DC Inverter Mini VRF Reference projects Reference Project Mini and Multi Improvements Product line -up.

Slides:



Advertisements
Similar presentations
AIRCONDITIONER ERROR CODES
Advertisements

CMV Mini VRF SYSTEM R410a, 50Hz.
Packaged Terminal Air Conditioners
Operating Functions.
Daikin Altherma™ Troubling Shooting
Fan Coil Unit Product Line-up. FCU Home Application Show.
SINGLE SPLIT INVERTER AIR-CONDITIONER
Total HVAC Control from anywhere Easy control that can save a fortune
Panasonic Expérience Leadership in Japon : CO2 Models Most famous manufacturer of compressor in the world(high technology of inverter) High experience.
WIRED TYPE MULTI ZONE FANCOIL CONTROL SYSTEM MODEL : WSF- 700 SYSTEM
Trane Variable Water Flow System
= ( es ) 2 energy savings. 53% SAVINGS* THAN OTHER LEADING INVERTERS! Best Energy Savings! High 11+ EER CASSETTE INVERTER FLOOR STANDING INVERTER HIGH.
① The output signal of a room thermostat is ON or OFF according to changes of room temperature ② The power supply to a motorized valve is ON or OFF according.
Copyright ⓒ 2008 All rights reserved LG Electronics Inc. Daikin VRV III vs LG MULTI V Plus II.
1 Introducing Energy-saving Hydraulic Units March 2006 Fujikoshi Corporation For publication.
WMV-SERIES MODULAR DC INVERTER VRF ALWAYS BETTER CAC SOLUTION FROM GREE.
Cooling Only 38MFC/ 40MFC Heat Pump 38MFQ/ 40MFQ
Product Introduction.
Daikin Australia Pty. Limited Ducted Split Systems 2011.
The new Super Multi from TCUK
Heat Recovery Ventilator Be used with AC system, Create a healthy life.
Learning, our way Examples of bad installation. CONTENT Installation related examples Installation related examples Application related examples Application.
Perfect solution for large building
2007 New Product: Floor Standing Unit FVXS-F Sep-15 Public Reviewed by Strategic Marketing DENV Product Concept  Stylish and Compact design  New.
Air conditioning – Refreshes your life EWTP MBY Applied Systems Sales1 EWTP-MBYNN Air-cooled Heat Recovery.
Air Conditioning and Computer Centre Power Efficiency The Reality Christophe Martel Tony Cass.
1 © Copyright DWT GROUP 1 DWT reserve the right to make modifications without prior notice.
Keith Clark NSM VRF Commercial VRF. What’s Different About Our Ductless Products? Ductless Mini-Split Technology Not Much.
Page 1 Air-cooled Inverter Product Range Updated by: Yap Boon Thiam Technical Engineer Date: 14/5/2012.
 Better interior design  Space saving  Comfort living environment “Multi V space” for Premium apartment.
Learning, our way Daikin Europe, Consulting sales section1 Understanding Client’s Needs and best Daikin solution.
Product Presentation 2007 SKY AIR Launch of new Non-Inverter + Duct (R22) series.
Product Section Product Training. 50 Hz R410A R22 R407C Ceiling Convertible CE-E Series.
TECHNICAL TRAINING INVERTER-Y
Pressure-Enthalpy and the Variable Refrigerant Cycle
Large Tonnage Chiller AC Screw. Content Mechanical System Key Components Control Logic Application 2.
Introduction of New Wall Mounted AVS 18-24URCSBBA Commercial Air Conditioning Dept
Hisense New Hi-wall IDU AVS-07~17URCSABA /30.
1  2008 Kaeser Compressors, Inc., USA (V2.2) “Specifications are subject to change without notice” Presenting... Kaeser Omega Blowers.
© 2012 MITSUBISHI HEAVY INDUSTRIES – MAHAJAK AIR CONDITIONERS CO., LTD. All Rights Reserved. Bad case of Installation RAC-B-A07.
Refrigerant system of Inverter R-410A. denki.co.th Model type Model : Stand Model : Duct Model : Cassette Model : Wall mount Model : Wall and.
2016 Chiller New Products Presentation.
Air condition installation
Integrated Blower Packages Kaeser Integrated Blower Family.
James McIntyre VRF Training Manager V5 Key Components.
Refer to Service Manual for details Fault codes. To retrieve fault codes from the remote controller Press the ‘CHECK’ button for approximately.
2013 CHIGO Product CHIGO CMV VRF Control System.
CHIGO HVAC Product Introduction.
Fan Coil Controller FC/S 1.1
The New Digital Inverter Light Commercial Range
The New C55* CPVSd 10-20hp People. Passion. Performance.
CHIGO VRF System Commissioning.
Specializing in Water-Cooled & Portable-Split Air Conditioner
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
DC Inverter Air-cooled Chiller Aqua Tempo Super II Series
High Pressure screw compressor
Heat recovery feature Competitive approach
VED and VEDI VED and VEDI.
Toshiba S-MMS vs LG MULTI V Plus II
SHANGHAI ROTORCOMP COMPRESSOR ONLY USE.
FCI and FCX Range FCI and FCX Range.
FCI and FCX Range FCI and FCX Range.
FCI and FCX Range FCI and FCX Range.
VITALITY Large Splits Johnson Controls PowerPoint Guidelines | July 21, 2009.
Ceiling Convertible (ACC75~100D Series)
Total HVAC Control from anywhere Easy control that can save a fortune
Error codes for split systems
Liebert DSE High efficiency thermal management
Ceiling Convertible (MCC075~100D Series)
Presentation transcript:

DC Inverter Mini VRF Reference projects Reference Project Mini and Multi Improvements Product line -up

DC Inverter Mini VRF Outdoor Unit 42/48/60Kbtu/h 12/14/16kw 42/48/60Kbtu/h 12/14/16kw 36Kbtu/h 10.5kw

DC Inverter Mini VRF Outdoor Unit Model Capacity Kbut/h Power MDV-V80W/N V 50Hz 1 phase MDV-V105W/N1 36 MDV-V105W/N1-B 36 MDV-V140W/N1 48 MDV-V105W/BDRN V 50Hz, 3phase MDV-V140W/BDRN148 MDV-V160W/BDRN1 60 MDV-V160W/BDRN1-B Product line-up

DC Inverter Mini VRF Outdoor Unit Model Capacity Kbtu/h Power MDV-V105W/DMN V 60Hz, 1 phase MDV-V105W/DMN1-B 36 MDV-V140W/DMN1 48 MDV-V160W/DMN1 60 MDV-V140W/DDN V 60Hz,3phase MDV-V160W/DDN1 60 MDV-V105W/DCN V 60Hz,3phase MDVC-V105W/DCN1 MDV-V140W/DCN1 48 MDVC-V140W/DCN1 MDV-V160W/DCN1 60 MDVC-V160W/DCN1 Product line-up

DC Inverter Mini VRF Outdoor unit Power36Kbtu/h42Kbtu/h48Kbtu/h60Kbtu/h 220~240V 50Hz 1phase 2011Dec.Available 2011Dec. 208~230V 60Hz 1phase Available on 2012 May. 380~415V 50Hz 3phase Available on 2011 Dec. 380~415V 60Hz 3phase Available on 2012 May. Product line-up Full DC Mini

DC Inverter Mini VRF Outdoor unit Model Status 62Kbtu/h 18KW Under developing 68Kbtu/h 20KW Full DC Mini

DC Inverter Mini VRF Outdoor Unit Nomenclature Product line-up

DC Inverter Mini VRF Indoor Unit Nomenclature Product line-up

DC Inverter Mini VRF Indoor Unit Product line-up

DC Inverter Mini VRF Indoor Unit Indoor Unit ( kW ) (KBtu/h) Four-way Cassette Compact √√√√√ New Four-way Cassette √√√√√√√√√ Low static Pressure Duct √√√ Duct √√√√√√√ Ceiling & Floor √√√√√√√√ Wall-mounted √√√√√ Exposed Floor-standing √√√√√√√ Concealed Floor-standing √√√√√√√ Product line-up Notice: If one ODU connect more than two or more IDUs, the capacity of each IDU should be within 8kw

What improvements are realized Improvements Installation and maintenance Control and function Efficiency and performance

Key component of the outdoor unit Efficiency and Performance Mitsubishi Electric double rotor compressor High efficiency DC inverter Optimize compressor drive technology Wider operating frequency range Compact structure Better balance and lower vibration

Efficiency and Performance Key component of the outdoor unit Panasonic DC fan motor : Wider fan speed adjustment lower noise lower power consumption

Efficiency and Performance Optimally design the fan shape and air deflector, which increase the air volume and reduce the running noise Key component of the outdoor unit CFD

The efficiency of the oil separator is 99%, it is good for the longer piping Efficiency and Performance

DC Inverter Mini VRF Grilling design to keep well ventilation for control parts. Efficiency and Performance

Outdoor unit 12KW Cooling capacity Heating capacity IPLV Midea Daikin Mitsubishi Toshiba Gree Efficiency and Performance

Outdoor unit 14KW Cooling capacity Heating capacity IPLV Midea Daikin Mitsubishi Toshiba Gree Efficiency and Performance

Outdoor unit 16KW Cooling capacity Heating capacityIPLV Midea Daikin Mitsubishi Toshiba Gree Efficiency and Performance

Wider operation temp. range 5F118F Cooling 81F Heating In cold winter…… 5F Efficiency and Performance

What improvements are realized Installation and maintenance Control and function Efficiency and performance Improvements

Control and function Improved oil Return Program Automatically operation oil return program Cooling modeHeating mode Indoor unit in cooling mode or fan only mode: indoor fan keeps running; Indoor unit in standby mode: indoor fan will not run. Indoor unit in heating mode: indoor fan is controlled by anti-cold air function; Indoor unit in standby mode: indoor fan will not run. Oil return program will start after system has been running for 8 hours. During oil return program, indoor unit which is in standby mode, indoor fan will not run

Control and function Auto addressing setting   Outdoor unit will automatically distribute the address to indoor units without any manual settings;   Wireless controller can enquiry and modify the address of each IDU. 00# 01# 06# 02# 04#05#

Control and function Network control  Connect ammeter and CCM02 and NIM06 to Mini VRF to achieve power consumption calculation

Control and function Network control   Connect ammeter and CCM02 and NIM06 to Mini VRF to achieve power consumption calculation

What improvements were realized Installation and maintenance Control and function Efficiency and performance Installation and maintenance

14KwDimensions Dimensions ratio Midea new design 900×1327× % Midea old design 940×1245× % Daikin 900×1345× % Toshiba 900×1340× % Mitsubishi 950×1350× % Space Saving Installation and maintenance

DC Inverter Mini VRF Easy piping connection Branch pipe Four divergence box Installation and maintenance

Variouse optional direction to connect copper pipe Front side Left side Installation and maintenance Rear side

Features Stop valve is built in the ODU to prevent stop valve damage in transportation Notice: now only compliance with 12/14kw 50Hz,1ph Installation and maintenance

Features Installation and maintenance Reasonable pipe design make maintenance more convenient

LED display Check button Installation and maintenance Self system diagnosis

System diagnosis Display Malfunction or Protection E0EEPROM malfunction E2Communication malfunction between indoor/outdoor units E3Communication malfunction in outdoor PCB E4T3&T4 temperature sensor malfunction E5Outdoor unit voltage protection E6Dc fan motor malfunction E7 A fan in the A region run for more than 5 minutes in Heat model P0Top shell temperature of compressor protection Installation and maintenance Self system diagnosis

P1High pressure protection P2Low pressure protection P3Compressor current protection P4Compressor discharge temperature protection P5Condenser high temperature protection P6IPM protection P7Evaporator high temperature protection Installation and maintenance Self system diagnosis

Mini and Multi II. Mini VRF Series I. Inverter Multi Series

Mini and Multi Pipe Pipe length Price Installati on Applic ation IDUControl Combin ation Mini1group100mHigher Same as VRF Wider Same as VRF Central and net control Free Multi 1-4 group 5mLower Same as split AC Limit Special IDU Only individual control Lot of limitatio ns Comparison

DC Inverter Mini VRF

DC Inverter Mini VRF

DC Inverter Mini VRF bedroom parlour dining room guest room workroom Free design Free combination Perfect Perfect collocation

DC Inverter Mini VRF Thank you!