Welcome Welcome to GEMCO CONTROLS LIMITED www.gemcocontrols.com.

Slides:



Advertisements
Similar presentations
Variable Frequency Drives Bypass Options
Advertisements

CL100D series DSP controlled Uninterruptible power supplies.
E300 Series Mini-type Integrated Universal Inverter
Static Transfer Switch
Model W Wall Mount Static Transfer Switch. Why choose a model W static transfer switch? Increases power availability. Integrated maintenance bypass. True.
Submitted by: Name:Rajendra Kumar Choudhury Branch:Electrical Engg.
ABB standard drive Enhanced ACS550
MOLDED CASE CIRCUIT BREAKER BASICS
Motors & Motor Starters
© ABB Ltd - ATLV /26/2015 Insert image here Fuses vs Fuseless Technology.
PERTEMUAN 14 PENGUKURAN ENERGI. Measurement of Energy Energy is measured by means of the energy meter (watt-hour- meter) Energy meter is an integrating.
Traction Control of Electric Locomotives
LP-31 Series Uninterruptible Power Supply Product Management GE Consumer & Industrial Power Protection.
MODULAR SMPS POWER PLANT
SYMAP-BC SYMAP-BC.
GST FIRE ALARM SYSTEM INTERNATIONAL BUSINESS DEPARTMENT , GST BEIJING
Enabling Objective 1.3 Describe the Design of the Magnetek Impulse VG+ series 3 Variable Frequency Drive Controller.
A TECHNICAL PRESENTATION BY: ERIC BABSKI Controlling Electric Motors.
CSX Product Familiarisation Presentation to Audience - 15 September 2006.
Lesson 33 AC Generators.
G GE Power Management MMII Intelligent MCC Controller.
CheckMeter 2.3 Portable Working Standard Page 1 March 2009.
Three-Phase AC machines Three-Phase Cage Rotor Induction Motor – Electronic Methods of Starting and Speed Control Resource 4.
Solar Home UPS 850VA & 1400VA India’s first Sine wave inverter with in built Solar Charge Controller and Controlled DC Load Output. Simultaneous Charging.
AC MOTOR INDUCTION MOTOR.
A new addition to the AuCom family of soft starters
1 Electronic Soft Starters How and Why they Work, and What they can do for You. Fairford North America.
Rocker Switches  Available in illuminated, Non-illuminated and Central illuminated version  Suitable for switching resistive and inductive load  Wide.
Introduction for TECO SERVO 9300 Series
Lesson 9: Electrical Components
Scheduled Versus Event Driven Testing of Distribution Protection IEDs Dr. Alexander Apostolov, Benton Vandiver, Will Knapek, OMICRON electronics.
© 2006, ZTE Corporation. All rights reserved.   E300 Series Mini-type Integrated Universal Inverter.
FG Wilson Access 4000 Control Panel
POWER PLANT USED IN TELECOM
Smart transmitters.
ENERGY of 21 st Century Independent Power Supplies.
Single Loop Analogue addressable fire control Panel
Confidential / Property of Danfoss Drives A/S DKDD-SMC 1 Drives Division Danfoss presents - VLT ® 2800 Series.
COMPONENTS REQUIRED STEP DOWN PRANSFORMER:
A smart signalling system for Indian railways Smart signalling system – user’s view Full capacity realisation Flexibility of movements Easy to operate.
Modular Inverter.
TYPICAL SCADA SYSTEM FIELD UNIT SCADA H/W & S/W C TX O RX M E M Q N P
Motor-driven pumps  Sigma/ 1  Sigma/ 2  Sigma/ 3.
Copyright © 2011 Rockwell Automation, Inc. All rights reserved. Insert Photo Here OneGear™ SMC™ Flex Controller kV.
YASKAWA VS-606 V7 COMPACT VECTOR - CONTROLLED INVERTER FOR GENERAL USE 230V (Single-Phase).1Kw ~ 3.7Kw (.13HP ~ 5HP) 230V (Three-Phase).1Kw ~ 7.5Kw (.13HP.
SmartMQn Motor Horner APG, LLC September 9, 2008.
EPack relaunch. Schneider Electric 2 -Industrial – Eurotherm – 16/12/2015 ●1. Reduce your equipment costs.
CUE – Make Any Pump an E-Pump
CheckMeter 2.1 Portable Working Standard Page 1 March 2009.
Alarm units AL 175 NT and Aeon Gold For small, medium and large power range.
G GE Power Management 269Plus Motor Management Relay.
AC Machines. BOOSTER Basic Function:- -Sometimes when we use electrical power we need different voltage level to main supply. It is provided by Booster.
Pag. 1 VAT200, General Purpose AC Drive Mini AC Drive VAT200.
CLOSED LOOP SPEED CONTROL OF DC MOTOR WITH PWM TECHNIQUE
Elements of Electrical Design HASMUKH GOSWAMI COLLEGE OF ENGINEERING
CNC FEED DRIVES.
POWER FACTOR CORRECTION
PERTEMUAN 14 PENGUKURAN ENERGI.
MEDIUM VOLTAGE APPLICATIONS.
Electric Machine Induction Motor
Enclosed Parking Ventilation 1 EK Engineering (India) CO/NO2 detection, Fan Control and automation System E: Mobile:
FEEDER PROTECTION UNIT
Motor Drive Prof. Ali Keyhani. Modern Variable Speed System A modern variable speed system has four components: 1. Electric Motor 2. Power Converter -
PowerLogic™ offer for the basic metering market
SMPS POWER PLANT SMR 48V/25A SALIENT FEATURES
Presentation transcript:

Welcome Welcome to GEMCO CONTROLS LIMITED

DIGITAL DC DRIVES & SYSTEMS UPTO 5000 KW Digital DC Drives GEMCO GEMCO Digital Convertors are dedicated for industrial applications in which good static and dynamic performance and independent controls of speed, acceleration, torque, tension etc. are essential. Various special features include :  Auxillary transducers controls, encoders, inputs, dancer arms, load cells etc.  Choice of several operating & control modes.  Automatic management of operating sequences.  Serial communication with a PC or Gemco Video Keyboard.  Serial communication amongst various drive units for cascade / coordinated control.  Various Programmable inputs and outputs :  8 Digital Inputs and 4 Analogue Inputs.  4 Digital Outputs and 2 Analogue Outputs.

 Independent auxillary 24V DC power supply, allows use of wide range 3 phase supply, 110V-500V AC  Speed feedback from Armature Voltage tachogenerator or pulse encoder.  Drive for multiple motors Machines with internal management of special function as:  Tension controls with Diameter calculation, inertia and friction compensation etc.  Synchronisation of sectional Drives with Draw / Ratio control.

PROTECTIONS & SELF – DIAGNOSTIC GEMCO GEMCO Convertors are equipped with in built protection against various abnormalities with clear indications. Various alarm levels programmable through serial line include :  Wrong sequence of three-phase line phases.  Insufficient three-phase line voltage.  Excessive three-phase line voltage.  Phase currents unbalancing (Fuses Failure / Current Ripples).  Integral current thermal motor protection (over loading).  Minimum field excitation current.  External motor protections (ventilation, thermostat).  Excessive converter temperature.  Unbalancing between reference and motor speed.  Unbalancing between armature voltage and speed.  Synchronism ramps error.  Thyristor firing pulses error.  EEPROM writing error.  Wrong parameters in EEPROM.  Wrong control circuits supplies.

