NEWS FROM MEDIPIX3 MEASUREMENTS AND IMPACT ON TIMEPIX2 X. Llopart CERN.

Slides:



Advertisements
Similar presentations
Specific requirements for analog electronics of a high counting rate TRD Vasile Catanescu NIHAM - Bucharest CBM 10th Collaboration Meeting Sept 25 – 28,
Advertisements

SKIROC New generation readout chip for ECAL M. Bouchel, J. Fleury, C. de La Taille, G. Martin-Chassard, L. Raux, IN2P3/LAL Orsay J. Lecoq, G. Bohner S.
1 Summary of WG5 MPGD related Electronics Wed. Oct. 15 th, 2008 Prepared by W. Riegler, presented (and interpreted) by H. Van der Graaf 2 nd RD51 Collaboration.
STATUS OF MEDIPIX-3, PLANS FOR TIMEPIX-2 X. Llopart.
Imaging Properties of the Medipix2 System exploiting Single and Dual Energy Thresholds L. Tlustos 1, R. Ballabriga 1, M. Campbell 1, E. Heijne 1, k Kincade.
MDT-ASD PRR C. Posch30-Aug-02 1 Specifications, Design and Performance   Specifications Functional Analog   Architecture Analog channel Programmable.
Mid-IR photon counting array using HgCdTe APDs and the Medipix2 ROIC
5ns Peaking Time Transimpedance Front End Amplifier for the Silicon Pixel Detector in the NA62 Gigatracker E. Martin a,b J. Kaplon b, A. Ceccucci b, P.
NA62 front end Layout in DM option Jan Kaplon/Pierre Jarron.
NA62 front end architecture and performance Jan Kaplon/Pierre Jarron.
Timepix2 power pulsing and future developments X. Llopart 17 th March 2011.
Power pulsing strategy with Timepix2 X. Llopart 10 th May 2011 Linear Collider Power Distribution and Pulsing workshop Timepix3.
Evaluation of 65nm technology for front-end electronics in HEP Pierpaolo Valerio 1 Pierpaolo Valerio -
MEDIPIX3 TESTING STATUS R. Ballabriga and X. Llopart.
Institute of Experimental and Applied Physics Czech Technical University in Prague 11th December 2007 Michal Platkevič RUIN Rapid Universal INterface for.
Mathieu Goffe EUDET JRA1 meeting, DESY Wednesday 30 January 2008 IPHC, 23 rue du Loess BP 28, 67037, Strasbourg Cedex 02, France.
Pierpaolo Valerio.  CLICpix is a hybrid pixel detector to be used as the CLIC vertex detector  Main features: ◦ small pixel pitch (25 μm), ◦ Simultaneous.
Second generation Front-end chip for H-Cal SiPM readout : SPIROC DESY Hamburg – le 13 février 2007 M. Bouchel, F. Dulucq, J. Fleury, C. de La Taille, G.
Silicon Sensor with Readout ASICs for EXAFS Spectroscopy Gianluigi De Geronimo, Paul O’Connor Microelectronics Group, Instrumentation Division, Brookhaven.
Readout ASIC for SiPM detector of the CTA new generation camera (ALPS) N.Fouque, R. Hermel, F. Mehrez, Sylvie Rosier-Lees LAPP (Laboratoire d’Annecy le.
A. Rivetti Gigatracker meeting, dec 2009 Charge measurement with the TDC per pixel architecture A. Rivetti, G. Dellacasa S. Garbolino, F. Marchetto, G.
*on behalf of the Medipx3, Timepix2 and VELOpix design teams
Phase-1 Design. i PHC Phase /04/2008 System Overview Clock, JTAG, sync marker and power supply connections Digital output.
The design of the TimePix chip Xavier Llopart, CERN MPI-Munich, October 2006.
Fully depleted MAPS: Pegasus and MIMOSA 33 Maciej Kachel, Wojciech Duliński PICSEL group, IPHC Strasbourg 1 For low energy X-ray applications.
Performance of a 128 Channel counting mode ASIC for direct X-ray imaging A 128 channel counting ASIC has been developed for direct X-ray imaging purposes.
Specifications & motivation 2  Lowering integration time would significantly reduce background  Lowering power would significantly reduce material budget.
Update on CLICpix design
DESIGN CONSIDERATIONS FOR CLICPIX2 AND STATUS REPORT ON THE TSV PROJECT Pierpaolo Valerio 1.
Pixel Readout Electronics - from HEP to imaging to HEP… Status, requirements, new ideas M. Campbell, R. Ballabriga, E. Heijne, X. Llopart, L. Tlustos,
