Day 4 Part 2 Technician’s Guide & Workbook for Home Evaluation and Performance Improvement.

Slides:



Advertisements
Similar presentations
BUILDING ENERGY CODES UNIVERSITYwww.energycodes.gov/BECU 1 BUILDING ENERGY CODES UNIVERSITY ANSI/ASHRAE/IES Standard Scope and Application April.
Advertisements

TOUR OF NIST MANUFACTURED RESEARCH HOUSE Andy Persily, Steve Nabinger, Steve Emmerich, Cindy Howard Reed Building and Fire Research Laboratory National.
Energy Efficiency in Rehab Late 1980s – RIP Early 1990s – energy standards developed Approx 20 pages Prescriptive Lowering energy usage Controlling moisture.
1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – July 2012eere.energy.gov Building Science Basics WEATHERIZATION INSTALLER/TECHNICAN FUNDAMENTALS.
“Do not take anyone’s advice as to how this building should be assembled.”
Heating, Ventilating, and Air-Conditioning (HVAC)
ENERGY STAR Qualified Homes
1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov Energy Movement WEATHERIZATION ENERGY AUDITOR SINGLE FAMILY.
1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – July 2012eere.energy.gov Loose-Fill Insulation: Preparation and Installation WEATHERIZATION.
West Virginia's residential building code is mandatory statewide; however, adoption by jurisdictions is voluntary. The 2013 West Virginia Legislature.
The House as a System 1. Air Temperature and Water Vapor.
Energy Rating Index Performance Path Speaker Name Speaker Affiliation.
1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – December 2012eere.energy.gov Attic Ventilation WEATHERIZATION ENERGY AUDITOR SINGLE FAMILY.
Total Flooding Systems
Standardized Curriculum WAP Training Plans and Resources.
Placing Vapor Distribution Systems and Appliances into Operation MODULE 5 Validating Combustion Air.
2012 International Fire Code Adopted as the minimum fire safety standard by the State of Wyoming City of Sheridan must adopt the minimum standard to retain.
Chapter 4: Air Leakage Control: Materials and Techniques
HVACR416 - Design Pressure Measurement Part 2. Pressure Measurement Several pressure measurements exist. They all measure the same things, the force of.
PTCS DUCT SEALING SPECIFICATIONS The Perfect Spec : Simple as possible Achievable by the motivated, not just the true believer Assure that energy savings.
1 ENERGY STAR ® and Air Sealing Products: New Program Requirements Doug Anderson, US EPA 1.
Copyright 2008, International Code Council 2012 IECC ® for SERBCA Based on the 2012 International Energy Conservation Code.
Your House as a Healthy System Bruce Stahlberg. Improvements / Remodeling When one has finished building one's house, one suddenly realizes that in the.
Ontario Building Code Revision effective Jan 1, 2015
1 Connecticut’s New Energy Code Connecticut ASHRAE Tech Session October 13, 2011 Frederick F. Wajcs, Jr. Senior Energy Engineer Connecticut Light and Power.
Residential Ventilation & IAQ Requirements for Existing Homes: Second Discussion Proposed Specification Outline Regional Technical Forum November 9 th,
Brought to you by: Connecticut Energy Code Frederick F. Wajcs Senior Energy Engineer Northeast Utilities February 10, 2011.
SEEA Presentation to SEES March 2006 SEEA Presentation to SEES February 2006 SOUTHEAST ENERGY EFFICIENCY ALLIANCE.
Massachusetts New Homes with ENERGY STAR ® The sponsors of the Massachusetts New Homes with ENERGY STAR are Bay State Gas, Berkshire Gas, Cape Light Compact,
HVACR311 – Electrical for Refrigeration International Mechanical Code Relating to Refrigeration.
1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – December 2012eere.energy.gov Energy Movement WEATHERIZATION ENERGY AUDITOR SINGLE FAMILY.
Residential Weatherization and Ventilation Subcommittee Seeking RTF Direction on Ventilation and IAQ Requirements May 3, 2011 Subcommittee: Residential.
