Data Center Energy: Going Forward John Tuccillo, APC by Schneider Electric Founding Board of Director Member.

Slides:



Advertisements
Similar presentations
How Much? A study into accounting for Carbon and power in the Data Centre Steve Bowes-Phipps Data Centre Manager University.
Advertisements

New Paradigms for Measuring Savings
Test Automation Success: Choosing the Right People & Process
Environmental Management in Severn Trent Sue Painting Severn Trent Plc.
1 Leading Energy Efficiency in High Tech: PG&E’s Program & Service Portfolio Mark Bramfitt, P.E. CSU Dominguez Hills.
PI – Monitoring Energy in the Data Center Peter Vieites Technology Architect Microsoft Technology Center - New York.
Pacific Gas and Electric Company Leading Energy Efficiency in High Tech: PG&E’s Program & Service Portfolio Mark Bramfitt, P.E. Foster City CA September.
Application Models for utility computing Ulrich (Uli) Homann Chief Architect Microsoft Enterprise Services.
Joint Unit Liaison Meeting 1 INFORMATION AND TECHNOLOGY SERVICES Transforming U-M: Joint UL Meeting July 21, 2009.
ISO Energy Management System Certification
Energy Model for Multiprocess Applications Texas Tech University.
A Connected World in transformation NICE – DATACENTRES 2012 May 23 rd 2012 Paul-François CATTIER Global Data Centre Solution VP.
Creating Energy-Efficient Data Centers
Portfolio Manager—ICBA Members ENERGY STAR  Tools For Benchmarking and Tracking Energy Use.
Steve Craker K-12 Team Lead Geoff Overland IT and Data Center Focus on Energy Increase IT Budgets with Energy Efficiency.
CHAPTER OVERVIEW SECTION 5.1 – MIS INFRASTRUCTURE
AERC Members’ Meeting April 8, 2015 Alexandria, VA 4/8/2015Attachments Energy Rating Council1.
CLOUD COMPUTING. A general term for anything that involves delivering hosted services over the Internet. And Cloud is referred to the hardware and software.
Total Energy Usage As A Measure of Building Performance 30% Building Energy Savings Through an Energy Lifecycle Approach to Building Construction, Retro-fitting,
TECHNOLOGY GUIDE 3: Emerging Types of Enterprise Computing
Data Center Consolidation & Energy Efficiency in Federal Facilities
Green IT and Data Centers Darshan R. Kapadia Gregor von Laszewski 1.
Information Technology Division Executive Office for Administration and Finance Springfield Data Center Program Energy Strategy Meeting 9/29/2009.
Connectivity Week Santa Clara Convention Center May 23, 2011.
CHAPTER FIVE INFRASTRUCTURES: SUSTAINABLE TECHNOLOGIES
Open Science Grid For CI-Days Internet2: Fall Member Meeting, 2007 John McGee – OSG Engagement Manager Renaissance Computing Institute.
1 An SLA-Oriented Capacity Planning Tool for Streaming Media Services Lucy Cherkasova, Wenting Tang, and Sharad Singhal HPLabs,USA.
Thermodynamic Feasibility 1 Anna Haywood, Jon Sherbeck, Patrick Phelan, Georgios Varsamopoulos, Sandeep K. S. Gupta.
Common Carbon Metric for Measuring Energy Use & Reporting Greenhouse Gas Emissions from Building Operations A tool developed by GHG Protocol and UNEP-SBCI.
LBNL and Government Data Center Programs SC07 November, 2007 William Tschudi
ICT policies and the Lisbon Agenda Baltic IT&T 2005 Riga, 7 April 2005 Frans de Bruïne Director “Lisbon Strategy and Policies for the Information Society”
Quality Assurance. Identified Benefits that the Core Skills Programme is expected to Deliver 1.Increased efficiency in the delivery of Core Skills Training.
Liam Newcombe BCS Data Centre Specialist Group Secretary Energy Efficient Data Centres.
1 DOE Data Center Energy Efficiency Program and Tool Strategy Paul Scheihing U.S. Department of Energy Office of Energy Efficiency and Renewable Energy.
Liam Newcombe BCS Data Centre Specialist Group Secretary Modelling Data Centre Energy Efficiency and Cost.
Open Science Grid For CI-Days Elizabeth City State University Jan-2008 John McGee – OSG Engagement Manager Manager, Cyberinfrastructure.
Tag line, tag line Power Management in Storage Systems Kaladhar Voruganti Technical Director CTO Office, Sunnyvale June 12, 2009.
Virginia Information Technologies Agency Green Technology Initiatives
1 – Consciously Manage Our Capabilities At Intel IT, we think “green” everyday with a long-term strategy for IT sustainability.long-term strategy.
1 Distributed Energy-Efficient Scheduling for Data-Intensive Applications with Deadline Constraints on Data Grids Cong Liu and Xiao Qin Auburn University.
May l Washington, DC l Omni Shoreham Green Design and O&M Practices for Technology and Hosting Facilities Ben Pasley Manager, Lee Technologies, Inc.
Overview of Data Center Energy Use Bill Tschudi, LBNL
1 Data Center Energy Efficiency Metrics ASHRAE June 24, 2008 Bill Tschudi Lawrence Berkeley National Laboratory
Power Association of Northern California Maintaining Grid Reliability In An Uncertain Era May 16, 2011 PG&E Conference Center Jim Mcintosh Director, Executive.
The Green Grid’s Data Center Maturity Model November 18, 2015.
Virtualization Supplemental Material beyond the textbook.
SAM for SQL Workloads Presenter Name.
Datacenter Energy Efficiency Research: An Update Lawrence Berkeley National Laboratory Bill Tschudi July 29, 2004.
From Use Cases to Implementation 1. Structural and Behavioral Aspects of Collaborations  Two aspects of Collaborations Structural – specifies the static.
Data Center Energy Use, Metrics and Rating Systems Steve Greenberg Energy Management Engineer Environmental Energy Technologies Division Lawrence Berkeley.
Green Action Team Meeting February 19, 2009 Status of Major Deliverables Green Building Initiative (Exec Order S-20-04)
Insights into Google's PUE Results Spring Published Google PUE Results.
1 Workshop “Energy Efficiency management in chemical Industry sector" Thessaloniki, Greece Use of CARE +Tools in Bulgaria energy management.
Data Analytics – A Cost Effective Approach to Reducing Operating Costs Automatically “find what matters” in the data from building equipment systems and.
From Use Cases to Implementation 1. Mapping Requirements Directly to Design and Code  For many, if not most, of our requirements it is relatively easy.
Monitoreo y Administración de Infraestructura Fisica (DCIM). StruxureWare for Data Centers 2.0 Arturo Maqueo Business Development Data Centers LAM.
Profiling and Characterising Software Application Energy Consumption Ian Osborne ICT KTN and EEC SIG.
Designing a Grid Computing Architecture: A Case Study of Green Computing Implementation Using SAS® N.Krishnadas Indian Institute of Management, Kozhikode.
New Members Webcast September 30, Agenda Communications Committee: Michelle O’Brien – Web WG – EMEA CWG – Japan CWG Liaison Committee: VTM Technical.
Enabling High Efficient Power Supplies for Servers
Green cloud computing 2 Cs 595 Lecture 15.
Greening Your Information Systems
DOE Data Center Energy Efficiency Program and Tool Strategy
Exam 1 Study Guide Cs 595 Lecture 17.
CHAPTER OVERVIEW SECTION 5.1 – MIS INFRASTRUCTURE
News and computing activities at CC-IN2P3
Towards Green Aware Computing at Indiana University
Jim Mcintosh Director, Executive Operations Advisor California ISO
Presentation transcript:

Data Center Energy: Going Forward John Tuccillo, APC by Schneider Electric Founding Board of Director Member

Today’s Data Center Challenges NEED FOR MORE WORK IT Applications Analysis Servers Storage REAL-WORLD LIMITATIONS Financial Constraints Power Availability Cooling Capacity Space Energy Efficiency

What If… The Data Center Was An Example of Excellence? MORE WORK IT Applications Analysis Servers Storage REAL-WORLD LIMITATIONS Financial Constraints Power Availability Cooling Capacity Space Energy Efficiency

The Goal: Efficiency Models and best practices for using those technologies Existing and Emerging Technologies Data center characteristics, performance metrics, and measurement protocols Multi-Step Process

Who’s In The Green Grid? Board of Director Member Companies

More Than 200 Members: A Broad Spectrum

’08 Deliverables Driving Industry Thought Leadership! #6 Green Grid Data Center Power Efficiency Metrics: PUE and DCiE #7 Five Ways to Save Server Power Consumption #8 Data Center Baseline Study Report #9 Addressing Organizational Behavior Issues in IT #10 Framework for Establishing a Rating System #11 Seven Strategies to Improve Data Center Cooling Efficiency #12 The Green Grid Peer Review of “DC Power For Improved Data Center Efficiency” by LBNL #13 A Framework for Data Center Energy Productivity (DCeP) #14 The Green Grid Metrics: Data Center Infrastructure Efficiency Detailed Analysis #15 The Green Grid Productivity Indicator #16 Quantitative Efficiency Analysis of Power Distribution Configurations for Data Centers

The Green Grid in 2009: Helping Industry Move Forward

Why Create Metrics? Awareness o “If you can’t measure it, you can’t improve it” Benchmarking o Continuous improvement of operations o Comparing across the industry o Improvement over time/generation to generation o Validate claims Consistency o Common Vocabulary o Industry & Government Collaboration o Better Efficiency