Power Pulsing in Timepix3 X. Llopart CLIC Workshop, January
Valerio Re, Massimo Manghisoni Università di Bergamo and INFN, Pavia, Italy Jim Hoff, Abderrezak Mekkaoui, Raymond Yarema Fermi National Accelerator Laboratory.
65 nm CMOS analog front-end for pixel detectors at the HL-LHC
ClicPix ideas and a first specification draft P. Valerio.
Thanushan Kugathasan, CERN Plans on ALPIDE development 02/12/2014, CERN.
NSS-MIC 2009 Summary Rafael Ballabriga PH-ESE-ME.
TIMELINE FOR PRODUCTION 2  Need to be ready for production end next year  => submission of final mask set ~September 2015  Would like one more iteration.
LHCb Vertex Detector and Beetle Chip
Pixel detector development: sensor
CLICPIX AND MEDIPIX3-TSV PROJECTS Pierpaolo Valerio.
Progress with GaAs Pixel Detectors K.M.Smith University of Glasgow Acknowledgements: RD8 & RD19 (CERN Detector R.&D. collaboration) XIMAGE (Aixtron, I.M.C.,
S. Bota – Calorimeter Electronics overview - July 2002 Status of SPD electronics Very Front End Review of ASIC runs What’s new: RUN 4 and 5 Next Actions.
Aurore Savoy-Navarro 1), Albert Comerma 2), E. Deumens 3), Thanh Hung Pham 1), Rachid Sefri 1) 1) LPNHE-Université Pierre et Marie Curie/IN2P3-CNRS, Fr.
CERN PH MIC group P. Jarron 07 November 06 GIGATRACKER Meeting Gigatracker Front end based on ultra fast NINO circuit P. Jarron, G. Anelli, F. Anghinolfi,
CBM 12 th Meeting, October 14-18, 2008, Dubna Present status of the first version of NIHAM TRD-FEE analogic CHIP Vasile Catanescu and Mihai Petrovici NIHAM.
R. Kluit Nikhef Amsterdam R. Kluit Nikhef Amsterdam Gossopo3 3 rd Prototype of a front-end chip for 3D MPGD 1/27/20091GOSSIPPO3 prototype.
UPDATE ON CLICPIX2 DESIGN Pierpaolo Valerio Edinei Santin
K.Wyllie, CERNIWORID 2004 Readout of the LHCb pixel hybrid photon detectors Ken Wyllie on behalf of the LHCb collaboration and industrial partners The.
TIMEPIX2 FE STUDIES X. Llopart. Summary of work done During summer I have been looking at a possible front end for Timepix2 The baseline schematic is.
Timepix in EUDet – CERN contribution Michael Campbell PH Department CERN Geneva, Switzerland Spokesman, Medipix2 Collaboration.
Medipix3 chip, downscaled feature sizes, noise and timing resolution of the front-end Rafael Ballabriga 17 June 2010.
RD53 1.  Full/large demonstrator chip submission ◦ When: 2016 A.Early 2016: If chip must have been fully demonstrated in test beams for TDRs to be made.
Technical status of the Gossipo-3 : starting point for the design of the Timepix-2 March 10, Vladimir Gromov NIKHEF, Amsterdam, the Netherlands.
NOISE MEASUREMENTS ON CLICPIX AND FUTURE DEVELOPMENTS Pierpaolo Valerio.
Pixel structure in Timepix2 : practical limitations June 15, Vladimir Gromov NIKHEF, Amsterdam, the Netherlands.
H. Krüger, , DEPFET Workshop, Heidelberg1 System and DHP Development Module overview Data rates DHP function blocks Module layout Ideas & open questions.
ELACCO project update (Pixel ELECTRONICS for medipix)
e- and h+ (with leakage current compensation up to ~2nA/pixel)
Progress with GaAs Pixel Detectors
LHC1 & COOP September 1995 Report
CTA-LST meeting February 2015
STATUS OF SKIROC and ECAL FE PCB
BESIII EMC electronics
Silicon pixel detectors and electronics for hybrid photon detectors
OmegaPix 3D IC prototype for the ATLAS upgrade SLHC pixel project 3D Meeting 19th March, 2010 A. Lounis, C. de La Taille, N. Seguin-Moreau, G.
Readout Electronics for Pixel Sensors
A new family of pixel detectors for high frame rate X-ray applications Roberto Dinapoli†, Anna Bergamaschi, Beat Henrich, Roland Horisberger, Ian Johnson,
Readout Electronics for Pixel Sensors
Phase Frequency Detector &
Readout Electronics for Pixel Sensors
Presentation transcript:

NEWS FROM MEDIPIX3 MEASUREMENTS AND IMPACT ON TIMEPIX2 X. Llopart CERN

Outline Medipix3 introduction Chip description Electrical characterization summary Towards Medipix3 Si assemblies Conclusions Towards Timepix2

-3-Eudet Annual Meeting (19th October 2009)X. Llopart Medipix3 Introduction Medipix3 builds on the success of Medipix2 as a single photon counting imaging chip Added Features –Analogue charge summing to keep all charge information –Spectroscopic mode with 8 threshold levels –Continuous Count-Read mode (no dead time) –2 programmable depth binary counters (variable dynamic range) –Flexible readout scheme (ROI, configurable output port width) –Highly configurable Designed in a 130nm 8-metal CMOS technology Medipix3 introduction Chip description Electrical characterization summary Towards Medipix3 Si assemblies Conclusions Towards Timepix2

-4-Eudet Annual Meeting (19th October 2009)X. Llopart Medipix3 chip Pixel matrix of 256 x 256 pixels Bottom periphery contains: –LVDS drivers and receivers (500 Mbps) –Band-Gap and 25 DACs (10 9-bit and 15 8-bit) –32 e-fuse bits –EoC and 2 Test pulse generators per pixel column –Temperature sensor –Full IO logic and command decoder –Power/Ground pads –TSV landing pads –Pads extenders Top periphery contains: –Power/Ground pads –TSV landing pads –Pads extenders > 115 Million transistors Typical power consumption: –600 mW in Single pixel mode –900 mW in Charge summing mode 17.3 mm 14.1 mm Medipix3 introduction Chip description Electrical characterization summary Towards Medipix3 Si assemblies Conclusions Towards Timepix2

-5-Eudet Annual Meeting (19th October 2009)X. Llopart X [µm]Y [µm] Active Area Medipix2 and Timepix % Medipix3 top and bottom WB % Medipix3 bottom WB % Medipix3 top and bottom TVS % Medipix3 bottom TVS % 17.3 mm 14.1 mm Multiple dicing options 15.9 mm 15.3 mm 14.9 mm Medipix3 introduction Chip description Electrical characterization summary Towards Medipix3 Si assemblies Conclusions Towards Timepix2

-6-Eudet Annual Meeting (19th October 2009)X. Llopart Medipix3 pixel Modes Pixel Operation ModesPixel size# Thresholds Single Pixel Fine Pitch Mode → 55 µm x 55 µm 2 Charge Summing Colour Mode Spectroscopic Mode → 110 µm x 110 µm 8 Colour Mode with charge Summing Pixel Gain ModesLinearity# Thresholds High Gain Mode~10 ke - 2 Low Gain Mode ~20 ke - Pixel Counter ModesDynamic range# Counters 1-bit 12 4-bit bit bit Pixel Readout Modes# Active CountersDead Time Sequential Count-Read (SCR) 2Yes Continuous Count-Read (CCR)1No Medipix3 introduction Chip description Electrical characterization summary Towards Medipix3 Si assemblies Conclusions Towards Timepix2

-7-Eudet Annual Meeting (19th October 2009)X. Llopart Charge summing and allocation concept 55µm The winner takes all Medipix3 introduction Chip description Electrical characterization summary Towards Medipix3 Si assemblies Conclusions Towards Timepix2

-8-Eudet Annual Meeting (19th October 2009)X. Llopart Medipix3 Cell Schematic Medipix3 introduction Chip description Electrical characterization summary Towards Medipix3 Si assemblies Conclusions Towards Timepix2

-9-Eudet Annual Meeting (19th October 2009)X. Llopart Design fully exploits the 130 nm CMOS technology ~1600 transistors per pixel 1. Preamplifier 2. Shaper 3. Two discriminators with 5-bit threshold adjustment 4. Pixel memory (13-bits) 5. Arbitration logic for charge allocation 6. Control logic 7. Configurable counter Pixel Layout 55 µm Medipix3 introduction Chip description Electrical characterization summary Towards Medipix3 Si assemblies Conclusions Towards Timepix2

-10-Eudet Annual Meeting (19th October 2009)X. Llopart Electrical characterization Using the S-curve method the ENC, gain and threshold can be extracted ~690 e - σ rms ~60 e - Medipix3 introduction Chip description Electrical characterization summary Towards Medipix3 Si assemblies Conclusions Towards Timepix2

-11-Eudet Annual Meeting (19th October 2009)X. Llopart Full chip ENC distribution µ = 57.3 e - σ= 10.8 e - Single Pixel Mode µ = e - σ= 14.2 e - Charge Summing Mode (1/4 th of the pixel matrix) pixels Medipix3 introduction Chip description Electrical characterization summary Towards Medipix3 Si assemblies Conclusions Towards Timepix2

-12-Eudet Annual Meeting (19th October 2009)X. Llopart Measurement in charge summing ~3100 e - Medipix3 introduction Chip description Electrical characterization summary Towards Medipix3 Si assemblies Conclusions Towards Timepix2