ASHRAE A Ventilation Standard for Residential Structures Ventilation and Acceptable Indoor Air Quality in Low- Rise Residential Buildings.
Residential Weatherization and Ventilation Subcommittee Presentation to the Regional Technical Forum August 30, 2011.
Insulation and Infiltration
Ben Larson 1 November th Avenue NE, Seattle, WA (206)
Residential Ventilation & IAQ Requirements for Existing Homes History, ASHRAE 62.2, and the RTF’s Role Regional Technical Forum October 13 th, 2009.
HVACR416 - Design IAQ / Ventilation / Pathways. Ventilation Most air handling units distribute a mix of outdoor air and re-circulated indoor air. Some.
Updated Space Heater Policy For Weatherization -- Draft National Weatherization Training Conference Orlando, FL December 10, 2007.
HVACR416 - Design Heat Loss / Heat Gain Part 1. Why? The primary function of Air Conditioning is to maintain conditions that are… o Conductive to human.
1 HVACR318 – Refrigeration II International Mechanical Code Relating to Refrigeration.
1 | Weatherization Assistance Program: The Federal Perspective (Part 1)eere.energy.gov NASCSP 2011 Mid-Winter Training Conference Weatherization Assistance.
Proposed Changes to PTCS Duct Standards April 7 th, 2009 Regional Technical Forum.
1 1 Weatherization & Indoor Air Quality Impacts of Weatherization on Air Quality and Comfort Inside Your Home Prepared with the assistance of Jed Harrison,
VENTILATION AND FENESTRATION
Zone 4 R-38 Ceilings U-0.35 Windows, Doors R-13 Walls R-19 Floors R-10 Foundations.
Day 3 Part 3 Technician’s Guide & Workbook for Home Evaluation and Performance Improvement.
Day 4 Part 3 Technician’s Guide & Workbook for Home Evaluation and Performance Improvement.
Day 2 Part 1 Technician’s Guide & Workbook for Home Evaluation and Performance Improvement.
3.0 Comprehensive Performance Audit Fossil Fuel Appliances Health & Safety 3.2.
Day 1 Part 4 Technician’s Guide & Workbook for Home Evaluation and Performance Improvement.
Day 2 Part 2 Technician’s Guide & Workbook for Home Evaluation and Performance Improvement.
Day 4 Part 1 Technician’s Guide & Workbook for Home Evaluation and Performance Improvement.
Day 3 Part 2 Technician’s Guide & Workbook for Home Evaluation and Performance Improvement.
1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov Attic Ventilation WEATHERIZATION ENERGY AUDITOR SINGLE FAMILY.
Technician’s Guide & Workbook for Home Evaluation and Performance Improvement.
Day 1 Part 1 Technician’s Guide & Workbook for Home Evaluation and Performance Improvement.
Part 15 Technician’s Guide & Workbook for Duct Diagnostics and Repair.
Part 13 Technician’s Guide & Workbook for Duct Diagnostics and Repair.
Part 16 Technician’s Guide & Workbook for Duct Diagnostics and Repair
Math Review CAZ Volume and Air Free CO PPM Calculations
Part 4 Technician’s Guide & Workbook for Duct Diagnostics and Repair
National WAP Evaluation: Radon
Part 12 Technician’s Guide & Workbook for Duct Diagnostics and Repair
Technician’s Guide & Workbook for Duct Diagnostics and Repair
Things you need to know before you play the game
Flip The Long House Let’s imagine the Long house example in Manual J has undergone a house flipping/energy savings update. The insulation was increased,
Manual D Duct Sizes Room Cooling CFM % Total CFM Heating CFM Kitchen GR Dining Bed Bed 3.
A Ventilation Standard for Residential Structures
Presentation transcript:

Day 4 Part 2 Technician’s Guide & Workbook for Home Evaluation and Performance Improvement

Implementing Identified Performance Improvements (IIPI) 6.0

IIPI Safety 6.1

IMPLEMENTING IDENTIFIED PERFORMANCE IMPROVEMENTS (IIPI) The Technician who is in charge of the contracted performance and safety retrofit installation must make sure that the building performance improvement(s) selected by the homeowners are all done in accordance with recognized industry standards and good practices.

