Andy Boston Imaging devices for medicine and security.

Slides:



Advertisements
Similar presentations
Topic 8. Gamma Camera (II)
Advertisements

Instruments for Radiation Detection and Measurement Lab # 4.
Applications of Nuclear Physics Applications of Nuclear Physics (Instrumentation) Dr Andy Boston Frontiers of gamma-ray spectroscopy.
M. JONES 1, A.J. Boston 1, H.C. Boston 1, R.J. Cooper 1, M.R. Dimmock 1, L.J. Harkness 1 D.S. Judson 1 P.J. Nolan 1, D.C. Oxley 1, B. Pietras 1 M.J. Joyce.
D S Judson UNTF Forum Salford. Outline The Compton imaging process The PORGAMRAYS project What is it? How does it work? Detector description Spectroscopic.
Advanced GAmma Tracking Array
PET Design: Simulation Studies using GEANT4 and GATE - Status Report - Martin Göttlich DESY.
Chapter 8 Planar Scintigaraphy
Buxton & District Science Discussion Medical Scanners Marge Rose 16 th November 2012.
Semiconductor detectors for Compton imaging in nuclear medicine
SmartPET: A Small Animal PET Demonstrator using HyperPure germanium Planar Detectors R. Cooper 1 st year PhD Student
Current Topics in Medical Physics Research Xiaoming Zheng, PhD. School of Dentistry and Health Science Chengdu, China, 2009.
Medical Imaging Mohammad Dawood Department of Computer Science University of Münster Germany.
Medical Imaging Mohammad Dawood Department of Computer Science University of Münster Germany.
Gamma Camera Technology
Topics in Medical Physics Xiaoming Zheng, PhD. School of Dentistry and Health Sciences December 2009, Chengdu.
Signal Processing of Germanium Detector Signals
Compton Identification Within Single ‘Pixels’ D. Scraggs, A. Boston, H. Boston, R. Cooper, J. Cresswell, A. Grint, A. Mather, P. Nolan University of Liverpool.
Signal Analysis and Processing David Scraggs. Overview Introduction to Position Resolution Induced Charges Wavelet Transform Future Work Discussion.
1 Current Compton Imaging Effort for Homeland Security at LLNL Address one of the outstanding problems for Homeland Security: “Faint” sources in the midst.
Signal Analysis and Processing for SmartPET D. Scraggs, A. Boston, H Boston, R Cooper, A Mather, G Turk University of Liverpool C. Hall, I. Lazarus Daresbury.
Simulations with MEGAlib Jau-Shian Liang Department of Physics, NTHU / SSL, UCB 2007/05/15.
Anthony Sweeney Position Sensitive Detectors 9 Aberystwyth 2011.
Lecture 2-Building a Detector George K. Parks Space Sciences Laboratory UC Berkeley, Berkeley, CA.
Instruments for Radiation Detection and Measurement
Planar scintigraphy produces two-dimensional images of three dimensional objects. It is handicapped by the superposition of active and nonactive layers.
Wednesday, May 9 th 2007Torsten Beck Fast Pulse Shape Analysis for AGATA-Germanium- Detectors Torsten BeckWednesday, 9. Mai 2007 Student seminar Wednesday,
Compton Camera development for the imaging of high energy gamma rays 1 Martin Jones UNTF 2010 Salford – April 14 th Martin.
Innovation is in our genes. 1 Siemens Medical Solutions Molecular Imaging What are SPECT basics?
SPECT imaging with semiconductor detectors
Fundamental Limits of Positron Emission Tomography
Medical Image Analysis Dr. Mohammad Dawood Department of Computer Science University of Münster Germany.
Wolfram KORTEN, JRA-02 AGATAEURONS PCC-Meeting, Mainz (Germany), April 2006 Status of the AGATA project Recent developments Milestones and deliverables.
First Results from a Test Bench for Very High Resolution Small Animal PET Using Solid-State Detectors Klaus Honscheid for The CIMA Collaboration The Ohio.
BMI I FS05 – Class 4 “Nuclear Imaging: Math” Slide 1 Biomedical Imaging I Class 5 – Radionuclide Imaging (PET, SPECT), Part 3: Attenuation and Scatter.
Professor Brian F Hutton Institute of Nuclear Medicine University College London Emission Tomography Principles and Reconstruction.
Nuclear Medicine: Tomographic Imaging – SPECT, SPECT-CT and PET-CT Katrina Cockburn Nuclear Medicine Physicist.
16. January 2007Status Report On Compton Imaging Projects 1 Status Of Compton Imaging Projects Carried Out In The CIMA Collaboration HPD Brain PET Meeting.
Development of a Segmented Planar Germanium Imaging Detector
Nuclear Medicine Principles & Technology_I
Medical applications of particle physics General characteristics of detectors (5 th Chapter) ASLI YILDIRIM.
Tracking Background GRETINA Software Working Group Meeting September 21-22, 2012, NSCL MSU I-Yang Lee Lawrence Berkeley National Laboratory.
Compton imaging with the PorGamRays Detector D S Judson Imaging 2010, Stockholm, 8 th -11 th June 2010.
1 Nuclear Medicine SPECT and PET. 2 a good book! SR Cherry, JA Sorenson, ME Phelps Physics in Nuclear Medicine Saunders, 2012.
Lecture 12  Last Week Summary  Sources of Image Degradation  Quality Control  The Sinogram  Introduction to Image Processing.
Acquisition time6 min1 min 12 s Collimator height25 mm (Anger)12 mm (HiSens) Detector1 layer, 1 pixel / hole3 layers, 1 pixel / hole3 layers, 4 pixels.
Steven Moon, A.J. Boston, H. Boston, J. Cresswell, L. Harkness, D. Judson, P.J. Nolan PSD9, Aberystwyth, Wales th September 2011 Compton imaging.
PGRIS: Towards portable Compton Camera Imaging
Nuclear Medicine Physics and Equipment 243 RAD 1 Dr. Abdo Mansour Assistant Professor of radiology
Nuclear Medicine Instrumentation 242 NMT 1 Dr. Abdo Mansour Assistant Professor of radiology
Room-Temperature Semiconductors: From concepts to applications Zhong He Nuclear Engineering and Radiological Sciences Department The University of Michigan,
Chapter-2 The Planar Imaging Important points in chapter 2 (chapter 13 from the book) The gamma camera (the basic principles of the gamma camera) The types.
PET Imaging Positron Emission Tomography
Simulations in Medical Physics Y. TOUFIQUE*, R.CHERKAOUI EL MOURSLI*, M.KACI**, G.AMOROS**, *Université Mohammed V –Agdal, Faculté des Sciences de Rabat,
Advanced Gamma Tracking Array Andy Boston The Advanced Gamma Tracking Array
Chapter-5 Positron emission tomography (PET)
Characterisation of a pixellated CsI detector for the Distinguish Project. 1 Martin Jones The University of Liverpool
AGATA Advanced Gamma Tracking Array
Development of a Compton Camera for online range monitoring
Thomas Woodroof Dr Jonathan Bridge, School of Engineering
Image quality and Performance Characteristics
SIGMA: a detector for γ-ray spectroscopy & imaging Dr Laura AGATA/GRETINA Collaboration Meeting
Function and Structure in
Chapter 8: Generic performance measures
Application of Nuclear Physics
Preliminary Compton Imaging results of the AGATA C001 detector
Function and Structure in
First demonstration of portable Compton camera to visualize 223-Ra concentration for radionuclide therapy Kazuya Fujieda (Waseda University) J. Kataoka,
Assist. Prof. Dr. Ilker Ozsahin Oct
Past / Future in Scintillation
Presentation transcript:

