 Sensor (S)–converts arbitary physical quantity into electric signal  Adaptor (A)–provides signal amplification to a required level; expands a dynamic.

Slides:



Advertisements
Similar presentations
Lecture 4: Signal Conditioning
Advertisements

Analog-to-Digital Converter (ADC) And
Sensors Interfacing.
ECE 353 Introduction to Microprocessor Systems Michael G. Morrow, P.E. Week 14.
Data Acquisition Risanuri Hidayat.
Data Acquisition Concepts Data Translation, Inc. Basics of Data Acquisition.
5/4/2006BAE Analog to Digital (A/D) Conversion An overview of A/D techniques.
Presented by- Md. Bashir Uddin Roll: Dept. of BME KUET, Khulna-9203.
Analog Sensing 101 WITH P Agenda  Analog Signal Characteristics  Common Problems with A/D Conversion  Clipping  Small Signals  Aliasing  Analog.
Op-amp Circuits and Active Filters
Lecture 9: D/A and A/D Converters
Interfacing Analog and Digital Circuits
Unit 4 Sensors and Actuators
Current-Mode Multi-Channel Integrating ADC Electrical Engineering and Computer Science Advisor: Dr. Benjamin J. Blalock Neena Nambiar 16 st April 2009.
Storey: Electrical & Electronic Systems © Pearson Education Limited 2004 OHT 26.1 Data Acquisition and Conversion  Introduction  Sampling  Signal Reconstruction.
Lecture 31 Electrical Instrumentation. Lecture 32 Electrical Instrumentation Electrical instrumentation is the process of acquiring data about one or.
ECE201 Lect-171 Capacitors (6.1); Inductors (6.2); LC Combinations (6.3) Dr. Holbert April 5, 2006.
Lecture161 Instrumentation Prof. Phillips March 14, 2003.
Chapter 1 - Introduction to Electronics Introduction Microelectronics Integrated Circuits (IC) Technology Silicon Chip Microcomputer / Microprocessor Discrete.
CMOS VLSIAnalog DesignSlide 1 CMOS VLSI Analog Design.
Lecture 101 Capacitors (5.1); Inductors (5.2); LC Combinations (5.3) Prof. Phillips March 7, 2003.
Operational Amplifiers in Chemical Instrumentation By Naaimat Muhammed.
Data Acquisition. Data Acquisition System Analog Signal Signal Conditioner ADC Digital Processing Communication.
Ch7 Operational Amplifiers and Op Amp Circuits
 The output from a single amplifier is generally insufficient to drive an output device. In other words, the gain of a single amplifier is inadequate.
Controlling Systems Using IT (Level 3) Lecture – 1030 Thursday 23/04/2015 Boston College (Rochford Campus)
ELECTRONICS PRIMER. Assignment: WEB-based Electronics Tutorial Basic definitions Components Ohm's Law LEDs and Transistors Additional electronics tutorials.
EKT314/4 Electronic Instrumentation
DATA ACQUISITION Today’s Topics Define DAQ and DAQ systems Signals (digital and analogue types) Transducers Signal Conditioning - Importance of grounding.
COMPONENTS REQUIRED STEP DOWN PRANSFORMER:
ACOE2551 Microprocessors Data Converters Analog to Digital Converters (ADC) –Convert an analog quantity (voltage, current) into a digital code Digital.
©2008 Pearson Education, Inc., Upper Saddle River, NJ. All rights reserved. This material is protected under all copyright laws as they currently exist.
Data Acquisition Systems
1 Passive components and circuits - CCP Lecture 4.
SIGMA-DELTA ADC SD16_A Sigma-Delta ADC Shruthi Sujendra.
ESE 232 Introduction to Electronic Circuits Professor Paul Min (314) Bryan Hall 302A.
ELECTRONIC INSTRUMENTATION & PLC DKT Signal Conditioning Circuits.
V. Rouillard  Introduction to measurement and statistical analysis DIGITAL SAMPLING - DIGITISATION Digital sampling is mainly used in data acquisition.
Fundamentals of Electric Circuits Chapter 5 Copyright © The McGraw-Hill Companies, Inc. Permission required for reproduction or display.
Lecture 4: Electrical Circuits
The ECG UConn BME 290. Buffers What is a buffer? –Non-inverting amplifier with a gain of 1 Why use a buffer? –Buffers provide a high input impedance.
Lecture 2: Filters.
Passive filters A frequency selective circuit, or filter, enables signals at certain frequencies to reach the output, and it attenuates (weaken or lessen.
Lecture 4: Signal Conditioning
Operational amplifier. Definition The operational amplifier is a linear device for general purpose that features the managing signals from f = 0 Hz to.
Variable-Frequency Response Analysis Network performance as function of frequency. Transfer function Sinusoidal Frequency Analysis Bode plots to display.
2/June/2009LHCb Upgrade1 Single ended ADC Differential ADC –Convert single ended signal to differential (use AD8138 amp) –ASIC differential output ADC.
Op amp 2 Active Filters.
EKT 314/4 WEEK 2 : CHAPTER 1 INTRODUCTION TO EI ELECTRONIC INSTRUMENTATION.
EXAMPLE 2 – PHOTODIODE A photodiode is a semiconductor device that converts light into current. The current is generated when photons are absorbed in the.
EKT 314/4 WEEK 7 : CHAPTER 3 SIGNAL CONDITIONING ELECTRONIC INSTRUMENTATION.
CLOSED LOOP SPEED CONTROL OF DC MOTOR WITH PWM TECHNIQUE
Lecture Notes / PPT UNIT III
Sampling. Introduction  Sampling refers to the process of converting a continuous, analog signal to discrete digital numbers.
Ch7 Operational Amplifiers and Op Amp Circuits
MECH 373 Instrumentation and Measurements
Test! OpAmp Active Filters
MECH 373 Instrumentation and Measurements
(3) Signal Conditioning
(4) Filters.
B.Sc. Thesis by Çağrı Gürleyük
MECH 373 Instrumentation and Measurements
Block Diagram Transmitter Receiver × 2 Transmitter Power Supply ADC
Overview Communication is the transfer of information from one place to another. This should be done - as efficiently as possible - with as much fidelity/reliability.
Signal conditioning.
Operational Amplifiers in Chemical Instrumentation
Instrumentation & Measurement (ME342)
Digital Control Systems Waseem Gulsher
Fundamentals of Electric Circuits Chapter 5
Chapter 5: Active Filters
Presentation transcript:

 Sensor (S)–converts arbitary physical quantity into electric signal  Adaptor (A)–provides signal amplification to a required level; expands a dynamic range of input signal; sensor adjustment and other DCP channel elements according to the load.  Normalization circuit (NC)– is used as a filter, unwanted low-frequency and high frequency components are removed from the signal

 Functional conversion (FC) of analog signal is carried out in order to implement units in sensor structure to display definite mathematical operations and improve its accuracy parameters.  Sample and hold device(SHD) – is used to store analog signal for a transformation time period of ADC  Analog-to-digital converter (ADC) –transforms analog signal into a digital code

 Digital switch (DS) – selects a channel and transmits data to a microprocessor.  Microprocessor (MP) – on the one hand, it is a complex program-driven device, on the other hand, it is an enormous integrated circuit.

 Operational amplifier (OA) – is an analog integrated environment (IE), voltage is formed on its output, this voltage is equal to a gain difference between two input voltages.

OA is totally insensitive to any components of input signals common to both OA inputs. It is called a common- mode signal and is given by

Ideal frequency selective filter– a device or system which has a gain- transfer characteristic between input and output; it is constant in a certain frequency bandwidth and there is a naught output in a stopband. Advantages of an active filter compared with a passive filter :  Gain. The active filter with a maximum gain-transfer characteristic can be greater than unity.  Minimal load impact. A gain-transfer characteristic of an active filter is practically independent of the load the filter works for and a source that controls the filter.  Non-inductive filters. To design an active filter only resistors and capacitors are required, inductance is not required. This feature is particularly important when operating at relatively low frequencies (<10 Hz), otherwise it would require larger inductance.

 Comparator – a circuit that compares two input voltages U вх and U оп ; it generates output voltage Uo=Uh, if U вх ˃ U оп and Uo=Ul if U вх  U оп, where Uh и Ul - two fixed voltage levels (high and low).

 To store changing analog signals for the time of conversion, switching and other operations in data collection systems a sample and hold circuit is used