1 ILD inner region integration meeting M. Joré – Introduction ILD inner region integration meeting Welcome words Charge of the meeting The current concept.

Slides:



Advertisements
Similar presentations
5 th ILD Workshop Orsay, 23 rd -25 th May 2011 D. Moya, J. Duarte, I. Vila, A. Ruiz - IFCA (CSIC-UC) F. Arteche, C. Esteban - ITA Strip FTD Readiness for.
Advertisements

CO2 cooling for FPCCD Vertex Detector Yasuhiro Sugimoto KEK 1.
LCWS 31/5/2007Erik Johnson STFC,RAL1 ILC Vertex Detector Mechanical Studies Erik Johnson On behalf of the LCFI collaboration STFC, Rutherford Appleton.
1 Integration issues of FPCCD VTX Yasuhiro Sugimoto May 22,
Performance of the DZero Layer 0 Detector Marvin Johnson For the DZero Silicon Group.
1 Design of Solenoid and iron yoke for GLD KEK Hiroshi Yamaoka Ken-ichi Tanaka July 13, ‘05.
Tracking Integration Challenges Y. meeting 2013/9/25.
1 ILD/CMS Engineering Meeting M. Joré – ILD integration philosophy Integration philosophy of ILD Matthieu Joré – January 21st Integration of the subdetectors.
VELO workshop, Amsterdam, april ‘00M.Ferro-Luzzi Difficulties with current mechanical design recent FEA results: to obtain sufficient stiffness of center.
18 November 2010 Immanuel Gfall (HEPHY Vienna) SVD Mechanics IDM.
ILC / ILD TPC Requirements of the support mechanics Volker Prahl ILD Workshop 2013 Cracow
V. Bobillier1 Long distance cable installation status Calorimeter commissioning meeting.
Summary: Mechanics - Overview of the MFT in ALICE. - Description of the MFT. - Description of a MFT detection plane. - Environment of the MFT. - Procedure.
R&D status of FPCCD VTX and its cooling system Yasuhiro Sugimoto for FPCCD VTX group 1.
09/03/2010 ADO-PO section meeting Beam Pipe Extraction/Insertion R. Vuillermet.
IPN Lyon ILD Mechanical structure April 2012 DHCAL Assembly, Tooling, Cooling J.C Ianigro - IPN Lyon -
1http:// 22/4/2010 Introduction WG4 Outline: Mandate of the WG Timescale How to proceed? Vertex detector requirements Collecting input on.
ACFA-7; Taipei, Nov 2004 H.Weerts status Si licon D etector Status H.Weerts Fermilab/Michigan State Univ. (Progress on Si-tracker layout)
B-layer integration with beam-pipe and services ATLAS B-layer upgrade E. Anderssen A. Catinaccio.
FPCCD option Yasuhiro Sugimoto 2012/5/24 ILD 1.
M. Gilchriese U.S. Pixel Mechanics Overview M. G. D. Gilchriese Lawrence Berkeley National Laboratory April 2000.
LumiCal mechanical & sensors design Wojciech Wierba J.Błocki, E.Kielar, J.Kotuła, K.Oliwa, L.Zawiejski FCAL Workshop, IFJ PAN Cracow,
ATLAS 1 Beam Pipe Support Structure (BPSS) Interface and Assembly Final Design Review, April 2003 E. Anderssen, N. Hartman LBNL.
Takeshi Matsuda LC TPC Collaboration March 5, 2008 TPC Endcap Materials.
ATLAS 1 Beam Pipe Support Structure (BPSS) Services Interface and Assembly Final Design Review, April 2003 E. Anderssen, N. Hartman, A Smith, LBNL S. Coelli,
Integration with LDC & Push-pull impact on LumiCal Wojciech Wierba Institute of Nuclear Physics PAN Cracow, Poland FCAL Workshop, LAL Orsay,
1 FPCCD VTX Work Plan Y. Sugimoto 2010/1/22. 2 FPCCD: Features and R&D issues (1/2) Small pixel size (~5  m) –Sensor development Small size chip; ~6mm.
Alpine pixel layout Integration progress Teddy Todorov For the ATLAS-LAPP group AUW Integration meeting 20/11/2012.
1 ILD meeting LAL M. Joré – Integration status Matthieu Joré – 25 th of May ILD integration status and open issues.
J-C Brient-DESY meeting -Jan/ The 2 detector options today …. SiD vs TDR [ * ] [ * ] J.Jaros at ALCPG-SLAC04 ECAL ECAL tungsten-silicon both optionsHCAL.
