FITPix – Timepix Test D07-0108 Mario Iván MARTÍNEZ Eduardo MORENO 1.

Slides:



Advertisements
Similar presentations
STAR Pixel Detector Phase-1 testing. 22 Testing interrupted LBNL-IPHC 06/ LG Lena Weronika Szelezniak born on May 30, 2009 at 10:04 am weighing.
Advertisements

The ATLAS Pixel Detector - Introduction -
AUTOMATIC TESTING OF MEDIPIX WAFERS Developing systems to measure Medipix chips Richard Plackett - CERN – April 2nd.
STATUS OF MEDIPIX-3, PLANS FOR TIMEPIX-2 X. Llopart.
Developing the Timepix Telescope Planning a Future Timepix Telescope Richard Plackett – VELO Testbeam Meeting CERN, 7th October 09.
Ryan Badman, M. Artuso, J. Wang, Z. Xing July 7 th, 2010 TIMEPIX Characterization with test pulses with the Syracuse test stand.
New data Threshold angle – 1-pixel – ALL 2-pixel – Balance 2-pixel – (all-pixel) Cluster angle HV scan – Perpendicular track – 10 degrees.
1 QED In Vivo USB Input Output Box configuration This tutorial contains a number of instructions embedded in a great deal of explanation. Procedures that.
Status and outlook of the Medipix3 TSV project
MEDIPIX3 TESTING STATUS R. Ballabriga and X. Llopart.
Institute of Experimental and Applied Physics Czech Technical University in Prague 11th December 2007 Michal Platkevič RUIN Rapid Universal INterface for.
Mathieu Goffe EUDET JRA1 meeting, DESY Wednesday 30 January 2008 IPHC, 23 rue du Loess BP 28, 67037, Strasbourg Cedex 02, France.
Mass production testing of the front-end ASICs for the ALICE SDD system L. Toscano a, R. Arteche Diaz b,d, S. Di Liberto b, M.I. Martínez a,c, S.Martoiu.
-1- Current Telescope Strengths High resolution (~2.5um) Adaptability Ease of use – Currently borrowed by SPS collimator group Weaknesses Small number.
Development of Readout ASIC for FPCCD Vertex Detector 01 October 2009 Kennosuke.Itagaki Tohoku University.
Calibration, simulation and test-beam characterisation of Timepix hybrid-pixel readout assemblies with ultra-thin sensors International Workshop on Future.
In-Beam PET Status Report -- TPS. 2 TPS project PET monitoring prototype 2D view of the FOV coverage of the 4+4 modules Use of 4 modules vs. 4 modules.
FPIX_flip_chip_test module calibration tests November 14 th 2012.
Silicon Sensor with Readout ASICs for EXAFS Spectroscopy Gianluigi De Geronimo, Paul O’Connor Microelectronics Group, Instrumentation Division, Brookhaven.
Readout ASIC for SiPM detector of the CTA new generation camera (ALPS) N.Fouque, R. Hermel, F. Mehrez, Sylvie Rosier-Lees LAPP (Laboratoire d’Annecy le.
1 Pixel readout for a TPC LCWS 2010 – Tracking TPC R&D session 27 March 2010 Jan Timmermans On behalf of the Bonn/CERN/Freiburg/Nikhef/Saclay groups.
Status of the compression/transmission electronics for the SDD. Cern, march Torino group, Bologna group.
C.Schrader; Oct 2008, CBM Collaboration Meeting, Dubna, Russia R/O concept of the MVD demonstrator C.Schrader, S. Amar-Youcef, A. Büdenbender, M. Deveaux,
VI th INTERNATIONAL MEETING ON FRONT END ELECTRONICS, Perugia, Italy A. Dorokhov, IPHC, Strasbourg, France 1 NMOS-based high gain amplifier for MAPS Andrei.
Imaging and spectroscopic performance studies of pixellated CdTe Timepix detector Dima Maneuski Vytautas Astromskas, Erik Fröjdh, Christer Fröjdh, Eva.
Leo Greiner TC_Int1 Sensor and Readout Status of the PIXEL Detector.
A. Chaus, D. Attie, P. Colas, M. Titov CEA Saclay, Irfu/SPP, France Ingrid OUTLINE: OUTLINE:  “Octopuce” Uniformity Studies in the Laboratory  DESY Test-Beam.
Performance limits of a 55  m pixel CdTe detector G.Pellegrini, M. Lozano, R. Martinez, M. Ullan Centro Nacional de Microelectronica, Barcelona, 08193,
Energy calibration of the threshold of Medipix for ATLAS Céline Lebel Université de Montréal presenting for the Institut of Experimental.
