Status of high pressure RF cavity project K. Yonehara Accelerator Physics Center, Fermilab 10/08/20101MAP Friday meeting.

Slides:



Advertisements
Similar presentations
High pressure RF cavity project Katsuya Yonehara APC, Fermilab 2/28/11 - 3/4/111.
Advertisements

Erdem Oz* USC E-164X,E167 Collaboration Plasma Dark Current in Self-Ionized Plasma Wake Field Accelerators
Beam Test of a High-Pressure GH 2 -Filled RF Cavity (for efficient muon beam cooling for a MC or NF, since the low-Z ionization energy-loss absorber and.
Progress of the sub-harmonic bunching system (i.e. upgrading progress of BEPCII present bunching system) Pei Shilun for the SHBS team Accelerator center,
(HP)RF Instrumentation Moses Chung APC, Fermilab MuCool RF Workshop III
Progress of High Pressure Hydrogen Gas Filled RF Cavity Test Katsuya Yonehara Accelerator Physics Center, Fermilab MTA RF workshop Fermilab, November 15-16,
1 More on gas filled rf cavities Alvin Tollestrup RF One Day Workshop Oct 15, 2008.
Frictional Cooling MC Collaboration Meeting June 11-12/2003 Raphael Galea.
2/7/2002 RolMUCOOL/MICE1 20b. Gaseous Energy Absorber, 21a. High Pressure RF Cavities New Money for New Approaches DOE Small Business Innovation Research.
July 28, 2004K. Yonehara, NuFact'04 Osaka1 High pressure RF cavities for muon beam cooling Katsuya Yonehara Illinois Institute of Technology NuFact04 in.
Controls Review  Want to record a full configuration of the experiment at every possible “event”, including controls data.  Event trigger = accelerator.
Rol - July 21, 2009 NuFact09 1 Muon Cooling for a Neutrino Factory Rolland P. Johnson Muons, Inc. ( More.
Physics of fusion power Lecture 10 : Running a discharge / diagnostics.
-Factory Front End Phase Rotation Optimization David Neuffer Fermilab Muons, Inc.
Design and test of a high-speed beam monitor for hardon therapy H. Pernegger on behalf of Erich Griesmayer Fachhochschule Wr. Neustadt/Fotec Austria (H.
MuCool RF Status MICE Collaboration Meeting June 7-10, 2006, Fermilab A. Moretti June 9, 2006.
Helical Cooling Channel Simulation with ICOOL and G4BL K. Yonehara Muon collider meeting, Miami Dec. 13, 2004 Slide 1.
RF background, analysis of MTA data & implications for MICE Rikard Sandström, Geneva University MICE Collaboration Meeting – Analysis session, October.
17 March 2005Edda Gschwendtner1 MICE Cooling Channel: Can we predict cooling to ? Edda Gschwendtner Challenge Systematics Cooling Channel Beam Line.
Mahzad - 8/9/2007 AAC Presentation 1 High Pressure RF Studies Mahzad BastaniNejad Muons, Inc., Old Dominion University Muons, Inc.
Hydrogen Recombination Time (µs) RF Envelope (V) Here So We get Calculated from # of protons per bunch Calculated from energy loss (voltage drop) in the.
201 MHz and 805 MHz Cavity Developments in MUCOOL Derun Li Center for Beam Physics Lawrence Berkeley National Laboratory Nufact 2002 Workshop, London,
Emittance measurement: ID muons with time-of-flight Measure x,y and t at TOF0, TOF1 Use momentum-dependent transfer matrices iteratively to determine trace.
Institutional Logo Here Harold G. Kirk DOE Review of MAP (FNAL August 29-31, 2012)1 The Front End Harold Kirk Brookhaven National Lab August 30, 2012.
Emittance measurement: ID muons with time-of-flight Measure x,y and t at TOF0, TOF1 Use momentum-dependent transfer matrices to map  path Assume straight.
High Current Electron Source for Cooling Jefferson Lab Internal MEIC Accelerator Design Review January 17, 2014 Riad Suleiman.
Tunable, resonant heterodyne interferometer for neutral hydrogen measurements in tokamak plasmas * J.J. Moschella, R.C. Hazelton, M.D. Keitz, and C.C.
UKNF OsC RAL – 31 st January 2011 UKNF - Status, high lights, plans J. Pozimski.
Diagnostics for intense e-cooled ion beams by Vsevolod Kamerdzhiev Forschungszentrum Jülich, IKP, COSY ICFA-HB2004, Bensheim, October 19, 2004.
Nonlinear Optics in Plasmas. What is relativistic self-guiding? Ponderomotive self-channeling resulting from expulsion of electrons on axis Relativistic.
Ionization Detectors Basic operation
