Abstract In addition to continued testing for E. coli O157:H7, new regulations in the United States require industry to begin monitoring for six non-O157.

Slides:



Advertisements
Similar presentations
STABILITY OF SEEDED SWAB SPECIMENS FOR THE DETECTION OF CHLAMYDIA TRACHOMATIS IN THE GEN-PROBE APTIMA TEST J Schachter and J Moncada. University of California,
Advertisements

By Gracie Canales August 10, 2010
Detection and Enumeration of Food Pathogens with the BAX® PCR System Thomas P. Oscar, Ph.D. Research Food Technologist Welcome……thank you for coming!
Prevalence of Enterohemorrhagic E. coli (EHEC) Marler and Clark Retail Ground Beef Baseline Study: Phase 3.
Cat # SL Store at 4 0 C CompLysis™ Protein Extraction Reagent for Mammalian Cells Small 125 ml Large 500 ml Gaither Drive Gaithersburg, MD.
Validation of Microbiological Methods for Use in the Food Industry Brazilian Association for Food Protection 6 th International Symposium Sao Paulo, Brazil.
 Molecular Laboratory must have an ongoing Bio-safety SOP and also quality improvement program to monitor and evaluate objectively and systematically.
Amplification and Detection of Nucleic Acid by the Real-Time RT-PCR Procedure Janice C. Pedersen, Microbiologist Avian Section Diagnostic Virology Laboratory.
Practical #2: Extraction of genomic DNA from E.Coli Practical #3: Agarose Gel Electrophoresis Bertrand Ong Chan JianPeng Salanne Lee.
ASEPTIC TECHNIQUE Removing inoculum from a broth culture
Austin Brugger Grade 10 Pittsburgh Central Catholic High School.
Microbiology and Serology
Fitness Problems in Escherichia coli K-12 Transformed with a High Copy Plasmid Encoding the Green Fluorescent Protein Thomas P. Oscar a, Kalpana Dulal.
Emily Young Carr Grade 9 Academy of Notre Dame de Namur Levels of Pollutants in Local Waters.
COBAS AmpliPrep/Cobas TaqMan HIV-1 Test
QuantityMaterialSymbol 1Late Exponential phase culture of wildtype E. coli W3110, a K12 strain 3Tryptose Blood Agar Base plates (TBAB) 2TBAB plates containing.
Titles Good and Bad Titles. Below you will find an abstract from one of the Bio3B projects. Which of the following title would be most appropriate for.
Supplementary Materials and Methods Real-time RT-PCR Genomic DNA was isolated from washed cell pellets of eight biliary tract cancer cell lines (SNU-245,
EFFECTS OF FRACKING FLUID ON STAPH. EPIDERMIDIS AND E. COLI LUKE WEARDEN GRADE 11 CENTRAL CATHOLIC HIGH SCHOOL.
Design of E. coli O157:H7 sampling and testing programs by Industry
PCR method for detecting pathogens in food and environmental samples
Listeria monocytogenes survival in refrigerator dill pickles Jin Kyung Kim a, Elaine M. D'Sa b, Mark A. Harrison a, Judy A. Harrison b, and Elizabeth L.
Thomas P. Oscar, Ph.D. USDA, ARS
Development of a Rapid Detection Method for Waterborne E. coli O157:H7 M. J. Collins, R. M. Hoffman, B. T. Argue, J. H. Standridge WI State Laboratory.
IAFP’s 11 th European Symposium on Food Safety Cardiff, Wales April 2015 IAFP’s 11 th European Symposium on Food Safety Cardiff, Wales April.
BIOLOGY 3020 Fall 2008 “Keys of Corn” Project Plasmid isolation Genetic Diversity in corn. Lots of different types of corn are offered for sale at the.
Generation of Transcription Factor Constructs for Mammalian Transfection Leah Schumerth, Michael Farrell, and Winnifred Bryant Ph. D. Department of Biology.
Food Industry Perspective on Non-O157 STEC Jenny Scott Vice President, Food Safety Programs Grocery Manufacturers/Food Products Association.
Mapping the Distribution of Salmonella Contamination on the Chicken Carcass Thomas P. Oscar 1, Geoffrey K. Rutto 2, Jacquelyn B. Ludwig 1 and Salina Parveen.
Overview of the presentation 1.The LiMA technology 2.Sensitivity for ligase detection 3.Sensitivity for bacterial detection.
Bacterial Screening of Platelet Concentrates by Real-Time PCR Theo Cuypers 1 also on behalf of, H.W. Reesink 1,3 I.G.H. Rood 1,2 T. Mohammadi¹, ²P.H.M.
