GTK Controls and Safety Thermal results with the ceramic heater Kaitlin Howell, Georg Nüßle, Paolo Petagna,

Slides:



Advertisements
Similar presentations
BeginningNext SlideBack End Program AVADAL 1 of 21 SK-1 Roller Apron Segment Overview.
Advertisements

WP4 Organic crystal deposition Mojca Jazbinsek Rainbow Photonics AG SOFI meeting Karlsruhe
Daikin Altherma™ Troubling Shooting
1 Ann Van Lysebetten CO 2 cooling experience in the LHCb Vertex Locator Vertex 2007 Lake Placid 24/09/2007.
E1 – Electrical Fundamentals
1 ASSEMBLY NOTES 1.Specifications Build according to IPC 6012 class 2 Standards 2.THIS DEVICE IS SUSEPTABLE TO DAMAGE BY ESD – Use appropriate ESD precautions.
Heating Control Devices
Developed by Niels Bogh March Objective At the end of the class you will be able to explain the differences of the three main types of flame safety.
© Blue Graphics Concept Sauer-Danfoss START-UP PROCEDURE PROPEL PUMP Instruction Sauer-Danfoss Belgium – T. Van Mossevelde.
Antilock Brake, Traction Control, and Stability Control Systems
STARLight PDR 3 Oct ‘01 G.1.1 Rashid STARLight STARLight Thermal Tahir Rashid STARLight Mechanical Engineer (734)
MICE Hydrogen System Implementation Tom Bradshaw Elwyn Baynham Iouri Ivaniouchenkov Jim Rochford.
GTK WG Meeting May 24 th 2011 Status of Microchannel Cooling - Paolo Petagna 1/9 PH-DT Status of Microchannel Cooling J. Daguin (CERN PH/DT) A. Mapelli.
GTK Cooling Summary of frame and cooling plate Shear tests Alessandro Mapelli Michel Morel Jerome Noel Georg Nüßle Paolo Petagna Giulia Romagnoli GigaTracKer.
Theodore Todorov Pixel mechanics november 8th Inner detector upgrade / IBL Activities on cooling LAPP LAPP team Jacky Ballansat, Patrick.
– GTK Working Group Meeting – GTK Cooling: Status of the Micro-Channel Option Feb 2 nd /21 GTK COOLING: STATUS OF THE MICRO-CHANNEL OPTION Paolo.
GTK WG Meeting April 5 th 2011 Update on Microchannel Cooling - Paolo Petagna 1/15 PH-DT Update on Microchannel Cooling J. Daguin (CERN PH/DT) A. Mapelli.
Velo Module 0 minus minus Paula Collins. Investigating Module 0 thermal performance Baseline module design combines elements of different CTE (and Young’s.
By Carlin Bright. Electricity The flow of electrons in a conductor.
L 17 - Thermodynamics [2] Today’s topics –Practical thermal effects –Devices for temperature measurement –Mechanisms of heat transfer Science dealing.
Settings & Adjustments. Settings & Adjustments.
17/06/2010UK Valencia RAL Petals and Staves Meeting 1 DC-DC for Stave Bus Tapes Roy Wastie Oxford University.
26 April 2013 Immanuel Gfall (HEPHY Vienna) Belle II SVD Overview.
NA62-GTK special meeting on cooling options
NA62 – GTK Cooling Station 1 Main characteristics Fluid: C 6 F 14 (fluorocarbon) Operating temperature: -30 °C ÷ -10°C Temperature precision: ±1 K Temperature.
CHAPTER Electronic Transmission Controls 27 Copyright © 2016 by Pearson Education, Inc. All Rights Reserved Advanced Engine Performance Diagnosis, 6e James.
LHCb VELO Meeting LHCb VELO Cooling System Bart Verlaat (NIKHEF) 25 February 2003.
FVTX Review, November 17th, FVTX Mechanical Status: WBS 1.6 Walter Sondheim - LANL Mechanical Project Engineer; VTX & FVTX.
Interconnection in IC Assembly
Thermal Control System. The Three Mechanisms of Heat Transfer Conduction - The transfer of heat through a solid –Interface Heat Exchangers –Cold plates.
Update on Micro Channel Cooling Collaboration Meeting , G. Nüßle.
Vacuum Studies of LHCb Vertex Locator Sensors Gwenaëlle Lefeuvre, Ray Mountain, Marina Artuso Department of Physics, Syracuse University Abstract : The.
Microchannel cooling Alessandro Mapelli CERN PH-DT EPFL-LMIS4 Reporting on behalf of D. Bouit, J. Daguin, L. Kottelat, J. Noel, P. Petagna – CERN PH-DT.
Report on testing Snake2 u-channel. P. Jalocha & J. Buytaert. 8 June 2015.
A.Cheremukhin (JINR, Dubna) CMS Preshower PRR, July 5-6, 2001, CERN1 Micro-module assembly -  -module elements - alignment of the silicon sensors to the.
Lab Activities: Chamber Baking & Mixing Station Flushing Claudio Curtis Dan PPS meeting 22 June, 2011.
Vessel dimensions GTK assembly carrier Electrical connections Cooling pipes integration Vessel alignment with the beam Next steps Conclusion 3/23/20102electro-mechanical.
Cooling of GEM detector CFD _GEM 2012/03/06 E. Da RivaCFD _GEM1.
Date 2007/Sept./12-14 EDR kick-off-meeting Global Design Effort 1 Cryomodule Interface definition N. Ohuchi.
GTK GAS COOLING SYSTEM Marco Statera, Vittore Carassiti, Ferruccio Petrucci, Luca Landi, Stefano Chiozzi, Manuel Bolognesi NA62 - GTK working group meeting.
GTK GAS COOLING SYSTEM Marco Statera, Vittore Carassiti, Ferruccio Petrucci, Luca Landi, Stefano Chiozzi, Manuel Bolognesi NA62 - GTK working group meeting.
Microchannel Cooling D. Bouit, J. Daguin, A. Jilg, L. Kottelat, A. Mapelli, J. Noel, P. Petagna, G. Romagnoli – CERN PH-DT K. Howell – Georges Mason University.
Origami and Cooling 24th September 2012 C. Irmler (HEPHY Vienna) Joint PXD and SVD Meeting Göttingen.
Chip Scale Atomic Clock Contact Info: Captain Ruiz Perez (281) John Merk (617) Paige McClung (281)
Summary of Presentation 1. Tolerances i. Vertical tolerances on BPMs (rf-BPM: ± 0.2μm, user BPMs: ±0.1μm, and X-BPMs: ± 0.1μm) ii. Tolerances on magnets’
Copyright © 2017 by Pearson Education, Inc. All Rights Reserved Automotive Brake Systems, 7e James D. Halderman Automotive Brake Systems CHAPTER ABS Components.
Automotive Heating And Air Conditioning
Automotive Heating And Air Conditioning
2016/12/6 Yasuhiro R&D status of a gas-compressor based 2-phase CO2 cooling system for FPCCD vertex detector 2016/12/6 Yasuhiro Sugimoto.
Feedback on transfer line sizing and flow calculations for UT
Installation of the T600 at Fermilab
UK Knowledge of Pipe Bending and Pressure Testing Martin Gibson (RAL) Pipe bending by Ian Lancaster University Connector welding by.
Design of the thermosiphon Test Facilities 2nd Thermosiphon Workshop
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
NA62 - GTK Procedure to switch ON/OFF the Cooling Plant version 0
Micro-channel Cooling
CALICE: Thermal, Mechanical and Assembly issues
Microfluidic devices for thermal management
Soldering process 1 Add the soldering material on the soldering pad of speaker in order to solder the wire on the speaker.
Liquid Gasket Suported by.
Re-circulating CO2 Test System
By: JAGDEEP SANGWAN Refrigeration Basics 101.
BONDING The construction of any complicated mechanical device requires not only the machining of individual components but also the assembly of components.
SNS PPU Cryomodule Instrumentation
The Basic Bulb Bulb uses electrical current to produce light.
Presentation transcript:

GTK Controls and Safety Thermal results with the ceramic heater Kaitlin Howell, Georg Nüßle, Paolo Petagna,

Slow Controls / Safety December 2, 2011GTK Cooling Meeting2 EventEffectReaction Failure ASIC8 seconds until temperature stability (temp. liquid) No intervention for cooling needed Hydraulic FailureNo mass flow, temperature rises with 2.3°C/s Signal to power off ASICS Total Power Failure Temperature rises with 0.1°C/s No danger, module will slowly reach room temperature LeakagePollute vacuum in beamline Signal to close safety valves in beam line before and after GTK station

GTK Module Failure Scenarios December 2, 2011GTK Cooling Meeting3 Possible FailurePrevention / Check Geometry imperfections during microfabrication Hydraulic test to determine the pressure drop / mass flow characteristic NanoPort failure, bad gluingHydraulic test with 1.5 times nominal mass flow, Nanoports are rated to 35bar and we tested them up to 70 bar Bad thermal contact after gluing of sensor assembly and cooling plate Pass/fail hydraulic test with thermal camera (red lamp as heat source) Damage during mounting of sensor assembly and cooling plate Electric and hydraulic test of functionality after mounting onto PCB and wire bonding Misalignment between flange and sensor Document will accompany each module and contains the position of the sensor in respect to the flange

NanoPort Connectors December 2, 2011GTK Cooling Meeting4 NanoPort Assemblies are developed to provide consistent fluid connections for Lab-on-a-Chip devices. These fittings bond easily to chip: once attached, NanoPort connections withstand pressures up to 103 bar (35bar in our case). NanoPorts will adhere to silicon, quartz and glass, and they will handle 0.17 N-m to 0.68 N-m of torque, depending on the substrate (typical fittings require only 0.03 – 0.11 N-m to tighten). NanoPort components are made of inert, biocompatible PEEK™ polymer and perfluoroelastomer. And the design of these products eliminates the risk of adhesive contamination in the fluid path. NanoPort connections add no additional volume to a fluid path — eliminating dead volume normally associated with chip-based connections.

Stress cycles on Cool Assembly December 2, 2011GTK Cooling Meeting5

GTK Station replacement December 2, 2011GTK Cooling Meeting6 View from the cooling: Replacement of one module is estimated to take ca. 2h Cooling power can be provided within minutes after reconnection (cooling plant continues to run during replacement) Dominated by external factors: Access time after beam stop Reconnection of Electronics Reestablish vacuum