Andy Boston Imaging devices for medicine and security

Outline of presentation Focus on ionising radiation and gamma- rays –What are the challenges? –What detector technology can we consider? –Select example projects & links to fundamental research –The future prospects

KNOWLEDGE EXCHANGE Scientific Research Applications e.g. AGATA Gamma-ray Tracking Imaging Medical Security Environment

What are the challenges? In Nuclear Medicine: –Know the energy –Want the location over a small field of view –Need to cope with high count rates –Multimodality applications (eg PET/CT) –Image fusion

What are the challenges? In Nuclear Security : –Don’t know the energy & a broad range –Want the location over a large field of view –Need to cope with wide range of count rates –Image fusion

What are the detector requirements? Ideally would want: –Good energy resolution (Good light yield/charge collection) < few % –High efficiency (High Z) –Position resolution –Timing resolution Detector materials: –Semiconductors (Si, Ge, CdZnTe) –Scintillators (LaBr 3, CsI(Tl), NaI(Tl), BaFl, BGO, LYSO…)

What are the detector requirements? Need to know the location of the radiation: –Use a mechanical collimator (Anger Camera) –Use positron annihilation for LoRs –Use other electronic collimation Range of energies: –Medical 141 keV – 511 keV –Security 60 keV – 2 MeV Operating environment: –B-fields? Microphonics? High temperature?

Medical Imaging Focus on SPECT How it works and the opportunities

What is SPECT? Functional imaging modality 8 mSv typical dose

What SPECT Radionuclides? 141 keV t 1/2 =65.94h 2.1  10 5 y t 1/2 =6.01h >99% 9  % stable

Tomographic Imaging The sinogram is what we aim to measure - Measure of intensity as a function of projection, θ and position, r - Often seen plotted as a 2d grey scale image Underlying source distribution “Shepp-Logan Phantom” Measured result – “Sinogram” (256 projections, 363 positions per projection) Note : We measure from 0 to 180° θ r p(r, θ) x y f(x,y)

SPECT : Problems/Opportunities Technical Collimator Limits Spatial Resolution & Efficiency Collimator is heavy and bulky Energy of radioisotope limited to low energy NaI:Tl Dominant for >40 Years... MRI  Existing PMTs will not easily operate Would like to be able to image a larger fraction of events. Common radionuclides: 99m Tc, 123 I, 131 I

