LEADING THE PACK.

Slides:



Advertisements
Similar presentations
CL100D series DSP controlled Uninterruptible power supplies.
Advertisements

What is On Time Booking? Reservation and distribution system for passenger transport companies (airlines and ferries ) Tool that helps you to manage the.
Static Transfer Switch
Model W Wall Mount Static Transfer Switch. Why choose a model W static transfer switch? Increases power availability. Integrated maintenance bypass. True.
Inputs: Digital and 4 configurable for Digital or 10 bit Analog Outputs:4 - 8 amp Relays or 700ma Transistors (1 PWM) 4 Line by 18 Character fully.
Pyronix Ltd. Secure House Braithwell Way, Hellaby, Rotherham, S66 8QY, UK T F E
Reliability Different worlds – same problem …one solution: Redundancy
LP-31 Series Uninterruptible Power Supply Product Management GE Consumer & Industrial Power Protection.
Delta Confidential Apr GAIA-series 5-11KVA Introduction.
Security Systems BU Communication Systems Slide 1 Plena Voice Alarm System Commercial Presentation.
DPA TM UPScale Best-in-class modular UPS for maximum availability.
Introducing GAC’s New Line of Intelligent Generator Set Controllers
Confidential Document 1 EverAccess Product Overview By Julian Garcia.
Phaseo Power Supplies ACE Expert Training Presentation 2009.
1  Module Type Overview  Construction  Characteristics  Installation principles  Details PD 600-Series.
Advantys® STB High Density Discrete I/O Modules. AGP - English 2 Advantys® STB Advantys STB delivers customer value in distributed I/O Smart Built-in.
Advantys ETB Ethernet IP67 I/O
1 Modular DC/DC Converter. 2 PSC W Standard 19“ rack 4U – 6 prewired slots (single DC input/output connection for each unit)
Kinetix 3 Component Servo Drive
All content in this presentation is protected – © 2008 American Power Conversion Corporation Symmetra ® LX – redundant UPS High performance, redundant.
X20 – The new Benchmark Powerpoint_Vorlage_V61D
MICA: A Wireless Platform for Deeply Embedded Networks
ASAB New Additions Extended Bypass Models Ethernet Modules Remote Control Panel.
Operator Panel and Programmable Logic Controller.
Janus Convertible Line – interactive Series UPS
AC backup solutions for business continuity. Secure your business, Stay on!
MarsⅡ On-Line UPS Series
1 PAC530 | Output Controller. 2 The Output Controller (PAC530) provides the local connection on an RS-485 network between an Access and Alarm Server (PAC500)
Single Loop Analogue addressable fire control Panel
High Sensitivity Smoke Detection
ACCESS CONTROL ExpansE - Distributed Access Control.
8000 Series Options/Technical Overview Series Precision Digital Multimeter New Technology – Multi Processor design No need for AutoCal – High precision.
PowerScale 10-50kVA Ed Maximize your availability.
LP Series U Technical presentation ISO 9001 UL CUL FCC Class A CE.
Smart Grid: Opportunities in the Data Center January 22, 2010 Charles O’Donnell, Vice President, Engineering Liebert AC Power Emerson Network Power.
Product range/ALPHA-E-0001-tri-20/04/03 ALPHA Micro Controllers A single multi-functional unit instead of multiple components ALPHA / ALPHA XL Products/ALPHA.
Page 1 LXMG , LXMG LXMG , LXMG PanelMatch™, StayLit™ Dual Lamp CCFL Inverter Modules Training.
YASKAWA VS-606 V7 COMPACT VECTOR - CONTROLLED INVERTER FOR GENERAL USE 230V (Single-Phase).1Kw ~ 3.7Kw (.13HP ~ 5HP) 230V (Three-Phase).1Kw ~ 7.5Kw (.13HP.
Franklin Electric - The Company You Trust Deep Down Provides The Ultimate Protection for Your Pump & Motor! Franklin SubMonitor.
the compact air control solution
Make the most of your energy December 2008 HDM Accurate measurement and electrical utility cost allocation for multi-tenants PowerLogic ® High Density.
Confidential Document 1 EverAccess Product Overview By Rodney Guinto.
Page 1 LXMG PanelMatch™, StayLit™ Dual Lamp CCFL Inverter Module Training Kit Rev 1.1 November 2006
1 Powerware kVA The modular, scalable, redundant UPS for midrange applications.
Alarm units AL 175 NT and Aeon Gold For small, medium and large power range.
PRO-H Power Supplies. PRO-H Series  P owerful R eliable O ptimized - H azardous Areas  Complete family of Power Supplies 1-phase 3.8A up to 25A  Output.
AEON 4000 Including the SMPS 4000 rectifier and the AEON Gold Alarm & Monitoring Unit.
Avaya 9130 and 9135 Online UPS 1000 to 6000 VA. Avaya Applications Advanced power protection for: u S8700/S8500/S8300/S8100 Media Servers u Unified Communications.
FLATPACK Rev.5 September 2002 Updated versions may be available.
CompactLogix Controllers Portfolio
Top 10 Differentiators.
InfraStruXure Systems Alex Tavakalov
April 24, 2015 FlexBus TM and FlexCards TM. 2 © Red Lion Controls Inc. FlexBus What is FlexBus?  A parallel bus that expands the option card capability.
Exit REMOTE POWER SYSTEM ”Turning your copper into gold”
Aeon Gold – System Overview *TCP/IP *SNMP Aeon Gold Display Unit *Advanced setup and *monitoring through *WinPower *SW Download PC w /WinPower Aeon 4000.
Exit LEADING THE PACK Eltek 2 UNLEASHING THE LEADER OF THE PACK.
Avaya VA Line-interactive UPS
PowerValue 11 RT Sales Presentation
Maximize your availability
PowerValue 11/31 T Sales Presentation
Best-in-class modular UPS ensuring business continuity
Smart battery management
The smart choice for demanding motor switching
Presentation transcript:

LEADING THE PACK

UNLEASHING THE LEADER OF THE PACK

Perfecting success Flatpack 700/1500/1800 has been the most successful rectifier in the market over the last 2-3 years. 160 000 units sold in 2004!! Changing customer requirements NOW IS THE TIME TO TAKE THE NEXT STEP Short applause!!!!

THE LEADER OF THE PACK

Quantum leaps Power density Digital Controllers Cost Expanded Flexibility

More for less Initial investment Life-time Cost Efficiency/Efficiency management Less space Reliability

Components Solutions The Flatpack 2 Rectifier The Smartpack Monitoring and Control Unit System Solutions

The Rectifier that Stands Out! Flatpack 2 The Rectifier that Stands Out!

Flatpack 2 The ultimate building block in Telecom Power systems With the module size and cost efficiency the Flatpack 2 can be used in applications ranging from 1 kw to several 10s of kWs. There is no reason not to design systems in excess of 50kW as the cost is competitive on both system and module. This range of power covers the mayor part of any operators network.

Ultra compact Power 1800W 37,5A @ 48V 4 accross in 19 1220W/liter 21W cubic inch 37,5A @ 48V 4 accross in 19 150A/7,2 kW pr unit height (U)

Leading technology Digital controller Low component count Flexible design Topology Resonant half bridge Reduced component count Can bus communication Monitoring Module control Efficiency management

Reliability Reduced component count MTBF >400 000 hrs (theoretical) Flatpack 1500/1800 Theoretical 250.000hrs Experienced > 106 hrs 20ms hold-up

Other facts Input 85-290 Efficiency 93% Global approvals Nominal 185-275 Protective disconnection >290VAC Efficiency 93% Global approvals ROHS compliance In 2005 1800W 700W 85 185 290 Output Power vs. Input voltage

Outstanding Monitoring & Control Smartpack Outstanding Monitoring & Control

Smartpack Scaleable and flexible control module for the entire Eltek product range

Smartpack 2x16 character display Keypad USB front connection CAN bus communication Latched contactors Scalable to match specific requirements. Advanced and wide range of functions.

Scalable LEGO approach External Add-on features (future) Basic Standard Extended External Add-on features (future) Advanced battery monitoring External distribution monitoring External I/O Etc.

Functionality Front panel LCD and key pad USB (or RS 232)for PC connection 6 user programmable relay outputs 6 user programmable inputs Battery monitoring and testing Temperature compensated charging Battery lifetime indication Alarm/event log (1000) with time and date Windows-based PC communication software And much more

Power Suite Explorer oriented easy to use PC SW USB gives simple access. Wide functionality with clear graphic presentation.

Power Suite

Power Suite

Power Suite

Power Suite Battery management

Power Suite Up & Download

Power Suite Alarm handling

Flatpack Power Solutions How much power do you need?

System variants Integrated Cabinetized Outdoor For integration into other equipment Cabinetized Utilising the cabinet structure Wide range of power ratings and configurations Outdoor Utilise experience with from different projects to create a varied portfolio. Utilise compact module creatively for space saving solutions. More ”global” building blocks

System design

Integration 150A/2U 2 x batt MCB (Max 100A) 6x load MCB (Max 32A)

Integration Up to 600A 4U distribution

Open frame Up to 600A Cost efficient Good ventilation

Cabinetized Flexible design Multiples of 150A Cost efficient Based on standard configurable building blocks Variety of cabinets available

Cabinetized 1500A – 72kW Is this the upper limit? 10U, 40 rectifiers No technical restraint

What do you want powered? Application Matrix What do you want powered?

Typical applications

Customer benefit Leading edge products for the future Competitive total offering Global availability of global products