SAMURAI Si Detector M. Kurokawa a), H. Baba a), T. Gunji b), H. Hamagaki b), S. Hayashi b),T. Motobayashi a), H. Murakami a), A. Taketani a), M. Tanaka.

Slides:



Advertisements
Similar presentations
Status of test beam data analysis … with emphasis on resistive coating studies Progress and questions 1Meeting at CEA Saclay, 25 Jan 2010Jörg Wotschack,
Advertisements

Sci-Fi tracker for IT replacement 1 Lausanne 9. December 2010.
E. Atkin, E. Malankin, V. Shumikhin NRNU MEPhI, Moscow 1.
東京大学におけるMSGCの開発 東京大学 二河久子 藤田薫、高田夕佳、高橋浩之 2007/01/27 佐賀大学.
Front-end electronics for Time Projection Chamber I.Konorov Outlook:  TPC requirements  TPC readout options  Options for TPC FE chips  Prototype TPC.
N-XYTER Hybrid Developments Christian J. Schmidt et al., GSI Darmstadt JINR, Dubna, Oct. 15 th 2008.
  Florence, June 28 th 2007 – RD07   – 
PHENIX Vertex Tracker Atsushi Taketani for PHENIX collaboration RIKEN Nishina Center RIKEN Brookhaven Research Center 1.Over view of Vertex detector 2.Physics.
Ionization. Measuring Ions A beam of charged particles will ionize gas. –Particle energy E –Chamber area A An applied field will cause ions and electrons.
Progress towards a Long Shaping-Time Readout for Silicon Strips Bruce Schumm SCIPP & UC Santa Cruz SLAC LCWS05 July 28-31, 2004.
RAD – The Radiation Assessment Detector for MSL Stephan Böttcher, CAU Kiel MSL/RAD Critical Design Review 7b – RAD Sensor Head Stephan Böttcher
Science Specification Table 12 keV keV for neutral particles 40.5 cm 2 image plane Electronic Noise 3 keV FWHM Proton Dead Layer
The LHCb Inner Tracker LHCb: is a single-arm forward spectrometer dedicated to B-physics acceptance: (250)mrad: The Outer Tracker: covers the large.
Silicon Stripixel Detector Junji Tojo RIKEN Vertex2005 Lake Chuzenji, Nikko, Japan November 7-11, 2005.
Performance test of STS demonstrators Anton Lymanets 15 th CBM collaboration meeting, April 12 th, 2010.
Peter, Wieczorek - EE Low Noise Charge Sensitive Preamplifier Development for the PANDA Calorimeter Design and Measurements of the APFEL - Chip.
The ALICE Forward Multiplicity Detector Kristján Gulbrandsen Niels Bohr Institute for the ALICE Collaboration.
Development of the Readout ASIC for Muon Chambers E. Atkin, I. Bulbalkov, A. Voronin, V. Ivanov, P. Ivanov, E. Malankin, D. Normanov, V. Samsonov, V. Shumikhin,
Valerio Re, Massimo Manghisoni Università di Bergamo and INFN, Pavia, Italy Jim Hoff, Abderrezak Mekkaoui, Raymond Yarema Fermi National Accelerator Laboratory.
JRA-1 ISRSI Consortium Meeting Perugia, INAF/IASF (BO,PA)
7/28/2003DC/EC Review Aerogel Read out Electronics K. Ozawa, N. Kurihara, M. Inaba, H. Masui T. Sakaguchi, T. Matsumoto.
L.Royer– Calice LLR – Feb Laurent Royer, J. Bonnard, S. Manen, P. Gay LPC Clermont-Ferrand R&D pole MicRhAu dedicated to High.
Solid State Detectors for Upgraded PHENIX Detector at RHIC.
The development of the readout ASIC for the pair-monitor with SOI technology ~irradiation test~ Yutaro Sato Tohoku Univ. 29 th Mar  Introduction.
The DAMPE STK G. Ambrosi INFN Perugia. The DAMPE Detector Mass: 1480 Kg Power: 600 W Data: 16 Gbyte/day Liftime: 5 years 2.
NA62 straw readout Characterization and qualification of the frontend electronics Detector and interface to frontend Small readout system Plans Expected.
WG3 – STRIP R&D ITS - COMSATS P. Riedler, G. Contin, A. Rivetti – WG3 conveners.
Click to edit Master subtitle style Presented By Mythreyi Nethi HINP16C.
1 19 th January 2009 M. Mager - L. Musa Charge Readout Chip Development & System Level Considerations.