IMPLEMENTING IDENTIFIED PERFORMANCE IMPROVEMENTS (IIPI) The Technician cannot make any exclusions or variations from the prescribed work scope that result in the home operating improperly, or that will increase the risk of flue gas spillage, back- drafting, carbon monoxide production, or moisture problems within the home.

IMPLEMENTING IDENTIFIED PERFORMANCE IMPROVEMENTS (IIPI) Slide presentation 6.2 covered sections 5.1 through 5.7 in 12 QH. Those sections cover specific items for the main areas addressed in the standard the Technician needs to be aware of during the implementation phases of the home improvement project.

IMPLEMENTING IDENTIFIED PERFORMANCE IMPROVEMENTS (IIPI) It should be noted that the items listed are a basic outline and the manufacturers details for installation need to be followed and all of the local code requirements need to be met too.

IIPI Safety CO, spillage, and drafting issues need to be addressed by implementing repairs and/or installing the appliance in compliance with local codes and the appliance manufacturer’s installation instructions. Full instructions for the Technician on combustion appliance testing and inspection are provided in previous presentations. (1.9, 3.6 & 5.1)

IIPI Safety Combustion air for fuel burning appliances must be done in accordance with one or more of the following as previously described: §9.3 of the 2015 National Fuel Gas Code, §304 of the 2012 International Fuel Gas Code or manufacturer’s installation instructions for gas- fired appliances,

IIPI Safety OEM instructions, unless not available then: §G2407 of the 2012 International Residential Code for appliances other than gas-fired appliances.

IIPI Safety CO detectors shall be installed in accordance with OEM instructions and 2012 International Residential Code §R315.

IIPI Safety When measures are performed that improve the envelope tightness and a Radon test has not been included in the contract, the Technician should recommend that a Radon test be done upon completion of the selected building improvements. Note: If Radon is found upon the completion of the work, the Technician will probably need that copy of the owner’s refusal to consider Radon as part of the original proposal (see Slide Presentation 6.9 Test Out Procedures).

Acceptable Documentation CO Detector Information CO Spillage Test documentation Records for other safety related testing done. For example Radon testing.

IIPI Envelope 6.2

Leakage Types

Ventilation = Leakage

Temperature Difference

Pressure Differences

Stack Effect

Wind Direction

IIPI Envelope Air sealing measures need to be prioritized to reduce the stack effect and inhibit moisture migration into attics and other interstitial spaces. Additionally, an effective and continuous thermal and pressure boundary shall be established through the installation of appropriate air sealing and insulation measures.

IIPI Envelope Air sealing and insulation strategies shall be designed to align the thermal and pressure boundaries to create a single continuous thermal envelope for the entire home. The following items should be considered when planning to accomplish those goals:

IIPI Envelope Air leakage paths need to be found and sealed when they exist between attached, or drive- under garages, and the living space.

IIPI Envelope When leakage paths are through enclosed cavities that cannot be accessed for sealing using conventional air sealing techniques, the following applications are acceptable to reduce airflow through the building envelope:

IIPI Envelope o Installation of high density pneumatically applied insulation - which complies with the insulation manufacturer’s directions. o Installation of air impermeable foam insulation.

IIPI Envelope Whenever air sealing represents 15% or more of the total building shell area, or whenever ducts outside the thermal envelope are sealed, the work scope must include pre-and post-installation blower door testing. So, if it was left out of the proposal…it still must be done and verified by the Technician who is overseeing the job.

IIPI Envelope All existing interior or exterior moisture issues shall be remediated prior to air sealing the building shell. Attic venting shall be in accordance with 2012 International Residential Code §R806 Roof Ventilation.

IIPI Envelope Repairs and renovations to pre-1978 homes that have evidence of lead paint: must have lead mitigation plans that comply with the EPA’s Renovation, Repair, and Painting (RRP) Program Rule (40 CFR Part 745).

Acceptable Documentation Records of repairs for moisture problem areas. Lead abetment records where required. Records for attic venting. Documentation of sealing completed.

