SAL COLLEGE OF ENGINEERING AHMEDABAD LIQUID LEVEL MEASUREMENT

Slides:



Advertisements
Similar presentations
ACTIVE LEARNING PROCESS
Advertisements

Mechanics of Materials II
Level Measuring Sensors
Industrial Instrumentation
Load Cell &DP Cell 2007-CHEM-17.
Instrumentation and Measurements Dr. Mohammad Kilani
FLOW measurements.
Thermo-energy audit Services for thermo-energy audit Flow measurement.
Lecture 2: Pressure Measurements
 A 'heat exchanger' may be defined as an equipment which transfers the energy from a hot fluid to a cold fluid. Here, the process of heating or cooling.
Measurement of force torque and pressure
SIGHT GLASS The sight glass is normally a graduated glass tube mounted on the side of the tank as shown in Fig This method is very simple and gives.
Pressure Sensors.
Pressure Measurement Muhajir Ab. Rahim
LIQUID LEVEL MEASUREMENT Liquid level refers to the position or height of a liquid surface above a datum line. Level measurement are made to ascertain.
CHAPTER 2 LEVEL MEASUREMENT
ACADs (08-006) Covered Keywords Calibrate, direct, inferred, transmitter calibration, gravity correction, density correction, hydrostatic head detector,
NorCal Tech 2005 Technical Conference
Level Sensors.
Method of Level Measurement
Flow Sensors.
CONTROL VALVE - THEORY & SIZING
Fluid Statics Lecture - 2.
Fuel Oil Systems Fuel Oil Systems consist of: Storage Tanks Pumps
Reciprocating pump Pumps are used to increase the energy level of water by virtue of which it can be raised to a higher level. Reciprocating pumps are.
EKT314/4 Electronic Instrumentation
Pressure and its Measurement
CENTRE OF EXCELLENCE (CHEMICAL SECTOR)
Lease Automatic Custody Transfer
Submitted by Waris jamal Praveen kumar gautam Shiv pratap singh Ramashwar kumar singh Under the guidence of Prof.safiulla khan.
HVAC523 Circulator Pumps.
NFPA 31 Standard for the installation of Oil- Burning Equipment
Chapter 14 PHYSICS 2048C Fluids. What Is a Fluid?  A fluid, in contrast to a solid, is a substance that can flow.  Fluids conform to the boundaries.
Mechanical Measurement and Instrumentation MECN 4600
Flow Measurement and Control. Orifice Meter The orifice meter consists of an accurately machined and drilled plate concentrically mounted between two.
Mechanics Physics project Name: Tamara Hall Form: 5B.
MEASUREMENTS AND INSTRUMENTATION.
Chapter 14 Fluids What is a Fluid? A fluid, in contrast to a solid, is a substance that can flow. Fluids conform to the boundaries of any container.
Fluids Unlike a solid, a fluid can flow. Fluids conform to the shape of the container in which it is put. Liquids are fluids the volume of which does not.
Chapter 19 Liquids.
Flow Measurement and Control
LEVEL MEASUREMENT BY, B.Raveender Singh.
Flow measurement.
Chapter 14 Fluids.
Beaker A beaker is a simple container for stirring, mixing and heating liquids.
Pressure A measure of the amount of force exerted on a surface area A measure of the amount of force exerted on a surface area.
Valves In Industry (Part 1)
Level Measurement. Level is another common process variable that is measured in many industries. The method used will vary widely depending on the nature.
GOVERNMENT ENGINEERING COLLEGE, BHARUCH (014) Chemical Engineering department SEM-iii Sub: fluid flow operation topic: orifice meter & rotAmeter Guid by:
Speed logs.
Submitted by Pradeep pataskar Roll no.11031M02034.
GUJARAT TECHNOLOGICAL UNIVERSITY (GTU) Mahatma Gandhi Institute Of Technical Education and Research Center, Navsari Affiliated with GTU Presentation on.
ABOUT INSTRUMENTATION Instrumentation is used in almost every industrial process and system, where consistent and reliable operations are required. Instrumentation.
G H PATEL COLLEGE OF ENGINEERING & TECHNOLOGY INSTRUMENTATION AND PROCESS CONTROL ( ) TOPIC: - LEVEL MEASUREMENT : DIRECT METHOD PREPARED BY: NAME.
Pacific school of Engineering Sub: I.P.C Topic: Pressure measurement Guided by Piyush modi Mayani Chintak Sudani Dhrutik Bhikadiya.
Government Engineering College Bharuch(014). Sub: Instrumentation And Process Control. Topic: Displacement float,Pneumatic balance and Magnetic level.
FLUID POWER CONTROL ME604C. FLUID POWER MODULE:02 ~ HYDRAULIC SYSTEM COMPONENTS.
G.H.PATEL COLLEGE OF ENGINEERING AND TECHNOLOGY
SUB:-FLUID MECHANICS TOPIC:-FLOW MEASUREMENT DEVICES SUBMITTED TO: KULDEEP SIR Government engineering college, valsad.
Electric Pressure Transducer
Author: Nurul Azyyati Sabri
Pressure Measurements
Instrumentation & Measurement
Mechanical Measurements and Metrology
GOVERNMENT ENGINEERING COLLEGE DAHOD
GOVERNMENT ENGINEERING COLLEGE, BHARUCH.
CENTRE OF EXCELLENCE (CHEMICAL SECTOR)
Piyush Modi Assist.Prof
Introduction of fuel feed system
Group members K17CE10 K17CE49 K17CE12. Introduction Classification of pressure Pressure measurement instruments Mechanical gauges.
Presentation transcript:

SAL COLLEGE OF ENGINEERING AHMEDABAD LIQUID LEVEL MEASUREMENT Prepared By, GAJERA DEEP (131130105009) PATEL VIRAJ (131130105049) VAGHASIYA DHAVAL (131130105060)

LEVEL MEASUREMENT In modern manufacturing industries which use many solvents, chemicals, steam and other liquids and in power plants which use vast amount of water, the accurate measurement of liquid level is very essential.

LIQUID LEVEL MEASUREMENT Generally, there are two methods used in industries for measuring liquid level. These are Direct Method Indirect Method Direct method use the varying level of the liquid as a mean of obtaining the measurement and the indirect method use a variable that changes with the liquid level to accurate the measuring mechanism.

1. DIRECT METHOD This is the simplest method of measuring liquid level. In this method, the level of the liquid is measured directly by means of the following level indicators i. Sight Glass / Gauge Glass ii. Float Type / Float - Operated Level Gauges iii. Torque Tube Displacer / Float Displacement Type Level Gauges

SIGHT GLASS / GAUGE GLASS Sight glass is used for the continuous indication of liquid level within a tank or vessel. A sight glass instrument consists of a graduated tube of toughened glass which is connected to the interior of the tank at the bottom in which the water level is required.

Fig.1 shows a simple sight glass for an open tank in which the liquid level in the sight glass matches the level of liquid in the tank. As the level of liquid in the tank rises and falls, the level in the sight glass also rises and falls accordingly. Thus, by measuring the level in the sight glass, the level of liquid in the tank is measured. In sight glass, it is not necessary to use the same liquid as in the tank. Any other desired liquid also can be used. Fig.2 shows a high pressure sight glass in which measurement is made by reading the position of the liquid level on the calibrated scale. This type of sight glass in high pressure tanks is used with appropriate safety precautions. The glass tube must have a small inside diameter and a thick wall.

Advantages Disadvantages Direct reading is possible Special designs are available for use up to 316°C and 10000 psi. Glassless designs are available in numerous materials for corrosion resistance. Disadvantages It is read only where the tank is located, which is not always convenient. Overlapping gauges are needed for long level spans Accuracy and readability depend on the cleanliness of glass and fluid

FLOAT DISPLACEMENT TYPE LEVEL MEASUREMENT These instruments work on the Archimedes principle according to which a body when placed in a liquid is buoyed up by a force equal to the weight of the displaced liquid, and the apparent change in weight of the body is directly proportional to the level of liquid in which it is placed. Torque tube is the most commonly used device for this purpose. The displacer is attached to a torque tube assembly whose rotary motion is used for read out/control. Otherwise, this instrument is rugged and simple in construction and reliable in operation. With selection of suitable material for float, float cage, and torque tube, it’s possible to use this instrument over a wide range of pressure and for many liquids.

Float Displacement Type Level Measurement

Advantages Disadvantages High accuracy Reliable in clean liquids Can be mounted internally or externally (external mounted unit can be disconnected for maintenance) Adaptable to liquid interface measurement Disadvantages Limited range, devices exceeding 1.2m in length are bulky and difficult to balance Cost increases appreciably for externally mounted units as pressure ratings increase External units may require stilling chambers

2. INDIRECT METHODS Following are the indirect methods of liquid level measurement generally used in industries. Hydrostatic pressure type Electrical methods Ultrasonic level sensor

i. HYDROSTATIC PRESSURE TYPE Hydrostatic pressure methods used for liquid level measurement are listed below. Pressure gauge method Air purge system Diaphragm box type Torque balance type

a. Air purge system Air purge (bubbler tube) is one of the most popular hydrostatic pressure types of liquid measuring system which is suitable for any liquid as shown in fig.

Advantages Pressure gauge can be placed above or below the tank level and can be kept as far away as 500 ft (12.7m) from the tank with the help of piping. Well - suited for measuring the corrosive/abrasive liquid.

b. DIAPHRAGM BOX METHOD The diaphragm box liquid level meter is shown in fig. and consist of two flanges in between which is contained a diaphragm element made of rubber or oil resistant synthetic composition.

Advantage Disadvantage Where it is necessary to prevent contact b/w liquid and diaphragm, the box may be installed in a well outside the tank and the well is communicated to the tank with an impulse piping. The impulse piping and the well are filled with an inert liquid. Disadvantage The main disadvantage is that the head developed is not sufficient to meet up the line losses as well as for a satisfactory indication. Hence ranges are quite limited.