SiPM Workshop EU-FP7(HP3), Vienna, 16 Feb. 2013 F.G. H.O. Study of scintillator detectors time resolution with different SiPM readout on T10 test beam.

Slides:



Advertisements
Similar presentations
Liverpool Group presentation 22/07/2009
Advertisements

T-979: SiPM Time Resolution with DRS4 Readout Anatoly Ronzhin, Fermilab, AEM March 12, 2012 Team: Mike Albrow, Sergey Los, Pasha Murat, Erik Ramberg, Fermilab.
Scintillator based muon upgrade / BELLE Super B Factory Workshop In Hawaii Jan 2004, Honolulu, Hawaii 1.Scintillator strip option 2.Geiger photodiodes.
Design and test of a high-speed beam monitor for hardon therapy H. Pernegger on behalf of Erich Griesmayer Fachhochschule Wr. Neustadt/Fotec Austria (H.
Photon detection Visible or near-visible wavelengths
The Transverse detector is made of an array of 256 scintillating fibers coupled to Avalanche PhotoDiodes (APD). The small size of the fibers (5X5mm) results.
Report on SiPM Tests SiPM as a alternative photo detector to replace PMT. Qauntify basic characteristics Measure Energy, Timing resolution Develop simulation.
GLD Calorimeter Status Oct 学術創成会議 S. Uozumi Shinshu University FJPPL meeting held at the end of September. Preparation underway toward the ECAL.
PSD upgrade: Ar-present and Xe-future 1.- Status of the PSD upgrade 2.- PSD performance after upgrade 3.- Problems during the Ar-run 4.- Future scenarios.
Status of Projectile Spectator Detector A.Kurepin (Institute for Nuclear Research, Moscow) I. Introduction to PSD. II. Conception and design. III. Development.
FLC Group Test-beam Studies of the Laser-Wire Detector 13 September 2006 Maximilian Micheler Supervisor: Freddy Poirier.
SiPM: Development and Applications
Characterization of the static and dynamic
The MPPC Study for the GLD Calorimeter Readout Introduction Measurement of basic characteristics –Gain, Noise Rate, Cross-talk Measurement of uniformity.
Применение MAPD (Zecotek) в адронных калориметрах и многоканальных времяпролетных системах в экспериментах по релятивистской ядерной физике Ф.Ф.Губер,
“End station A setup” data analysis Josef Uher. Outline Introduction to setup and analysis Quartz bar start counter MA and MCP PMT in the prototype.
Scintillator tile-SiPM system development for CALICE Engineering AHCAL Prototype Michael Danilov, ITEP & CALICE LCWS10 Beijing March 2010 Outline New scintillator.
PANDA Anton A. Izotov, Gatchina A.A.Izotov, Gatchina, PANDA Forward TOF Walls. Side TOF walls in dipole Magnet SiPM/PMT187.
1 NIU Integrated Readout Layer Kurt Francis NICADD Northern Illinois University March 19, 2014.
Development of TOP counter for Super B factory K. Inami (Nagoya university) 2007/10/ th International Workshop on Ring Imaging Cherenkov Counters.
Optimization of Detectors for Time of Flight PET Marek Moszyński, Tomasz Szczęśniak, Soltan Institute for Nuclear Studies, Otwock-Świerk, Poland.
MPPC status M.Taguchi(kyoto) T2K ND /7/7.
Takeshi Fujiwara, Hiroyuki Takahashi, Kaoru Fujita, Naoko Iyomoto Department of Nuclear Engineering and Management, The University of Tokyo, JAPAN Study.
The GEM activities at Tsinghua University Zhigang Xiao 1, Yan Huang 1, Rensheng Wang 1, Haiyan Gao 1,2 1 Department of Physics, Tsinghua University 2 Dept.
Status of photon sensor study at Niigata University -- SiPM and MPPC -- Photon sensor mini workshop 05/9/16 University Niigata University.
1 SiPM studies: Highlighting current equipment and immediate plans Lee BLM Quasar working group.
Timing Studies of Hamamatsu MPPCs and MEPhI SiPM Samples Bob Wagner, Gary Drake, Patrick DeLurgio Argonne National Laboratory Qingguo Xie Department of.
1/10/2016Collaboration Meeting Feb 2011 Start Counter 1 Start Counter Update W. U. Boeglin L. Guo E. Pooser Measurements on EJ-212 scintillator bars Attenuation.