LAB 4: ASEPTIC TECHNIQUE AND ISOLATION OF BACTERIA
Julia Robbins August 11, Objectives Clinical Significance of MRSA in Healthcare Setting Principle of assay Assay Procedure Assay Perfomance.
HONEY ANTIMICROBIAL EFFECTS Alicia Grabiec Freeport Senior High School Grade 10.
P174: Enumeration of Salmonella with the Polymerase Chain Reaction BAX System and Simulation Modeling Thomas P. Oscar, Agricultural Research Service, USDA,
Isolation and Purification of DNA from Escherichia coli GROUP 2 Chester Mancia Frances Miclat Mark Mosses Oliva HUB 42.
Practical Part Microscopic Examination of Microorganisms Experiments Identification of MOs Different Staining Techniques.
Prevalence of Enterohemorrhagic E. coli (EHEC) in Marler and Clark Retail Ground Beef Baseline Study: Phase 3 Mansour Samadpour.
Richard A. Haugland USEPA, Office of Research and Development, National Exposure Research Laboratory Presented at ORD Product Expo for Region 9, February.
Non-O157 Shiga Toxin-producing E. coli: Status and Relevance to Food Safety The Food Safety Group U.S. Meat Animal Research Center USDA-ARS Clay Center,
Aquatic Thermal Tolerance of E.coli
Methods for detecting resistance Goal: To determine whether organism expresses resistances to agents potentially used for therapy Designed to determine.
Isolation of Bacteriophages
IN THE NAME OF ALLAH ALMIGHTY THE MOST COMPASSIONATE THE MERCIFUL.
Susceptibility (Sensitivity) Testing: Results Pharmaceutical Microbiology – Practical Course Semester One_ Sensitivity Results & MIC Broth Dilution/
Explaining the FSIS Sampling Program for Escherichia coli O157:H7 in Raw Ground Beef Kristina Barlow, Priya Kadam, Stephanie Buchanan, Priscilla Levine.
United States Department of Agriculture Food Safety and Inspection Service Overview of Trim Sampling Compliance Guidelines and Discussion Daniel Engeljohn,
USDA Public Meeting; Control of E. coli O157:H7
Investigating extracellular Enzymes of microorganisms.
Copyright © 2015 Beck, Eric T. Eric T. Beck 1, Garrett C. Reymann 1, Blake W. Buchan 1,2, and Nathan A. Ledeboer 1,2 1 Department.
CONCLUSIONS Amended Abstract Detection of GBS Directly from ESwab Collected Samples Using the BD MAX™ GBS Assay Suzane Silbert, Talita T. Rocchetti, Alicia.
Stool Culture, E. coli O157:H7
Rajan sharma.  Polymerase chain reaction Is a in vitro method of enzymatic synthesis of specific DNA sequences.  This method was first time developed.
United States Department of Agriculture Food Safety and Inspection Service Non-O157 STEC: What We Know and What’s Next Elisabeth Hagen, M.D. Office of.
D value – The time requires to inactivate 1 log scale (90%) of bacterial population at a particular temperature. Z value – The difference of temperature.
Identification of Genetically Modified Organisms in Foodstuffs.
Reduce volume mismatch between concentration and detection qPCR detection studies Modified Method 1611 Lyophilized reagents Isothermal (with lyophilized.
2. Centers for Disease Control and Prevention (CDC), Atlanta, GA, USA
Haemagglutination assay
D and Z values determination
2011 American Society for Microbiology Meeting
1Department of Esoteric Testing/R&D, Tampa General Hospital, Tampa, FL
Effect of Environmental Conditions on Listeria monocytogenes Attachment and Biofilm Development on Food Plant Surfaces. Angie Rubi1, Ilan Arvelo2, and.
Rainbow O157 Agar-Black colonies are E. coli O157
Bacterial Transformation Visual Guide
RESULTS AND DISCUSSION
Prevalence of Enterohemorrhagic E
D and Z values determination
Volume 8, Issue 20, Pages (October 1998)
Culture media Pure culture techniques & Bacterial colony
Presentation transcript:

Abstract In addition to continued testing for E. coli O157:H7, new regulations in the United States require industry to begin monitoring for six non-O157 Shiga toxin-producing E. coli (STEC) serogroups, referred to as the “top-six” non-O157 STEC (O26, O45, O103, O111, O121, and O145), as these have been most frequently associated with outbreaks and cases of food- borne illnesses in the U.S. These top six serogroups were recently declared as adulterants in beef by the USDA Food Safety and Inspection Service (FSIS), and testing for these serogroups in beef will begin in June, The purpose of this study was to conduct evaluations of three separate multiplex Scorpion probe-based PCR assays in a tableted format for the detection of the top-six STEC serogroups. The three multiplex assay configurations were as follows: Assay 1 – O26, O111, O121, and internal positive control (IPC); Assay 2 – O45, O103, O145, IPC; Assay 3 – eae, stx1/2, IPC. Studies evaluating the sensitivity of each of the real-time assays were conducted using titrations of cell lysates. Cell lysates were also used to conduct inclusivity and exclusivity studies for each assay configuration. Sensitivity of each assay with cell titers in tryptic soy broth for each of the various PCR targets was ≤ 1.0 X 10 4 CFU/mL. Each assay was 100% inclusive for the strains tested (n = per assay). Moreover, no cross- reactivity with closely related strains in any of the assays was observed. These results demonstrate the feasibility of deploying a panel of three novel real-time PCR assay configurations for the detection and monitoring of STEC O groups, as well as the virulence genes, eae, stx 1, and stx 2. The approach demonstrated could easily be expanded to include additional multiplex assays should regulations continue to expand into other O groups or virulence gene markers. Finally, the performance of the detection method based on use of the Scorpion probe-based multiplex PCR assays was compared to the FSIS Microbiology Laboratory Guidebook (MLG 5B.01) method for detection of the top-six STEC in beef. The performance of the multiplex Scorpion probe-based PCR assays (BAX® System) was similar to that of the USDA FSIS method for detecting non-O157 STEC in ground beef and beef trim. Development and Evaluation of Three Scorpion Probe-Based Multiplex Real- time PCR Assays for the Detection of Shiga Toxin-Producing Escherichia coli Serogroups O26, O45, O103, O111, O121, and O145 Pina M. Fratamico 1, Jamie L. Wasilenko 2, Daniel R. DeMarco 3, Stephen Varkey 3, Mark Jensen 3, Kyle Rhoden 3, and George Tice 3 1 USDA, Agricultural Research Service, Eastern Regional Research Center, Wyndmoor, Pennsylvania, U.S.A.; 2 USDA, Agricultural Research Service, Richard Russell Research Center, Athens, Georgia, U.S.A. 3 DuPont Qualicon E400, PO Box 80400, Wilmington, Delaware, U.S.A. Materials and Methods Strain Selection and Preparation The strains used in this study were obtained from a variety of sources, including the DuPont Qualicon culture collection, Michigan State University (Lansing, MI), USDA-ARS-ERRC (Wyndmoor, PA), USDA-Agricultural Marketing Service (AMS; Manassas, VA), and USDA-ARS-NPA MARC (Clay Center, NE). Each strain was grown in BHI at 37ºC overnight (about h) for testing with the BAX® System method as described below. For inclusivity and exclusivity testing, strains were tested at the USDA-ARS-ERRC and at DuPont Qualicon.Sensitivity Each overnight culture was diluted in TSB, and then 20 µL of the dilutions were transferred to a cluster tube with 200 µL prepared BAX® System lysis reagent (lysis buffer + protease). Lysis and protease inactivation were performed by heating samples at 37ºC for 20 min and 95ºC for 10 min, and then cooling at 4ºC for 5 min. PCR tablets were hydrated with 30 µL lysate and processed with the appropriate PCR assay. Positive/negative calls for the real-time PCR assay were made by visual observation of amplification curves. Inclusivity and Exclusivity For inclusivity testing, overnight cultures were diluted 1:10 in BHI, and then diluted to ~10 5 CFU/mL in TSB before transferring to tubes with prepared BAX® System lysis reagent. For exclusivity testing, overnight cultures were diluted 1:10 in BHI before transferring. Lysis, protease inactivation, and sample processing were performed for all inclusivity and exclusivity samples as described above. Positive/negative calls for the real time PCR assay were made by visual observation of amplification curves. Sample inoculation and preparation STEC top-six serogroup strains and E. coli O157:H7 were selected for these studies. An isolated colony of each strain was suspended in 8 mL of brain heart infusion (BHI) broth, incubated at 37˚C for h, and diluted in saline solution for inoculating samples. Ground beef and beef trim were divided into 325-g test portions, and 1 mL of the diluted test strain was added to each sample. Uninoculated samples served as negative controls. Samples were held at 4˚C for 2-3 days to stress the inoculum before enrichment. Sample enrichment Ground