M. Kainz 1, G. Mitterer 1, M. Freudenschuss 2, G. Häubl 3, R. Krska 3 1 ROMER LABS Division Holding GmbH, Technopark 1, 3430 Tulln, Austria 2 Biopure Referenzsubstanzen.

Slides:



Advertisements
Similar presentations
A guide for GCSE students KNOCKHARDY PUBLISHING
Advertisements

Figure 5: LC/MS/MS of a Blank Feed Sample spiked with 200 µg/kg Deoxynivalenol. Clean-up Bond Elut Mycotoxin Figure 6: LC/MS/MS of a Deoxynivalenol contaminated.
Primary Standards Is a highly purified compound that serves as a reference material in all volumetric and titrimetric methods. It must be: –1) Highly pure,
Gas Chromatography.
Gas Chromatography, GC L.O.:  Explain the term: retention time.  Interpret gas chromatograms in terms of retention times and the approximate proportions.
Fundamentals of Method 23 What You Always Wanted to Know About EMPC but were Afraid to Ask Office of Air Quality Planning and Standards Air Quality Assessment.
Caffeine as a Surrogate for Cocaine in an HPLC Forensic Experiment Ray A. Gross Jr, Indravadan Shah and Muhamed Jasarevic Department of Physical Sciences.
Result validation. Exercise 1 You’ve done an analysis to the best of your ability using the correct procedure. Is your answer correct? possibly, hopefully.
Pesticide screening LC-QTOF, Agilent. National Food Institute, Technical University of Denmark Disposition National Food Institute –EURL –NRL –Personale.
HPLC Coupled with Quadrupole Mass Spectrometry and Forensic Analysis of Cocaine.
* CORRESPONDING AUTHOR Bioanalysis of Exenatide: Intact Versus Signature Peptide Approach to Reach Optimal Sensitivity in Large Molecule Quantification.
P. 1 FAQs- before analyzing your sample. p. 2  Temperature (thermal degradable?)  Split or splitless  Split ratio  Injection volume FAQs- injection.
Development of an Automated, Pyridine Free Method for Aerosol Cyanide Compounds and Hydrogen Cyanide. An Alternative to NIOSH LeRoy Dobson, Chemist.
In carbon-13 NMR, what do the number of peaks represent?
In this contribution we present a new automatic procedure for background correction that, for the first time, can be successfully applied in both isocratic.
Presented by Meng Shi The C holesterol in plasma was a important factor to lead Thrombus.
Vinh Tran Chem Fall 2011 December 9, 2011.
Quantitative Analysis of Humulene in Beer Joseph Frederick CHEM 4101, Fall 2010 December 10, 2010.
Fa 05CSE182 CSE182-L9 Mass Spectrometry Quantitation and other applications.
CALIBRATION METHODS.
Quality Control In Measurements Tom Colella CLAS Goldwater Environmental Lab.
Perchlorate April 14, 2004 An Integrated Approach to Ensure Reliable Perchlorate Analytical Results.
Application of HR-LC-MS in screening methods for pesticides in cereals
Quantitative Chemical Analysis Seventh Edition Quantitative Chemical Analysis Seventh Edition Chapter 0 The Analytical Process Copyright © 2007 by W. H.
* CORRESPONDING AUTHOR Use of High Resolution Mass Spectrometry (HRMS) to Solve Severe Issues Due to Isotopic Distribution in Regulated Bioanalysis Richard.
LC-MS/MS Analysis of Naphthenic Acids in Environmental Waters Coreen Hamilton, Million B. Woudneh & Guanghui Wang Presented at Workshop on Analytical Strategies.
© 2010 SRI International - Company Confidential and Proprietary Information Quantitative Proteomics: Approaches and Current Capabilities Pathway Tools.
Bias and Errors. Some Terms Used to Describe Analytical Methods Accuracy Precision LOD RDL LOQ Selectivity Sensitivity Linearity Ruggedness.
Mass spectrometry session. Summary Fiehn (1) Standardization important Reporting important, but has to be feasible Does not matter which MS instrument.
INTRODUCTION AND OBJECTIVES The presence of mycotoxins residues in pollen pose a potential risk to human health (1). In this study we performed a multiresidue.
Mike Rusak and Laura Fairburn CURRENT OBSTACLES ON THE APPLICATION OF AMBIENT IONIZATION MS IN FORENSICS.
Quality Assurance How do you know your results are correct? How confident are you?
CALIBRATION METHODS. For many analytical techniques, we need to evaluate the response of the unknown sample against the responses of a set of standards.
Polybrominated diphenyl ethers by HRGC/HRMS Coreen Hamilton Brian Fowler Louis Haviland Axys Analytical Services, Ltd.
Application of Method 1668A to the Analysis of Dioxin-Like PCBs and Total PCBs in Human Tissue and Environmental Samples Coreen Hamilton, Todd Fisher,
Evaluation of Zirconia Adsorbents in QuEChERS Cleanup for Hazelnut, Avocado and Soybeans Hans Ragnar Norli, Gunvor Viki Seneset, Nina Svendsen, Agnethe.
7000A GC-QQQ Applications Pesticides in Foods (1).