PUE/DCiE: The Green Grid Metrics For Facilities Total Facility Power IT Equipment Power PUE = Power Switchgea r UPS Battery Backup etc. Cooling Chillers CRACs etc. IT Equipment Servers Storage Telco etc. PUE & DCiE For Efficient Facilities DCP For The Work You Do Total Facility Power Total Facility Power IT Equipment Power DCiE = X 100% What % of facility power is delivered to my IT equipment? How efficient is my facility in delivering power to IT equipment? IT Equipment Power

PUE and DCiE: Do/Do Not PUE and DCiE Do: PUE and DCiE Do Not: Provide information on how effective the energy is being used by the IT equipment in a facility Provide a good picture of efficiency when used consistently over time Provide a starting point to determine the effectiveness of energy use in a data center Address emerging models such as containers Address the kinds of energy sources that the facility uses Adequately help an organization if measurements taken on a one- time basis Serve as the final word on efficiency Address productivity

Sample Data Center: PUE Impact Assumptions 5 Mw IT load $0.10/kW-hr 7x24 operation Sample data center: PUE Mw purchase from utility $8.8 million annual power bill Best in class: PUE Mw purchase from utility $6.1 million annual power bill Net Savings of $2.7 Million Annually Through Increased Efficiency

New PUE/DCiE Reporting Guidelines Total Facility Power IT Equipment Power PUE = What were the environmental conditions? When were measurements taken? Where were measurements taken? How often were measurements taken? Total Facility Power IT Equipment Power DCiE = X 100% What % of facility power is delivered to my IT equipment? How efficient is my facility in delivering power to IT equipment? How to compare results?

Measurement Accuracy Reporting (from DCiE Detailed Analysis WP)‏

Examples of Reported Results ‘M’ = monthly ‘W’ = weekly ‘D’ = daily ‘C’ = continuously (frequency one hour or less)‏

Classification of Publicly- Reported Metrics Results

Intended Results of Reporting Guidelines Consistent, apples-to-apples reporting Identify and Promote exceptional results Quality Assurance Drive greater industry adoption

DCP: Under Development Power Switchgear UPS Battery Backup etc. Cooling Chillers CRACs etc. IT Equipment Servers Storage Telco etc. PUE & DCiE For Efficient Facilities DCP For The Work You Do Total Facility Power Useful Work Total Facility Power DCP = How Much Work Can My IT Equipment Do, In My Facility? IT Equipment Power

Productivity Proposals Proxy NameDescription Useful Work Self-Assessment and Reporting All applications self-report, utility function is uniform and equal to one; user must decide how to normalize each task DCeP Subset by Productivity LinkA subset of all applications self-report using Productivity Link, a freely available Software Development Kit (SDK); scale results to represent whole data center DCeP Subset by Sample WorkloadAn instrumented subset of servers is measured running as sample workload; scale results to represent whole data center Bits per Kilowatt-hourSum all outbound bitstreams from data center, divide by energy used by data center Weighted CPU Utilization – SPECint_rate Use CPU clock speed, SPECint_rate benchmarks, and CPU utilization to determine amount of work being done. Weighted CPU Utilization – SPECpower Use CPU clock speed, SPECpower benchmarks, and CPU utilization to determine amount of work being done. Compute Units Per Second (CUPS)Uses trend curve based on Moore's law, age of server, and CPU utilization to determine work done. Operating System Workload Efficiency Estimate efficiency by calculating the number of operating system instances per watt

DCP: Productivity Proxies Goal is to move the discussion forward The Green Grid is gathering feedback on proxy proposals from members and industry Best prospects will be selected for further study 8 Proxies are proposed

The Green Grid Productivity Indicator Simple, quick visualization of how resources are being targeted versus used Radial graph for relevant indicators such as: o data center efficiency, o data center utilization o IT utilization

The Green Grid Data Center Design Guide For building and operating energy efficient data centers Covers existing and new facilities Designing the data center architecture as a whole, not in pieces ICT Equipment Facilities PowerCooling ComputeStorageNetwork Management Infrastructure Applications

Core Tenets of Data Center 2.0 Design Guide A guide for standardization and evolution of key capabilities

Annual Design Guide Releases Evolution of the design guide should advance all core tenets

Power Configuration Tool How do I compare power topologies while keeping efficiency in mind?

Free Cooling Map How much “free” cooling is available to me, at any location in the US?

PUE Calculator‏ Under Development

Training The Green Grid Academy Online Courses Interactive & Self-Driven

Collaboration: Liaisons for Government, IT, Facilities

Collaboration: Advisory Council

We Can Get There Together MORE WORK IT Applications Analysis Servers Storage REAL-WORLD LIMITATIONS Financial Constraints Power Availability Cooling Capacity Space Energy Efficiency

Work with us! For more information: