Spring 2015 INFANT HEARING PROGRAM: Introducing the AccuScreen In-service.

Slides:



Advertisements
Similar presentations
1 Data entry Presentation template for adaptation and use in medicine prices and availability survey training workshop for survey personnel Review all.
Advertisements

Web Shift Booking System
3.60 CEREC Connect Lab Import
Using the camera and the wireless microphone Howard Goldbaum 9/17/2012.
Zoll Monitor Upload Required for all ALS calls where an EKG/12 lead are performed.
Components: Sansa Clip Mp3, earbuds, USB cable, Quick Start Guide.
ECG TRAINING MODULE 3 BY BRAD CHAPMAN RCT.
LogTag Training January 2015
Using Telemedicine Equipment. Overview The ‘Big’ Picture The ‘Bigger’ Picture Equipment Setting Up A Video Conference Conducting A Video Conference Common.
University of Manitoba A How to Guide for Theatre B & C.
1 Check all equipment is included before returning. If you have an accident or the equipment is damaged or you need support please contact Blaize
Unit Test Calibration Training
StatSensor® Creatinine Operator Training Program
Teacher iPads RCSD-Getting Started Guide Cathy James- Tech Resource Teacher.
This document guides you through using the common features of the InFocus™ Mondopad™ touchscreen display located in this room. Getting Started Power Display.
Syringe Pumps. Topics  Diagrams  Principles of Operation  Applications  Safety  Operation  Preventive Maintenance  Common Failure Modes  Troubleshooting.
Limit for Title Do not exceed Limit for Subhead and content Do not exceed Overall content limit Tecton Nucleus User Presentation.
Kaleida Health Point of Care Glucometer Testing 2011
ABC’s of PowerPoint (Office 2007) Part 1: Basic Vocabulary Part 2: Cursors Part 3: Insert Your Text Part 4: Insert Your Pictures Part 5: Basic Tools &
Inventory Throughout this slide show there will be hyperlinks (highlighted in blue) follow the hyperlinks to navigate to the specified Topic or Figure.
+ USING THE POWER CHARGER AND BATTERY MINI-DV CAMCORDER Connect the charger to the power cord Attach the battery to the charger Plug it in and watch for.
Merging Duplicate Records in Family Tree. Duplicate records – why not just delete one of them? This record for Elizabeth Berry shows her as the child.
Today:. Colorado Space Grant Consortium Gateway To Space ASEN / ASTR 2500 Class #06 Gateway To Space ASEN / ASTR 2500 Class #06 T-53.
How to enable game play with the Nintendo Wii By Eli De Carteret.
A lesson approach © 2011 The McGraw-Hill Companies, Inc. All rights reserved. a lesson approach Microsoft® PowerPoint 2010 © 2011 The McGraw-Hill Companies,
Refresher Course for Nurses and Medical Assistants June 2009 © John Tracy Clinic.
Strengthening Supportive Supervision Training for Supervisors Session 3: Smartphones, introduction to SS Tool.
Cypress-Fairbanks I.S.D. 04/04/05 PC6 Word Processor Training Assistive Technology
Power Point EDU 271 Microsoft PowerPoint is a powerful tool to create professional looking presentations and slide shows. PowerPoint allows you to construct.
Nokia Bluetooth Headset BH-108 for Contact Centers
Welcome! In this Wimba Overview you will learn:  How the Wimba Support Team checks audio  How to communicate in the classroom  Features of the classroom.
Working with iMovie: The Basics Created by MJ. Importing Video Footage attach your camera to your computer and set to VTR mode move the camera button.
Setting up the Ricoh C305 Press F5 to start the Presentation
Using the PDA Links to each of the topics Go to next slide Intro to “Getting Started Changing iPAQ Settings -Setting the Time/Date -Changing Keyboard.
D & D Enterprises Session 1: Basic PDA Usage Thursday June 15, 2006 Palm Telemedicine Seminar Series.
Sony Handycam Instructions Directions Written By: Stephen Hall, Student Technical Assistant Ms. Miri Kim, Director of Instructional Design and Technology.
To Use This System To schedule a training or for classroom support, please call the Library Computing Helpdesk at WAYNE STATE UNIVERSITY -
Student iPad Configurations
How to Request Materials Tutorial Order, Borrow, Renew made easy (expected running time: ~7 minutes) Oregon State Library.
Motors and Sound Troubleshooting Tips. © H-CCS Problem 1 Why can’t I download my program to the RCX?
How to MODIFY a BUTTON and Modify Button Modify Button in the Title Bar Record button Modify button Battery gauge Memory gauge Day, date, and time Setup.
LSM780 Live Cell Turn On/Turn Off Instructions Kim Peifley 07/13/15.
 When you receive a new you will be shown a highlighted in yellow box where your can be found  To open your new just double click.
1 Stylus Power Button Power Jack USB Port Handheld Features.
Otoacoustic Emission Test. What are otoacoustic emissions? These are low intensity sounds produced by the cochlea as the outer hair cells expand and contract.
Build-It-Yourself.com BLENDER 3D LESSON 3 BLENDER 3D LESSON 3.
ACCU-CHEK Inform II Operator Training
Our Class Camera! BodyLens LCD Screen Viewfinder Built-in microphone Record Button Zoom Settings menu Power Source Ports/Jacks Hard Disk Drive.
Instructional E-Classroom Instructional Guide Seneca College, Audio-Visual Services.
2 MINUTE PEARLS Immunization Module: New and Historical Vaccines
This is what we want to produce Import sketch dimensions Label angles Set the scale Add linear dimensions.
Spring 2015 INFANT HEARING PROGRAM: New Screener Presentation.
 Charging and Syncing the iPod Touch Cart Lesson 2.
Spring 2015 INFANT HEARING PROGRAM: AccuScreen and Program - Review.
1 Philips EvoKit Lumen Selection App User Manual * Philips Lighting April 20, 2016 *Can be used for Philips EvoBase as well.
Digital Literacy Introduction to Computers Unit 1, Lesson 1.
Election Tips for the TSX The Mississippi Secretary of State’s Office, Elections Division 2012 Prepared and presented by: Derrick Cooper, Elections Systems.
Freestyle Precision Pro
Student iPad Configurations
PROGRESSIVE COMMUNICATIONS
StatSensor® Creatinine Operator Training Program
User guide for Direct Observations equipment use
Intro and T1 Troubleshooting
Meeting In A Box Set Up Guide
PUMA-5 for Law Enforcement
Automatic Test Station for GasAlertClip Extreme Portable H2S Monitors
LIFEPAK® 1000 Defibrillator Orientation Guide
Nellcor™ Bedside SpO2 Patient Monitoring System, PM100N - Home use
Presentation transcript:

Spring 2015 INFANT HEARING PROGRAM: Introducing the AccuScreen In-service

ACCUSCREEN – Getting Started The AccuScreen is a touchscreen unit that has the capability to screen using Automated Distortion Product Otoacoustic Emissions (ADPOAE) or Automated Auditory Brainstem Response (AABR) or both, depending what the configuration is. The AccuScreen is a hand-held, battery powered unit that can be charged in the docking station. The battery will be fully charged after six hours. A full charged battery will last eight hours, depending on use.

Caring for the equipment What pieces are disposable? What is the easiest way to maintain equipment? Can we prevent breaks? -Hold equipment carefully, to avoid dropping it. -Keep wires tidy, avoid knots. -Insert connections into the correct ports. ACCUSCREEN – Getting Started

To self calibrate insert the probe into the back of the unit. To turn it ‘on’ press the grey button on the side of the unit, press and hold the bottom of the button to turn it ‘off’. To remove the battery (reboot or change battery) press the battery release and the back will open. On Battery Probe Test Battery release

ACCUSCREEN – Getting Started Home page Find a Patient Create a New Patient View the Tests Print the Tests Delete Patients Quick Test to check your hearing Quality test to troubleshoot Settings to change i.e. date, time, log in

ACCUSCREEN – New Patient We do not store personal health information without encryption. Select New Patient to get a new ID and perform the test.

ACCUSCREEN – New Patient To enter a numerical ID touch ‘123’ to switch from ‘aaa’. Touch the checkmark after you entered the desired number.