TC Straw man for ATLAS ID for SLHC This layout is a result of the discussions in the GENOA ID upgrade workshop. Aim is to evolve this to include list of.
(Some thoughts/reminders on) Calibration/alignment scenarios for ILD/ILC Jan Timmermans – NIKHEF Amsterdam 07 Sep 2014ILD meeting Oshu1.
ILD Vertex Detector Y. Sugimoto 2012/5/24 ILD
February 14, Comprehensive Review B. Schmidt Outline: Status and overview of activities: –Platforms and staircases –Muon Filters and beam plugs.
V. Bobillier1 Cable installation status.
Assembly scenario of ILD Si trackers 2015/4/21 Yasuhiro 1.
Upgrade PO M. Tyndel, MIWG Review plans p1 Nov 1 st, CERN Module integration Review – Decision process  Information will be gathered for each concept.
LCTPC “Advanced Endplate” (Discussion) LC TPC Meeting at ALCGP07 T. Matsuda.
8/12/2010Dominik Dannheim, Lucie Linssen1 Conceptual layout drawings of the CLIC vertex detector and First engineering studies of a pixel access/insertion.
TRACKING AND VERTEXING SUMMARY Suyong Choi Korea University.
Redesign of LumiCal mechanical structure W.Daniluk, E.Kielar, J.Kotula, K.Oliwa, Wojciech Wierba, L.Zawiejski Institute of Nuclear Physics PAN Cracow,
Power, Cooling, Cables, Simulations of Heat Dissipation Short overview of ongoing work on these points Technical Coordination (Rolf Lindner et al.) Cooling.
IPN Lyon ILD Mechanical structure February 2015 Design, Integration & Services J.C Ianigro - IPN Lyon -
MEA Machine and Experiment Assembly Norbert Meyners, MEA 12. July 2007ILC IRENG07 WG-A1 LDC Engineering Design (Status) Introduction General Design Detector.
T-THERMO-MECHANICAL MODEL FOR THE LC FORWARD TRACKER Ciemat, October 27 th, FPA2013ILC workshop D. Moya, I. Vila, Instituto de Física de Cantabria (CSIC-UC.
SuperB Integration SuperB Experimental hall. Related topics of Slac D&D activities.
Goals and requirements 1 st flexible geometry version Next geometry version development Conclusions and outlook A realistic and flexible VTX geometry in.
SuperB Experimental hall General considerations on the Babar experimental area Preliminary space requirements hall proposal. A floor plan. Specification.
Octobre LAL Orsay Report from the IRENG07 workshop at SLAC W. Lohmann, DESY from Septembre 17 – 21, ~ 100 participants - plenary and parallel sessions.
EC: 7 DISK concept Preliminary considerations
Straw man layout for ATLAS ID for SLHC
Towards Snowmass Jul. 13, 2005 Y.Sugimoto. Charge for Detector WGs Charge for Concept Groups: work towards a baseline design define performance criteria.
ILD Silicon Tracking Status Report
2016/12/6 Yasuhiro R&D status of a gas-compressor based 2-phase CO2 cooling system for FPCCD vertex detector 2016/12/6 Yasuhiro Sugimoto.
SPL RF coupler: integration aspects
Hcal Geometry and Assembly
- STT LAYOUT - SECTOR F SECTOR A SECTOR B SECTOR E SECTOR D SECTOR C
Assembly procedure – Inner Region
Installation step 4. (3 days)
C.Clerc ILD session, ALCPG /03/2010
LumiCal mechanical design, integration with LDC and laser alignment
SDHCAL Integration Moi j’aime bien SAFARI
Vertex Detector Mechanical R&D Design Questions and Issues
Requirements of the support mechanics
Need for Alignment Position of off-momentum proton w.r.t. beam
(A) (B) - CENTRAL SUPPORT FRAME - INFN-LNF - SPAS 1
Sub-Detector Assembly Area Summary of discussion at ALCW2015
SIT AND FTD DESIGN FOR ILD
Integration and IR Hall
BGC Collaboration Meeting –
Presentation transcript:

1 ILD inner region integration meeting M. Joré – Introduction ILD inner region integration meeting Welcome words Charge of the meeting The current concept Some constraints Some specific issues 30 th of June and 1 st of July 2010

2 ILD inner region integration meeting M. Joré – Introduction Charge of the meeting ILD must write a DBD report for 2012(extract from RD’s recom) : –Complete basic mechanical integration of the baseline design accounting for insensitive zones –Develop a realistic simulation model of the baseline design, including faults and limitations So a better understanding of the inner region is mandatory –Critical area for the simulation (huge impact of material budget) –Less advanced mechanical concept Goals of the meeting : –Sketch first solution for the inner region integration –Define the material budget to be implemented in the simulation model

3 ILD inner region integration meeting M. Joré – Introduction The agenda 30 th of June 14h00 – 15h30 Introduction (M. Joré – 20min) : presentation of the current concept, the layout, some specific issues Beam pipe issues (H. Videau – 20 min) mass, radiation length, hanging, distortions. VTX (J. Beaudot – 30 min): the detectors, their electronics, the mechanical structure, power consumption, cooling, cryostat, cables, internal and external alignment needs, hanging, etc… Discussions (20min) 15h50 – 17h30 SIT (?? – 30 min): same items as VTX, integration with VTX, etc… SIT/SET (?? - 15min) : Presentation of the alternative supporting solution FTD (?) : The interplay with SIT for the first disks, alignment needs FTD mechanical structure (D. Moya – 30 min):, the mechanical structure, power consumption, cooling, cables. Can it support the beam tube? Discussions (30min) 1 st of July 9h30 – 12h00 SIT/SET (?? - 15min) : Presentation of the alternative supporting solution Fiber Optical Sensor based environmental and structural monitor (Ivan Vila – 20 min) People with proposals for these topics should declare themselves, or propose other subjects? How are these parts hanging together? Discussions around the global structure handling the parts (VTX+SIT+FTD+BP) Integration with TPC Assembly and maintenance scenario Are there options? Summary on the materials involved and the expected mass Conclusions Plan for work. 14h00 – 17h00 Free time available for discussions

4 ILD inner region integration meeting M. Joré – Introduction The current concept TPC Beam pipe FTDSIT VTX Inner Support Structure (ISS) Fixation of ISS on TPC endplates or inner diameter VTX fixed on beam tube BP hang by small cables. Could be adjusted to beam axis. Cables/services (All?) Bellows (both sides) Tunable fixation

5 ILD inner region integration meeting M. Joré – Introduction Inner detectors assembly Step 1 : half FTD/SIT shell FTD SIT Inner Support Structure (ISS)

6 ILD inner region integration meeting M. Joré – Introduction Inner detectors assembly Step 2 : BP & VTX Questions : –A special tooling is mandatory to handle the BP Beam pipe VTX

7 ILD inner region integration meeting M. Joré – Introduction Step 3 : second half shell Inner detectors assembly Cables/services Questions : –Design of cables for BP support –Cables paths : all along the BP ? –Maintenance of VTX? –Support cables mounting?

8 ILD inner region integration meeting M. Joré – Introduction Insertion in TPC A tooling would be used for insertion in the TPC

9 ILD inner region integration meeting M. Joré – Introduction The constraints Lowest material budget of course Space is limited for the fixation to the TPC Endplate 60x60mm for the moment but probably less in a near future

10 ILD inner region integration meeting M. Joré – Introduction The constraints (2) Allow the exchange of the VTX (once a year?) Allow movement of the BT Could be mechanically adjusted Stable Stiff enough to be inserted in the TPC

11 ILD inner region integration meeting M. Joré – Introduction The issues Cables paths? –In the inner region : Along the BT? Along the TPC inner radius? –In the detector : Patch panel behind the LHCal? Along the TPC EndPlate –Rough idea about the cables and services amount? Inputs are needed for improving the ILD simulation model Cooling –What kind? Is there a cryostat for the VTX? –All the subdetectors need to evacuate the heat power they have created (integration rule = each detector are adiabatic) –Common cooling system?

12 ILD inner region integration meeting M. Joré – Introduction The issues How would be your mechanical support? –For each subdetectors Alignment : how do you do? –Mechanical precision you need? –What would be the reference? –What relative precision you need between elements? Silicon disks, VTX –What precision you need in the position measurements? –What kind of monitoring you foresee? Laser tracking? Integration of SIT and FTD : –Do we merge the first 2 disks of FTD with SIT? –How to support these 2 first disks?...