Compton Experiment at ATF Tohru Takahashi Hiroshima University for Collaborators (particularly Omori san for slides)
-Factory Front End Phase Rotation Gas-filled rf David Neuffer Fermilab Muons, Inc.
Report of High Pressurizing gaseous Hydrogen filled RF cavity experiment K. Yonehara on behalf of HPRF working group APC, Fermilab 1/13/101 NFMCC meeting.
MICE at STFC-RAL The International Muon Ionization Cooling Experiment -- Design, engineer and build a section of cooling channel capable of giving the.
Calculation of Beam loss on foil septa C. Pai Brookhaven National Laboratory Collider-Accelerator Department
MCTF Andreas Jansson MUTAC Meeting 8-10 April MCTF EXPERIMENTAL ACTIVITES - towards demonstrating 6D cooling.
Controls for Particle ID/tracking in MICE 1.Physics and systematics 2.Controls types 3.Controls list 4.Needed for particle ID/tracking M. A. Cummings May.
RF studies at Fermilab MuCool Test Area Fermilab MuCool Test Area MuCool Test Area (MTA) at Fermilab is a dedicated facility at the end of the LINAC built.
Recent progress of RF cavity study at Mucool Test Area Katsuya Yonehara APC, Fermilab 1.
A. Bross MICE CM17 February MuCool RF Program 805 and 201 MHz Studies.
Institutional Logo Here July 11, 2012 Muon Accelerator Program Advisory Committee Review (FNAL July 11-13, 2012)1 The Front End.
RF background, update on analysis Rikard Sandström, Geneva University MICE Analysis phone conference, October 30, 2007.
Frictional Cooling A.Caldwell MPI f. Physik, Munich FNAL
Beam Interaction with gas filled RF Cavities Alvin Tollestrup BNL Workshop.
Villars, 26 September Extra Low Energy Antiproton Ring (ELENA) for antiproton deceleration after the AD Pavel Belochitskii for the AD team On behalf.
Progress of Bunched Beam Electron Cooling Demo L.J.Mao (IMP), H.Zhang (Jlab) On behalf of colleagues from Jlab, BINP and IMP.
Progress of gas-filled RF hadron monitor study K. Yonehara APC, Fermilab 2/10/16K. Yonehara1.
TRIUMF laboratory studies Christopher Hearty University of British Columbia/IPP 27-Sep-2010.
Study of Dielectric Loaded RF Cavity MAP MEETING - S EPTEMBER 23, 2011J ESSICA C ENNI.
Basic of muon ionization cooling K. Yonehara 8/29/11HPRF cavity physics seminar - I, K. Yonehara1.
Progress of high pressure hydrogen gas filled RF cavity K. Yonehara APC, Fermilab 11/02/111 Joint MAP & High Gradient RF Workshop, K. Yonehara.
Progress on high pressure gas filled RF cavity test program K. Yonehara & A. Tollestrup APC, Fermilab 3/4/121MAP collaboration meeting 2012.
Katsuya Yonehara Accelerator Physics Center, Fermilab On behalf of the Muon Accelerator Program 5/22/121International Particle Accelerator Conference,
Milorad Popovic On behalf of helical cooling channel design group (Katsuya Yonehara) Accelerator Physics Center, Fermilab 8/10/13NuFact 13, M. Popovic1.
Measurement of 400 MeV Proton Beam Intensity and Transmission Through Collimator of HPRF Cavity at Fermilab MuCool Test Area M. R. Jana 1, M. Chung 1,
Estimate store energy and power dissipation in a simple DL pillbox cell K. Yonehara APC, Fermilab 11/5/14HPRF/RF breakdown meeting, K. Yonehara1.
Progress of High Pressure Hydrogen Gas Filled RF Cavity Test Katsuya Yonehara Accelerator Physics Center, Fermilab Muon Accelerator Program Review Fermilab,
August 8, 2007 AAC'07 K. Yonehara 1 Cooling simulations for Muon Collider and 6DMANX Katsuya Yonehara Fermilab APC MCTF.
Muons, Inc. Feb Yonehara-AAC AAC Meeting Design of the MANX experiment Katsuya Yonehara Fermilab APC February 4, 2009.
1 Yagmur Torun, IIT Katsuya Yonehara, Fermilab Dec 16, 2010 – MAP PMG Meeting.
Research and development toward a future Muon Collider Katsuya Yonehara Accelerator Physics Center, Fermilab On behalf of Muon Accelerator Program Draft.
Spectroscopic Analysis of DC and RF Breakdowns
MuCool Test Area Dedicated facility built at the end of the Linac to address MuCool needs RF power 805MHz, 201MHz)
MICE RF Cavity Simulations and Multipactor
PIN DIODE.
Design of the MANX experiment
Damping Ring Kicker Tests at AØ
Physics Processes Missing from our Current Simulation Tools
A little physics about breakdown in HPRF cavities
Presentation transcript:

Status of high pressure RF cavity project K. Yonehara Accelerator Physics Center, Fermilab 10/08/20101MAP Friday meeting

805 MHz High Pressure RF cavity in B field Maximum electric field in HPRF cavity Schematic view of HPRF cavity High Pressure RF (HPRF) cavity has been successfully operated in strong magnetic fields Metallic breakdown Gas breakdown: Linear dependence Governed by electron mean free path Metallic breakdown: Plateau Depend on electrode material No detail study have been made yet Gas breakdown Operation range in cooling channel (10 to 30 MV/m) P. Hanlet et al., Proceedings of EPAC’06, TUPCH147 10/08/20102MAP Friday meeting, K. Yonehara

Apply HPRF cavity in front end channel Dense hydrogen gas can be used as an ideal buffer to suppress breakdown and also be used as an ionization cooling absorber GH2 cools down RF windows Schematic drawing of HPRF cavity in frontend pre- cooler channel Simulation of muon emittance in hybrid front end channel Hybrid: LiH (various widths (6~10 mm) in simulation) + 10 atm GH 2 Be pressure safety window is included J.C. Gallardo & M.S. Zisman et al., Proceedings of IPAC’10, WEPE074 Results are comparable with vacuum front end channel 10/08/20103MAP Friday meeting, K. Yonehara One example:

Breakdown probability in HPRF cavity Breakdown probability around boundary The data was systematically taken with copper electrodes K. Yonehara et al., Proceedings of IPAC’10, WEPE069. Operation gradient in cooling channel 10 to 30 MV/m E/p=14 E/p=10 E/p=7 old result E/p is a key parameter in DC breakdown model 10/08/20104MAP Friday meeting, K. Yonehara E/p is also a key parameter in RF breakdown!! It seems that gas breakdown mechanism is independent on RF frequency

Simulate beam loading effect in HPRF cavity with the MTA proton beam M. Chung et al., Proceedings of IPAC’10, WEPE067 Beam loading effect: Beam-induced ionized-electrons are produced and accumulated They are shaken by RF field and consume large amount of RF power A loading effect was estimated as a function of beam intensity Assumptions: - Only ionization electrons (~1000 e/p/cc) are taken into account - Recombination rate is cm 3 /s - Ignore thermal diffusion - Ignore dynamics of heavy ions 10/08/20105MAP Friday meeting, K. Yonehara

Criticism in HPRF cavity for down selection RF field must be recovered in few nano seconds 1. DC to 800 MHz, Hydrogen breaks down at E/P = 14. It indicates we can use DC data as a framework to explain results. Need to verify frequency independence by testing different frequency HP cavity 2. Electrons move with a velocity,. Current. Power dissipation due to electrons in phase with RF and dissipate energy through inelastic collisions = Measurements with beam verify mobility numbers and verify our loss calculation 3. Electrons recombine with positive ions and removed. If this is very fast they don’t load cavity, if slow cause trouble Beam measurement will give the recombination rate 4. Solution: use electronegative gas(es) to capture electrons and form negative ions Beam measurement will verify attachment rate 5. A+e →A - heavy negative ions. How long do these hang around and do they cause the breakdown voltage of the cavity to be lowered Beam measurement will give necessary answers Feasibility, including a hydrogen safety analysis, also must be assessed 10/08/20106MAP Friday meeting, K. Yonehara

