Andrey Sokolov Budker Institute of Nuclear Physics, Novosibirsk, Russia Novosibirsk State University, Russia Two-phase Cryogenic Avalanche Detectors March.

Slides:



Advertisements
Similar presentations
Advanced GAmma Tracking Array
Advertisements

NEST: Noble Element Simulation Technique Modeling the Underlying Physics of Noble Liquids, Gases Matthew Szydagis, UC Davis UCLA DM 02/28/14 1
First observation of electroluminescence in liquid xenon within THGEM holes: towards novel Liquid Hole-Multipliers L. Arazi, A. Breskin, A. Coimbra*,
Study of plastic scintillators for fast neutron measurements
Chapter 8 Planar Scintigaraphy
for Fusion Power Monitoring
1 Two-phase and gaseous cryogenic avalanche detectors based on GEMs A. Bondar, A. Buzulutskov, A. Grebenuk, D. Pavlyuchenko, R. Snopkov, Y. Tikhonov Budker.
Hiroyuki Sekiya Jul. 31 st 2008, Philadelphia, ICHEP2008 Development of Gaseous Photomultiplier with GEM/μPIC Hiroyuki Sekiya ICRR, University of Tokyo.
DMSAG 14/8/06 Mark Boulay Towards Dark Matter with DEAP at SNOLAB Mark Boulay Canada Research Chair in Particle Astrophysics Queen’s University DEAP-1:
Reflectivity Measurements of Critical Materials for the LUX Dark Matter Experiment Theory My experiment was a cyclic process involving software, engineering,
Dark Matter Searches with Dual-Phase Noble Liquid Detectors Imperial HEP 1st Year Talks ‒ Evidence and Motivation ‒ Dual-phase Noble Liquid Detectors ‒
The XENON Project A 1 tonne Liquid Xenon experiment for a sensitive Dark Matter Search Elena Aprile Columbia University.
Lecture 2-Building a Detector George K. Parks Space Sciences Laboratory UC Berkeley, Berkeley, CA.
Proportional Light in a Dual Phase Xenon Chamber
Xiaodong Wang ( 王晓冬 ) School of Nuclear Science and Technology Lanzhou University, Lanzhou, China MPGD activities at Lanzhou University July 5, 2013.
Photon detection Visible or near-visible wavelengths
The Transverse detector is made of an array of 256 scintillating fibers coupled to Avalanche PhotoDiodes (APD). The small size of the fibers (5X5mm) results.
I. Giomataris Large TPCs for low energy rare event detection NNN05 Next Generation of Nucleon Decay and Neutrino Detectors 7-9 April 2005 Aussois, Savoie,
DEVELOPMENT OF PHOTODETECTION SYSTEM BASED ON MULTIPIXEL AVALANCHE GEIGER PHOTODIODES WITH WLS FOR LXE LOW-BACKGROUND DETECTORS D.Yu. Akimov, A.V. Akindinov,
A. Lyashenko INSTR08 – BINP – Feb ION BLOCKING & visible-sensitive gas-PMs Efficient ion blocking in gaseous detectors and its application to visible-sensitive.
1 The GEM Readout Alternative for XENON Uwe Oberlack Rice University PMT Readout conversion to UV light and proportional multiplication conversion to charge.
CRESST Cryogenic Rare Event Search with Superconducting Thermometers Max-Planck-Institut für Physik University of Oxford Technische Universität München.
TAUP2007, Sendai, 12/09/2007 Vitaly Kudryavtsev 1 Limits on WIMP nuclear recoils from ZEPLIN-II data Vitaly A. Kudryavtsev Department of Physics and Astronomy.
Scintillation hodoscope with SiPM readout for the CLAS detector S. Stepanyan (JLAB) IEEE conference, Dresden, October 21, 2008.
LRT2004 Sudbury, December 2004Igor G. Irastorza, CEA Saclay NOSTOS: a spherical TPC to detect low energy neutrinos Igor G. Irastorza CEA/Saclay NOSTOS.
Neutron scattering systems for calibration of dark matter search and low-energy neutrino detectors A.Bondar, A.Buzulutskov, A.Burdakov, E.Grishnjaev, A.Dolgov,
Digital analysis of scintillator pulses generated by high-energy neutrons. Jan Novák, Mitja Majerle, Pavel Bém, Z. Matěj 1, František Cvachovec 2, 1 Faculty.
Large TPC Workshop, Paris, December 2004Igor G. Irastorza, CEA Saclay NOSTOS: a spherical TPC to detect low energy neutrinos Igor G. Irastorza CEA/Saclay.
Diego Gonzalez Diaz (Univ. Zaragoza and CERN)
Pyroelectric X-ray and neutron generator for low background detectors calibration A.S. Chepurnov a, V.Y. Ionidi a, O.O. Ivashchuk b, A.S. Kubankin b,c,
Alexei Buzulutskov Budker Institute of Nuclear Physics (Budker INP), Novosibirsk, Russia Novosibirsk State University (NSU), Novosibirsk, Russia Cryogenic.
I. Giomataris NOSTOS a new low energy neutrino experiment Detect low energy neutrinos from a tritium source using a spherical gaseous TPC Study neutrino.
