PRESENTED BY : HATIM DINI.  INTRODUCTION  INDIRECT METHOD  GENERAL FACTS  PULPATORY METHOD  AUSCULATORY METHOD  ULTRASOUND METHOD  OSCILLOMETRIC.

Slides:



Advertisements
Similar presentations
Blood Pressure and Flow Measurements
Advertisements

Blood Pressure.
Heart Rate, Blood Pressure, and Exercise. Blood Pressure Made up of two numbers: –systolic blood pressure –diastolic blood pressure. Written as: Systolic/Diastolic.
Pulse palpation Pulse pressure  The pressure felt as the blood in the artery surges through the point that has pressure applied.
Measurement of CV variables. In vitro Total control of confounding variables –Vasomotion, temperature changes, autoregulation, mean BP Most accurate because.
Monitoring The Emergency Patient ABDULRAHMAN SINDI ( Emergency Medicine Resident)
Ακριβής και αξιόπιστη μέτρηση ΑΠ
Arterial Catheters Systemic arterial blood pressure is most accurately measured by placing a catheter directly into a peripheral artery. Peripheral arterial.
Measuring Blood Pressure
Chapter 5 Part Two Blood Pressure and flow by Ibrhim AlMohimeed BMTS /3/2013.
Chapter 5 Part Three Blood Pressure and flow by Ibrhim AlMohimeed BMTS /3/2013.
Vital Signs Chapter 27 Copyright © 2009, 2006 by Saunders, an imprint of Elsevier Inc. All rights reserved. 1.
Blood pressure measurement PHCL 326 (1+1) Clinical skills for pharmacists.
Copyright 2002, Delmar, A division of Thomson Learning Chapter 9 General Survey and Vital Signs.
Assessing Heart Rate & Blood Pressure. Your pulse represents arterial palpation of the heartbeat using your fingertips. The pulse may be palpated in any.
DEPARTMENT OF ENGINEERING SCIENCE INSTITUTE OF BIOMEDICAL ENGINEERING Marco F Pimentel, Graduate Student, Centre for Doctoral Training in Healthcare Innovation,
What is Blood pressure? HYDROSTATIC FORCE OF THE BLOOD ONTO THE WALLS OF THE BLOOD VESSEL (RESISTANCE)
Vital Signs Medical Science 1. Lesson Objectives Understand What vitals are and how to document them Learn How to: Take Pulse Rate Take Respiration Rate.
BLOOD PRESSURE. Arterial Blood Pressure (BP) Is a measure of the force that the circulating blood exerts against the arterial wall OR The pressure force.
Blood Pressure By Dr. Ola Mawlana.
Blood pressure.
Blood Pressure— The driving force Stephen Hales 1733 Blood pressure (hydrostatic pressure) is the force exerted by the blood against any unit area of vessel.
Arterial Blood Pressure
Blood Pressure Assessment
Chapter 13 Blood Pressure Monitoring. Originates from the heart Value depends on 3 factors: cardiac output diameter of arteries the quantity of blood.
Blood pressure monitoring Monica Morosan. AAGBI standards of monitoring A - Induction and Maintenance of Anaesthesia 1. Pulse oximeter 2. Non invasive.
Understanding Blood Pressure. Your heart sends blood to the whole body Oxygen Nutrients Carries away waste Heart Parts: Arteries Capillaries Veins.
Monday, June 9,  Let’s review the 4 vital signs!  Heart rate  Respiratory rate  Blood pressure  Temperature.
Resident Categorical Course
Arterial Blood Pressure Taking a person’s Blood Pressure with a sphygmomanometer.
Measuring and Recording a Blood Pressure. Blood Pressure (BP) is one of the four vital signs you will be required to take. It is important that your recording.
Copyright © 2006 Pearson Education, Inc., publishing as Benjamin Cummings Human Anatomy & Physiology SEVENTH EDITION Elaine N. Marieb Katja Hoehn PowerPoint.
VITAL SIGNS BLOOD PRESSURE (BP).
Copyright 2002, Delmar, A division of Thomson Learning Chapter 9 General Survey and Vital Signs.
Cardinal signs, reflects body’s physiological status
إعداد : عــلي عــاشور. Objective; To practice the measurements of Heart rate, Respiratory rate, Blood pressure and Temperature إعداد : عــلي عــاشور.
VITAL SIGNS. Vital Signs Temperature Breathing +Pulse Oximeter Pulse Blood pressure Pain (5 th VS)
Blood Pressure Clinical Science Applied to Nursing CopyrightCSAN2005CardiffUniversity.
Sarah Gillies Ultrasound Sarah Gillies
 Blood pressure means the pressure exerted by blood on the wall of the arteries.  Unit of Measurement-----mmHg  Normal BP  Systolic (100—14ommHg)
© 2009 The McGraw-Hill Companies, Inc. All rights reserved Vital Signs: Blood Pressure.
VITAL SIGNS BLOOD PRESSURE PULSE TEMPERATURE RESPIRATIONS.
Electromyography (EMG)
12.2 Monitoring the Human Circulatory System Within the heart, the sinoatrial (SA) node (the pacemaker) stimulates.
CopyrightThe McGraw-Hill Companies, Inc
Cardiac Cycle aortic pressure ventricular pressure atrial pressure
Blood Pressure Clinical Science Applied to Nursing CopyrightCSAN2005CardiffUniversity.
Higher Human Biology. Blood Pressure  The force exerted by blood against the walls of the blood vessels  Measured in mmHg (millimetres of mercury) 
Forces acting on blood during circulation
BLOOD PRESSURE MEASUREMENT Sharon Jones Chapter 17.
Blood pressure measurement Presented by -Deepika Jain -Divya Jain
Please get your assigned computer. Do not turn on until instructed.
Key Points Definition of Blood Pressure A.The measurement of the force of blood against artery walls. 1. Force comes from the pumping of the heart 2. If.
U.S ARMY HEALTH CARE B/P LAB. 2 SGT Chase Johnson Army Health Care Recruiter U.S Army Medic ( 68W) Emergency Medical Technician (NREMT) Advance Cardiac.
The Cardiac Cycle. Learning Objectives  To identify & describe the main parts of the cardiac cycle  To describe how the cardiac cycle is controlled.
FloTrac Sensor & Vigileo Monitor
Blood Pressure. Blood pressure is the pressure exerted by circulating blood upon the walls of blood vessels, and is one of the principal vital signs.
Carditech, California, USA University Of West Bohemia, Czech Republic
The Arterial Blood Pressure
Blood Pressure.
Measurement of Arterial Pressure
Blood Pressure August 2015 Blood Pressure.
Blood pressure measurement
Data Collection Blood Pressure.
Labs 33A Circulation.
Blood flow and blood pressure
Measuring Blood Pressure
Labs 33 Circulation.
Labs 33A Circulation.
Blood Pressure (BP) -practical
Presentation transcript:

PRESENTED BY : HATIM DINI

 INTRODUCTION  INDIRECT METHOD  GENERAL FACTS  PULPATORY METHOD  AUSCULATORY METHOD  ULTRASOUND METHOD  OSCILLOMETRIC METHOD  TONOMETRY METHOD  DIRECT METHOD  EXTRAVASCULAR SENSOR  INTRAVASCULAR SENSOR  DISPOSABLE SENSOR  SUMMARY

One of the oldest physiological measurements Originates from the heart Value depends on 3 factors: cardiac output diameter of arteries the quantity of blood Commonly refers to arterial blood pressure Values should be lower than 120 / 80 mmHg (systolic pressure (SP) / diastolic pressure (DP)) peripheral resistance Observation of blood pressure allows dynamic tracking of pathology and physiology affecting to the cardiovascular system, which has profound effects to all other organs of the body

Pulse pressure (PP) = SP-DP MP = DP+PP/3 Mean pressure (MP) average pressure during one cardiac cycle driving force of the peripheral perfusion. an estimate can be done by using an empirical formula: SP and DP may vary significantly throughout the arterial system but MP is quite uniform (in normal situations) High value increases the risk of heart attack and strokes Low value increases the risk of lower oxygen perfusion e.g. in brains However, the ’normal values’ differ from person to another

Indirect measurement = non-invasive measurement Brachial artery is the most common measurement site Close to heart Convenient measurement Other sites are e.g.: forearm / radial artery wrist (tends to give much higher SP) The most common indirect methods are auscultation and oscillometry

An occlusive cuff is placed on arm and inflated to P > SP. Then the cuff is deflated gradually and the measurement of blood flow is done cuff The occlusive cuff should be of a correct size in order to transmit the pressure to the artery evenly and thus to obtain accurate results A short cuff requires special attention in placement. Longer cuff reduces this problem. The cuff should be placed at the heart level in order to minimize the hydrostatic effects

When the cuff is deflated, there is a palpable pulse in the wrist. P = BP Several measurements should be done as the respiration and vasomotor waves modulate the blood pressure levels +) The blood pressure can be measured in noisy environment too ADVANTAGES -) Only the systolic pressure can be measured (not DP) DISADVANTAGES -) The technique does not give accurate results for infants and hypotensive patients cuff +) Technique does not require much equipment

The Korotkoff sounds are ausculted with a stethoscope or microphone (automatic measurement) Pulse waves that propagate through the brachial artery, generate Korotkoff sounds. There are 5 distinct phases in the Korotkoff sounds, which define SP and DP Also with this method, several measurements should be done. The frequency range is Hz and the accuracy is +/- 2mmHg (SP) and +/- 4mmHg (DP)

-) The observations differ from observer to another -) A mechanical error might be introduced into the system e.g. mercury leakage, air leakage, obstruction in the cuff etc. -) The observations do not always correspond with intra-arterial pressure -) Auscultatory tecnique cannot be used in noisy environment +) Auscultatory technique is simple and does not require much equipment ADVANTAGES DISADVANTAGES -) The technique does not give accurate results for infants and hypotensive patients

A transcutaneous (through the skin) Doppler sensor is applied here. The motion of blood-vessel walls in various states of occlusion is measured. The frequency difference between transmitted (8 MHz) and received signal is Hz and it is proportional to velocities of the wall motion and the blood. The vessel opens and closes with each heartbeat when DP < P < SP cuff

+) Can be also used in noisy environment ADVANTAGES & DISADVANTAGES +) Can be used with infants and hypotensive individuals -) Subject’s movements change the path from sensor to vessel As the cuff pressure is increased, the time between opening and closing decreases until they coincide Systolic pressure Again as the cuff pressure is decreased, the time between opening and closing increases until they coincide Diastolic pressure

The intra-arterial pulsation is transmitted via cuff to transducer (e.g. piezo-electric) The arterial pressure oscillations (which can be detected throughout the measurement i.e. when P > SP and P < DP) are superimposed on the cuff pressure SP and DP are estimated from the amplitudes of the oscillation by using a (proprietary) empirical algorithm. cuff The cuff pressure is deflated either linearly or stepwise

DISADVANTAGE -) Many devices use fixed algorithms leading to large variance in blood pressures +) In the recent years, oscillometric methods have become popular for their simplicity of use and reliability. ADVANTAGES +) MP can be measured reliably even in the case of hypotension

A sensor array is used here, because at least one of the pressure sensors must lay directly above the artery Linear array of pressure sensors is pressed against a superficial artery, which is supported from below by a bone (radial artery). The pressure is increased continuously and the measurements are made when the artery is half collapsed When the blood vessel is partly collapsed, the surrounding pressure equals the artery pressure. The hold-down pressure varies between individuals and therefore a ’calibration’ must be done

ADVANTAGES +) Can be used for non-invasive, non-painful, continuous measurement DISADVANTAGES -) Relatively high cost -) The wrist movement and tendons result in measurement inaccuracies

Direct measurement = Invasive measurement Used only when essential to determine the blood pressure continuously and accurately in dynamic circumstances A vessel is punctured and a catheter (a flexible tube) is guided in The most common sites are brachial and radial arteries but also other sites can be used e.g. femoral artery A division is made into extravascular and intravascular sensor systems This method is precise but it is also a complex procedure involving many risks….

The sensor is located behind the catheter and the vascular pressure is transmitted via this liquid-filled catheter. The ’normal’ measuring system The actual pressure sensor can be e.g. strain gage variable inductance variable capacitance optoelectronic piezoelectric, etc…

The hydraylic link is the major source of errors. The system’s natural frequency may be damped and degraded due (e.g.): too narrow catheter too long tubing various narrow connections air bubbles in the catheter The catheter-sensor system must be flushed with saline-heparine solution every few minutes in order to prevent blood from clotting at the tip..

Normally the interesting frequency range is 0 – 100 Hz. If only MP is measured the bandwidth is 20 Hz (harmonics > 10 are ignored)

The sensor is located in the tip of the catheter. This way the hydraulic connection is replaced with an electrical or optical connection +) The frequency response is not limited by the hydraulic properties of the system. No time delay. -) Breaks easily -) More expensive +) Electrical safety and isolation when using fiber optics The dispacement of the diaphragm is measured

Disposable sensors decrease the risk of patient cross-contamination and reduce the amount of handling by hospital personnel Cheaper and more reliable than reusable pressure sensors General on System Parameters Even minute air bubbles in catheter have a dramatic effect on frequency response The natural frequency and the length of the catheter have a following relationship: The catheter diameter has a linear relationship to natural frequency Stiffer catheters have a higher frequency response Teflon Polyethylene Silicon rubber BETTER WORSE

BLOOD PRESSURE Describes the physiology and pathology of cardiocvascular system ”Normal” values are 120 / 80 mmHg High values may lead to heart attack and strokes Low values may lead to low oxygen perfusion All direct methods require skin punctuation and a use of catheter. Methods are used only when continuous and accurate measurements are needed. Almost all indirect methods rely on an occlusive cuff which is placed on the bracial artery. The actual measurement is done when the cuff is deflated