-13-Eudet Annual Meeting (19th October 2009)X. Llopart Electrical pixel measurements summary These electrical measurements have to be validated once the first Medipix3 assemblies will be available Single Pixel ModeCharge Summing Mode CSA Gain11.4 mV/ke - CSA-Shapper Gain High Gain34 nA/ke - Low Gain20 nA/ke - Non-Linearity High Gain <5% up to 10 ke - Low Gain <5% up to 20 ke - Peaking timeHG / LG~110 ns Return to baseline High Gain<1.5 µs for 12 ke - Low Gain<2.5 µs for 25 ke - Electronic noise (unbonded) High Gain~60 e - rms ~130 e - rms Low Gain~85 e - rms ~180 e - rms Unadjusted Threshold spread High Gain~1000 e - rms ~1800 e - rms Low Gain~1900 e - rms ~3200 e - rms Expected Minimum threshold* High Gain~450 e - ~900 e - High Gain~650 e - ~1300 e - Pixel power consumptionHG / LG8 µW15 µW Medipix3 introduction Chip description Electrical characterization summary Towards Medipix3 Si assemblies Conclusions Towards Timepix2

-14-Eudet Annual Meeting (19th October 2009)X. Llopart 3 design flaws found 1)The incomplete modeling of the analog multiplexers leakage current at full chip scale: –2 DACs show shorter dynamic range output as expected –Temperature variations an increase induced radiation modifies the front-end bias operation point 2)The pixel input protection diode was not designed radiation hard: –The increase in leakage current degrades the analog performance of the pixel A new bias operation point of the pixel front-end has been found which allows more margin for bias voltages shifts 3)Incomplete mixed-signal modeling of a full custom logic block in the pixel counters: –Prevents the Continuous Count-Read mode to perform as designed. Medipix3 introduction Chip description Electrical characterization summary Towards Medipix3 Si assemblies Conclusions Towards Timepix2

-15-Eudet Annual Meeting (19th October 2009)X. Llopart Wafer Probing Summary Name#AABsCsDsEF# ChipsWhere VK7DG2H0 100 CERN/diced VT7DCWH CERN VT7DEVH Bump bonding VV7DFAH CERN VN7DE0H Bump bonding VU7DCVH CERN VW7DF9H CERN VQ7DCZH Bump bonding VS7DCXH CERN VU7DDCH CERN VL7DFJH CERN VW7DDAH CERN %15.1%3.9%31.5%7.4%2.5%100.0% Medipix3 introduction Chip description Electrical characterization summary Towards Medipix3 Si assemblies Conclusions Towards Timepix2

-16-Eudet Annual Meeting (19th October 2009)X. Llopart Best and worst wafer Medipix3 introduction Chip description Electrical characterization summary Towards Medipix3 Si assemblies Conclusions Towards Timepix2

-17-Eudet Annual Meeting (19th October 2009)X. Llopart First Medipix3 CERN First µm Si detectors bonded to single Medipix3 readout chips arrived at CERN this week end First assemblies will be mounted soon (today) and tested this week. First results to be presented next week in NSS-MIC09 (Orlando, USA) Images from Gädda Akiko (VTT, Finland) Medipix3 introduction Chip description Electrical characterization summary Towards Medipix3 Si assemblies Conclusions Towards Timepix2

-18-Eudet Annual Meeting (19th October 2009)X. Llopart Conclusions on Medipix3 The Medipix3 chip is the first last scale mixed mode chip built in 130nm CMOS technology in the High Energy Physics community The chip is highly configurable and it is prepared for 4-side butting with an active area of ~95% The inter-pixel architecture aimed to minimize the impact of charge sharing on energy resolution works Electrical characterization is completed and measurements show good agreement with the designed values. Yield results are reasonable given the chip size First Si assemblies will be available this week and will be used to confirm electrical measurements Medipix3 introduction Chip description Electrical characterization summary Towards Medipix3 Si assemblies Conclusions Towards Timepix2

-19-Eudet Annual Meeting (19th October 2009)X. Llopart Towards Timepix2 (I) Many building blocks used in Medipix3 can be reused for a new chip: –Band-Gap and DACs –E-fuses –LVDS drivers and receivers Our design team at CERN is currently studying some ideas for new pixel front-ends (preamplifier and discriminators) –improved TOT linearity –Temperature robustness –Minimize pixel to pixel gain variations Also a new PLL is being studied –Low power (<500  W) –Multiple output selection up to 100 MHz Medipix3 introduction Chip description Electrical characterization summary Towards Medipix3 Si assemblies Conclusions Towards Timepix2

-20-Eudet Annual Meeting (19th October 2009)X. Llopart Towards Timepix2 (II) In the Medipix3 collaboration there is a growing interest in Timepix2 This development will be funded by the Medipix3 Consortium Main specs: –Pixel to measure TOT and Arrival time information simultaneously –<2ns time resolution –Triggered readout –Sparse and very fast readout Medipix3 introduction Chip description Electrical characterization summary Towards Medipix3 Si assemblies Conclusions Towards Timepix2