-Line Electrochemical Reaction Cell Mark R Taylor 1 *, G. John Langley.

Slides:



Advertisements
Similar presentations
Electrochemistry upfront MS
Advertisements

Expect the unexpected An example of how unanticipated fragmentation behaviour could preclude correct assignment of sites of metabolism Stephen W. Holman.
Redox Mechanisms of Rohypnol and Mogadon and Their Exploitation in an Assay Using Dual Electrode ECD Following HPLC K.C. Honeychurch, H. Li, S. Pericleous,
Improvements in Mass Spectrometry for Life Science Research – Does Agilent Have the Answer? Ashley Sage PhD.
Mass Spectrometry Mass spectrometry involves ionizing a compound, separating the ions that result on the basis of mass to charge ratio (m/z) and obtaining.
Patil et al., Phys. Chem. Chem. Phys. 2000, 2, Methylene blue undergoes a concentration and ionic strength-dependent dimerization: λ max (monomer)
CHEMISTRY ANALYTICAL CHEMISTRY Fall Lecture 1.
Ionic Liquids for Natural Product Extraction
Synthesis of Magnetic Room Temperature Ionic Liquids Acknowledgments I would like to thank Roy Planalp for his help for his help in organization and advice.
Mass Spectrometry II. Ion trap Magnetic Sector FBFB.
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 15 DR. AUGUSTINE OFORI AGYEMAN Assistant professor of chemistry Department of natural sciences Clayton state university.
Vinh Tran Chem Fall 2011 December 9, 2011.
This work is licensed under a Creative Commons Attribution-Noncommercial-Share Alike 2.0 UK: England & Wales License REDOX reactions.
Molecular Mass Spectrometry
Investigation of Oxidative and Conjugative Metabolism Reactions with Liquid Chromatography / Accurate Mass High Resolution Mass Spectrometry Maciej Bromirski.
Instant Notes Analytical Chemistry
Unique Selling Points (USP) ROXY and Accessories Antec BV Zoeterwoude, The Netherlands 1.
Mass Spectrometry Mass spectrometry (MS) is not true “spectroscopy” because it does not involve the absorption of electromagnetic radiation to form an.
B. AmsdenCHEE 440 Stability The extent to which a product retains, within specified limits, and throughout its period of storage and use, the same properties.
CHEE Stability u the extent to which a product retains, within specified limits, and throughout its period of storage and use, the same properties.
Voltammetry: A Look at Theory and Application Bobby Diltz 14 March 2005.
Electrochemistry Introduction
Electrochemical Cell An electrochemical cell uses chemistry to produce electricity.
Advanced Biology Matter and Energy Chemistry Molecules of Life.
1 Chemical Analysis by Mass Spectrometry. 2 All chemical substances are combinations of atoms. Atoms of different elements have different masses (H =
Institute of Organic Chemistry and Biochemistry AS CR, v.v.i. Czech University of Life Sciences Prague Jana Jaklová Dytrtová, Michal Jakl.
Mike Rusak and Laura Fairburn CURRENT OBSTACLES ON THE APPLICATION OF AMBIENT IONIZATION MS IN FORENSICS.
Electrochemistry Electrolysis Electrolytic Cells An electrolytic cell is an electrochemical cell that undergoes a redox reaction when electrical energy.
High throughput Protein Measurement Techniques Harin Kanani.
Measurements in Fluid Mechanics 058:180:001 (ME:5180:0001) Time & Location: 2:30P - 3:20P MWF 218 MLH Office Hours: 4:00P – 5:00P MWF 223B-5 HL Instructor:
Smoke Investigation of the germination promoting compounds in smoke
Predictive safety study of ticagrelor's degradation combining LC-MS and in silico approach H. SADOU YAYE*, B. DO, N. YAGOUBI * Pharmacist at Pitié-Salpêtrière.
Inorganic chemistry Assistance Lecturer Amjad Ahmed Jumaa  Electrochemistry.  Oxidation –reduction concepts.  Standard reduction potentials.
Electricity from chemical reactions Galvanic Cells Chapter 14.