D. Attié, P. Colas, E. Delagnes, M. Riallot M. Dixit, J.-P. Martin, S. Bhattacharya, S. Mukhopadhyay Linear Collider Power Distribution & Pulsing Workshop.
CBM 12 th Meeting, October 14-18, 2008, Dubna Present status of the first version of NIHAM TRD-FEE analogic CHIP Vasile Catanescu and Mihai Petrovici NIHAM.
Jan. 25, 2011 Status of the Aerogel RICH Readout Trig/DAQ Meeting in Beijing 1 S. Nishida (KEK) S. Nishida Status of the Aerogel RICH Readout Belle II.
ダイナミックレンジの大きな 電荷有感型前置増幅器の開発 M. Kurokawa a), H. Baba a), T. Gunji b), H. Hamagaki b), S. Hayashi b),T. Motobayashi a), H. Murakami a), A. Taketani a), M.
Front-end Electronic for the CALICE ECAL Physic Prototype Christophe de La Taille Julien Fleury Gisèle Martin-Chassard Front-end Electronic for the CALICE.
Flex Cable Readout unit Si Sensor 256 analog lines Interconnect board NCC signal packaging concept PA board -This is the calorimeter – all pads in the.
MICRO-STRIP METAL DETECTOR FOR BEAM DIAGNOSTICS PRINCIPLE OF OPERATION Passing through metal strips a beam of charged particles or synchrotron radiation.
A Forward Calorimeter (FoCal) as upgrade for the ALICE experiment at CERN S. Muhuri a, M. Reicher b and T. Tsuji c a Variable Energy Cyclotron Centre,
Analog Circuits Hiroyuki Murakami. CONTENTS Structure of analog circuits Development of wide linear range CSA system Problem of analog circuits How to.
Status of hardware activity in CNS Taku Gunji Center for Nuclear Study University of Tokyo 1.
The design of fast analog channels for the readout of strip detectors in the inner layers of the SuperB SVT 1 INFN Sezione di Pavia I Pavia, Italy.
GEM Integrated PCB readout and cooling
Si Sensors for Additional Tracker
Budker INP V.Aulchenko1,2, L.Shekhtman1,2, V.Zhulanov1,2
n-XYTER Hybrid Developments
Beam detectors performance during the Au+Au runs in HADES
A General Purpose Charge Readout Chip for TPC Applications
(g, n) (g, p) experiment at SAMURAI
Wide Dynamic range readout preamplifier for Silicon Strip Sensor
Activity report of FoCAL from CNS
Christoph Schwanda (HEPHY Vienna) For the Belle II SVD group
INFN Pavia and University of Bergamo
A Forward Calorimeter (FoCal) as upgrade for the ALICE experiment at CERN S. Muhuria , M. Reicherb and T. Tsujic a Variable Energy Cyclotron Centre,
Application of VATAGP7 ASICs in the Silicon detectors for the central tracker (forward part) S. Khabarov, A. Makankin, N. Zamiatin, ,
Silicon Pixel Detector for the PHENIX experiment at the BNL RHIC
Electronics for the E-CAL physics prototype
Production and test of the LHCf microstrip silicon system
A Low Power Readout ASIC for Time Projection Chambers in 65nm CMOS
Status of n-XYTER read-out chain at GSI
SAMURAI Si detector Requirements overview
SiD Electronic Concepts
Yasuhiro Sugimoto KEK 17 R&D status of FPCCD VTX Yasuhiro Sugimoto KEK 17
SiD Tracker Concepts M. Breidenbach
Naohito Iwasa Dept. Phys., Tohoku Univ.
Pre-installation Tests of the LHCb Muon Chambers
Signal processing for High Granularity Calorimeter
Readout Electronics for Pixel Sensors
CBM-MUCH-RPC Electronics
Readout Electronics for Pixel Sensors
Coincidence measurement of heavy ion and protons with SAMURAI
Readout Electronics for Pixel Sensors
Presentation transcript:

SAMURAI Si Detector M. Kurokawa a), H. Baba a), T. Gunji b), H. Hamagaki b), S. Hayashi b),T. Motobayashi a), H. Murakami a), A. Taketani a), M. Tanaka c), Y. Togano a), K. Yoneda a) a) RIKEN, Nishina Center b) CNS, the Univ. of Tokyo c) KEK

Requirements for SAMURAI Si detector system Coulomb breakup exp. proton heavy particle (z < 50) I.Effective area ~ 9 cm × 9cm II.Position resolution ~ 1 mm III.Dynamic range of the electronics ~ 10^4 coincident measurement from proton (z = 1) to heavy ions (z ~ 50)  2500 Pileup of beam events proton rich particle up to Sn Definition of dynamic range upper limit / lower limit (= 4  ) of detection

Specification of a Si detector 6 in. --> 325  m single-sided strip detector developed for GLAST satellite is employed signals from 3 strips are grouped together on the PCB  readout pitch = 228  m × 3 = 684  m number of signal channels / detector = 384 / 3 = 128 ch. total number of signal channels = 128 × 5 = 640 ch. Ref.) T. Ohsugi et al., “Design and properties of the GLAST flight silicon micro-strip sensors”, Nucl. Instr. and Methods, A541 (2005)

Si 89.5 mm × 89.5mm C1 R C1 PCB design and bonding pattern for Si detector stip1 Stip2 Stip3 :::::: stip384 stip383 Symmetric layout with upper side Connectors made by KEL (USL0040L) for ultrafine coaxial cable 0.4 mm pitch Outer dimensions = 130 mm × 130 mm Capacitors to suppress cross talk through rear side < 1 / 10^4 = 0.01% enlarged view Will be ready in May

Specifications of the electronics 1)Electronics must have a wide dynamic range ~ 10^4 2)Electronics must be highly integrated circuit or really tiny discrete circuit Only conceptional idea exits at the moment Started development of a CSA (Charge Sensitive Preamplifier) with a dynamic range of 10^4 in ASIC (Application Specific Integrated Circuit ) less than 2 years ago Started development of a CSA (Charge Sensitive Preamplifier) with a dynamic range of 10^4 in ASIC (Application Specific Integrated Circuit ) less than 2 years ago For the subsequent stage of the CSA, such as S.A., HINP16C will be used.

pictures of HINP16C Drs. Yoneda, Baba and I visited U.S.A. for the negotiation last Nov. One PCB & one M.B. will be arrived in Feb. in RIKEN 16 ch/chip × 2 = 32 ch Mother Board with 16 slots 32 ch × 16 = 512 ch external preamp. Mode S.A.  Peak Hold  multiplexer C.F.D.  hit. pat. & multiplicity

Cooperative framework for the development of ASIC RIKEN KEK CNS, Univ. of Tokyo Collaborative research agreement was concluded on Aug. 1 st, 2010 development tool Experiences stuffs Need a CSA with a wide dynamic range for ALICE calorimeter consisting of W + Si Fund modification using FIB (focused ion beam) specialist of analog circuit: Murakami-san

Example of the modification using FIB Disconnection of traces passivating coating Insulation layer Metal (Al) layer enlarged and tilted view Limited area was irradiated with Ga beam RIKENDGCSP

Architectures of the present ASIC Cf = 1.8 pF Rf = 50 M  equivalent: Krummenacher feed back circuit is used ref.) F. Krummenacher, Nucl. Instru. Meth., A305 (1991) 527. Power consumption 10 mW/ch I.Capacitive division II.Openloop gain III.Saturation suppression

Architecture I: dual channel system CSA Qin Ch Cl Log Q in Log V out 4 pC40 pC H L similar response with single channel system

Output pulse shapes from the CSAs Ch Cl CSA  Chip and its test board TSMC 0.5  m process chip size ~ 1.6 mm × 1.2 mm

Result I: Dynamic range for a single channel CSA ADC-H ADC-L Definition of lower limit = 4  4.4 fC corresponds to 100 keV. pulser CSA SA-HG SA-LG ADC-H ADC-L

Result II: Dynamic range for dual channel CSAs ADC-H-H ADC-H-L ADC-L-L Definition of lower limit = 4  56 pF 560 pF pulser CSA SA-HGADC-H-H SA-LG ADC-H-L ADC-L-L

Summary and time schedule First prototype of RIKENDGCSP (Riken Dual Gain Charge Sensitive Premplifier) is working well. Dynamic range can be extended as much as the gain ratio First prototype of RIKENDGCSP second prototype of RIKENDGCSP Test with HINP16C & RIKENDGCSP Test including Si detector Mass production of circuit and test first experiment Good news: HAMAMATSU has started production of double sided strip detector. Selection has increased. Good news: HAMAMATSU has started production of double sided strip detector. Selection has increased.