Data Analysis and Presentation Chapter 5- Calibration Methods and Quality Assurance EXCEL – How To Do 1- least squares and linear calibration curve/function.
Advanced Analytical Chemistry – CHM 6157® Y. CAIFlorida International University Updated on 9/26/2006Chapter 3ICPMS Interference equations Isobaric.
OPTIMIZATION OF BISPHENOL A, 4-t-OCTYLPHENOL, AND 4-NONYLPHENOL EXTRACTION FROM HUMAN BLOOD SERUM WITH HYBRID SOLID PHASE EXTRACTION – PROTEIN PRECIPITATION.
液相層析質譜分析 LC-MS Method development and Analyte Identification 授課教師:賴滄海教授 授課教師:賴滄海教授
IL Sustainable Technology Center (ISTC) Tour (20 points)
Dr Saleha Shamsudin. 1.INTRODUCTION Topics to be covered: 1.1 INTRODUCTION TO METHODS IN ANALYTICAL CHEMISTRY 1.2 STEPS IN QUANTITATIVE ANALYSIS.
© Copyright 2009 by the American Association for Clinical Chemistry Plasma Renin Activity by Liquid Chromatography– Tandem Mass Spectrometry (LC-MS/MS):
Chemistry 2412 L Dr. Sheppard
1 Chapter 2 Steps in a chemical analysis Plan of analysis Before doing any quantitative analysis, the following questions should be answered: 1-
Mass Spectrometry Quantitative Mass Spectrometry
Making Molar Solutions From Liquids (More accurately, from stock solutions)
PERFLUORINATED CARBOXYLIC ACIDS AND SULFONIC ACIDS IN WASTE SAMPLES Katsuya Y 1 *,Takemine S 1, Matsumura C 1, Tsurukawa M 1, Haga Y 1, Fujimori K 1, Nakano.
Primary Standards Is a highly purified compound that serves as a reference material in all volumetric and titrimetric methods. It must be: –1) Highly pure,
Objective  To develop methods for analysis of compounds in organic aerosol particles Why is this important?  Environmental impact  Alternative fuels.
John D. Vargo 1 ; Michael Schueller 1 ; Mary Skopec 2 1 State Hygienic Laboratory at the University of Iowa, Coralville, IA; 2 Iowa Department of Natural.
Forensic Toxicology Use Only Analysis of ETG, ETS using the Thermo Scientific Exactive Mass Spectrometer Kent Johnson Fortes lab, Portland Oregon.
Introduction The pyrolysis products of natural polymers often exhibit very similar neural losses during collision induced dissociation (CID) Some ions.
이 장 우. 1. Introduction  HPLC-MS/MS methodology achieved its preferred status -Highly selective and effectively eliminated interference -Without.
Multi-Analyte LC-MS/MS Methods – Best Practice.
M. Fernández, E. Conde, A.I. Barrado Department of Technology
Results and Discussion
Heterogeneity of mycotoxin contamination of crops
% € $ Multiresidue analysis of 25 pesticide residues in wines
Mycotoxins in Botanical Materials
A sensitive and repeatable method for characterization of sulfonamides and trimethoprim in honey using QuEChERS extracts with Liquid-Chromatography-Tandem.
Hydride Generation–AFS for Arsenic Speciation in Food
Using ultrasonic liquid extraction for estrogens analysis in sludge by HPLC with fluorescence detection Vitória Lourosa, Diana Limab, Jorge Leitãoc, Valdemar.
Volume 150, Issue 1, Pages e1-e4 (July 2016)
Nat. Rev. Nephrol. doi: /nrneph
MAO speciation by electrospray ionization mass spectrometry
EQS 17β-estradiol 17a-ethinyl-estradiol 0.4 ng/L 35 pg/L
Chromatography Daheeya Alenazi.
Levofloxacin structural formula
Presentation transcript:

M. Kainz 1, G. Mitterer 1, M. Freudenschuss 2, G. Häubl 3, R. Krska 3 1 ROMER LABS Division Holding GmbH, Technopark 1, 3430 Tulln, Austria 2 Biopure Referenzsubstanzen GmbH, Technopark 1, 3430 Tulln, Austria 3 Christian Doppler Laboratory for Mycotoxin Research, Center for Analytical Chemistry, Department for Agrobiotechnology (IFA-Tulln), University of Natural Resources and Applied Life Sciences, Vienna, Konrad Lorenz Str. 20, A-3430 Tulln, Austria 13 C 24 -T-2 Toxin O Stable 13 C Isotope Labeled Mycotoxin Calibrants* The mass spectrometric detection of mycotoxins in analytical chemistry is a very powerful tool. Nowadays, so called LC-MS/MS based multi-mycotoxin analysis methods allows the determination of more than 100 toxins in single run*. However, interferences from matrix components lead to a different ionization of the analyte in a sample in comparison of pure standard calibrants and hence results in different signal intensity. This so called “matrix effect” limits the methods using a mass spectrometer as detector for liquid chromatography. “Matrix effects” can be overcome by adding an internal standard (IS) to the sample, which behaves similar to the analyte and therefore can both correct recovery losses during the sample preparation process and ion suppression effects in the MS source. Stable isotope-labeled analogs of natural mycotoxins provide the best IS for these toxins. However, it should be noted that deuterated compounds still run the risk of H/D exchange in protic solvents and retention time shifts relative to the natural toxin. Moreover, partially labeled toxins frequently contain considerable amounts of “lighter” isomers, leading to mass peaks that interfere with natural toxin isotopes. Therefore, fully 13 C- substituted compounds can be regarded as the best standard for quantification by LC–MS/MS based methods. *Sulyok M, Krska R, Schuhmacher R, Food Addit Contam. 24, (2007) We thank the Christian Doppler Society for their financial support Correspondence should be addressed to: Georg Mitterer ROMER LABS Division Holding GmbH, Technopark Tulln, Austria Full scan MS spectra of ( 13 C 15 )-DON (Biopure) showing the isotopic distribution (blue line). Overlayed is the isotopic pattern of natural occuring DON (red line). The use of fully 13 C isotope labeled mycotoxin internal standards can correct fluctuations that may occur during extraction, clean-up, separation and ionization of the sample. Therefore, isotope labeled mycotoxins are well suited for performing a fast and accurate LC-MS analysis of mycotoxins. Fully 13 C- substituted compounds can be regarded as the best internal standard for quantification of analytes by MS based methods. Determination of the suitability of the labeled DON IS using stable isotope dilution mass spectrometry*: 2.) Comparison of recovery functions for a blank maize extract spiked with DON ( µg/kg, 7 levels, 3 per level) and 250 µg/kg IS.. 1.) Measured DON concentrations of matrix reference materials without cleanup. Results were evaluated with external (yellow colums) and internal calibration (blue colums). Certified values are shown with horizontal lines The extracts were purified with Mycosep® 225 (RomerLabs) clean-up columns before measured with HPLC-MS Recovery without IS: 76% Full scan MS spectra of sodium adducts of ( 13 C 24 )-T-2 toxin showing the isotopic distribution (blue line). Overlayed is the isotopic pattern of sodium adducts of the natural occuring T-2 toxin (red line). Determination of the suitability of the labeled T-2 toxin as IS using stable isotope dilution mass spectrometry*: The comparison of the recovery functions shows an overestimation of approx 40%, if no IS was used (ion enhancement). Additionally blank maize was also spiked with T-2 toxin ( µg/kg, 8 levels, 3 per level) and IS (250 µg/kg). Maize is one of the cereals which creates the highes matrix interferences. Also here an overestimation (+50%) was observed, if no IS was used. Conclusion *Häubl G, Berthiller F, Krska R, Schuhmacher R., Anal Bioanal Chem. 384, (2006).,Häubl G, Berthiller F, Rechthaler J, Jaunecker G, Binder EM, Krska R, Schuhmacher R., Food Addit Contam. 23, (2006). *Häubl G, Berthiller F, Hametner C, Rechthaler J, Jaunecker G, Freudenschuss M, Krska R, Schuhmacher R., Anal Bioanal Chem. 389, (2007) 13 C 15 -Deoxynivalenol (DON) The Use of Fully Stable Isotope Labeled Mycotoxins as Internal Standards for Mycotoxin Analysis with LC-MS/MS Component Conc. (μg/mL) Solvent Unit of Issue Cat. No. U-[ 13 C 15 ]-Deoxynivalenol 25acetonitrile1.2 mL U-[ 13 C 17 ]-3-Ac-DON 25acetonitrile1.2 mLILM006 U-[ 13 C 17 ]-Aflatoxin B1 0.5acetonitrile1.2 mLILM010 U-[ 13 C 17 ]-Aflatoxin B2 0.5acetonitrile1.2 mLILM011 U-[ 13 C 17 ]-Aflatoxin G1 0.5acetonitrile1.2 mLILM012 U-[ 13 C 17 ]-Aflatoxin G2 0.5acetonitrile1.2 mLILM013 U-[ 13 C 17 ]-Mycophenolic acid 0.5acetonitrile1.2 mLILM014 U-[ 13 C 18 ]-Zearalenone 25acetonitrile1.2 mLILM009 U-[ 13 C 20 ]-Ochratoxin A 10acetonitrile1.2 mLILM007 U-[ 13 C 22 ]-HT-2 Toxin 25acetonitrile1.2 mLILM008 U-[ 13 C 24 ]-T-2 Toxin 25acetonitrile1.2 mL U-[ 13 C 34 ]-Fumonisin B1 25 acetonitrile/ water 1.2 mLILM003 U-[ 13 C 34 ]-Fumonisin B2 10 acetonitrile/ water 1.2 mLILM004 U-[ 13 C 34 ]-Fumonisin B3 10 acetonitrile/ water 1.2 mLILM005 U-[ 13 C 15 ]-Nivalenol25acetonitrile1.2 mL ILM ML U-[ 13 C 7 ] -Patulin25acetonitrile1.2 mL ILM ML U-[ 13 C 22 ]-Roquefortine C25acetonitrile1.2 mL ILM ML U-[ 13 C 18 ]-Sterigmatocystin25acetonitrile1.2 mL ILM ML * Available at