LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY (LC/MS)

Slides:



Advertisements
Similar presentations
OFFLINE COMPOSITION MEASURING SENSORS
Advertisements

D e t e c t o r s f o r H P L C.
Liquid chromatography coupled with Mass spectroscopy
FC-MS from Teledyne Isco CombiFlash ® a Name You Can Rely On.
Inductively Coupled Plasma Mass Spectrometry or ICP-MS
Mass Spectrometry Inlet system Ion Source Mass Analyzer Ion Detector.
HPLC Coupled with Quadrupole Mass Spectrometry and Forensic Analysis of Cocaine.
Lecture 14 LC-MS Ionization. GC Computer MS GC-MS.
Mass Spectroscopy Mass Spectrometry ä Most useful tool for molecular structure determination if you can get it into gas phase ä Molecular weight of.
Standard Methods for the Examination of Water and Wastewater, 21st Ed
Lecture 8. GC/MS.
Instrumental Chemistry Chapter 11 Atomic Mass Spectrometry.
LC-MS Based Metabolomics. Analysing the METABOLOME 1.Metabolite Extraction 2.Metabolite detection (with or without separation) 3.Data analysis.
Molecular Mass Spectrometry
LC-MS Lecture 7.
LC/MS WORKSHOP IOWA STATE UNIVERSITY Kamel Harrata  Instrument Description  Data Acquisition  Data Processing.
Instant Notes Analytical Chemistry
Mass Spectroscopy 1Dr. Nikhat Siddiqi. Mass spectrometry is a powerful analytical technique that is used to identify unknown compounds, to quantify known.
Gas Chromatography And Mass Spectrometry
Mass Spectrometer Mass spectrometere is a very powerful method to analyse the structure of organic compounds.
B IOCHEMICAL INSTRUMENTAL ANALYSIS -11 Dr. Maha Al-Sedik.
Types of Chromatography Liquid chromatography versus gas chromatography? Applications? Volatile  GC Non-volatile  LC.
Chapter 8 – Mass Spectrometry. Mass Spectrometry The mass spectrometer can be used for: – Quantitative analysis – as a sophisticated and very sensitive.
GCMS: gas chromatography and mass spectrometry
By, Blessy Babu. What is Gas Chromatography?  Gas spectroscopy is a technique used to separate volatile components in a mixture.  It is particularly.
Chemical Analysis. Analytical Techniques When chemical evidence is collected at a crime scene, it must be run through an instrument. These instruments.
By: Thilag.k & Stephen. What is Hpcl??? Hplc or high performance liquid chromatography is the most widely used analytical separation technique. The difference.
Year 12 Chemistry Unit 3 – AOS 1 Chemical Analysis.
Molecular mass spectrometry Chapter 20 The study of “molecular ions” M + e -  M e -
1 Chemical Analysis by Mass Spectrometry. 2 All chemical substances are combinations of atoms. Atoms of different elements have different masses (H =
William Kou Jonathan Mertz. Introduction The field of Mass Spectrometry using Ambient Ionization techniques has grown exponentially since The direct.
Based on ionization of gas phase molecule followed by analysis of the masses of the ions produced. The Mass Spectrum: Graph of ion intensity versus mass-to-charge.
Mass Spectroscopy 1 Mass Spectroscopy (Mass Spec) Applying Atomic Structure Knowledge to Chemical Analysis.
Chemistry Topic: Atomic theory Subtopic : Mass Spectrometer.
Mass Spectrometry Instrumentation: Ionization methods and analyzers.
Capillary Electrophoresis (CE) PHAR Lecture Objectives By the end of the lecture, students should be able to: 1.Illustrate the CE instrumental.
Combining and Choosing Analytical Techniques Chapter 8.
By- Bhavya, Harsh, Harshvardhan, Namrata, Ronit and Vidhatri
Analytical Separations
HPLC – High Performance Liquid Chromatography
LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY
HPLC.
1 Principle  LC-MS is interfacing HPLC system with mass spectrometer.  The difficulty in hyphenation is to transform the solute into gas phase ion. 
Biochemical instrumental analysis - 11 Dr. Maha Al-Sedik 2015 CLS 332.
Chromatography and Instrumentation. Chromatography Separate Analyze Identify Purify Quantify Components Mixture Chromatography is used by scientists to:
Mass Spectrometry Relative atomic masses and the mass of individual isotopes can be determined using a mass spectrometer. The principle behind mass spectrometry.
Chapter 29 Mass Spectrometry. 29 A Principles of mass spectrometry In the mass spectrometer, analyte molecules are converted to ions by applying energy.
LIQUID CHROMATOGRAPHY – MASS SPECTROSCOPY (LC-MS) Presented by Md Akbar Siddiq Khan M.Pharm Nizam College Of Pharmacy Hyderabad - A.P.
Instrumental Analysis
Objective  To develop methods for analysis of compounds in organic aerosol particles Why is this important?  Environmental impact  Alternative fuels.
Methodology of targeted mass spectrometry
Biochemical instrumental analysis - 9 Dr. Maha Al-Sedik 2016 CLS 332.
Mass Spectrometry makes it possible to measure protein/peptide masses (actually mass/charge ratio) with great accuracy Major uses Protein and peptide identification.
Components of Mass Spectrometer
Chem. 133 – 4/13 Lecture.
Mass Spectrometry Obaid M. Shaikh.
HPLC Equipment : Detectors
Metabolomics Part 2 Mass Spectrometry
Mass Spectroscopy. Mass Spectroscopy Mass Spectrometry Most useful tool for molecular structure determination if you can get it into gas phase Molecular.
Lecture 14 LC-MS Ionization.
Instrumental Chemistry
Organic Instrumentation
Lecture 14 LC-MS Ionization.
Mass Spectrometry THE MAIN USE OF MS IN ORG CHEM IS:
M.Prasad Naidu MSc Medical Biochemistry, Ph.D,.
GAS CHROMATOGRAPHY.
CHROMATOGRAPHY.
Mass spectrometry (MS) is an analytical technique that can be used to determine the mass, elemental composition or chemical structure of molecules. Mass.
Suppose we make a new compound containing of C,H, and N
LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY (LC-MS)
Presentation transcript:

LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY (LC/MS) Presented by: R.V.DURGASAI HT.NO: Y12MPH0865 M.Pharm (pharmaceutical analysis) Ist yr NIRMALA COLLEGE OF PHARMACY.

INTRODUCTION Principle: LC/MS is a technique that combines physical separation capabilities of liquid chromatography with mass analysis capability of Mass spectrometry. It is a method that combines separation power of HPLC with detection power of Mass spectrometry. In LC-MS we remove the detector from the column of LC and fit the column to interface of MS. In the most of the cases the interface used in LC-MS are ionization source.

Theory of LC/MS HPLC is a method for separating a complex mixture in to its components. High sensitivity of mass spectroscopy provides the information for identification of compounds or structural elucidation of compounds. Combination of these two techniques is LC-MS As the metabolites appear from the end of the column they enter the mass detector, where the solvent is removed and the metabolites are ionized.

LC-MS System Components Mass spectrometers work by ionizing molecules and then sorting and identifying the ions according to their mass-to-charge (m/z) ratios.

PROBLEMS IN COMBINING HPLC AND MS Liquid phase operation 25 - 50 deg. C No mass range limitations Inorganic buffers 1 ml/min eluent flow is equivalent to 500 ml/min of gas MS Vacuum operation 200 - 300 deg. C Up to 4000 Da for quadrupole MS Requires volatile buffers Accepts 10 ml/min gas flow

MOBILE PHASE The mobile phase is the solvent that moves the solute through out column. General requirements:- (1) Low cost, UV transparency, high purity. (2) Low viscosity, low toxicity, non flammability. (3) Non corrosive to LC system component. Solvent strength and selectivity:- It is the ability of solvent to elute solutes from a column.

COLUMN The use of di-functional or tri-functional silanes to create bonded groups with two or three attachment points leading to phases with higher stability in low or higher pH and lower bleed for LCMS Most widely used columns for LC-MS are:- (1) fast LC column. the use of short column. (15-50mm) (2) Micro LC column. the use of large column. ( 20-150mm)

Sample preparation Sample preparation generally consists of concentrating the analyte and removing compounds that can cause background ion or suppress ionization. Example of sample preparation include:- On Column concentration -to increase analyte concentration. Desalting - to reduce the sodium and potassium adduct formation that commonly occurs in electro spray. Filtration- to separate a low molecular-weight drug from proteins in plasma, milk, or tissue.

INTERFACES LC-MS systems include a device for introducing samples (such as an HPLC )an interface for connecting such device, an ion source that ionizes samples, an electrostatic lens that efficiently introduces the generated ions, a mass analyzer unit that separates ions based on their mass-to-charge (m/z) ratio, and a detector unit that detects the separated ions. In an LC-MS system, however, if the LC unit is simply connected directly to the MS unit, the liquid mobile phase would vaporize, resulting in large amounts of gas being introduced into the MS unit. This would decrease the vacuum level and prevent the target ions from reaching the detector. So interfaces are to be used.

TYPES OF INTERFACES It is difficult to interface a liquid chromatography to a mass-spectrometer cause of the necessity to remove the solvent. The commonly used interfaces are:- (1) Electrospray ionization (ESI) (2) Thermospray ionization (TSI) (3) Atmospheric pressure chemical ionization (APCI) (4) Atmospheric pressure photoionization(APPI)

Electro Spray Ionization (ESI) ESI draws sample solutions to the tip of a capillary tube, where it applies a high voltage of about 3 to 5 kV. A nebulizer gas flows from outside the capillary to spray the sample. This creates a fine mist of charged droplets with the same polarity as the applied voltage. As these charged particles move, the solvent continues to evaporate, thereby increasing the electric field on the droplet surface. When the mutual repulsive force of the charges exceeds the liquid surface tension, then fission occurs. As this evaporation and fission cycle is repeated, the droplets eventually become small enough that the sample ions are liberated into the gas phase

Electro Spray Ionization (ESI) ESI provides the softest ionization method available, which means it can be used for highly polar, least volatile, or thermally unstable compounds.

Atmospheric pressure chemical ionization (APCI) APCI vaporizes solvent and sample molecules by spraying the sample solution into a heater (heated to about 400 °C) using a gas, such as N2. Solvent molecules are ionized by corona discharge to generate stable reaction ions.

Thermospray ionization (TSI) They are of 2 type: a) Real-TSP ionization b) Discharge electrode for external ionization and repeller electrode

Atmospheric pressure photoionization(APPI) The LC eluent is vaporized using a heater at atmospheric pressure. The resulting gas is made to pass through a beam of photons generated by a discharge lamp (UV lamp) which ionizes the gas molecules.

Mass Analyser They deflect ions down a curved tubes in a magnetic fields based on their kinetic energy determined by the mass, charge and velocity. The magnetic field is scanned to measure different ions. Types of mass analyzer:- (1) Quadrapole mass filter. (2) Time of flight (3) Ion trap (4) Fourier transform ion cyclotron resonance (FT-ICR)

Quadrupole Mass Analyzer A Quadrupole mass filter consists of four parallel metal rods with different charges Two opposite rods have an applied + potential and the other two rods have a - potential The applied voltages affect the trajectory of ions traveling down the flight path For given DC and AC voltages, only ions of a certain mass-to-charge ratio pass through the quadrupole filter and all other ions are thrown out of their original path

TOF (Time of Flight) Mass Analyzer TOF Analyzers separate ions by time without the use of an electric or magnetic field. In a crude sense, TOF is similar to chromatography, except there is no stationary/ mobile phase, instead the separation is based on the kinetic energy and velocity of the ions.

Ion Trap Mass Analyzer It uses an electric field for the separation of the ions  by mass to charge ratios. The electric field in the cavity due to the electrodes causes the ions of certain m/z values to orbit in the space.

Fourier transform ion cyclotron resonance (FT-ICR) Uses a magnetic field in order to trap ions into an orbit inside of it. In this analyzer there is no separation that occurs rather all the ions of a particular range are trapped inside, and an applied external electric field helps to generate a signal.

Applications of LC-MS Pharmaceutical Applications: Rapid chromatography of benzodiazepines Identification of bile acid metabolite Biochemical Applications: Rapid protein identification using capillary LC/MS/MS and database searching. Clinical Applications: High-sensitivity detection of trimipramine and thioridazine

Applications of LC-MS Drugs of abuse Food Applications: Identification of aflatoxins in food Determination of vitamin D3 in poultry feed supplements Environmental Applications: Detection of phenylurea herbicides Detection of low levels of carbaryl in food Forensic Applications: illegal substances, toxic agents Explosives Drugs of abuse

Instrumental Methods Of Chemical Analysis By Willard References Instrumental Methods Of Chemical Analysis By Willard Instrumental Methods of Analysis – By Gurdeep Chatwal Textbook of Pharmaceutical Analysis - By Ravi Shankar Instrumental Methods of Analysis - By Skoog. www.impactanalytical.com/lc-ms-analysis.asp www.shimadzu.com/an/lcms/index.html www.enotes.com/topic/Liquid_chromatography-mass_spectrometry www.spectroscopynow.com www.sciencedirect.com Raffaelli A, Saba A. Atmospheric pressure photoionization mass spectrometry. Mass Spectrum Rev. 2003;22:318–31 Google Images