RED-100 detector for the first observation of the elastic coherent neutrino scattering off xenon nuclei On behalf of the COHERENT collaboration Alexander.
Takeshi Fujiwara, Hiroyuki Takahashi, Kaoru Fujita, Naoko Iyomoto Department of Nuclear Engineering and Management, The University of Tokyo, JAPAN Study.
ZEPLIN I: First limits on nuclear recoil events Vitaly A. Kudryavtsev Department of Physics and Astronomy University of Sheffield, UK For the UK Dark Matter.
Prospects to Use Silicon Photomultipliers for the Astroparticle Physics Experiments EUSO and MAGIC A. Nepomuk Otte Max-Planck-Institut für Physik München.
1/27/2016Katsushi Arisaka 1 University of California, Los Angeles Department of Physics and Astronomy Katsushi Arisaka XAX 10.
Electron tracking Compton camera NASA/WMAP Science Team  -PIC We report on an improvement on data acquisition for a Time Projection Chamber (TPC) based.
1 Two-phase Ar avalanche detectors based on GEMs A. Bondar, A. Buzulutskov, A. Grebenuk, D. Pavlyuchenko, Y. Tikhonov Budker Institute of Nuclear Physics,
Collection of Photoelectrons from a CsI Photocathode in Triple GEM Detectors C. Woody B.Azmuon 1, A Caccavano 1, Z.Citron 2, M.Durham 2, T.Hemmick 2, J.Kamin.
T. Zerguerras- RD51 WG Meeting- CERN - February Single-electron response and energy resolution of a Micromegas detector T. Zerguerras *, B.
1 A two-phase Ar avalanche detector with CsI photocathode: first results A. Bondar, A. Buzulutskov, A. Grebenuk, D. Pavlyuchenko, R. Snopkov, Y. Tikhonov.
ZEPLIN III Position Sensitivity PSD7, 12 th to 17 th September 2005, Liverpool, UK Alexandre Lindote LIP - Coimbra, Portugal On behalf of the ZEPLIN/UKDM.
THGEMs: very recent results towards applications in DHCAL & LXe detector readout Weizmann: A. Breskin, R. Chechik, R. Budnik, CERN: V. Peskov Coimbra &
Detecting the Directionality of Dark Matter via “Columnar Recombination” (CR) Technique An attractive, natural candidate for Dark Matter is the WIMP –
Present status of production target and Room design Takashi Hashimoto, IBS/RISP 2015, February.
Upgrade of the MEG liquid xenon calorimeter with VUV-light sensitive large area SiPMs Kei Ieki for the MEG-II collaboration 1 II.
Forschungszentrum Karlsruhe Erice, 7th July th International School for Cosmic Rays Astrophysics Motivation Energy Reconstruction Air Fluorescence.
Results from the LUX experiment and presentation of LUX-ZEPLIN Timothy John Sumner Imperial College London on behalf of the LUX and LZ collaborations Belgian.
Development of UV-sensitive MPPC for upgrade of liquid xenon detector in MEG experiment Daisuke Kaneko, on behalf of the MEG Collaboration µ γ Liquid xenon.
Scintillating Bubble Chambers for Direct Dark Matter Detection Jeremy Mock On behalf of the UAlbany and Northwestern Groups 1.
Thorsten Lux. Charged particles X-ray (UV) Photons Cathode Anode Amplification Provides: xy position Energy (z position) e- CsI coating 2 Gas (Mixture)
Andrey Sokolov Novosibirsk State University (NSU) Budker Institute of Nuclear Physics (Budker INP) Novosibirsk, Russia Two-phase Cryogenic Avalanche Detector.
V.Aulchenko 1,2, L.Shekhtman 1,2, B.Tolochko 3,2, V.Zhulanov 1,2 Budker Institute of Nuclear Physics, , Novosibirsk, Russia Novosibirsk State University,
Study of the cryogenic THGEM-GPM for the readout of scintillation light from liquid argon Xie Wenqing( 谢文庆 ), Fu Yidong( 付逸冬 ), Li Yulan( 李玉兰 ) Department.
FARICH status E.A.Kravchenko Budker INP, Novosibirsk, Russia.
TPC for ILC and application to Fast Neutron Imaging L. An 2, D. Attié 1, Y. Chen 2, P. Colas 1, M. Riallot 1, H. Shen 2, W. Wang 1,2, X. Wang 2, C. Zhang.
Study of cryogenic photomultiplier tubes for the future double-phase cryogenic avalanche detector. Budker INP A.Bondar, A.Buzulutskov,A.Dolgov, E.Frolov,
Amos Breskin Weizmann Institute of Science
The Electromagnetic Calorimetry of the PANDA Detector at FAIR
Frontier Detectors for Frontier Physics
MPGD 2013 Conference,Zaragoza July 1-4, 2012
University of South Dakota
Upgrade of LXe gamma-ray detector in MEG experiment
C.Octavio Domínguez, Humberto Maury Cuna
BINP:Two-phase Cryogenic Avalanche Detector (CRAD) with EL gap and THGEM/GAPD-matrix multiplier: concept and experimental setup Concept: Detector of nuclear.
Gain measurements of Chromium GEM foils
E. Erdal(1), L. Arazi(2), A. Breskin(1), S. Shchemelinin(1), A
Presentation transcript:

Andrey Sokolov Budker Institute of Nuclear Physics, Novosibirsk, Russia Novosibirsk State University, Russia Two-phase Cryogenic Avalanche Detectors March 1, 2014

WIMP direct detection: two phase Xe WIMP, neutron S2/S1 Gamma >>S2/S1 WIMP Gamma Drift time Top PMT Array Bottom PMT Array A. Lyashenko XENON1T collaboration

Outline 3 1. CRyogenic Avalanche Detector concepts. 2. Our ongoing project on two-phase CRADs for dark matter search and low-energy neutrino detection. 3. Two-phase CRAD R&D results: - Two-phase CRADs with charge readout. - Two-phase CRADS with optical readout. 4. Results on two-phase Ar CRADs with THGEM/GAPD-matrix optical readout 5. Neutron scattering on Ar nuclei and quenching factor mesurement 5. Summary. Andrey Sokolov, INSTR14, March 1, 2014

CRAD concepts 4 - Final goal: development of detectors of ultimate sensitivity (single-electron mode, with high spatial resolution, at extremely low noise) for rare-event experiments and other (i.e. medical) applications. - Basic idea: combining hole-type MPGDs (GEMs and THGEMs) with cryogenic noble gas detectors, either in a gaseous, liquid or two-phase mode. - We call such detectors “CRyogenic Avalanche Detectors”: CRADs. This concept was further developed, in particular suggesting to provide CRADs with: - THGEM multiplier charge readout - MPGD-based Gaseous Photomultiplier (GPM) separated by window from noble liquid - CCD optical readout of GEM multiplier - Combined THGEM/GAPD multiplier optical readout (GAPD = Geiger-mode APD or SiPM) Andrey Sokolov, INSTR14, March 1, 2014

Outline 5 1. CRyogenic Avalanche Detector concepts. 2. Our ongoing project on two-phase CRADs for dark matter search and low-energy neutrino detection. 3. Two-phase CRAD R&D results: - Two-phase CRADs with charge readout. - Two-phase CRADS with optical readout. 4. Results on two-phase Ar CRADs with THGEM/GAPD-matrix optical readout 5. Neutron scattering on Ar nuclei and quenching factor mesurement 5. Summary. Andrey Sokolov, INSTR14, March 1, 2014

6 Our ongoing CRAD-related project 6 Accordingly, we need to develop high-gain, extremely-low-noise and self-triggered two-phase CRADs having single-electron sensitivity, for 3 experiment types: - Coherent Neutrino-Nucleus Scattering experiments; - Dark Matter search experiments; - low-energy nuclear-recoil calibration experiments. Andrey Sokolov, INSTR14, March 1, 2014

CRAD laboratory 7 Andrey Sokolov, INSTR14, March 1, 2014

CRAD prototype liters cryogenic chamber with 5cm-diameter Al X-ray windows - ~ liters of liquid Ar or Xe - THGEM or THGEM/GAPD assembly inside - Purification using Oxisorb : 20 µs e lifetime - 1-day cooling cycle hours liquid Ar collection time Andrey Sokolov, INSTR14, March 1, 2014

Outline 9 1. CRyogenic Avalanche Detector concepts. 2. Our ongoing project on two-phase CRADs for dark matter search and low-energy neutrino detection. 3. Two-phase CRAD R&D results: - Two-phase CRADs with charge readout. - Two-phase CRADS with optical readout. 4. Results on two-phase Ar CRADs with THGEM/GAPD-matrix optical readout 5. Neutron scattering on Ar nuclei and quenching factor mesurement 5. Summary. Andrey Sokolov, INSTR14, March 1, 2014

Two-phase CRADs in Ar with THGEM and hybrid THGEM/GEM multiplier (10×10 cm 2 active area) or 5 cm thick LAr layer - Electron life time in LAr ~ 13  s - THGEM geometry: p/d/h=0.9/0.5/1 mm [NSU & Budker INP: A.Bondar et al, JINST 8 (2013) P02008]

Two-phase CRAD in Ar with THGEM and hybrid THGEM/GEM multiplier 11 - Confirmed proper performance at high gains of two-phase Ar CRADs having practical size (10x10 cm2 active area and 1-5cm thick liquid layer) - Gains reached 1000 with the 10x10cm2 double-THGEM multiplier [NSU & Budker INP: A.Bondar et al, JINST 8 (2013) P02008] - Higher gains, of about 5000, have been attained in two-phase Ar CRADs with a hybrid triple- stage multiplier, comprising of a double-THGEM followed by a GEM (in 2THGEM/GEM/PCB readout mode, i.e. with patterned anode)

CRAD energy threshold keV Energy threshold of CRAD can be measured using 241 Am source with 60 keV photons. From the distribution threshold can be estimated as 11 keV±2 keV.

Concluding remarks to this section 13 Our general conclusion is that the maximum gains achieved in two-phase CRADs, of the order of in Ar and 500 in Xe, might be sufficient for Giant LAr TPC and PET applications. This however might not be sufficient for efficient single- electron counting, recording avalanche-charge in self- triggering mode (requiring gain values of 20,000-30,000). Accordingly, ways of increasing the overall gain should be looked for. A possible solution is the optical readout of THGEM avalanches using Geiger Mode APDs (GAPDs); it is considered in the following. Andrey Sokolov, INSTR14, March 1, 2014

Outline CRyogenic Avalanche Detector concepts. 2. Our ongoing project on two-phase CRADs for dark matter search and low-energy neutrino detection. 3. Two-phase CRAD R&D results: - Two-phase CRADs with charge readout. - Two-phase CRADS with optical readout. 4. Results on two-phase Ar CRADs with THGEM/GAPD-matrix optical readout 5. Neutron scattering on Ar nuclei and quenching factor mesurement 5. Summary. Andrey Sokolov, INSTR14, March 1, 2014

15 Noble gases have intense secondary scintillations both in VUV and NIR, while GAPDs have high quantum efficiency in the visible and NIR region. This results in two concepts of THGEM optical readout: - using WLS-coated GAPD sensitive to the VUV; - using uncoated GAPD sensitive to the NIR. Optical readout of CRADs with combined THGEM/GAPD multiplier: motivation 15 - Visible and NIR emission spectra of gaseous Ar and Xe and liquid Ar - GAPD PDE [A.Buzulutskov, JINST 7 (2012) C02025]

