MixRite Water Driven Injectors Training

Slides:



Advertisements
Similar presentations
MixRite Water Driven Injectors Training
Advertisements

Purpose of a VPA Filling & Metering Pump… Imagine having an employee who constantly measures out a precise dose of liquid whenever it’s needed.
Flow Control Valves Series FC
Metering Pump Spare Parts Replacement. Pump Components (Metering Pump) Pumps are supplied with a 120VAC or 240VAC power cord. Use care to ensure pump.
Finally, a compressed air piping system so simple…it’s EZ!
Water King Inc. Delivering Experience, Quality, and Service Since PRODUCT OVERVIEW.
Chemigation. Chemigation Chemigation is the process of applying pesticides and fertilizer through irrigation waterChemigation is the process of applying.
5/4/ Vacuum Regulator Gas Feed Systems: Theory and Maintenance Thom DiGeronimo OperatorSchool.Com.
Booster System Basics: Constant Speed Systems
CNG Refuelling station. A company located in Cherasco (Italy), is among the world leaders in the field of designing and manufacturing of components and.
Proportioning Systems. 69 Proportioning Systems Now you know the benefits and uses of water additives, especially Class A foam. So how do we get the concentrate.
Hydraulics.
Proper Pump Installation Practices
Normal Operating Parameters Maintenance Schedule Common Problems Normal Operating Parameters Maintenance Schedule Common Problems ClearWater Tech, LLC.
Valves & Controls for Semiconductor Fabs Part 2 – Additional Products.
Injecting Chemicals into Drip Irrigation Systems Pierce’s Disease Research Symposium Flat Creek Estates May 22, 2007 Guy Fipps Professor and Extension.
© Swagelok Company, 2006 IFPAC Miniature Modular Stream Selection Valves Switching Valve CPAC NeSSI Workshop May 11, 2006.
© 2012 Rinnai America Corporation Rinnai Circ-Logic (RCL)
2001, 2002 & 3012 Series Operation 2001, 2002 & 3012 Series Operation (See Installation and Operation Manual for detailed instructions)
HYDRAULICS & PNEUMATICS
Experts in Chem-Feed and Water Treatment General Hydraulics Fluid Mechanics.
Air Compressors.
©2005 Armstrong International, Inc. Proper Piping Practices (Pumps)
Specifying Pumps. Prepared by Martin Ryan, 2013 Training Series: Using Aspen Technology Economic Evaluation Suite.
Installed Gain as a Control Valve Sizing Criteria Jon Monsen, Ph.D., P.E.
SEMINAR ON “GASOLINE DIRECT INJECTION”
MOST RELIABLE COMBINATION MASTER VALVE, WATER METER AND FLOW SENSOR
FUEL INJECTION SYSTEM OPERATION
Water Handling Operations
Batteries The purpose of the battery is to act as a reservoir for storing electricity.
Temperature Control Loop
Pumps and Lift Stations. Background Fluid Moving Equipment Fluids are moved through flow systems using pumps, fans, blowers, and compressors. Such devices.
AquaBlend Vs Dosatron D25
USA ZAMA BASIC BIS. USA ZAMA What is BIS ?  What does BIS mean? – BIS is an acronym for B alanced I dle S ystem – The BIS system is part of the idle.
Use of Residual Pressure Valves - Challenges and Opportunities for Indian subcontinent. Presented By: Rohit Behani.
Mazzei Injector Company, LLC
The complete flow monitoring solution Measure – Display – Switch – Transmit.
David Garvin Product Manager EarthDirEX Geothermal Copyright © 2015 Nortek Inc. All rights reserved.
Spray Heads & Nozzles. Product Overview - Spray Heads 1800 Series 1800 SAM-PRS UNI-Spray Best Durability & Reliability Best Performance Best Value.
WILO MVI Vertical Multi-Stage Pumps Multi-Stage Pumps for Commercial, Municipal and Industrial Applications Presentation Date – Revised Sept 2006.
ProMinent Fluid Controls, Inc.
PIPE LINE SYSTEM Series Pipe Line System Class I Class II Class III
FUEL TANKS, LINES, FILTERS, and PUMPS CBCAUTOMOTIVERKCBCAUTOMOTIVERK.
Launch Chameleon Plus P - More Preventive features and safety L - More Longer Lasting and robust U - More User friendly operation S - More Service friendly.
Variable Speed Applied to Pumps. Life Cycle Costs - Courtesy of Hydraulic Institute and Europump Initial cost is not the only cost associated with a pump.
Discover the Dosmatic Difference Trouble Shooting your Dosmatic injector for years of service.
Discover the Dosmatic Difference Maintaining your Dosmatic injector for years of service.
The complete flow monitoring solution Measure – Display – Switch – Transmit.
CENTRIFUGAL PUMPS:- DESIGN & PERFORMANCE Ir. N. Jayaseelan 2012.
Submitted by Pradeep pataskar Roll no.11031M02034.
ALIS Engineering A product of Advanced Lawn Irrigation Systems (ALIS) Joe Beach Tom Benich Luke Biggs Casey Valkenburg.
Water Softener Systems Engineered Water Treatment Solutions.
Welcome Growers Discover the Dosmatic Difference Installing your Dosmatic injector for years of service.
HYDRAULIC OVERSPEED CONTROL
FUEL SYSTEMS AND ITS COMPONENTS
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
HYDRAULICS & PNEUMATICS
Case sample of a CT option
Flexible Poly Pipe Tubing
AUTOMATIC ON-LINE BRUSHING FOR HEAT EXCHANGERS AND CONDENSERS
Pilot Operated Pulse Valve Manufactured by maniks
Fuel Supply System Service
Hydraulic Live Swivels
2018 SHADE Conference “Fundamentals (Keys) of Basic Irrigation Design”
Pumps and Lift Stations
CAFS On-Line Orientation
Hydraulic Live Swivels
Servo Pilot SFP-150 to 1500.
Pneumatic System Conditioning
Presentation transcript:

MixRite Water Driven Injectors Training

MixRite Installation Jordan Valley, Israel

MixRite Water Driven Injectors Operate without electricity using water pressure as the power source. Inject a proportional amount of fertilizer or additive into the water line regardless of pressure variations Maximum dilution variance is less than 10% Extremely low pressure loss compared to other systems 2.5 / 500 Series, maximum loss 15 PSI TF5, 10 and 25 – maximum loss 11.5 PSI 10 to 25% more flow than competitive models

MixRite 500 Series Standard models create a homogenized solution of chemical and water during normal operation Air vent Replaceable lip seals Mixed solution outlet Water inlet Viton Extreme seal and O-ring Chemical pick-up tubing

MixRite 500 Series Internal Bypass Used for the most aggressive chemicals that attack springs, screws, o-rings and other vulnerable materials Internal shaft seal Chemical injection point Water and chemical are not a homogenized solution at this point

Additional Benefits & Selling Features Manual or electric ON/OFF available on all systems Internal bypass on the engine system PulseRite cycle counter Units manufactured and designed with components for high chemical resistance PVDF models for sulfuric acid and other very aggressive chemicals Purple sleeve models for chlorine and mild acids Bypass units minimize chemical contact with pump components

Additional Benefits & Selling Features Durable body and cover made from Nylon12 reinforced with 30% Fiberglass Suction seal made from Viton Extreme rubber Engine lip seals made from Nylon12 + Teflon Hastelloy springs in suction check valve for special models Suction cylinder made from HDPE Built-in ribs in the suction cylinder avoids over-dosing damage Suction filter made from chemical resistant Polypropylene Bigger additive openings in the suction check valve

Lip Seal Kit All units ship with a free lip seal kit and chemical piston seal

All you need to do to select a MixRite is answer three questions What is the water flow and pressure through the system? What percentage of chemical do you want? Is the chemical corrosive?