ACCUSCREEN - Probe Tips and Eartips There are five disposable eartips available for use with infants; 3.7mm yellow, 4.0mm green, 4.5mm pink, 5.0mm blue and the transparent tree tip 4-7mm. A clean eartip must always be used when placing the probe tip into the ear canal. Probe Tip Eartip

ACCUSCREEN – Connecting the probe tip Click the probe tip onto the speaker cable, then slide the appropriate sized eartip on. To remove hold the probe tip at the top and bottom along the groves, push together then outward.

Babies NOT at Risk A two step process. Step one with ADPOAE equipment. Step two if needed with AABR equipment. Step two should be done as soon as possible to reduce parental anxiety. IHP – Stage One Screening

DPOAEs are generated by the outer hair cells (OHCs) of the cochlea. Normal DPOAEs usually mean that hearing is normal (at the time of screening…) Absent DPOAEs suggest that hearing may be abnormal and further testing is needed. IHP – Stage One Screening

Infants will either receive a pass or a refer result. A pass means that the baby is hearing at this time. But, it is always important to monitor. A refer does not necessarily mean that the infant has a hearing loss. Commonly, debris in the ear canal, fluid in the middle-ear or movements during the test will affect results. A referral to another stage of screening is needed. IHP – Stage One Screening

ACCUSCREEN – ADPOAE The hearing screening is a quick, easy, non-invasive screening test that does not involve the performance of any of the controlled acts under the Regulated Health Professions Act, Provision of parental consent is required, unless hearing screening is performed as part of a hospital’s standard of care. Consent to share results with the regional IHP is always required.

ACCUSCREEN – ADPOAE To screen with the ADPOAE connect the cable with the blue base. Ensure the arrows are aligned properly. Select an appropriate eartip. Put on the probe tip and eartip. Select the ear for initial screen.

ACCUSCREEN – ADPOAE Touch the black arrow to begin. The equipment will calibrate and then initiate screen. The screen is completed once three frequencies have a clear response.

ACCUSCREEN – ADPOAE The Test Menu has tests completed and test results. The Test View shows all attempts including missed calibrations and aborted tests.

ACCUSCREEN – DPOAE Errors If there is too much noise, reduce environmental noise i.e. turn off cell phones and/or check the ear for debris. You can also try a Quality Test to make sure the probe is OK.

ACCUSCREEN – AABR Soft sounds are played in the baby’s ear and the brain’s electrical response is recorded using three sensors (electrodes). The brain’s response to the sounds is automatically analyzed and interpreted by the AccuScreen.

ACCUSCREEN – AABR To conduct an AABR, connect both the green and blue cords. Make sure the arrows are aligned properly. The red electrode goes on the right mastoid. The black electrode goes on the left mastoid. The white electrode is placed on the baby’s forehead (high midline).

ACCUSCREEN – AABR Touch the black arrow in the Test Menu. Once impedance values are OK, the black arrow is highlighted, touch to start. The testing page will appear. The test is complete when the ABR bar or Progress bar is full.

ACCUSCREEN – AABR Errors If impedance values are good, the color will be green. Yellow means that the connection is not as good. Red is unacceptable. A yellow reading can turn red if the electrode is loose or falls off.

ACCUSCREEN – Troubleshooting Quality Test Before testing babies each day, a Probe Test should be done. Insert the probe into the test cavity at the back of the AccuScreen. The test will start automatically. Results will appear as ‘Probe OK’ or as ‘Probe failed’ with possible errors.

ACCUSCREEN – Troubleshooting Loose Cord Error If your electrodes appear attached but you still get poor impedance or loose cord errors, perform an Electrode Test to check the cables. Attach the electrode cable wires and check with a Quality Test to make sure they give good impedance. The Test results page will indicate the condition of the electrode cables.

ACCUSCREEN – Troubleshooting Other Errors and Solutions AABR does not start – press the triangle to start. Black screen – unit powered off (eject battery if needed). Timeout during pause – AABR was paused more than two minutes. Battery Start Not Working? Contact Genie Audio Tel: Request and record the RMA number. Fax or the completed form.