ProSPECTus Next generation Single Photon Emission Computed Tomography Nuclear Physics Group, Dept of Physics, University of Liverpool, Nuclear Physics & Technology Groups, STFC Daresbury Laboratory, MARIARC & Royal Liverpool University NHS Trust

ProSPECTus: What is new? ProSPECTus is a Compton Imager Radical change  No mechanical collimator Utilising semiconductor sensors Segmented technology and PSA and digital electronics (AGATA) Image resolution 7-10mm  2-3mm Efficiency factor ~10 larger Simultaneous SPECT/MRI

What’s different? Conventional SPECTCompton camera Gamma rays detected by a gamma camera Inefficient detection method Incompatible with MRI 2D information Gamma rays detected by a Compton camera Positions and energies of interactions used to locate the source 3D information. Source E0E0 Factors that limit the performance of a Compton Imager: Energy resolution, Detector position resolution, Doppler Broadening

Research : Compton Imaging o Compton Cones of Response projected into image space

Research : Compton Imaging o Compton Cones of Response projected into image space

Research : Compton Imaging o Compton Cones of Response projected into image space

Research : Compton Imaging o Compton Cones of Response projected into image space

Research : Compton Imaging o Compton Cones of Response projected into image space

1cm2cm 5cm 141keV Si(Li) Ge Total Coincident ~3.49% SPECT ~ 0.025% (typical value) Factor of ~140 Event Type% Single / Single2.23 Single / Multiple0.33 Multiple / Single0.61 Multiple / Multiple0.04 Not absorbed0.28 System Configuration GEANT4 simulations L. Harkness Ortec & SemiKon

Pulse Shape Analysis to decompose recorded waves Highly segmented HPGe detectors · · · · Identified interaction points (x,y,z,E,t) i Reconstruction of tracks e.g. by evaluation of permutations of interaction points Digital electronics to record and process segment signals  reconstructed  -rays Ingredients of  -Tracking

Utilise characterised sensors Am-241 AC x-y surface intensity distribution Uniformity of response for planar germanium crystals. AC01 AC12 DC12 DC1

Utilise unique pulse shape response AC signalsDC signals AC signals “superpulse” pulse shapes for 137 Cs (662 keV) events versus depth

Image Reconstruction Algorithms Sensors have excellent energy & position information. Uniformity of sensor response Optimise existing: –Analytical –Iterative –Stochastic Requirement for GPU acceleration

Compton Imaging ~7 º Angular Resolution FWHM, central position 2cm source separation 152 Eu E = 1408 keV 22 Na E = 1274 keV 152 Eu Multi-nuclide imaging No PSA (5x5x20) Cone back projection

Test existing gamma-ray detector in an MRI scanner Does the detector cause distortions in the MRI image? No Does the MRI system degrade the detector performance? In certain positions (which can be minimised) Encouraging results! MRI compatibility & Status

What are the next steps? Immediate priorities We have an integrated Compton Gamma camera optimised for <500keV Demonstrate sensitivity with phantoms Trials including clinical evaluation For the future: Consider electron tracking Si scatterer Possible use of large CZT analyser (requires large wafer material with 1cm thickness)

Security Imaging SNMs and other threats Coded aperture systems (low energy) Focus on wide FOV and variety of stand off distances Compton cameras

Location and Identification… The ability to locate and identify radioactive material with high precision Quantification of waste into low/intermediate/high brackets Wide range of activities from ~37kBq -> MBq There are many open challenges and opportunities Courtesy K. Vetter LBL LLNL)

Si(Li) + Ge Cryogenic solutions Mechanically cooled Battery powered Work in collaboration with Canberra

CZT Room temperature: PorGamRayS A portable gamma-ray spectrometer with Compton imaging capability (60keV – 2MeV) Gamma-ray spectroscopy/imaging with CZT detectors. Pulse Shape Analysis to refine spatial resolution and correct charge collection issues

137 Cs example image with CBP 370 5cm standoff19mm FWHM

133 Ba example image with CBP 340 5cm standoff 19mm FWHM

Compton Imaging Typical measurements: 10μCi 152 Eu 6 cm from SPET 1 Source rotated Zero degrees in 15º steps up to 60º Detector separation 3 – 11cm in 2cm steps Gates set on energies 2 sources 152 Eu and 22 Na at different x and y Use of the SmartPET detectors in Compton Camera configuration

FWHM ~ 8mm 6 cm source to crystal 30 mm crystal to crystal E = 1408 keV, 30 keV gate Compton Camera measurements (Ge/Ge) No PSA (5x5x20) Iterative reconstruction

Stereoscopic Optical Image Fusion 1.5m standoff A Compton Camera provides 3D source location Utilise a 3D optical imager Bubblebee 3 camera head

The next steps A number of preclinical and field trails are under way. Utilise e-tracking to reduce the uncertainty in the final image Improved image reconstruction Simplified electrode structure Further use of room temperature sensors

Andy Boston Imaging devices for medicine and security