The world leader in serving science For Research Use Only. Not for use in diagnostic procedures Quantitative Analysis of 4 Immunosuppressant Drugs in Whole.

Slides:



Advertisements
Similar presentations
Orbitrap Mass Analyser - Overview and Applications in Proteomics
Advertisements

Improvements in Mass Spectrometry for Life Science Research – Does Agilent Have the Answer? Ashley Sage PhD.
1 The world leader in serving science Proprietary & Confidential WiSIM DIA Method Set-up Orbitrap Fusion MS MS Instrument Control Software v.1.1 SP1.
Screening of Cocaine and Its Metabolites in Urine December 9,2009 Ho Yan Yip Chem
Analyte desorption and its resulting impact on sensitivity is better when centrifugation is adopted in comparison to soak for one hour for both basic and.
C.Bi 1, Y.Yamaguchi 1, S.Bamba 1, H.Kumada 2, K.Nakai 3 and T.Morimoto 1 1 Research and Development Office, Japan Chemical Analysis Center 2 Proton Medical.
World Health Organization
LC-MS Based Metabolomics. Analysing the METABOLOME 1.Metabolite Extraction 2.Metabolite detection (with or without separation) 3.Data analysis.
11 Determination of the Levels of Fungicides on Citrus Fruits By Miseung Borgers Chem 4101, Fall 2008.
LC/MS WORKSHOP IOWA STATE UNIVERSITY Kamel Harrata  Instrument Description  Data Acquisition  Data Processing.
Investigation of Oxidative and Conjugative Metabolism Reactions with Liquid Chromatography / Accurate Mass High Resolution Mass Spectrometry Maciej Bromirski.
Instant Notes Analytical Chemistry
FIGURE 5. Plot of peptide charge state ratios. Quality Control Concept Figure 6 shows a concept for the implementation of quality control as system suitability.
LASER DIODE THERMAL DESORPTION IONIZATION SOURCE FOR MASS SPECTROMETRY Patrice Tremblay, Ph.D.
Chapter 22 GC & LC Gas Chromatography 1.Schematic diagram.
High Performance Liquid Chromatography (HPLC) Jeannette Comeau CHEE April 2004.
Mass spectrometry Ions are analyzed on the basis of their m/z Chlorine has 2 isotopes, 35 Cl and 37 Cl, in the approximate ratio of 3 :1. Electrons are.
Q-Exactive LC-MS. TurboFlow technology - Special columns - Complex valving - Extra pump UHPLC -Fast separation -Best separation.
Orbitrap Technology: New Frontiers in Pesticide Residue Analysis
Peak-purity by LC-MS and LC-DAD Knut Dyrstad Erlend Hvattum Sharon Jara Arnvid Lie.
Using Linear Scale-up Principles and the Varian 940-LC with Scale-Up Module for the Isolation of 5-Hydroxytryptophan from Griffonia Simplicifolia Dennis.
Integrated Targeted Quantitative Method for Insulin and its Therapeutic Analogs Eric Niederkofler 1, Dobrin Nedelkov 1, Urban Kiernan 1, David Phillips.
Additional file 1 1.1Workflow of large-scale proteomic analysis of normal human kidney glomerulus 1.2Detailed procedure of LC-MS/MS analysis Additional.
DEVELOPMENT OF A RP-HPLC METHOD FOR THE DETERMINATION OF METFORMIN IN HUMAN PLASMA.
In Figure 3, and using the same reasoning for THC, the LOQs for cocaine (coc), MDMA, methamphetamine (meth), and amphetamine (amp) are estimated to be.
Summary of Analytical protocols used for Dye and organic pigment analysis Maarten van Bommel.
MS Calibration for Protein Profiles We need calibration for –Accurate mass value Mass error: (Measured Mass – Theoretical Mass) X 10 6 ppm Theoretical.
Intensive General Chemistry Chemical separations II Isabelle Vu Trieu
Polybrominated diphenyl ethers by HRGC/HRMS Coreen Hamilton Brian Fowler Louis Haviland Axys Analytical Services, Ltd.
Finding a Needle in a Haystack: Using High Resolution Mass Spectrometry in Targeted and Non Targeted Searching for Food Contaminants Erik Verschuuren.
* CORRESPONDING AUTHOR Glucagon Bioanalysis by LC-MS: “Unprecedented Level of Sensitivity (10pg/mL) for a Novel Formulation” Jean-Nicholas Mess 1, Louis-Philippe.
Improving the Detection of Hydrophilic Peptides for Increased Protein Sequence Coverage and Enhanced Proteomic Analyses Brian S. Hampton 1 and Amos H.
液相層析質譜分析 LC-MS Method development and Analyte Identification 授課教師:賴滄海教授 授課教師:賴滄海教授
Validation Defination Establishing documentary evidence which provides a high degree of assurance that specification process will consistently produce.
LC/MS Chromatography Systems 212-LC. 2 The Complete Solution Varian LC components, pumps, autosamplers and the New MS Workstation SW (V6.6) can be used.
PERFLUORINATED CARBOXYLIC ACIDS AND SULFONIC ACIDS IN WASTE SAMPLES Katsuya Y 1 *,Takemine S 1, Matsumura C 1, Tsurukawa M 1, Haga Y 1, Fujimori K 1, Nakano.
LTQ Orbitrap Series: Calibration, Tuning, Operations
Presentation overview
THC in Oral Fluid by LC-MS/MS Kristine Van Natta 24 Sep 2010.
Determination of metformin in urine (by Liquid Chromatography LC)
Toxicological Screening of 80 Drugs in Urine Using the High Resolution Exactive LC/MS Orbitrap Mass Spectrometer Coupled to Online Extraction and Turbulent.
Introduction to Liquid Phase Mass Spectrometry
3M Drug Delivery Systems 3 Introduction A family of hydrofluoroalkane-compatible excipients based on oligomeric lactic acid (OLA) has been proposed for.
Data independent acquisition methods for metabolomics Stephen Tate, Ron Bonner AB SCIEX, 71 Four Valley Drive, Concord, ON, L4K 4V8 Canada A high resolution.
GUY’S & St THOMAS’ FOUNDATION TRUST A simple and rapid method for quantifying total and free Mycophenolic acid and its glucuronide metabolite using Electrospray.
L’innovazione Scientifica per la Nutrizione La statale per EXPO, Lodi 16 Ottobre 2015
Forensic Toxicology Use Only Analysis of ETG, ETS using the Thermo Scientific Exactive Mass Spectrometer Kent Johnson Fortes lab, Portland Oregon.
Target Analyses in Parallel Reaction Monitoring Mode (PRM)
H M Arif Ullah, Hye Jin Chung*
Plasma Free Metanephrines Analysis using LC-MS/MS with Porous Graphitic Carbon Column Xiang He (Kevin) and Marta Kozak Thermo Fisher Scientific.
Metabolomics Part 2 Mass Spectrometry
Multi-Analyte LC-MS/MS Methods – Best Practice.
James Byrd, Marta Kozak 28 Apr 2011
20l of whole blood + 80 l of water +80 l of 0.1M ZnSO4
Introduction Results Aim of the study Methods Conclusion References
Acknowledgements Slides and animations were made by Dr. Jon Karty Mass Spectrometry Facility Indiana University, Bloomington.
For Forensic Toxicology use Only
LC-MS/MS Analysis of Tetracycline antibiotics in Honey using Advance UHPLC-EVOQ™ SIMA LAB PVT LTD.
A sensitive and repeatable method for characterization of sulfonamides and trimethoprim in honey using QuEChERS extracts with Liquid-Chromatography-Tandem.
HPLC Equipment : Detectors
For Research Use Only. Not for use in diagnostic procedures
Clinical Research Use Only Not For Diagnostic Purposes
Analysis of Anamorelin Stereoisomers in Human Plasma Using Coupled
Metabolomics Part 2 Mass Spectrometry
DETERMINATION OF ESTROGENIC STEROIDS IN SEWAGE SLUDGE SAMPLES FROM EIGHT DOMESTIC WASTEWATER TREATMENT PLANTS Jana Petre, Toma Galaon, Vasile Ion Iancu,
524.3 Purge Flow Study Anne Jurek – Sr. Applications Chemist
High Resolution Quantitation of Microcystins with SCIEX X500R QTOF System KC Hyland.
Metabolomics: Preanalytical Variables
Simultaneous determination of creatinine, iohexol and p-aminohippuric acid in animal plasma by ultra-high-performance liquid chromatography–tandem mass.
Damiana Gentili Qualified Person/QU Director 09/05/2019
Presentation transcript:

The world leader in serving science For Research Use Only. Not for use in diagnostic procedures Quantitative Analysis of 4 Immunosuppressant Drugs in Whole Blood Using Exactive System Clinical Research Applications Group Thermo Fisher Scientific San Jose CA

2 For Research Use Only. Not for use in diagnostic procedures Presentation Overview  Goal  Introduction to Exactive  Sample Preparation and LC/MS Method for ISD Drugs  Linearity, LOQ and Results on QCs  Conclusions  Appendix ISD: Immunosuppressant Drugs

3 For Research Use Only. Not for use in diagnostic procedures Goal  Evaluate Exactive for quantitation of Tacrolimus, Sirolimus, Everolimus and Cyclosporin A in whole blood

4 For Research Use Only. Not for use in diagnostic procedures Exactive System Introduction

5 For Research Use Only. Not for use in diagnostic procedures Exactive Benchtop LC-MS Resolution 100,000 at 1 scan per second 10,000 at 10 scans per second Mass accuracy Sub ppm Dynamic range >10,000 within a spectrum Scan speed Up to 10 scans per second Mass range m/z Polarity switching One positive and one negative scan < 1 second (25K Resolution)

6 For Research Use Only. Not for use in diagnostic procedures Orbitrap – Principle of Operation z φ Hyper-logarithmic potential distribution: “ideal Kingdon trap” r Makarov A. Anal. Chem. 2000, 72,  Characteristic frequencies: Frequency of rotation ω φ Frequency of radial oscillations ω r Frequency of axial oscillations ω z

7 For Research Use Only. Not for use in diagnostic procedures Ethinyl-Estradiol at Different Mass Resolutions Resolution: 10k, 30k, 50k, 100k m/z Relative Abundance Ethinyl-Estradiol, Butyl-Phthalate, (ubiquitous background ion) Note:Ethinyl Estradiol used just to demonstrate the power of resolution

8 For Research Use Only. Not for use in diagnostic procedures 100 ppb Hormone Sample (500 pg on-column) 100 ppb Hormone sample different resolution settings Ethinyl-Estradiol The isobaric phthalate background ion interferes with the Ethinyl-Estradiol ion. At resolution of 10,000 the steroid mass is shifted because the isobaric ions are not resolved Time (min) Relative Abundance RP = 10,000 Phthalate Estradiol Time (min) Relative Abundance RP = 100,000 Phthalate Estradiol Note:Ethinyl Estradiol used just to demonstrate the power of resolution

9 For Research Use Only. Not for use in diagnostic procedures Sample Preparation and LC/MS Method for ISDs

10 For Research Use Only. Not for use in diagnostic procedures Sample Preparation Vortex 50 uL blood uL of protein precipitation solution containing internal standards Centrifuge RPM Supernatant 50 µL inject Sample Preparation Shake for 30 min Note: Same sample prep procedure for standards, QCs and samples Internal Standards Add 1 volume of 0.2 M ZnSO4 2 volumes of 20ng/mL Ascomysin and 250 ng/mL of Cyclosporin D in Methanol Precipitation Solution Prep Acsomycin for Tacrolimus, Sirolimus and Everolimus Cyclosporin D for Cyclosporin A

11 For Research Use Only. Not for use in diagnostic procedures Calibration Standards in Whole Blood Calibration Standards CalibratorTacrolimus (ng/mL)Sirolimus (ng/mL)Everolimus (ng/mL)Cyclosporin A (ng/mL) Cal Cal Cal Cal Cal Cal QC Samples – Expected Concentration QC sampleTacrolimus (ng/mL)Sirolimus (mg/mL)Everolimus (ng/mL)Cyclosporin A (ng/mL) QC QC QC

12 For Research Use Only. Not for use in diagnostic procedures  LC method 10 x 2.1 mm id packed with 5 µm, C18 guard column A: water containing 10 mM NH4FA and 0.1% formic acid B: methanol containing 10 mM NH4FA and 0.1% formic acid C: ACN/IPA/Acetone = 45/45/10 v/v/v Column Temp: 80 Deg C  Exactive MS method APCI source Full scan MS acquisition ,000 Resolution External mass calibration Extract chromatogram for drugs of interest better than 5ppm mass accuracy Confirm the identity using mass accuracy and RT Quantitate using peak area in the chromatogram Exactive – LC/MS Method Note: See appendix for details

13 For Research Use Only. Not for use in diagnostic procedures Linearity, LOQ and Results on QCs

14 For Research Use Only. Not for use in diagnostic procedures Linearity and Accuracy Standard% Difference 0.97 ng/mL ng/mL ng/mL ng/mL ng/mL ng/mL3.88 Standard% Difference Excellent Linearity and Accuracy Tacrolimus Sirolimus

15 For Research Use Only. Not for use in diagnostic procedures Excellent Linearity and Accuracy Everolimus Cyclosporin A Standard% Difference Standard% Difference Cyclosporin A Y = *X R^2 = W: 1/X^ Area Ratio Note: The 1.95 ng/mL Evrolimus standard was excluded Linearity and Accuracy

16 For Research Use Only. Not for use in diagnostic procedures Low and High Concentration Note:Chromatograms reconstructed with m/z accuracy of 5 ppm 0.97 ng/mL 53.9 ng/mL 0.94 ng/mL 49.9 ng/mL 1.02 ng/mL 51.6ng/mL 9.8 ng/mL 2067 ng/mL TacrolimusSirolimusEverolimus Cyclosporin A Excellent Specificity and Peak Shapes

17 For Research Use Only. Not for use in diagnostic procedures QCs – Performance Statistics Excellent Accuracy and Precision Everolimus Cyclosporin A Tacrolimus Sirolimus

18 For Research Use Only. Not for use in diagnostic procedures Conclusion  Exactive system operated in full scan 50,000 resolution Has high specificity for analysis of drugs in whole blood Has required linearity and LOQ Is capable of accurate quantitation of immunosuppressant drugs for research

19 For Research Use Only. Not for use in diagnostic procedures Appendix

20 For Research Use Only. Not for use in diagnostic procedures Ionization source parameters Exactive Mass Spectrometer IonizationAPCI, positive, Ion Max™ source, Discharge current 4.0  A Vaporizer temperature (deg C)300 Sheath gas (arb) 15 Ion Sweep Gas Pressure:0.0 Aux gas (arb) 17 Capillary temperature (deg C)275

21 For Research Use Only. Not for use in diagnostic procedures Exactive: Instrument Method Polarity: Positive Microscans: 1 Resolution: High (50 000) Target: Balanced Max Inject time: 250 Scan range: Divert valve: switch events min – to waste – to detector – to waste

22 For Research Use Only. Not for use in diagnostic procedures LC method  LC Conditions CTC autosampler and Accela pump Mobile Phase A: water containing 10 mM NH4FA and 0.1% formic acid B: methanol containing 10 mM NH4FA and 0.1% formic acid C: ACN/IPA/Acetone = 45/45/10 v/v/v Column 10 x 2.1 mm id packed with 5 µm, C18 guard column Column temperature: 80 deg C Injection volume: 50 µL Gradient Time (min)%A%B%CFlow rate (  L/min)

23 For Research Use Only. Not for use in diagnostic procedures Autosampler method