Detection of Ziram by LC/APCI/MS Hiroshi MORIWAKI
Background Aerosols are studied for –Environment impact Direct climate effect Indirect climate effect –Biofuels –Human health impact Medicinal Cigarette.
Stability Indicating Assays for Dose Formulation Stability Testing Teresa Fuller GSK.
Updates of Iowa State University S. Dumpala, S. Broderick and K. Rajan Sep – 18, 2013.
Mass Spectrometry Quantitative Mass Spectrometry
Best seen broken into four categories Part 1: Ion Selective Electrodes Part 3: Step Voltammetry Part 2: Amperometric Sensors Part 4: Cyclic Voltammetry.
LYOPHILIZATION TECHNIQUE: OVERVIEW
INTRODUCTION Chemical quality control of peptide functionality testing in tissue baths. M. Verbeken 1, S. Van Dorpe 1, R. Lefebvre 2 and B. De Spiegeleer.
Impurities in Drugs author: srikanth N
Selling Restek LC Solutions for Analytical Scale Laboratories Rick Lake Product Line Manager Liquid Chromatography x 2379
Pharmaceutical Stability Testing Using Electrochemistry/MS ASMS 2015 St. Louis, MO, USA.
3M Drug Delivery Systems 3 Introduction A family of hydrofluoroalkane-compatible excipients based on oligomeric lactic acid (OLA) has been proposed for.
3M Drug Delivery Systems 3 Maggi G. Tebrake a Monica Dolci b, and Roger M. Smith b a) 3M Healthcare Limited, Morley Street, Loughborough, Leics LE11 1EP.
Electrochemistry Dr. Mamun Jamal Department of Chemistry Room no.: BECM 403 (main academic building) KUET.
In voltaic cells, oxidation takes place at the anode, yielding electrons that flow to the cathode, where reduction occurs. Section 1: Voltaic Cells K What.
Page 1 NMR Services —by Creative Biostructure. Page 2 NMR spectroscopy is a key analytical technique for structure elucidation of a wide range of materials.
New ‘chemistry’ projects in the iPRD
Mimicking Oxidative Metabolism “OxMet” using ROXY EC System
LC-MS/MS Identification of Impurities Present in Synthetic Peptide Drugs Dr Anna Meljon*, Dr Alan Thompson, Dr Osama Chahrour, and Dr John Malone Almac.
Mass spectrometry is one of the most important techniques used in today modern laboratories and especially chemical industry. Mass Spectrometry is the.
Environmental Degradation of Pharmaceuticals and Pollutants using EC/MS ASMS 2015 St. Louis, MO, USA.
CH3204 Organic Chemistry Laboratory
Analytical Chemistry Jony Mallik M.Pharm
An electrochemical cell uses chemistry to produce electricity.
Jesse C. Seegmiller, John H. Eckfeldt, John C. Lieske 
Solar-Thermal Decoupled Electrolysis: Assessment of MnxOy Systems
Complex Anode Kinetics Chronocoulometry Evidence
Introduction: Matter and Measurement
Cyclic Voltammetry Dr. A. N. Paul Angelo Associate Professor,
Pharmaceutical Stability Testing using Electrochemistry-MS
Electrochemical Synthesis of Metabolites, Degradants, Reference Materials ASMS 2018 San Diego, CA, USA.