ANALOGUE DC DRIVES Very simple design. Dependable performance Easy maintenence. Long life. Several Drives operating trouble free for last over 25 years. Salient Features of Gemco Thyristor Drive Panels  Mains Isolator Switch/ ACB/ MCCB in the Incomming AC supply.  Input AC supply variations upto ± 15% permitted.  System immune to input supply phase sequence.  Fully Controlled 6 Pulse / 12 Pulse Thyristor Convertors.  Surge Voltage Suppression.  Snubber Circuits across each power device provided.  High Speed Fuses for Thyristor Protection.  Electronic Over Current Tripping.  Motor Overload Protection Relay Provided.  Single Phasing Protection.

 Field Failure Protection Relay Incorporated.  Electronic Circuit to Indicate Blown Fuse.  Adjustable Current Limit 0-150%.  Gradual Acceleration of motor with adjustable ramp time of 2 to 30 seconds  15. Line Reactors in each ac line provided for DI / DT protection  Over Temperature Tripping  Single Plug in Glass Epoxy PCB with latest electronic circuitary used to give the desired performance.  Front Accessible Test Points at various stages.  Electronic Leds at various stages of circuits for easy fault diagnostics.  Front Accessible and simple adjustments on the electronic card.  Simple & Rugged circuitary for reliable and trouble free operation.  front accessibility of all components permits very easy and quick trouble shooting and rectification.  Use of single card helps reduce down time as the card can be replaced quickly even by an electrician.  Selection of voltage or tachogenerator feedback.  DC Voltmeter/ DC Ammeter / RPM Meter provided on front of panel.  Eight Point Led fault display window on the front of panel.  Optional Overvoltage / Undervoltage / Over Speed Tripping Offered

SOFT STARTERS (25 AMPS TO 1000 AMPS) Soft Starters Microprocessor based heavy duty Soft Starters from Gemco are highly reliable and rugged using sophisticated controllers from Fairford UK, with most advanced features, which makes them an instant selection leading to innumerable benefits. SALIENT FEATURES  Continuous display of motor phase current & control status.  Easily changed parameter settings via keypad.  Peak starting current recording.  User adjustable overload.  Last 5 trips recording

 110/230V control supply.  User selectable built-in application specific settings.  Isolated control inputs – 24V DC 230V AC for start/stop or user programmable.  Current limit time out – optional trip or continue.  Undercurrent trip level or delay: 0-1 x FLC.  Adjustable optimizing response rate.  Adjustable starting current limit control.  Separately adjustable ramp up/down times from 1 sec to 240 seconds.  Adjustable kick start for high break away torque applications.  Fully adjustable pedestal voltage.  User adjustable shearpin.  Control of resistive loads.  Thermistor trip input.  4-20mA input for monitoring.  DC input for monitoring.  Optional Serial Communications  IP 20 Rating.  An Alphanumeric Digital Display with soft keys for monitoring of operating and setup parameters

ADVANTAGES OF GEMCO SOFT STARTER  Reduction in high starting currents  Elimination of inrush currents.  Smooth, stepless acceleration to full speed.  Snatch free starting removing mechanical stress.  Extended contactor life  Reduced wear on mechanical transmission components.  Automatic energy optimizing.  Improved power factor at light loads, reduced kVA demand.  Suitable for all types of induction motor.

MOTOR CONTROL CENTERS(MCC'S) For plant process motor controls Gemco offers MCC Panels which are type tested at CPRI for  Short circuit withstand capacity upto 70KA for 1 second  Temperature rise test  Degree of protection IP 54 The Panels can be fixed type or draw out type, single sided or double sided as per Clients specifications, totally enclosed type, floor mounted, dust and vermin proof. The construction of Panel is such that the cabling & maintenance is easier & can be extended on both sides in future. The bus bar used is Electrolytic grade aluminium / Copper well supported with high quality SMC/DMC insulators.

Intelligent MCCs (iMCCs) Using intelligent motor protection Relays with Profibus/Ethernet communication formonitoring motor operating parameters and fault alarms.

CONTACT US :- GEMCO CONTROLS LIMITED 14/3, Mathura Road, Faridabad Haryana ( India) – , – Thank You