MixRite Model Range Model Chemical Injection Rate Water Pressure Water Flow 2.5 / 500 Series & TF3 0.1 – 10% 3 – 120 PSI 0.08 – 14 GPM TF5 0.1 – 5% 15 – 120 PSI 0.9 – 22 GPM TF10 2.2 – 44 GPM TF25

Choosing the Rite MixRite WATER FLOW 1 10 20 40 50 110 500 Series .08 – 11 GPM TF 25 40 – 110 GPM 10 – 20 GPM TF 5 KEY TAKEAWAY All pumps have a mid-range where they operate most effectively 18 – 40 GPM TF 10 .08 – 14 GPM TF 3

MixRite 500 CW Series Delivers 2.5 cubic meters per hour or approx. 11 GPM Operates most efficiently at 1 to 10 GPM Has ¾” thread connections Chemical injection rates .1% to 1%, .3% to 2%, .4% to 4% and 3% to 10% Special models for harsh chemicals

MixRite 500 CL Series CL models identified by purple sleeve Designed to withstand chlorine and mild acids All upper seals made from Viton Extreme Check Valve seals made from Aflas All Hastelloy Springs

MixRite 500 PVDF Series PVDF PVDF models have white body Designed to eliminate potential chemical attack of body from sulfuric acid All upper seals made from Viton Extreme Check Valve seals made from Aflas All Hastelloy Springs and PVDF components

MixRite 3 14 Series Units Capacity up to 16 GPM, ¾” thread connections Increased Chemical Compatibility Aflas O-rings through unit Hastalloy and plastic engine springs for improved chemical compatibility Easy to read chemical adjustment sleeve Models: 14.CW.05 – 1-5% injection 1410A/M – 1-10% injection 1402A/M - .2-2% injection (available 2014)

MixRite TF3 New product introduced at Irrigation Association Show Dec, 2009 Developed from customer request for the greenhouse market Used extensively in landscaping Identical to 2.5 models except with 1” pipe threads Most greenhouses have 1” piping and want added water flow

MixRite TF 5 Delivers 5 cubic meters per hour or approx. 22 GPM Operates most efficiently at 10 to 20 GPM Has 1” thread connections Chemical injection rates .1% to 1%, .2% to 2%, and 1% to 5% TF 1% units available with updated seals for use with harsher chemicals

MixRite TF 10 Delivers 10 cubic meters per hour or approx. 45 GPM Operates most efficiently at 18 to 40 GPM Has 1.5” thread connections Chemical injection rates .1% to 1%, .2% to 2%, and 1% to 5% TF 1% units available with updated seals for use with harsher chemicals

MixRite TF 25 Delivers 25 cubic meters per hour or approx. 110 GPM Operates most efficiently at 40 to 110 GPM Has 2” thread connections Chemical injection rates .1% to 1%, .3% to 2.5%, and 1% to 5.5% TF 1% units available with updated seals for use with harsher chemicals

MixRite AgroRite Water treatment unit designed for aggressive additives For acid or chlorine or hydrogen peroxide Delivers 25 cubic meters per hour or approx. 110 GPM Operates with minimum flow of 23 GPM and maximum 110 GPM Has 2” thread connections Chemical injection rates .1% to 1%, .3% to 2%, .4% to 4%, and 3% to 10%

Injection % Across Varying Water Flow

Comparison To Other Injector Types Comments Installation Accuracy Operation Price Electric Req. Proportional Simple Good Moderate No MixRite Water is wasted Medium Poor Non-proportional Hydraulic Injectors High pressure loss Low Venturi Expensive Difficult Difficult to operate High Yes Venturi + Electronic Controller

Competitive Review Compared to Dosatron and Dosamatic, MixRite’s are Easier to maintain & operate Better chemical resistance Better U.V resistance Better value for the price Lower spare parts pricing

Installations What does an installation look like and what’s important to understand.

Drip Irrigation Installation

Typical In-line Installation How many of these items do you sell?

Parallel Installation

Bypass Loop

Bypass Loop

Bypass Loop

Bypass Calculation How to Calculate Volume per Click for % of Chemical GPM of Flow X % of MixRite X 100 = % of Chemical in Total Flow Total Flow through System 110 GPM X .05 X 100 = .0045% 1200 GPM ( Percent maximum Injection rate )

High Volume Feritgation

MixRite Water Driven Injectors Training