16 GAPD bipolar GAPD unipolar THGEM [Budker INP, ITEP, Weizmann Inst: A.Bondar et al, JINST 5 (2010) P08002; JINST 6 (2011) P07008] Combined multiplier yield = = 700 pe per 60 keV X-ray at THGEM gain=400, i.e 12 pe/keV at this particular solid angle (±12mm field of view at a distance of 5 mm) Avalanche scintillations from THGEMs holes have been observed in the NIR using uncoated GAPDs. 16 Two-phase Ar CRADs with THGEM/GAPD optical readout in the NIR: combined multiplier yield 16

NIR scintillations in gaseous and liquid Ar: primary and secondary scintillation yield 17 Primary scintillation yield in the NIR has been measured: - In gaseous Ar it amounted to 17000± 3000 photon/MeV in 690–1000 nm - In liquid Ar it amounted to 510±90 photon/MeV in 400–1000 nm [Budker INP: A.Buzulutskov et al, EPL 94 (2011) 52001; A. Bondar et al. JINST 7 (2012) P06014] - In GAr: secondary scintillations (electroluminescence) in the NIR were observed; fair agreement with simulation by [C.A.B.Oliveira et al., NIMA A722 (2013) 1] - In LAr: no secondary scintillations in the NIR were observed up to 30 kV/cm

Outline CRyogenic Avalanche Detector concepts. 2. Our ongoing project on two-phase CRADs for dark matter search and low-energy neutrino detection. 3. Two-phase CRAD R&D results: - Two-phase CRADs with charge readout. - Two-phase CRADS with optical readout. 4. Results on two-phase Ar CRADs with THGEM/GAPD-matrix optical readout 5. Neutron scattering on Ar nuclei and quenching factor mesurement 5. Summary. Andrey Sokolov, INSTR14, March 1, 2014

Two-phase Ar CRAD with THGEM/GAPD-matrix optical readout in the NIR: experimental setup A. Sokolov, MPGD2013, 3 July Double-THGEM multiplier in the gas phase - 3x3 GAPD matrix (1 cm spacing) optical readout in the NIR - Each GAPD (CPTA ) having 2x2 mm2 active area - 9 fast amplifiers (CPTA) outside the chamber - Irradiated with pulsed X-rays (~20 keV, 240Hz) through a 2mm diameter collimator, to estimate spatial resolution - Operated in single X-ray photon counting mode 1 cm

Two-phase Ar CRAD with THGEM/GAPD-matrix optical readout in the NIR: experimental setup 20 - Irradiated with pulsed X-rays (~20 keV, 240Hz) through a 2mm diameter collimator, to estimate spatial resolution - Operated in single X-ray photon counting mode Andrey Sokolov, INSTR14, March 1, 2014

The problem of gain saturation at higher rates for CPTA GAPDs 21 - However, at higher rates (240Hz) and intense photon flux the single pixel pulse-area spectrum was degraded  Saturation and even reduction of the GAPD gain -This is induced by considerable increase of the pixel quenching resistor at low T The infrequent nose signals had a nominal GAPD pulse-area distribution: single-pixel peak is accompanied with secondary (cross- talk) peaks

GAPD signal example and time properties A. Sokolov, MPGD2013, 3 July Typical GAPD signal: ~20 pe per 20 keV X-ray - Long (>16  s) signal due to slow electron emission component presented in two-phase Ar systems  see signal time spectrum - Measuring GAPD amplitude: counting the number of peaks using dedicated peak-finder algorithm - Part of signal is lost under threshold due to GAPD rate-dependence problem  reduces the GAPD pe yield

GAPD-matrix yield 23 - Correlation between GAPD channel amplitudes - Total GAPD-matrix (7 active channels) amplitude: 80 pe per 20 keV X-ray, at charge gain of That means that we may still have reasonable GAPD matrix yield for low energy deposition: >10 pe per 1 keV at charge gain of Higher yield is expected when the GAPD rate problem will be solved

