Shape Memory Alloy Thermomechanical Testing ME356 Spring 2016 8 April 2016.

Slides:



Advertisements
Similar presentations
FHM TRAINING TOOLS This training presentation is part of FHM’s commitment to creating and keeping safe workplaces. Be sure to check out all the training.
Advertisements

How does energy transfer through our atmosphere?
CRIMPING Introduction
Next Home Visio2 troubleshooting guide Start the slide show then click Next.
Hydronic Balancing Balancing Valves
Brio 2000 / Brio 2000-M E-Learning Service Manual Rev. 0.0.
temperature system wiring
Refrigerators.
Evaporator Carbon coating. Evaporator Step 1 Check that all switches on control console are to OFF position. Automatic Vacuum Control knob should be.
1 UBC International Training Fund Presents. Tensioning.
Key HVAC Design Concepts. Agenda Discuss relevance of thermal enclosure system to HVAC system. Present the three major steps to design an HVAC system.
Bellow valve (trap&pump) Inside glove box. (Note: Ar glove box is not necessary, if you work with single crystalline organic materials like rubrene that.
Physics 1809 Minilab 2: Heat and Temperature Physics 1809: The Relationship Between Heat and Temperature Purpose Understand how the total energy in a closed.
Metering Devices North Seattle Community College HVAC Program
1 Oil Fuel Line De-aerators What they are, what they do and how to install.
UNIT: Oxy-Acetylene Welding, Brazing, Cutting and Heating
HVACR312 - Refrigeration Metering Devices.
ResQmax Line Deployment Kit -ResQmax Launcher- 5 nozzle protectors -2 Streamline Projectiles- O-ring kit -500’ 3mm line with container- Corrosion block.
CHANGE OF PHASE Matter exists in three common phases: solid, liquid and gas.
Temperature and the Atmosphere. Without heat there is no weather. The most influential factor effecting weather in the atmosphere is heat. The most influential.
American Electrical, Inc. Junction Box / Hookup Box Fast and easy way to make electrical connections An assembled kit – no need to procure and assemble.
DSC instrument design and corresponding experimental methodology.
Product Introduction.
CAPACITORS & RESISTORS. RESISTORS A resistor, like batteries and lights, can also be present in an electrical circuit. A resistor limits the flow of electricity.
AccuMax Multi-Point Injection Mechanics
TRD Emergency Actions for Temperature Control: (1) Heaters On/Off (2) Pump On/Off K. Andeen 20 March 2013.
Micro Practical 3 PRINCIPLE AND WORKING OF AUTOCLAVE Dr. Shahzad Ali Assistant Professor Department of Wildlife and Ecology UVAS, Ravi Campus, Pattoki.
Accessories Planned Maintenance. Types l Humidifiers l Air Cleaners l Heat Recovery Ventilators l Condensate Pumps.
DO NOW: 1.Hand in the field trip brainstorming you wrote on Friday. 2.Take out your microscope Green packets from last week. 3.In your NOTES section of.
Experiment 7. Thermal Expansivity by Dilatometry and Pycnometry The dilatometer and pycnometer used in this experiment are illustrated here. The dila-
I.C. ENGINES Practical No: 1 (17 Mar, 2014). Measurement of Cylinder Pressure If your vehicle has been running roughly or losing power, there may be a.
Air Conditioning Heating Refrigeration
Continue The information provided in this training module covers the schematic flow charts for all ovens and ranges that utilized a preheat board, Self.
Lab Safety. General Safety Rules 1. Listen to or read instructions carefully before attempting to do anything. Never attempt activities that aren’t authorized.
Oxyacetylene Cutting O.A.C. Pattern Cutter Cutting Torch.
Tensile testing of an as-cast copper alloy
Hand and Power Tools for construction. Basic tool safety  Keep in good condition  Right tool for job  Inspect tools  Operate tools correctly  PPE.
Types of Microscopes 0.1 mm is the smallest object that is seen with the human eye. When we view with a microscope, we are either viewing in micrometer.
Agenda Property Throwdown Closed System Energy Balance Theory
Microscope Basics.
Test Bed Cases Attempting to Duplicate Test Results December 12, 2014.
NMR loading procedure. load button needs to be held to continually supply air to the sample chamber If the air is not on the sample will drop.
Safety in Lab Environment. Safety Rules 1. Follow Instructions…Understand what you are going to do carefully before attempting to do anything. 2. Wear.
Current Balance MS&T Physics 2135, Lab E4.
375, 375XL 1¼” -2”. Modification Overview  Production of the 1¼” -2” 375 began in 2004 and is current.  The lead free version 375XL was introduced in.
Utility Vehicle Driving Safety. Types of Utility Vehicles Golf Carts Gator Vehicles Toro Vehicles Daihatsu.
Surface Planer Depth Scale Table Chip Guard / Shield Elevating HandWheel On / Off Switch.
AfterSalesTraining Welcome to AfterSalesTraining.
 Total energy in molecules of a substance including  a) kinetic E of moving molecules  b) potential E stored in chemical bonds.
We apply 120 VAC to the HM Unit (Remember to check polarity!) Our primary step down T/X provides power to terminal “X” and “COM” on the ignition control.
Teknologi Dan Rekayasa
Quick Installation – 1/4 Pressure Sensor
delivered with the compressor
CHIGO VRF System Commissioning.
Neutral current is zero
Purpose   What does ice do to hot boiling salt water and why does it do it?  
Physical chemistry experiment
Chapter 7 Deforming Solids.
Start program Start Start Time Duration Counter.
Frese DPRV Introduction Introduction 2017.
Thermal Expansivity by Dilatometry and Pycnometry
Types of Microscopes 0.1 mm is the smallest object that is seen with the human eye. When we view with a microscope, we are either viewing in micrometer.
Cutting an In-Line Dead-end Single Phase
Studio Day In you sketchbooks answer the following questions on the next available page. Are you finished with your sheet metal pendant? What were some.
NMR loading procedure Note location of the Sample Chamber, Air line (sample retriever/load button). and Depth gage.
Evaporation vs. Boiling
Cutting an In-Line Dead-end Single Phase
Replacing TrueAir Thermostat with Ecobee SI
Presentation transcript:

Shape Memory Alloy Thermomechanical Testing ME356 Spring April 2016

Objective

Test setup 1.When you arrive at the Instron room (MEB 127), the Instron should be set up with the proper grips and heating and cooling elements set up. Otherwise wait for the TA to set it up for you. Before starting make sure the cooling air valve is closed. Have the TA turn on compressed air. Environmental chamber (cooling system) Cooling line Insulating housing Instron Variac Temp controller Insulating chamber Air supply line Valve Regulator (behind here) Cooling line

2.Expose the grips by sliding the chamber towards the back of the Instron. Jog the grips so that the center-to-center distance of the screws is 100mm. This is your gauge length of the SMA specimen. 3.Secure the SMA wire in the grips by screwing them in place (don’t lose the screws please!!). Make sure the wire is held taut so there is no slack. 4.Jog the grips down a bit so there is slack in the wire (it will contract during heating). 5.Reposition and close the chamber. Make sure nothing is touching the grips, this could snag and affect your load data!

Test procedure Once the TA approves the setup, you can start testing. 1.Turn on temperature controller and heater (variac). Set the controller to 140 °C. Increase the heater voltage to ~50V to begin heating. (Never exceed 55V!) 2.While the chamber is heating, change the load profile in the Instron software (Bluehill 3) to 50 MPa. The TA can help you do this. 3.Once the temperature reaches 140 °C, balance the load cell. Then remove the slack from the wire until the load is ~1N. Reset extension. Variac (heater control) Temperature controller

4.Start the program. This will ramp up the load until 50 MPa is reached, then hold it there until the program is terminated by the user. 5.We will now record extension vs. temperature data as the specimen cools. Turn off the heater, and record the temperature and extension data (by hand!). You should record data every 2 degrees or so, but more often as the extension is changing rapidly! It may help to have more than one person recording data. In general, the slower the temperature change, the better the data will be. 6.As the temperature approaches room temperature, the cooling rate will slow down. Turn on the cooling air slowly to avoid an abrupt change. Modulate the airflow to maintain a constant rate. Continue cooling and recording data until -10 °C. 7.When the temperature reaches -10 °C, begin increasing the temperature by closing the cooling valve. As the temperature rise increases, you may turn on and slowly ramp up the heater voltage, until you return to 140 °C. At this point, the test is done. You should have ~ data points. 8.Terminate the Instron program. Remove the specimen and repeat for 100 and 150 MPa.

Post-test Turn off the heater, temperature controller, and air pressure. Remove wire from grips and generally clean up. Before you leave (!) plot your data, and determine the transition temperatures. Do this before you leave, because if you don’t realize your data is bad, you may be out of luck 