Update on Micron productions - Comparison of AC & DC coupled devices - Marko Milovanovic*, Phil Allport, Gianluigi Casse, Sergey Burdin, Paul Dervan, Ilya.
MX-10: Pixel Particle Detector V.Viswanathan, S.Martinek, M.Honig, P.Hubner Dr.Vijayaragavan VISWANATHAN 27/10/2013 IEEE-NSS: New Detector.
Test Setup for FE-I3 single chips / modules, FE-I4_proto1 and for full scale FE-I4 Marlon Barbero, Bonn.
1 The Silicon TPC System EUDET Extended SC meeting 31 August 2010 Jan Timmermans NIKHEF/DESY.
Sensor testing and validation plans for Phase-1 and Ultimate IPHC_HFT 06/15/ LG1.
Anatoli Romaniouk TRT Test manual Some important information p. 2-3Some important information p. 2-3 Noise studies p.4-7Noise studies p.4-7 Operation with.
Project Multi-Touch Albert You Aditya Mittal Paul Ferrara Jim Wallace.
Noise and Data Errors Nominal Observation for “1” Nominal Observation for “0” Probability density for “0” with Noise Probability density for “1” with Noise.
FE-I4 irradiated chip tests at low temperature M. Menouni, P. Breugnon, A. Rozanov (CPPM - Aix-Marseille Université)
Progress with GaAs Pixel Detectors K.M.Smith University of Glasgow Acknowledgements: RD8 & RD19 (CERN Detector R.&D. collaboration) XIMAGE (Aixtron, I.M.C.,
J. Alozy, S. George, F.Murtas, M. Silari 1 CERN GEMPIX detectors as hadron therapy beam monitors and radioactive waste detectors GEMPIX construction.
NI Big Physics Summit CERN
Status report Pillar-1: Technology. The “Helmholtz-Cube” Vertically Integrated Detector Technology Replace standard sensor with: 3D and edgeless sensors,
ECE 101 Exploring Electrical Engineering Chapter 7 Data Acquisition Herbert G. Mayer, PSU Status 11/30/2015 Derived with permission from PSU Prof. Phillip.
The medipix3 TSV project
Equalization of Medipix2 imaging detector energy thresholds using measurement of polychromatic X-ray beam attenuation Josef Uher a,b, Jan Jakubek c a CSIRO.
Medipix3 chip, downscaled feature sizes, noise and timing resolution of the front-end Rafael Ballabriga 17 June 2010.
NOISE MEASUREMENTS ON CLICPIX AND FUTURE DEVELOPMENTS Pierpaolo Valerio.
NEWS FROM MEDIPIX3 MEASUREMENTS AND IMPACT ON TIMEPIX2 X. Llopart CERN.
Comparison of the AC and DC coupled pixels sensors read out with FE-I4 electronics Gianluigi Casse*, Marko Milovanovic, Paul Dervan, Ilya Tsurin 22/06/20161.
E.Gushchin,S.Filippov(INR,Moscow) 16 April 2008Calo commissioning meeting CERN PS/SPD LED monitoring system status General status LED signal is used for.
Update on simulation and sensor procurement Mathieu Benoit.
Electrical Tests of Modules and Ladders Markus Friedl (HEPHY Vienna) 2 October 2014.
Week 22: Schematic Week 23-Week 27: Routing Gerber files have been available since 9th July 1st prototype: – PCB manufacturer: supervised by KIT – Cabling:
Study of the Radiation Damage of Hamamatsu Silicon Photo Multipliers Wander Baldini Istituto Nazionale di Fisica Nucleare and Universita’ degli Studi di.
e- and h+ (with leakage current compensation up to ~2nA/pixel)
DEVELOPMENT OF PIXELLATED SEMICONDUCTOR DETECTORS FOR NEUTRON DETECTION Prof. Christer Fröjdh Mid Sweden University.
Progress with GaAs Pixel Detectors
Setup for automated measurements (parametrization) of ASD2 chip
on behalf of the AGH and UJ PANDA groups
CTA-LST meeting February 2015
Pixel panels and CMOS Read-out electronics
Strawman module design
Status of the Merlin Readout System
TIMEPIX TESTBEAM TELESCOPE FOR AIDA
Σ-D Analog to Digital Converter for CMOS Image Sensors Nonu Singh (RIT, MicroE Co-Op) Background After fabricating an imaging sensor it needs to be characterized.
Web Document Image Analysis (OCR) Servers
Status of n-XYTER read-out chain at GSI
Test Beam Measurements october – november, 2016
BESIII EMC electronics
TPC chamber for Medipix2/TimePix
Presentation transcript:

FITPix – Timepix Test D Mario Iván MARTÍNEZ Eduardo MORENO 1

First chip settings Bias Voltage (we used 100 V) Digital test of pixels DAC’s scan 2

Threshold (THL) equalization Timepix amp. discrimination level can be chosen to filter out noise. A single THL level can be set common to all 65,536 pixels – One wants to put this above the noise level. Typically 40 THL counts ≈ 100 e- Every pixel has a different noise level – Gaussian distributed – 4-bit DAC to adjust the “noise” (actually, the amp’s output DC level) level individually Pixelman feature exists to automatically find the noise level and adjust this DAC for each pixel 3

Noise distribution before and after THL equalization Highest DAC adjust. mean = THLcounts std. dev. = 9.67 Lowest DAC adjust. mean = THLcounts std. dev. = 9.58 Equalized adjust. mean = THLcounts std. dev. =

DAC’s adjustment distribution after equalization 5

Materials Timepix chip D0-W0108 Radioactive sources – Iron: 55 Fe – Americium: 241 Am – Strontium: 90 Sr Software – MAFalda v 2.1 – Pixelman ( ) Hardware – FITPix (Medipix/TimePix USB 2.0 v.2.3, Firmware 3) – Timepix (D07-W0108) 300  m thick 6

Acquisition parameters 20 o C 10 milliseconds per frame 100,000 frames Operation mode Time Over Threshold Bias voltage 100V Distance source-sensor 2 centimeters 7

Tested on Desktop, Windows 7 Laptop, Windows 7 Laptop, Mac Virtual Machine, Linux Problems with usb connection in Mac and Virtual machine 8

Measurements 9

Contrast To observe pixels’ noise (individuate noisy ones) 100,000 frames Acquisition mode Time Over Threshold Time per frame 10 milliseconds 10

High noise (bad bonding?) 11

Contrast 12

zoom for each “quadrant” 13

zoom to inner “good” area 14

Clusters Single Double Triple Quad 15

90 Fe 16

ToT distribution of single-pixel clusters 17

ToT distribution of single- and double- pixel clusters 18

Number of clusters vs. total ToT per frame 19

241 Am 20

Single-pixel clusters 21

ToT distributions for different cluster sizes 22

Number of clusters vs. total ToT per frame 23

Conversion Energy to ToT 24

Aplicaciones a física médica Imágenes bidimensionales con rayos X Imágenes tomográficas con rayos X Dosimetría con radiación dispersa Estudio de fragmentación de núcleos en hadroterapia 25

Medipix 3 TSV layout Timo Tick - Status and outlook of the Medipix 3 TSV project 26 Complete map Metrology boxes Front side Electrical tests area Back side Electrical tests area

Timo Tick - Status and outlook of the Medipix 3 TSV project 27 Modular unit for imaging applications: NxM matrix of detector tiles in a module NxM matrix of modules BGA bonded to a ceramic multilayre board