Welcome Growers Discover the Dosmatic Difference Installing your Dosmatic injector for years of service.

Slides:



Advertisements
Similar presentations
Leisure Vac Auto pool Cleaner. Trouble shooting Guide: Top Head Assembly Problem: Debris in the top head, causing cleaner to not work due to poor water.
Advertisements

MAO Flow Meters Sales Deck | Presentation Title What is the MAO Flow Meter? The MAO flow meter is an instrument used for monitoring or measuring.
Operation of the FW-720 Unit 1. Side 1 2 Inlet Hand Crank.
Circulating Water System
3.4.5 Student Book © 2004 Propane Education & Research CouncilPage Maintaining Bulk Plant Pumps, Strainers and Bypass Systems Knowing how to maintain.
 Established in 1995  Located in Wilmington, NC with a 40,000 Sqft facility.  Specializes in the design and manufacturing of connection solutions. 
HVAC523 Soldering.
Metering Pump Spare Parts Replacement. Pump Components (Metering Pump) Pumps are supplied with a 120VAC or 240VAC power cord. Use care to ensure pump.
Safety Gas Plus.
① The output signal of a room thermostat is ON or OFF according to changes of room temperature ② The power supply to a motorized valve is ON or OFF according.
Morgan City Rentals Diesel Jet Pump 6 x 6 Peerless Safe Operating Practices and Procedures.
STEAM TRAPS.
UL/FM Fire Pump Systems Lunch & Learn 04/18/05
© Blue Graphics Concept Sauer-Danfoss START-UP PROCEDURE PROPEL PUMP Instruction Sauer-Danfoss Belgium – T. Van Mossevelde.
Student Book © 2004 Propane Education & Research CouncilPage Installing Vapor Meters Vapor meters are precision measuring devices that.
Chemigation. Chemigation Chemigation is the process of applying pesticides and fertilizer through irrigation waterChemigation is the process of applying.
ZepZep C4 Entryway Foam System uctionInstruction Manual
Filling, purging and air removal
The DB In-Line Pumpout Unit Easy-to-use control panel with one switch to run the unit. 15 AMP reset fuse. 115 AC External water pump and tank drain have.
Boiler Mountings.
Suction Pumps.
Normal Operating Parameters Maintenance Schedule Common Problems Normal Operating Parameters Maintenance Schedule Common Problems ClearWater Tech, LLC.
Paint Circulation Technology Level 1 - Training Document
Dennis Sabre Fire Appliances
Welcome to the Ice-O-Matic® on-line training modules.
Unit 205: Cold water systems
Direct Cross-Connection (a) A Clean-In-Place system is used to direct sanitizer from a reservoir to a recently cleaned milk tank. The sanitizer exists.
Pump Installation Vigyan Ashram, Pabal.
Fuel Oil Systems Fuel Oil Systems consist of: Storage Tanks Pumps
STEAM HEATING.
Hydronic Mechanical Controls
3.4.2 Student Book © 2004 Propane Education & Research CouncilPage Types and Functions of Valves and Fittings Used in Bulk Plant Containers and.
Hydraulics For The Long Term
Fire Pump Functions The main function of a fire pump is to increase the pressure of the water that flows through it. Inadequate or nonexistent municipal.
Plan 2 – Dead-end Seal Chamber Optional Jacket
1 HVACR316 - Piping Soldering. 2 Soldering Copper Tubing The most common method of joining copper tubing in hydronic heating systems is soft soldering.
SETA Water treatment plant maintenance
Lesson Using Pneumatic Systems. Interest Approach Can you explain how air makes a pneumatic hand tool work?
Las Delicias Water Supply System OPERATION AND MAINTENANCE MANUAL 1.
Launch Chameleon Plus P - More Preventive features and safety L - More Longer Lasting and robust U - More User friendly operation S - More Service friendly.
Charging Cart Instruction & User Manual EnTrans Technology Co., Ltd.
Backflow Preventer Replacement Made Easy BY: Kenny Robbins.
Valves In Industry (Part 1)
Discover the Dosmatic Difference Trouble Shooting your Dosmatic injector for years of service.
Discover the Dosmatic Difference Maintaining your Dosmatic injector for years of service.
2 nd presentation by Patricia REVERSE OSOMOSIS :the possible solution for water hardness.
MixRite Water Driven Injectors Training
How Reverse Osmosis Water Purification Systems Work.
Vertical Pump Motor Manifold Upgrade. VPMM Replaces Existing Pumps, Motors, Relief Valves, Check Valves, Discharge Filters, Pump Running Pressure Gauges,
James McIntyre VRF Training Manager V5 Key Components.
Industrial Resources, Inc.
UNIT III ENGINE SYSTEMS
Quick Start Guide for Flex Flow Pump
Automotive Heating And Air Conditioning
14 Refrigerant Recovery, Recycling, and Recharging.
In-feed and Amine Sweetening 11/4/09
DELTAK HEAT RECOVERY STEAM GENERATOR
Student CD for Commercial Refrigeration for A/C Technicians Chapter 12 Ice Machines.
SB Packing Automatic Downpuller Power Unit
Vertical Pressure Filters
Troubleshooting 11/14/2018 Water King Service Seminar.
Overfill Prevention Technology and Maintenance
Horizontal Installation Overview
Preventative Maintenance & Service
BASIC PNEUMATICS.
Start Up Procedures and Recommendations for Factory Authorized Equipment Start Up.
Presentation transcript:

Welcome Growers Discover the Dosmatic Difference Installing your Dosmatic injector for years of service.

Congratulations You’ve purchased the best chemical injector available No extra cost for proprietary composite body, which exceeds PVDF for chemical compatibility and for mixing aggressive chemicals. No extra cost for built-in on/off switch, which allows user to stop the injection—but not the system. Separate internal mixing chamber to prevent chemical contact with motor piston—for longer life and uniform mixing. Highest standard operating pressure in the industry, Minimizing pressure surge damage. Industries Best 3 Year Limited Warranty

INSTALLATION I just received my unit. What are some of the first things I should do? Read your installation manual! If you did not receive one with the unit call Customer Service (800) Be sure to remove the shipping red caps at the inlet and outlet openings and at the suction tube fitting opening. Each unit is water pressure tested before shipping. Minute amount of water remains. The red caps prevent leakage during shipment. When installing into a PVC line you may need: pipe cutters, pipe wrench, PVC glue primer, Teflon tape and your fittings. What tools will I need to install my injector?

Why is a water filter important? –A water filter prevents debris such as sand from entering the motor of the injector which can cause premature failure in the injector. This is especially important if your water source is from a well or pond. Install a 140 mesh/104 micron filter or finer on the inlet side of the injector. Dosmatic carries the Twist II Clean ® ¾”, 1” or 2” filters that can be ordered with your injector. Failure to use an inline filter can void any warranty. Dosmatic recommends that you install a 140-mesh/104 micron in-line water filter in front of your injector. Depending on your water condition, it may be necessary to install larger mesh filters in series between the water source and the 140-mesh/104 micron filter. What additional equipment is required for a proper installation?

A back-flow preventer is required by ALL city ordinances to prevent back up of solutions into drinking lines and potable water supplies. An anti-siphon valve is recommended to prevent solution from being siphoned out when the upstream valve is shut off. The anti-siphon valve must be installed 6” above the highest downstream piping. You should always have a way to take the unit off-line for maintenance or storage when not in use. A three valve by-pass system will allow you to do this. See manual for examples. You may also want to install pressure regulators and gauges in your system. An EC (electrical conductivity) meter or TDS (total dissolved solids) meter is also helpful to verify the accuracy of the unit on a monthly basis. A water hammer arrester is highly recommended if you are operating quick closing, solenoid valves, pneumatic valves or even hand-operated ball valves on your watering system. Additional Installation Equipment

What water line temperature and pressure should I maintain? Install the Dosmatic injector in a cold water line - no more than 100° Fahrenheit or 38° Celsius - with a water pressure applicable for the model you are installing. Pressure should be regulated to the lowest pressure required for final delivery. Water pressure greater than recommended can cause permanent damage to the injector. (Refer to the specifications for the model you are installing)

The arrows on the lower injector body indicate direction of water flow and to help assure proper installation. On all models the arrow points in the direction of the water flow. What are the arrows on the injectors for?

Dosmatic recommends no more than a 15’ vertical hose and no more than a 50’ horizontal hose from the solution container to the injector (depending on viscosity). How high above the solution container can I install my injector?

Contact Information Dosmatic Customer Service Website Tech support ASK FOR LEO Richard L Smith Hort Sales Manager Cell Office