beef samples were homogenized with 1.5 L pre-warmed (42˚C) TSB with 2 mg/L novobiocin and incubated at 42˚C for 18 h before testing with the BAX® System. Trim samples were combined with 1.5 L pre-warmed (42˚C) TSB (without novobiocin) and incubated at 42˚C for 18 h before testing with the BAX® System. For the USDA method, all samples were homogenized with 975 mL room- temperature mTSB with 8 mg/L novobiocin, bile salts, and casamino acids, and then incubated at 42˚C for 18 h before testing with both the USDA and BAX® System methods. BAX ® System testing method Twenty microliters of enrichment were added to 200 µL prepared lysis reagent (150 µL protease and 12 mL lysis buffer). Lysis was performed by heating for 20 min at 37˚C and 10 min at 95˚C, then at 4˚C for at least 5 min. Thirty microliters of each lysate were used to hydrate a PCR tablet for the STEC Screening, STEC Panel 1, STEC Panel 2, and real-time E. coli O157:H7 assays. All PCR tubes were loaded into the BAX® System Q7 instrument. All samples were culture confirmed using the USDA confirmation method described below. USDA FSIS testing method DNA extraction was performed according to the FSIS MLG procedure 5B.01 (step 5B.6.1). PCR master mix was prepared as described in the MLG procedure 5B Appendix 1, then 20 µL master mix was mixed with 5 µL extracted DNA in the wells of the plate. The plate was centrifuged briefly, and then loaded into a real-time PCR cycler and processed to screen for stx and eae. Samples that returned positive results for both stx and eae were further processed using three multiplex real-time PCR reactions to identify the six target STEC serogroups, as described in MLG 5B.01. USDA FSIS confirmation method (all samples) Each sample enrichment was filtered using a sterile 40 µm cell strainer, and then 1 mL of the filtered enrichment was added to 20 µL O-specific immunomagnetic capture beads in a microcentrifuge tube. Enrichments were processed according to the protocol described in FSIS MLG procedure 5B.01. Discussion and Conclusions The results of these studies demonstrate that:  BAX® System performance was equivalent to or better than the USDA FSIS method for detecting non-O157 STEC in ground beef and beef trim.  The BAX® System accurately detected and identified the “top six” non-O157 STEC strains.  There was good sensitivity and inclusivity from the assays, as well as full exclusivity. P-058 Results The results for the first round of ground beef testing are summarized in Table1. All samples tested with the BAX® System returned the appropriate positive results for each assay. Three samples tested - those spiked with E. coli O111, O121 and O145 – also returned positive results that identified the presence E. coli O103. These samples were found to be naturally contaminated with an E. coli O103 strain, which caused the samples to return negative results during the pre-screen for virulence factors but positive results for the specific O group during the study. All BAX® System results correlated 100% with the results of the USDA PCR method. The results for the second and third rounds of ground beef testing are summarized in Tables 2 and 3. All samples tested with the BAX® System returned positive results for the Screening assay for stx and eae, and the Panel 1 and Panel 2 assays correctly identified each of the “top six” strains. All BAX® System results correlated 100% with the results of the USDA PCR method. The results for the first round of beef trim testing are summarized in Table 4. All samples tested with the BAX® System returned the appropriate positive results for each assay, and all BAX® System results correlated 100% with the results of the USDA PCR method. E. coli O45 was not tested is this round due to mislabeling of the strain selected for spiking, which caused samples to be spiked with E. coli O103 instead of E. coli O45. Because of this spiking error, these samples were removed from the study results. The results for the second round of beef trim testing are summarized in Table 5. All samples tested with the BAX® System returned positive results for both the Screening assay for stx and eae, and the Panel 1 and Panel 2 assays correctly identified each of the “top six” strains. In this round of testing, beef trim samples spiked with E. coli O111 and enriched with the USDA FSIS method failed to return positive results or culture confirm, while samples enriched with the BAX® System method were correctly detected. It is possible that these discrepant results were caused by the higher concentration of novobiocin in the reference method enrichment medium (8 mg/L compared to no novobiocin), which may have inhibited the growth of the target E. coli strain during enrichment. Table 6 shows the sensitivity of each assay with cell titers in TSB for each of the various PCR targets. These results demonstrate that for all organisms tested, the lower limit of detection was less than or equal to 1.2 X 10 3 CFU/mL. Table 7 shows a summary of the results from inclusivity testing. All of the strains tested were detected by the appropriate panel or screening assay. Table 8 shows a summary of the results from exclusivity testing. Neither of the panel assays nor the screening assay indicated any cross reactivity with the organisms tested. United States Department of Agriculture Agricultural Research Service