Instrumental Analysis

Slides:



Advertisements
Similar presentations
GAS CHROMATOGRAPHY ENVE 202 Dr. Aslıhan Kerç.
Advertisements

Infrared Spectroscopy
Drug Analysis.
Structure Determination: MS, IR, NMR (A review)
17.1 Mass Spectrometry Learning Objectives:
Lecture 8. GC/MS.
In carbon-13 NMR, what do the number of peaks represent?
Based on McMurry’s Organic Chemistry, 6th edition ©2003 Ronald Kluger
Chromatography and Instrumentation. Invented by a Russian Botanist Mikhail Tswett in 1903 He used chromatography to separate the colour pigments in plants.
Gas Chromatography And Mass Spectrometry
Structural Analysis AH Chemistry Unit 3(d). Overview Elemental microanalysis Mass spectroscopy Infra-red spectroscopy NMR spectroscopy X-ray crystallography.
Analytical Chemistry Option A Part 1: Mass Spectrometry & H-NMR.
Determining the Structure of an Organic Compound
Types of Chromatography Liquid chromatography versus gas chromatography? Applications? Volatile  GC Non-volatile  LC.
Chromatography Year 12.
Understanding infrared spectroscopy
What Are Some Types of Spectroscopy ?
Chapter 12 Mass Spectrometry and Infrared Spectroscopy
 PART Requirements for Spectroscopic Techniques for Polymers 1. High resolution 2. High sensitivity (>1%) 3. High selectivity between molecular.
KHS ChemistryUnit 3.4 Structural Analysis1 Structural Analysis 2 Adv Higher Unit 3 Topic 4 Gordon Watson Chemistry Department, Kelso High School.
Forensic Drug Analysis
Chemical Analysis. Analytical Techniques When chemical evidence is collected at a crime scene, it must be run through an instrument. These instruments.
1 University of Petra Faculty of Science & Arts Department of Chemistry Seminar I.R Spectroscopy By Firas Al-ouzeh Supervisor : Nuha I. Swidan Summer 2007.
Chapter 6 - Chromatography
Chromatography Chapter 6.
Magnet Analytical Chemistry Unit 4
Separation Science Differences in IMFs can be used to separate chemical substances for further analysis. Differences in IMFs can be used to separate chemical.
By: Thilag.k & Stephen. What is Hpcl??? Hplc or high performance liquid chromatography is the most widely used analytical separation technique. The difference.
Swami Sivananda State Secondary School
Spectroscopy. Spectroscopy – Getting Ready  What happens when an electron absorbs energy?  What kind of energy can cause this to happen?  Why do different.
Year 12 Chemistry Unit 3 – AOS 1 Chemical Analysis.
Unit 11:Data processing and analysis. A.Infrared spectroscopy B.Mass spectrometry C.X-ray diffraction/crystallography D.H NMR.
Infrared Spectroscopy
Chapter 12 Infrared Spectroscopy Jo Blackburn Richland College, Dallas, TX Dallas County Community College District  2006,  Prentice Hall Organic Chemistry,
Chapter 2: IR Spectroscopy Paras Shah
Analytical methods. Chromatography – general principles Mobile phase Stationary phase Compound for analysis - solute.
12. Structure Determination: Mass Spectrometry and Infrared Spectroscopy Based on McMurry’s Organic Chemistry, 6 th edition.
11.3: Analytical techniques can be used to determine the structure of a compound, analyze the composition of a substance, or determine the purity of a.
Methods of Chemical Analysis. Selecting an Analytical Technique  Organic vs. Inorganic materials  Organic:  Inorganic:  Quantitative vs. Qualitative.
Spectroscopy Measures light (radiation) absorbed by species in solution. Some radiation is absorbed by ground state electrons in atoms or molecules. Radiation.
0 Chromatography is a method of physically separating mixtures of gases, liquids, or dissolved substances. Chromatography can be used to identify drugs,
HPLC.
Infrared Spectroscopy
Chemistry 2412 L Dr. Sheppard
California State University, Monterey Bay CHEM312
Chromatography and Instrumentation. Chromatography Separate Analyze Identify Purify Quantify Components Mixture Chromatography is used by scientists to:
Infrared Spectroscopy
Demonstrate understanding of spectroscopic data in chemistry Chemistry A.S internal credits.
IB NOTES: Modern Analytical Chemistry. Definitions: Qualitative Analysis: The detection of the __________________ but not the __________ of a substance.
Instrumentation. Chromatography Chromatography is the collective term for a set of laboratory techniques for the separation of mixtures. It involves.
CHROMATOGRAPHY Chromatography is used to separate and analyse small amounts of mixtures Methods involve a stationary phase and a mobile phase. There are.
Organic Analysis Basic concepts. Elements and Atoms Fundamental building block of all substances is the element. Fundamental building block of all substances.
Absorption Spectroscopy
2008 SPECIFICATIONS HPLC and GAS CHROMATOGRAPHY A guide for A level students KNOCKHARDY PUBLISHING.
Chapter 5 – Organic Analysis
A guide for A level students KNOCKHARDY PUBLISHING
Chromatography- TLC & HPLC
Organic and Inorganic Chemical Analysis
Instrumental Analysis
A guide for A level students KNOCKHARDY PUBLISHING
Introduction and Principle of IR Spectrophotometry
Organic Instrumentation
Introduction Spectroscopy is an analytical technique which helps determine structure. It destroys little or no sample. The amount of light absorbed by.
Chromatography Daheeya Alenazi.
化工群英文示例 沙鹿高工 簡佩琳.
A guide for A level students KNOCKHARDY PUBLISHING
Instrumentation.
CHROMATOGRAPHY.
Presentation transcript:

Instrumental Analysis

Instrumentation Paper Chromatography GC – Gas Chromatography HPLC- High Performance Liquid Chromatography IR – Infrared Spectroscopy UV-Vis Spectroscopy MS – Mass Spectrometry NMR – Nuclear Magnetic Resonance

Chromatography Chromatography is a method of separating mixtures by their attraction to a stationary phase. The Stationary phase is chosen due to its polarity. The mixture to be separated is dissolved in a substance or carried by a substance that helps it travel past the stationary phase. The solvent is called the mobile phase. As the solvent travels, the parts of the mixture that are more attracted to the stationary phase move slower than the parts that are less attracted.

Paper Chromatography Can be done with drugs, inks, dyes, etc. Mobile phase is usually an organic solvent like methanol, hexane, or carbon tetrachloride. Stationary phase can be paper or a chromatography “plate.”

Gas Chromatography Sample is injected into a port and mixed with a carrier gas. (could be nitrogen or helium) Gas is heated by an oven and runs through a very long coiled silica column that contains the stationary phase. Gas comes out the other end and the parts of the mixture go through a detector (flame or electric) which determines when they have arrived. The retention time (how long inside the column) is used to identify the parts. Now just used to separate the components before entering a Mass Spec or IR.

Chromatograph Not only identifies, but by integrating under the curve you can determine quantities present in the mixture as well. Used to do it by hand, computers are wonderful!

HPLC A column is created with a packed stationary phase made up of tiny granules. The mixture is dissolved in a solvent like water methanol, acetonitrile. Instead of letting gravity pull the liquid through, it is put under high pressure anywhere from 50 – 1000 atmospheres. Also used as a separator before passing the mixture through another detector.

IR Spectroscopy When infrared radiation is absorbed by a molecule, it causes the bonds to bend and stretch. This energy is absorbed by the molecule and transferred to kinetic energy, so an absorption spectrum can be created. Different bonds absorb at different wavelengths and in different amounts, so it is possible to identify each substance by its unique spectrum.

Movements Asymmetric stretching Symmetric Stretching Scissoring Rocking Twisting Wagging

Absorption Regions Typical detectors measure the absorbance in the 1000-4000 cm-1 range (called wavenumbers) v = 1/λ or the number of wavelengths per distance. Wavelengths would be in the 2000 – 20000nm range. Functional groups and double bonds have distinct locations and shapes on the spectrograph that makes them easier to pick out. Interaction with other parts of the molecule further complicates the exactness.

Functional group absorption OH bonds tend to have large and broad absorbencies. Double bonds tend to be sharp spikes Below 1500 is called the fingerprint region and is tough to identify particulars alone.

IR of Morphine

UV-Vis Spectroscopy Deals with absorption of visible and near UV light. Causes electrons to transition to higher energy levels. Energy is absorbed when those transitions occur. Can be used for metals, biological macromolecules, and conjugated organic compounds.

Mass Spectroscopy Works by breaking the molecules up into fragments of varying masses. Fragments are ionized (carbocations) at the injection site. Fragments pass through a quadrapole which changes in frequency causing ions to oscillate while passing through. Different mass ions will be more or less effected. At each resonance frequency a specific ion will pass through.

Mass Spectroscopy The mass spectrometer changes the frequency so only one mass ion will pass through at a time. As each ion passes through it gets detected at the other end. Each fragment can then be determined by its mass, and the largest fragments can be use to determine the molar mass of the compound.

Quadrapole Mass Spec

Mass Spectrograph

Nuclear Magnetic Resonance NMR uses magnetic fields to cause nuclei of atoms to resonate. Different nuclei will absorb and release photons at different energies which enables detection. Electrons also create magnetic fields that shield the nucleus. This shielding causes changes in the resonance energies of the nuclei which is related to electron density. Can help determine the structure of complex molecules. Usually focused on hydrogen nuclei. Does not destroy the sample.