IIPI Ventilation 6.3

IIPI Ventilation Where there are no code requirements for the design of outside/makeup air, that air should be set to comply with ASHRAE requirements, and should also meet the 2012 International Energy Code (IECC) requirements.

ASHRAE 62.2 Before OA solutions can be selected, the amount of OA required must be determined. ASHRAE 62.2 specifies three acceptable methods for determining the OA. When using any of these methods to determine OA, the total required ventilation rate (Q tot ) of OA must be greater than, or equal to, exhaust rates from kitchens and bathrooms.

ASHRAE 62.2 Before OA solutions can be selected, the amount of OA required must be determined. ASHRAE 62.2 specifies three acceptable methods for determining the OA. When using any of these methods to determine OA, the total required ventilation rate (Q tot ) of OA must be greater than, or equal to, exhaust rates from kitchens and bathrooms.

ASHRAE 62.2 Minimum exhaust rates for kitchens are 100 CFM intermittent or 5 air changes per hour (based on kitchen area), and for each bathroom, 50 CFM for intermittent applications, or 20 CFM for constant operation. However, for designs where there are less than 5 air changes per hour in the kitchen, vented range hoods are required Including appliance-range hood combinations.

62.2 Ventilation Table Method Ventilation Air Requirements in CFM Floor Area ft 2 Number of Bedrooms Less Than

62.2 Ventilation Sample Home A two-bedroom house with a 1,525 ft 2 conditioned floor area. as per ASHRAE When using Table 1a, the values provided are for 2 persons in a studio (or in a one-bedroom), and if the number of occupants is known, and greater than the table values, the additional occupants must be accounted for by adding 7.5 CFM per additional person to the table value.

62.2 Ventilation Table Method Ventilation Air Requirements in CFM Floor Area ft 2 Number of Bedrooms Less Than

62.2 Ventilation Table Method Ventilation Air Requirements in CFM Floor Area ft 2 Number of Bedrooms Less Than

62.2 Ventilation Table 1a Method Ventilation Air Requirements in CFM Floor Area ft 2 Number of Bedrooms Less Than

62.2 Ventilation Table 1b Method Ventilation Air Requirements in Cfm Floor Area ft 2 Number of Bedrooms Less Than MoreThan

62.2 Ventilation Formula Method The formula is: Q tot = 0.03 A floor x (N br + 1) Where: Q tot =Total required ventilation rate in cubic feet per minute (CFM) A floor = Floor area in square feet N br = Number of bedrooms. Not to be less than one; used to estimate the number of occupants for design purposes.

62.2 Ventilation Formula Method The formula is: Q tot = 0.03 A floor x (N br + 1) OA cfm = 0.03 (1525) + [7.5 x (2+ 1)] = CFM

62.2 Ventilation Alternative Method ASHRAE allows practitioners to use any alternative OA formulas that provide equivalent results to the ASHRAE 62.2 Table Rates.

Additional 62.2 Ventilation Formulas For infiltration credits and intermittent operation calculations, see: Appendix 1 Technician’s Guide & Workbook for Home Evaluation and Performance Improvement. Or If you are an ACCA Member Technical Bulletin

Ventilation Installation The Technician needs to install ventilation systems in accordance with OEM instructions. The system must also meet the local code requirements, and must be installed to meet the accepted industry practices. The following two requirements must also be met:

Ventilation Installation Mechanical ventilation airflow shall be measured in accordance with §5 in the Technician’s Guide & Handbook for Quality Installations as outlined in ANSI/ACCA 5 QI

Ventilation Installation Attic ventilation shall not be installed without first verifying the presence of an effective air barrier and thermal barrier between the attic and the living space. Refer to local codes for minimum requirements for insulation and ventilation.

Acceptable Documentation Documentation for the airflow measurements that meet the ventilation requirements should include the following: Test date. Location. Name of Technician. Data on the test equipment including models and serial numbers. Calculations and copies of the airflow data sheets. A copy of the ASHRAE 62.2 calculations, or the local code requirement calculations.