Two-phase Ar CRAD with THGEM/GAPD- matrix multiplier: spatial resolution 24 - Reconstructed image of X-ray conversion region (defined by 2 and 15 mm collimators) from GAPD-matrix amplitudes - Using center-of-gravity algorithm corrected for simulation of light rays gives FWHM=3 mm  spatial resolution of THGEM/GAPD-matrix is 1 mm (  ). - Spatial resolution of THGEM/GAPD-matrix readout is far superior compared to that of PMT-matrix: of the order of 1 mm, for deposited energy of 20 keV at charge gain of 160. Our latest results on two-phase Ar CRAD with THGEM/GAPD-matrix optical readout: NSU & Budker INP: A.Bondar et al, arXiv: ] Andrey Sokolov, INSTR14, March 1, 2014

Selecting GAPD type 25 Hamamatsu MPPCs (3x3mm), CPTA MRS APDs (2.1x2.1 mm) and Sensl SiPM (3x3mm): before and after cryogenic runs  All those with ceramic package were cracked: should be avoided  GAPDs with plastic package should be used in cryogenic environment  Our choice for the future is Hamamatsu S P (3x3 mm) Before test After test Andrey Sokolov, INSTR14, March 1, 2014

Outline CRyogenic Avalanche Detector concepts. 2. Our ongoing project on two-phase CRADs for dark matter search and low-energy neutrino detection. 3. Two-phase CRAD R&D results: - Two-phase CRADs with charge readout. - Two-phase CRADS with optical readout. 4. Results on two-phase Ar CRADs with THGEM/GAPD-matrix optical readout 5. Neutron scattering on Ar nuclei and quenching factor mesurement 5. Summary. Andrey Sokolov, INSTR14, March 1, 2014

27 WIMP Search Technology Zoo Heat & Ionisation Bolometers Targets: Ge,Si CDMS, EDELWEISS cryogenic (<50 mK) Light & Heat Bolometers Targets: CaWO 4, BGO, Al 2 O 3 CRESST, ROSEBUD cryogenic (<50 mK) Light & Ionisation Detectors Targets: Xe, Ar ArDM, LUX, WARP, XENON, ZEPLIN cold (LN 2 ) H phonons ionisation Q L scintillation Scintillators Targets: NaI, Xe, Ar ANAIS, CLEAN, DAMA, DEAP, KIMS, LIBRA, NAIAD, XMASS, ZEPLIN-I Ionisation Detectors Targets: Ge, Si, CS 2, CdTe CoGeNT, DRIFT, DM-TPC GENIUS, HDMS, IGEX, NEWAGE Bolometers Targets: Ge, Si, Al 2 O 3, TeO 2 CRESST-I, CUORE, CUORICINO Bubbles & Droplets CF 3 Br, CF 3 I, C 3 F 8, C 4 F 10 COUPP, PICASSO, SIMPLE (credit H.Araújo) V. Chepel Dark Matter, Dark Energy and their Detection, Novosibirsk, 25 July 2013

28 Nuclear recoil data in LAr 28 Scintillation quenching factor: LAr, experiment [Gastler et al. Phys. Rev. C 85, (2012); C. Regenfus et al. J. Phys. Conf. Series 375 (2012) ] Total quenching factor for both ionization and excitation: LAr, theory [C. Hagmann, A. Bernstein IEEE Trans. Nucl. Sci. 51 (2004) 2151] Andrey Sokolov, INSTR14, March 1, 2014

29 Two neutron scattering systems are being developed by Plasma Physics Division teams: - DD generator (tube) of monochromatic 2.45 MeV neutrons + neutron counters [A. Burdakov, S. Polosatkin, E. Grishnyaev] D-D neutron scattering systems 29 [A. Bondar et al., Proposal for neutron scattering systems for calibration of dark matter search and low-energy neutrino detectors, in preparation] Andrey Sokolov, INSTR14, March 1, 2014

Neutron scattering system 30 CRAD cryostat Neutron source Neutron detector Andrey Sokolov, INSTR14, March 1, 2014

Neutron scattering spectrum 31 Andrey Sokolov, INSTR14, March 1, 2014 From the comparison the experimental and theoretical distributions one can conclude that ionization quenching factor equal 0,39±0.05 for the 330 keV recoil energy and 0,33±0.11 for the 75 keV.