MTA beam line 10/08/2010 MAP Friday meeting, K. Yonehara7 MTA experimental hall MTA solenoid magnet Final beam absorber 400 MeV H - beam Beam profile: Deliver 400 MeV H - beam in the MTA exp. hall to H - /pulse Tune beam intensity by collimator and triplet (reduce factor 1/10) MTA exp hall 400 MeV H - beam

Apparatus for beam test 10/08/2010MAP Friday meeting, K. Yonehara8 400 MeV H - beam Elastic scattered proton from vacuum window No energized device within 15 feet from HP cavity due to hydrogen safety issue Beam must be stopped in the magnet due to radiation safety Beam signal: There are two toroid coils on the beam line One will measure the primary beam intensity and other will pickup current after collimator One telescope beam counter for DAQ trigger signal CCD + Luminescence screen Polaroid film after cavity (Ti)

Diagnostic system for beam test Two RF pickup probes – E/B sense antennas Two F/R RF power directional couplers Six optical ports – Light intensity monitor – spectrometer – TPB (wavelength shifter) Two toroid coils – Monitor current before/after collimator One beam counter CCD + Viewer RF circulator + Damper – Remove RF reflected power 10/08/2010MAP Friday meeting, K. Yonehara9

Variables in beam test Beam intensity – 10 7 protons/bunch as default – 10 7, 10 8, 10 9 protons/bunch – Beam pulse length 5 to 20  s GH2 pressure – 800 psi as default – 400, 800, 1400 psi RF amplitude – 15 MV/m as default – 0, 5, 15, 30 MV/m, on Paschen E Gas species (option) – N2, He Dopant gas effect – SF6 (0.1 %) as default – SF6 (0.01, 0.1 %), – N2 9/22/1010HPRF Wednesday meeting

Time table of HPRF test SepOctNov RF modification, assemble & calibration Wave Guide & Circulator Beam line Detector & DAQ Timing Calibration RF test without beam RF beam test 9/29/1011 Total run duration will be 2.5 months 10/11/10 ~10/22/10 Interruption due to modification of Cryo transfer line & installation of RF switch HPRF Wednesday meeting When do we really start? Rad Shielding Assessment is the first requirement. Button test may go first if the assessment is delayed.

RF breakdown signal analysis 10/08/2010MAP Friday meeting, K. Yonehara12 RF pickup signal in breakdown process Electron density from RF pickup signal analysis A. Tollestrup et al., FERMILAB-TM-2430-APC, K. Yonehara et al., Proceedings of IPAC’10, WEPE069 Equivalent resonance circuit Resonance circuit of normal RF cavity consists of L and C Breakdown makes streamer It produces additional L and R Resonance frequency is shifted by them Current can be estimated from L, R and drift velocity of electrons in hydrogen plasma Probe seems to be sensitivity ~10 13 electrons Lessons in breakdown study

Spectroscopy in breakdown 10/08/2010MAP Friday meeting, K. Yonehara13 Spectroscopy in the high pressure RF cavity Spectroscopy at Balmer line K. Yonehara et al., Proceedings of IPAC’10, WEPE069 Thermal radiation model: Broken line is a least square fitting of thermal radiation formula by taking into account red points which is on neither any hydrogen nor copper resonance lines “0 ns” is a peak light intensity Plasma temperature is raised up to 18,000 K in 5 ns and down to 10,000 K in 50 ns Deexitation emission: Solid line is a least square fitting of Lorentz function by taking into account all points Timing delay due to lifetime of de-excitation Broadened Balmer line (τ ~ 16 ns) is observed Stark effect well-explains resonance broadening Plasma density ~10 19 electrons/cm 3 Using fast data acquisition system Lessons in breakdown study

Precise timing calibration 10/08/2010MAP Friday meeting, K. Yonehara14 RF pickup signal Spectroscopic light Signal delay RF breakdown event

Study delay and distortion of signal in cable 10/08/2010MAP Friday meeting, K. Yonehara15 Giulia Collura (Summer student) made a fast laser circuit by using avalanche trangister Realize 0.6 ns timing resolution system Laser diode was located in parallel to R3 Similar test is planed by using < 100 ps Laser system Initial RF pickup signal Final signal after 300 ft ½’’ Heliax cable She also investigated the distortion of signal in cable No big signal distortion is observed Phase shift due to dispersion was observed

