SAFE USE OF DIATHERMY RACHEAL AFOLABI, RN, RM, H. Dip. PERI-OPERATIVE NURSING, H.Dip. HEALTH SYSTEM MANAGEMENT.

Slides:



Advertisements
Similar presentations
High voltage testing of laparoscopic accessories
Advertisements

FHM TRAINING TOOLS This training presentation is part of FHM’s commitment to creating and keeping safe workplaces. Be sure to check out all the training.
Hazards Of Electricity
Effect of Electricity on Living Tissue
Electrical Safety.
Positioning the Periop Patient Source : Phippen, M.L. & Wells, M.P. (1995). Perioperative nursing handbook. (p ).
1 Full Body Harness (course #989). 2 Course Orientation Registration Smoking Area Restrooms Fire Escape Breaks Measurement Review & Critique.
Safe Laparoscopy Reducing Complications Jonathan Frappell FRCS.FRCOG.
Two-mode Safety and Battery System Service
Last revised March 19, 2015 Electrical Department – EQUAL CODE: EL304 Care, Use, and Maintenance of Rubber Insulating Gloves.
Surgical Diathermy Machine
Kenny Low Dec 2009 Urology registrar Thursday teaching
EE 4BD4 Lecture 25 Electrosurgery Biomedical Device Technology: Principles and Design, Charles C. Thomas Publisher 2007 Anthony K. Chan 1.
Electrocautery.
SAFETY TALK - SLIDE 1 OF 14 Elkhart Products Corporation 08/00 WELCOME ELKHART PRODUCTS CORPORATION “TOOLBOX SAFETY TALK” Welding, Cutting, & Burning.
Section 2 Safety, Tools and Equipment, Shop Practices Unit 4 General Safety Practices.
1 ENVIRONMENTAL ENERGY TECHNOLOGIES DIVISION JUNE 24, 2013 Hand Tool Safety.
Welding, Cutting, & Burning. GENERAL HAZARDS General hazards of welding include: –Impact –Penetration –Harmful dust –Smoke –Fumes –Heat –Light radiation.
Fiber Optic Light Source Safety. Fiber Optic cables Fiber optic cables and light sources are used with many types of rigid endoscopes (e.g., laparoscopes,
Proper Use of Extension Cords Proper Use and Electrical Hazard Awareness for Extension Cord Users Module 2.
1 LASER SAFETY NSC Clinical and Operational Conference Calls August 24, 2005.
Electrical Surgical Unit
Suture Materials ABSORBABLE: lose their tensile strength within 60 days. NON- ABSORBABLE:
Electrocardiography.
Circuit Protection Electrical circuits require protection to prevent fire or electrocution in the event of a fault. There are two main types of circuit.
Diathermy Interactions with Implanted Leads and Implanted Systems with Leads Marian Kroen Office of Surveillance and Biometrics Issues Management Staff.
Purpose Power lines Equipment Assured Grounding GFCI Conclusion.
What is a Watt? Everything you ever wanted to know about Electrosurgery. Fahad bamehriz, MD.
SITE SAFETY HAZARDS AND PROCEDURES. ELECTRICAL HAZARDS  Electricity is a serious workplace hazard.  Employees can be exposed to dangers such as : 
Diathermy.
Electricity at Work.
Electrical Safety.
 Safety  Job safety, is everyone’s business, and does not rest in the hands of some government body, nor solely with management or supervisors of the.
Without reference, identify principles about Electrosurgical Units with at least 70 percent accuracy.
Electrical Safety.
Do this now… Go to and complete the pre-lesson survey. Go to my eBoard and set up.
Electrical Safety in Construction. Objectives In this course, we will discuss the following: Common electrical hazards Standards relating to those hazards.
BASICS OF ELECTROSURGERY
Electrical Safety. Definitions v Exposed part v Live or energized part v De-energized part 1a.
Flammable and Combustible Liquids. Introduction !The two primary hazards associated with flammable and combustible liquids are explosion and fire !Safe.
Electrosurgery & Gyn Surgery: Get the Point Across
Chapter 7 Safety. Introduction This chapter covers the following topics: Dangers of electricity Preventive measures Electrostatic discharge Safety practices.
SAFETYSAFETY. Overview ●Introduction to Safety ●Potential Electronic Mishaps ●Safe Work Practices.
Proper Use of Extension Cords
Equipment Source- Alexander’s Care of the Patient in Surgery Patty Pavlikowski RN CST MA.
Electrical Stimulation Basic Setup and Patient Preparation Read and Follow the Manufacturer’s Recommendations.
Electro surg i cal unit  PURPOSE ESU are used for surgical cutting and for controlling bleeding by causing coagulation “ hemostasis ” at the surgical.
PORTABLE & TRANSPORTABLE ELECTRICAL EQUIPMENT. Legal Requirement and References Abu Dhabi RSB Electrical Regulations - makes reference to the need to.
This presentation may contain some forward looking statements, particularly regarding operational prospects in 2009 and beyond, which involve a number.
Shortwave Diathermy Clinical Application. Treatment Dosages Pulse DoseSensationWidthRate (pps) NTNo warmth65 µsec100 – 200 1Mild warmth100 µsec800 2Moderate.
RDT Hospital, Dept of Gen Surgery
TERMINAL OBJECTIVE OPERATE SELECTED OR EQUIPMENT IAW MANUFACTURER’S USER MANUAL.
Electrical Safety, Subpart K
Electrosurgical Unit.
Timing (minutes) Learning ObjectiveMain tasks / ProcessResources / tools 5TitleStandard Operating Procedures for Power Press Machine Slide 1 5Index 
Grounding & Bonding Hazardous Materials Certification Study Guide 2 Definition of Terms (continued) Static Electricity - Electricity present on a surface.
Flammable Liquids Directorate of Training and Education
Chapter 3 PHYSICAL INJURY AND CONTROLS 3.2 Electrical Safety
TOPIC: PATIENT SAFETY BASED ON SUCTION AND ELECTROSURGICAL DIATHERMY MACHINES. PRESENTER: ALCARD FIDELIS BIOMEDICAL TECHNOLOGIST. ENGINEERING DEPARTMENT.
Management of Surgical Smoke Tool Kit Part V: Additional Perioperative Nursing Care.
Electro surgical unit.
Physiologic signals Lecture (2).
Basics of Medical Equipment Lecture 6
Electrosurgical/Surgical Diathermy Units
A. In monopolar electrosurgery, current from an electrosurgical generator passes from an active electrode (the “Bovie” tip) through the patient to a return.
SURGICAL DIATHERMY.
SURGICAL DIATHERMY.
Diathermy and its safe use
Fundamental Use of Surgical Energy
Presentation transcript:

SAFE USE OF DIATHERMY RACHEAL AFOLABI, RN, RM, H. Dip. PERI-OPERATIVE NURSING, H.Dip. HEALTH SYSTEM MANAGEMENT

Diathermy is one of the most commonly used tool in the operating theatre

DEFINITION Diathermy is the generation of heat in body tissues by means of radiofrequency energy (passage of an electric current through the tissues). The energy is used to cut tissues, seal blood vessels and destroy unwanted cells by the deliberate application of intense heat.

Two basic patient circuits are used Monopolar Bipolar

MONOPOLAR During monopolar diathermy the patient forms part of the electrical circuit, only one side of the generator output is connected to the active electrode. The other side is connected to a large patient return plate. The plate provides a safe path for the current to pass back to the diathermy.

Completed Circuit 2. Electricity must complete the circuit, or it will not flow. The energy must be able to get back to "ground" (its place of origin). In this shot, the energy flows from the generator, to the patient via the electrosurgical pencil, through the patient, exits through the pad, and goes back to the generator.

BIPOLAR During bipolar diathermy the current flows between the tips of the forceps, one tip acting as an active electrode and the other as a return. The patient’s tissue acts as the conducting medium, through which the current will flow. One advantage with this type is that production of the cutting current is virtually impossible. The field of coagulation is limited to the contact area;

BIPOLAR (Cont.) the surrounding tissues are not damaged. There is no patient plate attached.

EFFECTS OF SURGICAL DIATHERMY CUTTING COAGULATION/DESICCATION FULGURATION

PATIENT PLATE/RETURN ELECTRODE A minimum conductive area of 10 sq inches is recommended. Plate must be kept in secure contact with the patient’s body surface.

SETTINGS ON ELECTRO-SURGICAL UNIT Blends setting Autocut Autocoag Users must ensure that they are familiar with all settings and their functions

TYPES OF PATIENT PLATES REUSABLE DISPOSABLE

DISPOSABLE PLATES CONDUCTIVE ADHESIVE PLATES Generally thin, lightweight & flexible Conductive adhesive which works like gel Continuous adhesive border

ROUTINE DAILY THEATRE CHECK This must include checking the electro-surgical unit to ensure that: - All cables & electrodes insulation are intact - Adequate supply of patient plates Functioning alarm systems Connections are all fitting securely Foot pedals are all present & working

THINK SAFETY!!!

POINTS TO REMEMBER IN PROPER PATIENT PLATE USE Ensure regular, planned preventative maintenance checks Any faulty equipment must be removed immediately Plates are single use Avoid placement near scars, implant sites or ECG electrodes A muscular well vascularised area is most suitable

POINTS (Cont.) Site must be clean, dry & shaved Protect skin integrity by ensuring pt is not resting on dispersive plate clamp The diathermy setting is determined by the surgeon Be familiar with normal power settings Do not allow fluid to pool at dispersive site Check pt contact & connection before commencing

POINTS (Cont.) Ensure pt is not in contact with any metal Place active electrode in a quiver when not in use Only aqueous fluids should be used for irrigation On completion of procedure, remove the plate carefully & inspect the skin Document use of diathermy in pt’s record

SUGGESTED SITES FOR PLATE PLACEMENT CALF UPPER ARM ABDOMEN MID BACK BUTTOCKS ANTERIOR & POSTERIOR THIGH

THINK SAFETY!!!

Pad Site Burn AORN Journal, March 1991 Why is this important? Here is an example of what can happen through the misuse of electrosurgery. This slide is of a four-year old little girl, who went in for a T&A procedure. She received a third-degree full thickness burn from an unmonitored pad. This was published in the March 1991 AORN journal. Understanding the basics of electrosurgery will allow you to prevent these types of incidents, not to mention the accompanying legal issues. AORN Journal, March 1991

HAZARDS OF ELECTRO-SURGERY ACCIDENTAL BURNS SURGICAL SMOKE MINIMAL ACCESS SURGERY ENDOSCOPIC SURGERY

CAUSES OF THERMOELECTRIC BURNS Poor patient plate contact Hair at the site of return electrode plate Break in the wire connecting the plate to the electro-surgical unit Detached return cable Ignition of flammable material on pt’s skin High voltage electrocution of the pt Abnormally high power setting

References 3M Health Care (2000) Safety in Surgical Diathermy 3M Health Care Ltd., England Wicker, P. (2000) Electrosurgery in perioperative practice. British Journal of Perioperative Nursing. Vol 10 (4).

Cont….. Electrosurgical Safety Guide, ConMed Corporation, USA.

THANK YOU FOR LISTENING