Horizon Icemaker for Vision Satellite-fill Installation Installation Best Practices To navigate through the presentation, press the → and ← keys on your.

Slides:



Advertisements
Similar presentations
AV Controls in the Conference Rooms Trying to Navigate the Changes.
Advertisements

Engineer Training Installing the UV Lamp TJ8300 / TJ8500 Installing the UV Lamp.
Chapter 4 Air-Conditioning Components
Step 1: Digging a Cellar On land, a majority of wells begin with digging a cellar from three to fifteen feet in depth. The purpose of a cellar is to align.
Circulating Water System
ADX 150 – Engine Repair ADX 170 – Climate Controls
Refrigerators.
Purpose Body Making module is designed for bending the laminated foil film in the shape of a tube, for welding the side seam and for cutting bodies with.
Ice. Pure and Simple ™ Welcome to the Ice-O-Matic ® on-line training modules.
Basic Refrigeration Cycle
Ice. Pure and Simple ™ Welcome to the Ice-O-Matic ® on-line training modules.
Installation. Indoor Unit Installation Typical Installation.
Click on this image to open the full PDF document.
College of Education 103 Conference Room The Multimedia Podium.
MyLock 644D Service Seminar.
ICRA Panel System Installation Instructions
DR-2000 Customer Benefits Security; Tamper resistant programming protects your customer and you! Low maintenance, long battery life & long squeeze tube.
TrueSTEAM™ Humidification Systems Module 3: Basic Installation.
TrueSTEAM™ Humidification Systems Module 4: Advanced Installation.
Shoulder Circles While seated or standing, rotate your shoulders backwards and down in the largest circle you can make.
“MAKING YOUR FITNESS OUR BUSINESS!!” Training Out Enterprises.
The Mondial Forni Mondial and Ecomondial steam tube fixed deck ovens, gas or gasoil heated, are composed of independent decks with standard working height.
PEUGEOT 206 INSTALLATION 99’— 05’ TU5JP4
Welcome to the Ice-O-Matic® on-line training modules.
© 2012 Rinnai America Corporation Rinnai Circ-Logic (RCL)
Pump Installation Vigyan Ashram, Pabal.
Installation. Indoor Unit Installation Typical Installation.
STEAM HEATING.
Shoulder & Back 10 Minute Metabolism Booster A 1.Jumping Jacks: 10 reps 1. Begin by standing with your feet together and arms at your sides. Tighten your.
COMMERCIAL SERIES TRI-POINT ANCHORING SYSTEM
Learning, our way Examples of bad installation. CONTENT Installation related examples Installation related examples Application related examples Application.
HVAC523 Circulator Pumps.
Technical and Installation 1. What will my slot depth/size for the bottom track need to be? The slot depth for standard flush tracks and full drainage.
DROP IN ANCHOR DETAIL COMMERCIAL SERIES LIFTS INSTALLATION MANUAL Drop In Anchor/COMMERCIAL SERIES.
Installation. Indoor Unit Installation Typical Installation.
How to Build Your Playhouse. September 08, 2006 By Kay Adams, Tamecha Buck, Janet Herron & Lisa Weston “Click on pictures”
SUPPORT FUNCTION 1-1. SBS installation will be done same time by product specialist Loading & Unloading will be taken care for safe handling of.
Quick Start Guide DRAFT. 1.Prepare Laundry Check pockets for small loose items. Close zippers and fasten hooks. Separate whites, darks, light colors,
Preventing Silicosis in the Mining Environment. 1.Prevention of Silicosis to Improve Mine Workers Health and Quality of Life. 2. Compliance with MSHA.
INSTALLATION & COMMISSIONING. 5WSS Installation Hanging the Unit Hanging the Unit Location Considerations Location Considerations Refrigerant Piping Refrigerant.
Flat Saw Training. Flat Saw Sizes –Low Horsepower Blade diameters range from 8” (200mm) to 18” (450mm) Power ranges from 4 to 25 horsepower.
Presented at: Kingsley’s Woolloomooloo Presented by: Ben Pearson & Dan Butt Date: 8 August 2011 Energy Efficiency for Commercial Kitchens.
Click to Enter. Circuit 1Circuit 2Circuit 3 Circuit 4Circuit 5.
SIP POU cooler Installation Guide. Getting Started The SIP 2000 can be easily installed in most POU coolers in just a few minutes. The tools needed are.
Natura Water Machine B and D Series 3 – Dispense tower plumbing kit Kit number Kit includes components used for both Natura B and Natura D series.
Discover the Dosmatic Difference Trouble Shooting your Dosmatic injector for years of service.
Elite Marine Yachts. Marine Boat Refrigeration Products Leading supplier of marine refrigerators and freezers Dometic Marine presents enhanced lines of.
Warehouse Safety Is This You????.
Coffee Dispenser Specifications and Installation Requirements.
VIEW SERIES with Sliding Door
Temperature Test Allows monitoring of temperature changes.
Quick Reference Parts Guide Introduction
"This document can not be used without Samsung's authorization"
The GranView Fireplace
Installation Walkthrough Image Guide
STEP 1: ASSEMBLE ANGLE PLATES
How To Call Phones From Gmail Go to the chat on left side of the Gmail screen.
Air Distribution Control
STEP 1: ASSEMBLE ANGLE PLATES
Student CD for Commercial Refrigeration for A/C Technicians Chapter 12 Ice Machines.
ICE 101 APPLICATION GUIDE INTALLATION AND OPERATIONAL CONSIDERATIONS.
Preventative Maintenance & Service
Christmas Card Box Marcus P. Dula.
Quick start guide MS110 SHIPPING/Set Up/ Operation REQUIREMENTS
Presentation transcript:

Horizon Icemaker for Vision Satellite-fill Installation Installation Best Practices To navigate through the presentation, press the → and ← keys on your keyboard or click the forward and backward buttons in the lower left corner of your screen.

Vision™ Dispenser Height Clearances 60” for installation 49” for service after installation 51” for installation 36” for service after installation VU155 Minimum Height Clearance VU300 Minimum Height Clearance

Vision™ and Horizon™ Clearances 12” either side required for service The Horizon™ Icemaker must be installed a minimum of 12 inches from the Vision™ Dispenser. You will read more later about the importance of under-counter clearances and their effect on air circulation.

The dispenser’s lip (deck plate) will not support the weight of the machine. Failure to install the supplied legs will cause the lower bin portion to separate from the upper beverage rail, resulting in damage to the dispenser. Vision™ In-Counter Installation

23.5” The docking station should be securely mounted onto the cabinet base. The docking station makes sure the icemaker fits properly through the access door or panel for under-counter installations. Please confirm that you have a minimum cabinet opening height of 23.5” inches. Docking Station Installation

The icemaker draws air through the intake grille to keep the condenser cool during operation. Follett supplies an air-intake grille that must be installed into the access door or panel to provide the icemaker with unrestricted air flow. Intake Grille Installation

Custom Intake Grille Dimensions 1000 series 150 square inches (12” x 16”) 1400 series 175 square inches (16” x 16”)

Intake and Exhaust Clearance 18” If you install the exhaust grille in the front of the counter, you must maintain at least 18 inches between the exhaust and intake openings to prevent hot air from recirculating. If the intake and exhaust are less than 18 inches apart, the intake will recirculate hot exhaust air back into the icemaker. The hot air will cause the icemaker to overheat and produce poor quality ice. The ice maker could shut down due to high head pressure.

When the icemaker cycles off, ice left in the transport tube will slowly melt. For proper dispense operation, this melt water must drain back into the icemaker. Before you measure and cut the transport tubing to length, ensure the following specifications: The transport tube must slope back towards the icemaker for proper drainage. Slope tubing at least a 1/4- inch per foot pitch. The transport tube must be secured every 2 feet to prevent dips and traps from forming Insulate the entire length of the ice transport tube between the dispenser and the icemaker. Transport Tube Installation

Rubber Gasket Installation Rubber gasket Included in the box with the louvered grilles is a rubber gasket that must be installed completely around the intake opening on the front cover, as shown in the photo. This gasket provides a seal between the ice machine and the cabinet door to prevent hot air recirculation

For more information… Consult your service manual …go Visit Follett’s website …go Attend online training …go Contact Technical Service …go