CERN September 29, 20041W.H.Trzaska HIP Jyväskylä T0 – TDR 22 nd LHCC meeting; Open Session CERN, September 29, 2004 W.H.Trzaska (for T0 collaboration)
Gain stability and the LYSO beam radiation monitor measurements
FSC Status and Plans Pavel Semenov IHEP, Protvino on behalf of the IHEP PANDA group PANDA Russia workshop, ITEP 27 April 2010.
SiPM for CBM Michael Danilov ITEP(Moscow) Muon Detector and/or Preshower CBM Meeting ITEP
2007 detectors study at CERN 1.SiPM time resolution 2.MAPD S60 3.Blue sensitive MAPD 4.New 16ch board 5.New HV.
Peter Dendooven LaBr 3 and LYSO monolithic crystals coupled to photosensor arrays for TOF-PET Physics for Health in Europe Workshop February 2-4, 2010,
A Brand new neutrino detector 「 SciBar 」 (2) Y. Takubo (Osaka) - Readout Electronics - Introduction Readout electronics Cosmic ray trigger modules Conclusion.
CERN PH MIC group P. Jarron 07 November 06 GIGATRACKER Meeting Gigatracker Front end based on ultra fast NINO circuit P. Jarron, G. Anelli, F. Anghinolfi,
Super-IFR Detector R&D summary Wander Baldini Ferrara, Padova, Roma1 INFN and University on behalf of the superB-IFR group: Ferrara, Padova, Roma1 INFN.
Status of NEWCHOD E.Guschin (INR), S.Kholodenko (IHEP), Yu.Kudenko (INR), I.Mannelli (Pisa), O.Mineev (INR), V.Obraztsov (IHEP), V.Semenov(IHEP), V.Sugonyaev.
Update on works with SiPMs at Pisa Matteo Morrocchi.
Upgrade of the MEG liquid xenon calorimeter with VUV-light sensitive large area SiPMs Kei Ieki for the MEG-II collaboration 1 II.
FTOF Status Anton A. Izotov, Frascati
1 Projectile Spectator Detector: Status and Plans A.Ivashkin (INR, Moscow) PSD performance in Be run. Problems and drawbacks. Future steps.
Silicon Photomultiplier Development at GRAPES-3 K.C.Ravindran T.I.F.R, OOTY WAPP 2010 Worshop On behalf of GRAPES-3 Collaboration.
GSI 9Feb09 NMI3 – Integrated Infrastructure Initiative for Neutron Scattering and Muon Spectroscopy, Joint Research Activity (JRA8): MUON-S. Contract:
Study of the MPPC for the GLD Calorimeter Readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group Kobe Introduction Performance.
M.Taguchi and T.Nobuhara(Kyoto) HPK MPPC(Multi Pixel Photon Counter) status T2K280m meeting.
Study of the Radiation Damage of Hamamatsu Silicon Photo Multipliers Wander Baldini Istituto Nazionale di Fisica Nucleare and Universita’ degli Studi di.
Beam detectors in Au+Au run and future developments - Results of Aug 2012 Au+Au test – radiation damage - scCVD diamond detector with strip metalization.
FP7 Kick-off Workshop on G-APDs GSI 9-10 Feb A.Wilms H.Orth G-APD Avtivities at GSI G-APD Activities at GSI Title Present instrumentation for the.
1 The Scintillation Tile Hodoscope (SciTil) ● Motivation ● Event timing/ event building/ software trigger ● Conversion detection ● Charged particle TOF.
IFR Detector R&D status
Activities at SMI/Vienna in testing the performance of SiPMs
Prospect of SiPM application to TOF in PANDA
Performance of scintillation pixel detectors with MPPC read-out and digital signal processing Mihael Makek with D. Bosnar, V. Gačić, L. Pavelić, P. Šenjug.
Activities and Results from PNPI GATCHINA
The PSD at Pb-Pb run PSD drawbacks at Ar beam
Scintillation Detectors in High Energy Physics
HELIX time of flight system electronics concepts
PSD Front-End-Electronics A.Ivashkin, V.Marin (INR, Moscow)
Claudio Cerri, Riccardo Fantechi, Luigi Di Lella
大強度
Department of Physics and Astronomy,
MEG実験アップグレードに向けたSiPMを用いた ポジトロン時間測定器の研究開発
Времяпролетный детектор PANDA
Development of hybrid photomultiplier for Hyper-Kamiokande
Forward TOF Anton A. Izotov, PNPI.
Test Setup SiPM Hamamatsu S C Pixel size( 25um)
R&D of MPPC in kyoto M.taguchi.
CLAS 12 Status of the test bench Calculation of the time resolution
The MPPC Study for the GLD Calorimeter Readout
Presentation transcript:

SiPM Workshop EU-FP7(HP3), Vienna, 16 Feb F.G. H.O. Study of scintillator detectors time resolution with different SiPM readout on T10 test beam at June The goal of measurements. - Scintillator detectors with different SiPMs readout. - T10 test beam facility. - Results of measured time resolution for different SiPMs readout. - Conclusion F.Guber, A.Ivashkin,V.Marin, INR,Moscow H.Orth, GSI, Darmstadt

SiPM Workshop EU-FP7(HP3), Vienna, 16 Feb F.G. H.O. Goal of the test To measure time resolution and amplitude spectra of scintillator detectors with SiPMs produced by HAMAMATSU, KETEK and ZECOTEK. Dimensions of scintillators are optimized for TOF systems of PANDA experiment at FAIR. Additional test have been done for scintillators optimized for central part of forward CBM TOF, HADES FW….

SiPM Workshop EU-FP7(HP3), Vienna, 16 Feb F.G. H.O. Scintilators – BC-408 Two sample: -28 x 28 x 5 mm -30 x 30 x 10 mm Scintillators have been overlapped by TYVEK Used SiPMs – sensitive area 3 x 3 mm: - PM3350 (KETEK) - MPPC S C (HAMAMATSU) - MAPD-3N (Zecotek) Method of light readout: Scintillator 28 x 28 x 5 mm by two SiPMs from one surface. Scintillator 30 x 30 x 10 mm by two SiPMs from opposite rear surfaces. Scintillator detectors with different SiPMs readout

SiPM Workshop EU-FP7(HP3), Vienna, 16 Feb F.G. H.O. Properties of used SiPMs Active Area 3 x 3 mm 2 Pixel Size 100 x 100 um Number of Pixels 3600 Peak Wavelength 440 nm Operating Voltage 70±10 V Gain MPPC S C (HAMAMATSU) PM3350 (KETEK) Active Area 3 x 3 mm 2 Pixel Size 100 x 100 um Number of Pixels 3600 Peak Wavelength 420 nm Operating Voltage V Gain ~ Active Area 3 x 3 mm 2 Number of Pixels Peak Wavelength nm Operating Voltage ~90 V Gain MAPD-3N (Zecotek)

SiPM Workshop EU-FP7(HP3), Vienna, 16 Feb F.G. H.O. Amp PMT quartz beam Amp SiPM TDC Start Stop1 Stop2 LeCroy 2228A ADC LeCroy 2249A Hamamatsu R7525  t =60ps D DD Leading Edge DiscrimonatorC AEN Mod.84 Thresh=50 mV Experimental Setup

SiPM Workshop EU-FP7(HP3), Vienna, 16 Feb F.G. H.O. Two different amplifiers were used Differential amplifier provided by H.Orth (positive overshoot is visible) Amplifier with Pole Zero Compensation The time and amplitude resolutions for PZC amplifier are slightly better and the measurements were done for second type.