Two-phase CRAD in Ar with THGEM/GAPD-matrix optical readout 32 - Cryogenic chamber with 50 cm electron drift and 50 l active volume (70 kg of active LAr and 200 kg in total) bottom and 20 side PMTs provide single-, double-, etc.- electron trigger for primary ionization. - The EL gap, having a thickness of 4 cm, matches with the size of the side PMT. - The total number of photoelectrons recorded by both PMT arrangements will be 23 pe. This is enough to make a selection between single- and double-electron events. - Avalanche scintillations produced in the holes of the second THGEM are recorded in the NIR using a matrix of GAPDs: this will provide a high (sub-cm) spatial resolution. [NSU & Budker INP: A. Bondar et al. JINST 7 (2012) P06014]

BNCT neutron facility at BINP 33 Andrey Sokolov, INSTR14, March 1, 2014 BNCT neutron facility consist of the tandem proton accelerator for 2 GeV and lithium target. It produce neutrons using 7 Li(p,n) 7 Be threshold reaction. At the beam current 10 mA the neutron production rate will be s -1. The neutron kinetic energy can be changed between 30 and 700 keV.

Li(p,n) 7 Be monochromatic neutron beam (of 77 keV energy) using 2MeV proton accelerator and 7 Li target [S. Taskaev et al.]. Neutron scattering systems 34 [A. Makarov, S. Taskaev, Pisma v JETF 97 (2013) 769] Andrey Sokolov, INSTR14, March 1, 2014

Summary A. Sokolov, MPGD2013, 3 July The idea of Cryogenic Avalanche Detectors (CRADs) had triggered intense and difficult R&D work in the course of last 10 years. This resulted in a variety of amazing CRAD concepts; for the time being the most intensively studied concepts are: - two-phase CRADs with THGEM multiplier readout; -optical readout of CRADs with combined THGEM/GAPD-matrix multipliers. Two-phase CRAD in Ar with THGEM/GAPD-matrix multiplier optical readout in the NIR showed excellent performance, namely high sensitivity (>100 pe per 20 keV at charge gain of ~100) and superior spatial resolution (~1 mm). Such kinds of CRADs may come to be in great demand in rare-event experiments, such as those of Coherent Neutrino-Nucleus Scattering, Dark Matter Search and Giant LAr TPCs for (astrophysical) neutrino physics, as well as in medical imaging fields (e.g. PET).

Summary 36 The ionization quenching factor equals 0,33±0.11 and 0,39±0.05 for the 75 and 330 keV nuclear recoil, correspondingly. The new layout of the CRAD detector is suggested for the precise measurement of the ionization quenching factor. Andrey Sokolov, INSTR14, March 1, 2014

Budker INP and NSU teams of CRAD laboratory 37 CRAD lab location: Budker INP. CRAD lab is operated in the frame of Budker INP and NSU research programs. Laboratory of Cosmology and Elementary Particles (NSU) and Cryogenic Avalanche Detectors “Laboratory” (Budker INP): A. Dolgov (head of the lab). Experimental group: A. Bondar, R. Belousov, A. Buzulutskov (coordinator), A. Chegodaev, A. Grebenuk, S. Peleganchuk, L. Shekhtman, E. Shemyakina, R. Snopkov, A. Sokolov We collaborate with two teams from Plasma Division of Budker INP on neutron scattering systems development: A. Burdakov, S. Polosatkin and E. Grishnyaev and S. Taskaev et al. We also collaborate on CRAD R&D with A. Breskin (Weizmann Inst.) and D. Thers (Nantes Univ.), in the frame of RD51 collaboration. This work supported in parts by Ministery of Science an Education of RF (grant 11.G ) and Russian Foundation for Basic Research ( CERN_a and ofi_m)

Two-phase Ar CRAD with THGEM/GAPD- matrix multiplier: data acquisition 38 8 readout channels using fast flash ADC CAEN V1720 (250 MHz)

Two-phase CRAD: some elements of PMT, cryogenic, vacuum, DAQ, GAPD and electronics systems 39