Hydrogen plasma model in breakdown (I) 10/08/2010MAP Friday meeting, K. Yonehara16 We are still working on the fine timing calibration. We do not know when the plasma light is emitted in the RF signal timing yet. But, we have already seen several remarkable phenomena in RF signal and spectroscopic light. The evidences are: We see the RF modulation from -74 ns, i.e. RF amplitude gets lower but no frequency shifts up to -67 ns. From the resonance circuit analysis, electrons are in the plasma and grows exponentially by next 7ns. It is clearly seen the frequency shift at -67 ns. On the other hand, the plasma temperature is extracted from thermal radiation model, where 0 ns corresponds to the maximum light intensity. It seems that the RF frequency modulation happens at the highest plasma temperature

Hydrogen plasma model in breakdown (II) 10/08/2010MAP Friday meeting, K. Yonehara17 On the other hand, we have observed the broadening of resonance line after 0 ns. This suggests that the plasma density suddenly grows after frequency modulation happens. Something takes place at t=-67 ns! Alvin’s model: The electron swarm touches down on the electrode and extremely high current flows between two electrodes. It makes a plasma pinch due to self inductance. Plasma lens! What we have learned from the breakdown analysis: The number of plasma seeding electrons is ~ It grows exponentially up to ~10 15 in 5~10 ns On the other hand, the electron density in breakdown plasma grows up to Assume that the plasma shape is cylinder then the radius of plasma is ~100 μm Plasma temperature grows up to 18,000 K (ave. Ke = 2.3 eV)

Hydrogen plasma model in breakdown (III) 10/08/2010MAP Friday meeting, K. Yonehara18 More thoughts: Initial electron kinetic energy seems not to be enough to initiate cascade process although some electron is accelerated and warm up the plasma temperature I guess that the main driver of initial plasma growth is surface emission electrons Electron is emitted from surface and decelerated immediately by hydrogen gas It stays in the cavity for a while since there is no dominant absorption process in the cavity (cross section of dissociative absorption of H2 is to cm 2 ) Once the density reaches the critical value, the plasma pinch takes place and change the resonant frequency RF power cannot go into the cavity due to mismatching while the plasma disappears due to thermal diffusion (τ ~ 1 μs) Breakdown plasma is too dense by comparing with beam-induced plasma Breakdown plasma has too many electrons to investigate recombination process

Recombination process in pure GH2 10/08/2010MAP Friday meeting, K. Yonehara19 A.Tollestrup et al., FERMILAB-TM-2430-APC Polyatomic hydrogen cluster: H n + are formed from H 2 + and H + in very short time Recombination of H n + is < 1 μs that has been observed in dilute condition No measurement has been done in dense hydrogen environment Careful RF Q reduction measurement with beam (as shown in previous slide) will indicate recombination rate with polyatomic hydrogen cluster Key physics

Electronegative dopant gas 10/08/2010MAP Friday meeting, K. Yonehara20 SF6 and other Fluorine base gas has a large attachment cross section However, SF6 is dissociated and forms F - that damages the cavity surface Besides, cavity cannot operate in cryogenic temperature lower than the boiling point of SF6 (209 K in STP) NH3 has 1/1000 lower attachment cross section than SF6 but it forms in H2 + N2 mixture gas due to beam energy deposition Question is how much amount of N2 need Damaged Cu electrode Key physics

High Pressure pillbox cavity 10/08/2010MAP Friday meeting, K. Yonehara21 Muons, Inc. built a new cavity: Confirm B field independence in realistic RF field condition Operate cavity in vacuum to high pressure gas condition Test from room temperature down to LN2 temperature Test various window materials; Be is the most interesting material Test RF grid window

Summary HPRF cavity can operate in B field (3 T) without any field degradation We understand large part of gas breakdown physics and realize it is not a good model to investigate the beam loading effect Beam loading effect must be measured by using intense beam as the next feasibility study Preparation for beam test is on going – Waiting for radiation shielding assessment to begin the second stage including with beam test 10/08/2010MAP Friday meeting, K. Yonehara22