Oxidative Properties of Wire-In Electrodes for nano-ESI-MS
Presentation transcript:

Gaining New insights into Pharmaceutical Stability using High Resolution MS with on-Line Electrochemical Reaction Cell Mark R Taylor 1 *, G. John Langley 2, Teresa Parsons 1, Rosalind Richards 1, Devan Panchal 3, Ruth Boetzel 1, Fiona Harvey-Doyle 1, Paul Carrick 1 and Roland Brown 1 1 Pharmaceutical Sciences Department, Pfizer Global Research and Development, Discovery Park House, Discovery Park, Ramsgate Road, Sandwich, Kent, CT13 9NJ, U.K. 2 Department of Chemistry, University of Southampton, Southampton, SO17 1BJ U.K. 3 School of Chemistry, University of Bristol, Bristol, BS8 1TS, U.K. 1.Abstract 2.Rapid Characterisation of API, Excipient and Drug Product Redox Degradation using Antec ROXY Potentiostat & EC Cells Summary 6.Study of Anti-Oxidant Performance 5. Study of Excipient Oxidation by EC-MS and EC-IC-PAD The advent of EC-HR-MS has given us a new way of studying pharmaceutical stability and a convenient & controllable method of performing purposeful degradation without need for oxidising agents and with rapid, real-time results The technique is well precedented in drug metabolism studies but we feel it has untapped potential (pardon the pun !) for a host of other pharma-related studies including formulation design, standard synthesis and accelerated structure elucidation and we will continue to research these over the next few years 4.EC-UHPLC-UV-ESI-TOF-MS of Naltrexone API Solutions 3.Voltage Ramping EC-HR-MS of Naltrexone API Solutions Understanding pharmaceutical stability is of fundamental importance to the industry. Stability studies at varied temperature and humidity and purposeful degradation experiments using chemical and thermal methods are widely applied to aid understanding of the stability and degradation of active pharmaceutical ingredients and formulated drug products during development. Many pharmaceutical degradation reactions occur by redox mechanisms and the recent advent of commercial flow-through electrochemical (EC) reaction cells has provided a new and convenient method of studying these reactions, with on-line high-resolution mass spectrometry (HR-MS) providing the means to identify and quantify degradation product profiles under varied experimental conditions. EC- HR-MS also has further utility for study of drug-excipient interactions and can be scaled up and coupled to liquid chromatography to provide the means to separate and isolate degradation products for further study. This paper shows results from some preliminary experiments applying EC- HRMS and EC-LC-HRMS-MS to study the electrochemical degradation of active pharmaceutical compounds and excipients µ -prep cell Interchangeable electrodes Solutions were typically prepared in MeCN:Water containing 5 mM NH 4 OAc at concentrations of 5 µg/mL for direct MS infusion and 50 µg/mL for off-line collection ahead of LC-MS-MS. HR-MS experiments were performed using Bruker Maxis and LC-MS was also performed using Waters Acquity UHPLC with LCT premier TOF-MS Overlaid EC-HR-MS EICs (Mass Voltammograms) from naltrexone solution infused to Bruker Maxis HR- MS with programmed oxidation voltage ramp of 0- 3 volts over 5 minutes. Molecular formulae of oxidation products determined rapidly from Acc Mass ESI-MS using Bruker Compass Smart Formula Chemistry Software application Naltrexone Overlaid UV chromatograms (280 nm) of 500 µg/mL solutions of A: aged naltrexone HCl standard and B: naltrexone HCl standard oxidised by EC at 1.3V in DC mode showing base-peak mass assignments from TOF-MS. The LC method was not optimised and some co-elution of degradation products occurred. Hydroxylated, dehydrated and dimerised degradant product peaks were identified and concentrations of the “real world” degradants observed API in the aged standard were increased significantly facilitating structure elucidation by HR-MS-MS. A number of isobaric species were also observed resulting from anomerisation / hydroxylation in different ring positions. 2,2-Bis(naltrexone) C40H44N2O8 MW = hydroxynaltrexone C20H23NO5 MW = 357 Trihydroxy-NLT isomers Glucose oxidises in solution to form the potentially genotoxic impurity (PGI) 5-HMF, which then further oxidises when autoclaved. The oxidation of glucose could be carefully and controllably studied by EC-MS and the degradant peak profiles from an autoclaved glucose solution closely matched those observed by EC-HR-MS and EC-IC-PAD. Degradant formulae were confirmed using Bruker maxis MS and Smart formula software application. Davis, S. E., B. N. Zope, et al. (2012). Green Chemistry 14(1): The effectiveness of butylated hydroxytoluene (BHT) as an anti-oxidant to stabilise oxycodone (OC) in solution was studied by EC-MS and EC-LC-UV-MS. The addition of BHT to the solution significantly increased the OC molecular ion base peak intensity and reduced the yield of oxycodone degradant peaks produced when voltage was applied to the EC cell. The fine voltage / reaction control offered by the EC-MS system allowed reactions to be studied rapidly in real time. C 18 H 21 NO 4 Mr = 315 EC-MS: Infusion mode (DC) LC-UV Chromatograms (240 nm) OC