SiPM Workshop EU-FP7(HP3), Vienna, 16 Feb F.G. H.O. Test results for scintillators with HAMAMATSU MPPC S C

SiPM Workshop EU-FP7(HP3), Vienna, 16 Feb F.G. H.O. Amplitude spectra for one of MPPC at large side MPPC1 MPPC2 28 mm Time-amplitude walk At present analysis the time resolution was determined for narrow ADC bin to avoid T-A walk t= 5mm

SiPM Workshop EU-FP7(HP3), Vienna, 16 Feb F.G. H.O. Time spectra for MPPCs from large side MPPC1 MPPC2 28 mm  t =173 ps for both MPPC  t =231 ps for single MPPC (T1+T2)/2 Time resolutions were calculated for narrow ADC bin= 40 ch Time resolution of start quartz detector (σ t =60ps) Is taken into account t= 5mm

SiPM Workshop EU-FP7(HP3), Vienna, 16 Feb F.G. H.O. Amplitude spectrum for MPPC at small side Time resolution were calculated for narrow ADC bin ~ 40 ch to avoid T-A walk MPPC1 MPPC2 28 mm Amplitude at small side is ~1.5 times larger comparing to large side t= 5mm

SiPM Workshop EU-FP7(HP3), Vienna, 16 Feb F.G. H.O. Time spectra for MPPCs at small opposite sides MPPC1 MPPC2 28 mm Calculation were done for narrow ADC bin= 40 ch (T1+T2)/2  t =148 ps for single MPPC  t =126 ps for both MPPC t= 5mm

SiPM Workshop EU-FP7(HP3), Vienna, 16 Feb F.G. H.O. Spectra for MPPCs from scintillator 30 x 30 x10 mm t = 10 mm  t =170 ps for single MPPC  t =115 ps for both MPPC (T1+T2)/2 MPPC1 MPPC2 30 mm Calculation were done for narrow ADC bin= 40 ch

SiPM Workshop EU-FP7(HP3), Vienna, 16 Feb F.G. H.O. Test results for scintillators with PM3350 (KETEK)

SiPM Workshop EU-FP7(HP3), Vienna, 16 Feb F.G. H.O. Amplitude spectra for KETEK SiPMs at small side Time-amplitude walk Time resolution was calculated for narrow ADC bin to avoid T-A walk SiPM1 SiPM2 28 mm t= 5mm

SiPM Workshop EU-FP7(HP3), Vienna, 16 Feb F.G. H.O. Time spectra for KETEK SiPMs at small sides Calculations were done for narrow ADC bin= 50 ch SiPM1 SiPM2 28 mm  t =120 ps for both SiPMs (T1+T2)/2  t =168 ps for single SiPM t= 5mm

SiPM Workshop EU-FP7(HP3), Vienna, 16 Feb F.G. H.O. Time spectra for KETEK SiPMs at small sides for very narrow ADC bin=20 ch Measurement were done for very narrow ADC bin= 20 ch SiPM1 SiPM2 28 mm  t =96 ps for both SiPMs (T1+T2)/2  t =163 ps for single SiPM t= 5mm

SiPM Workshop EU-FP7(HP3), Vienna, 16 Feb F.G. H.O. Test results for scintillators with MAPD-3N

SiPM Workshop EU-FP7(HP3), Vienna, 16 Feb F.G. H.O. Spectra for Zecotek MAPD-3N (T1+T2)/2  t =240 ps for both MAPDs  t =360 ps for single MAPD SiPM1 SiPM2 28 mm t= 5mm

SiPM Workshop EU-FP7(HP3), Vienna, 16 Feb F.G. H.O. Summary A measurements of 28x28x5 mm 3, 28x28x10 mm 3 and 30 x 30 x 10 mm 3 scintillator tiles were performed for a few types of SiPMs. The best time resolution is obtained in case of SiPM position at opposite small sides of the tile. Time resolutions for single Hamamatsu MPPC and KETEK SiPM are very similar and about ps. Averaged time resolution with two SiPM readout is about 120 ps. For very narrow ADC bin widths the time resolution could achieve 100 ps. But it is worser probably for wide ADC range. The effect of time-amplitude walk should be account properly. Further optimization of the measurements is required. Namely, the discriminator threshold, signal amplification, SiPM voltage and noise affect the time resolution.