UPS SG-CE Series 300 kVA. SG-CE Series 160-300 kVA S1 Sales presentation SAP_SGS_XCE_M16_M30_1GB_V011.ppt 2 Product portfolio CE Marked, 3x380/400/415V.

Slides:



Advertisements
Similar presentations
UPS Topologies and Multi-Module Configurations
Advertisements

CL100D series DSP controlled Uninterruptible power supplies.
G.E. UPS Productline.
Siemens Building Technologies Building Technologies Variable Frequency Drives Harmonics Overview.
POWER ELECTRONICS Multi-Step VSI vs GTO CSI. Power Electronics España S.L. © reserves the right to modify the content without prior notice 01 GTO CSI.
LP-31 Series Uninterruptible Power Supply Product Management GE Consumer & Industrial Power Protection.
Delta Confidential Apr GAIA-series 5-11KVA Introduction.
LP33 Series UPS kVA 400Vac/CE
1 Presentation Protect ph ~ / 3 ph ~ transformerless 3 ph ~ / 1 ph ~ 3 ph ~ / 3 ph ~ PROTECT PROTECT PROTECT PROTECT
DPA TM UPScale Best-in-class modular UPS for maximum availability.
NT series introduction UPS training June 2006 Markus Schwab.
AC Power Supplies Applications –Standby source for “critical” loads (computer) –Primary source when normal ac not available Uninterrupted Power Supply.
Delta Confidential DES UPS introduction UPS training June 2006 Markus Schwab.
PHI ModulR+. PHI ModulR+ Agenda: Modular UPS of 10 x 8 = 80 KVA 1.Description and Characteristics 2.The large system of 10 modules 3.The reduced system.
Chapter 8 Inverters AC Power • Inverters • Power Conditioning Units • Inverter Features and Specifications.
UPS series PROTECT 1.M Scalable UPS in n+x technology Modularity with double conversion UPS modules True sine wave - output.
BORRI Company and Products 2012
GE Critical Power © 2010 General Electric Company. All Rights Reserved. This material may not be copied or distributed in whole or in part, without prior.
LECTURE 28 AC Voltage Controllers Dr. Rostamkolai
SitePro UPS 400Vac / CE GE Consumer & Industrial August 2004.
UPS SG-CE Series kVA Sales presentation.
LP Series 11/31T - Uninterruptible Power Supply Product Management GE Consumer & Industrial Power Protection.
Newave SA, Switzerland – - 28/02/ Conceptpower Modular 80 and 100kVA THE BEST WAY TO PREDICT THE FUTURE IS TO INVENT.
SG-CE Series kVA PurePulse®
AC backup solutions for business continuity. Secure your business, Stay on!
Show information... Navigation links: Move the cursor across the links and wait for the “hand” symbol - then click left mouse key. Click the APC logo link.
Uninterruptible Power Systems
POWER PLANT USED IN TELECOM
MarsⅡ On-Line UPS Series
ENERGY of 21 st Century Independent Power Supplies.
Confidential / Property of Danfoss Drives A/S DKDD-SMC 1 Drives Division Danfoss presents - VLT ® 2800 Series.
CONCEPTPOWER DPATM Newave unique MODULAR power protection concept for mission critical applications Conceptpower DPA 28 March 2011.
PowerScale 10-50kVA Ed Maximize your availability.
LP Series U Technical presentation ISO 9001 UL CUL FCC Class A CE.
Modular Inverter.
RACK Mountable & Modular Continuous Power Protection Availability
Today’s presenters: Carlo Quiriconi Technical Services Manager Graham Higginson Area Manager Qld
Power Protection Stowe Australia Welcomes QESTnet Data Centre Construction Workshop Seminar Stowe Australia Welcomes QESTnet Data Centre Construction Workshop.
Power Quality Product Overview
LP Series 400V CE GE Consumer & Industrial September 2004.
TLE Series UPS kW CE. Page 2 TLE Series kVA/kW CE Product Range TLE Series UPS kVA/KW 160,200,320,400 kW High efficiency UPS Introducing.
1\ Backup system for solar on-grid installation 1 1pcs XTM inverter charger, nominal power 3.5KVA, 30min. Power 4KVA AC DC Load2 (secured power)
1 Powerware kVA The modular, scalable, redundant UPS for midrange applications.
InfraStruXure Systems Alex Tavakalov
A DSP based on on-line UPS R.Padamaja G.Mamatha Reddy EEE EEE S.V.C.E S.V.C.E BY.
Energy Conference and Exhibition 2007 Best Practices for Energy-Efficiency in Critical Power Applications Kit Killingsworth.
Increase your efficiency with Schneider Electric
Auxiliary power supply (APS) Hossein Harimi 2014
PHASE CONTROLLED CONVERTERS
RACK Mountable & Modular Continuous Power Protection Availability
POWER ELECTRONICS & ITS APPLICATION
Visit for more Learning Resources
RACK Mountable & Modular Continuous Power Protection Availability
VH Series How to Compete Against…
SPOC Automation and BECI- who are we?
Five level diode clapmed inverter
Power distribution and UPS in a single, compact system
PowerValue 11 RT Sales Presentation
True modular UPS system for critical applications
Maximize your availability
PowerValue 11/31 T Sales Presentation
Electromechanical Systems
Best-in-class modular UPS ensuring business continuity
بِسمِ اللهِ الرَحمنِ الرَحیم
Robicon Perfect Harmony.
AC Drives Dr. Adel A. El-Samahy Department of Electrical Engineering University of Helwan.
Presentation transcript:

UPS SG-CE Series 300 kVA

SG-CE Series kVA S1 Sales presentation SAP_SGS_XCE_M16_M30_1GB_V011.ppt 2 Product portfolio CE Marked, 3x380/400/415V In & Out, 60Hz 300 kVA ALL IGBT UPS 입력 고조파 4% 이하 입력역률 0.99(1) 출력 효율 94% 이상 (ECO 모드 97%) 진정한 True on-line UPS 6 대까지 병렬운전 (RPA) UPS SG-CE Series 300kVA PurePulse TM

SG-CE Series kVA S1 Sales presentation SAP_SGS_XCE_M16_M30_1GB_V011.ppt 3 Double conversion 6 RPA 병렬운전 Designed for Mission Critical Applications True On-Line Double Conversion VFI technology (Voltage and Frequency Independent)( 전압 주파수 독립작인 온라인 UPS) Inverter output transformer for load galvanic separation( 출력 인터터의 복권트랜스기본내장 ) Inverter DC Battery bank AC DC Static bypass Rectifier Bypass supply Load Rectifier supply Redundant Parallel Architecture™ RPA™ up to 6 UPS units Increase system reliability and security Expanded UPS installed power

SG-CE Series kVA S1 Sales presentation SAP_SGS_XCE_M16_M30_1GB_V011.ppt 4 High power concentration New technology for actual and future trend /1500 Reduced footprint Compact design saving space in installation: 300 kVA: 1500 x 850 x 1900 mm Full active power available Full power capability to supply - inductive loads - resistive loads - capacitive loads Suitable for actual loads applications, e.g. capacitive loads in new datacentre

SG-CE Series kVA S1 Sales presentation SAP_SGS_XCE_M16_M30_1GB_V011.ppt 5 Performances for actual and future trend High efficiency and clean input technologies for modern applications Efficiency 0% 20% 40% 60% 80% 94% 100% 10%25%50%75%100% Load Efficiency % Typical Operation High efficiency at any load 어떤 부하에서도 아주 높은 사용효율 배가 Total Input Harmonic Distortion Load 0% 1% 2% 3% 4% 5% 6% 0%20%40%60%80%100% THDi Clean input UPS by PurePulse™ technology 입력 고조파가 현존 최저수준인 THDi<4% 로 입력 전기 공사비 최하 40% 이상 절감 Input power factor: PF=0.99 으로 기존장비 대비 19% 의 피상전력 전기 사용절감

SG-CE Series kVA S1 Sales presentation SAP_SGS_XCE_M16_M30_1GB_V011.ppt 6 Compact design True front access for operation and maintenance, saving installation space UPS Footprint SG 200kVA UPS: x = 1.15 sqm Operational: x = 2.16 sqm Reduced footprint Compact design saving space in installation 300 kVA:1500 x 850 x 1900 mm Wall type 로 기존장비 대비 면적이 40% 이상 감소 & 전면 유지보수가능 기존장비 대비 항온 항습비용 50% 이상 절감 TCO 개념에서 총 구매 및 유지보수 관리비용이 절대적으로 감소 입력 역률 0.99 로 기존장비 대비 피상전력 무부하 손실 19% 감소 /1500

SG-CE Series kVA S1 Sales presentation SAP_SGS_XCE_M16_M30_1GB_V011.ppt 7 Perfect integration with GenSet No GenSet oversizing required GenSet integration Example Load300 kVA; PF=0.8; 240 kW UPSSG 300 kVA Pure Pulse; input PF = 0.99 GenSet datareactance subtr. X“d=12% GenSet sizemin. size required 332 kVA GenSet/UPS = 332/300 = 1.1 Compatible with GenSet design Saving GenSet size (suggested GenSet vs. UPS ratio ~ 1.1*) Reducing GenSet installation space( 기종장비 대비 발전기 설계용량이 배수준으로 저감 ) 발전기 투자비용절감 (50% 이상 ) 발전기 연동 효용가치 증대 발전기와 UPS 의 연동 (dedicated auxiliary contact) 발전기 제어를 UPS 와 연동 고한리 가능 (Gen on/off) *Pure Pulse configuration and GenSet able to manage large load steps

SG-CE Series kVA S1 Sales presentation SAP_SGS_XCE_M16_M30_1GB_V011.ppt 8 Reduntant Parallel Architecture True redundancy with no single point of failure 최대 6 대 까지 병렬운전 rectifierbypassrectifierbypass critical load DC AC DC battery Input mains DC AC DC battery Modular design 미래 확장성 TCO 개념에서 용량증대 시 비용저감 True redundancy BTBF 시간이 증대하여 다운타임제로화 Decentralized bypass 로 용량 증대시 비용저감 및 바이패스 회로 확장에 따른 추가비용이 없음 총 6 개 까지 용량 증대 Increased system reliability mission critical applications” 에서 신뢰성 증대 생산력 증대 진정한 이붕변환 및 멀티 테스킹안전관리 손쉬운 용량 증대

SG-CE Series kVA S1 Sales presentation SAP_SGS_XCE_M16_M30_1GB_V011.ppt 9 Designed for serviceability Saving time and cost in service( 손쉬운 유지보수 ) 손쉬운 전면 유지보수 유지보수 시간의 단축 및 관리 용이 전면 관리로 측면 및 후면 관리가 필요 없음

SG-CE Series kVA S1 Sales presentation SAP_SGS_XCE_M16_M30_1GB_V011.ppt 10 Power Quality Systems Integretion with other Power Quality euipments for Mission Critical Applications UPS-A UPS-B Battery- A Battery- B ISM STS-A STS-B Load-A Load-B Input mains UPS:Uninterruptible Power Supply ISM:Intelligent Synchronization Module STS: Static Transfer Switch

SG-CE Series kVA S1 Sales presentation SAP_SGS_XCE_M16_M30_1GB_V011.ppt 11