JMA Report 24 Mar 2009 Yoshihiko Tahara Incorrect RMA equation reported in the January meeting GSICS correction for MTSAT –Don’t we need standard GSICS.

Slides:



Advertisements
Similar presentations
22 March 2011: GSICS GRWG & GDWG Meeting Daejeon, Korea Tim Hewison SEVIRI-IASI Inter-calibration Uncertainty Evaluation.
Advertisements

GSICS Executive Panel 10 JMA GPRC Report
Combining Multiple References GSICS Web Meeting
Report from JMA 16th GSICS Executive Panel, Boulder, May 2015 Kotaro Bessho and Masaya Takahashi (Meteorological Satellite Center, Japan Meteoroogical.
Data Handling l Classification of Errors v Systematic v Random.
Regression Regression relationship = trend + scatter
GSICS Bias Monitoring Routine comparisons of satellite radiances against reference GSICS Correction Function to correct issued radiances For consistent.
Inter-calibration of Operational IR Sounders using CLARREO Bob Holz, Dave Tobin, Fred Nagle, Bob Knuteson, Fred Best, Hank Revercomb Space Science and.
Retrieval of cloud parameters from the new sensor generation satellite multispectral measurement F. ROMANO and V. CUOMO ITSC-XII Lorne, Victoria, Australia.
Report from JMA 17th GSICS Executive Panel, Biot, 2-3 June 2016 Masaya Takahashi on behalf of Kazumi Kamide Meteorological Satellite Center, Japan Meteorological.
GRWG Agenda Item Towards Operational GSICS Corrections for Meteosat/SEVIRI IR Channels Tim Hewison EUMETSAT 1.
Japan Meteorological Agency, June 2016 Coordination Group for Meteorological Satellites - CGMS Non-Meteorological Application for Himawari-8 Presented.
Characterizing Diurnal Calibration Variations using Double-Differences Fangfang Yu.
Bias analysis and correction for MetOp/AVHRR IR channel using AVHRR-IASI inter-comparison Tiejun Chang and Xiangqian Wu GSICS Joint Research and data Working.
22 March 2011: GSICS GRWG & GDWG Meeting Daejeon, Korea Tim Hewison NWP Bias Monitoring Double-Differencing as inter-calibration technique.
JMA GPRC report Arata OKUYAMA Meteorological Satellite Center,
Masaya Takahashi Meteorological Satellite Center,
Inter-calibration using DCCs and seasonality
GRWG/GDWG Joint Web Meeting Agenda
Paper under review for JGR-Atmospheres …
Jerome Lafeuille WMO Space Programme Office
Review of EUMETSAT’s GEO-LEO Correction
Report from KMA 17th GSICS Executive Panel, Biot, 2-3 June 2016
GDWG Agenda Item Existing netCDF Format Updates
Meteorological Satellite Center Japan Meteorological Agency
Vicarious calibration by liquid cloud target
GSICS SEVIRI-IASI Inter-Calibration Uncertainty Evaluation Tim Hewison1 The regression propagates these variances to estimate the uncertainty on the corrected.
Verifying the DCC methodology calibration transfer
Masaya Takahashi Meteorological Satellite Center,
GSICS GDWG/GRWG Joint meeting, Toulouse
JMA Agency Report Arata Okuyama, Masaya Takahashi, Hidehiko Murata, Ryoko Yoshino, Keita Hosaka, Tasuku Tabata Meteorological Satellite Center, Japan Meteorological.
GSICS Data Management and Availability to Users
FY2-IASI and FY3C-IASI towards Demo
Fangfang Yu and Fred Wu 22 March 2011
Japan Meteorological Agency / Meteorological Satellite Center
Tim Hewison (EUMETSAT) (GRWG Chair)
GOES Imager IR Midnight Calibration Anomaly and Correction
Characterizing DCC as invariant calibration target
JMA Agency Report 2017 Arata Okuyama, Masaya Takahashi and Hidehiko Murata Meteorological Satellite Center, Japan Meteorological Agency.
Combining Multiple References
Annual GSICS Calibration Report for {Agency}
Masaya Takahashi (JMA), Dohyeong Kim (KMA),
NOAA-KMA Collaboration on Imager Midnight IR Calibration Anomaly
AHI IR Tb bias variation diurnal & at low temperature
Diurnal and Seasonal variations of COMS IR inter-calibration
Himawari-8 Launch and its calibration approaches
GEO-GEO products – diurnal variations
Infrared Inter-Calibration Product Announcements
JMA Agency Report 2018 Masaya Takahashi, Yusuke Yogo and Hidehiko Murata Meteorological Satellite Center, Japan Meteorological Agency.
FY-2 IR GSICS Correction Policy
GSICS ATBD (ISRO) GSICS Algorithm Theoretical Basis Document (ATBD) for Inter-Calibration of Indian GEO satellites Pradeep Thapliyal Space Applications.
KMA Agency Report NMSC/KMA
The Aqua-MODIS calibration transfer using DCC
Meteorological Satellite Center, Japan Meteorological Agency
Na Xu, Xiuqing Hu, Lin Chen, Min Min
Use of GSICS to Improve Operational Radiometric Calibration
Developing GSICS products for IR channels of GEO imagers Tim Hewison
Masaya Takahashi1, Yusuke Yogo1, Qiang Guo2, Xiuqing Hu2, and Na Xu2
GSICS Products’ Improvements and Developments
Jörg Schulz (EUMETSAT) - Re-calibration of Meteosat archive using HIRS
Tim Hewison1 and all GSICS Developers EUMETSAT
GSICS Web Meeting Tim Hewison
Presentation of GSICS Inter-Calibration Results - Web Displays
Template for GSICS Bias Monitoring Web Pages
Variogram Stability Analysis
Defining the Products: ‘GSICS Correction’
Masaya Takahashi1, Yusuke Yogo1, Qiang Guo2, Xiuqing Hu2, and Na Xu2
Inter-calibration results of COMS/MI using with and without MBCC
Midnight calibration errors on MTSAT-2
Regression and Correlation of Data
Presentation transcript:

JMA Report 24 Mar 2009 Yoshihiko Tahara Incorrect RMA equation reported in the January meeting GSICS correction for MTSAT –Don’t we need standard GSICS correction? Brief report on AIRS and IASI accuracy evaluated by the spectral compensation technique (if time is available) JMA participants in JFY2009

Which Regression? Least squares (LS) –No error in X is assumed –Y = aX + b is not equivalent to X = a’Y + b’ Major Axis regression (MA) –Unit of X and Y should be the same –Y = aX + b is equivalent to X = a’Y + b’ Reduced Major Axis reg. (RMA) –X and Y are correlated –Y = aX + b is equivalent to X = a’Y + b’ –Easy to calculate from (written in only Japanese)

MTSAT IR Data Disseminated MTSAT Packet Data raw digital counts, blackbody and space observations, sensor temperatures MTSAT HRIT Data digital counts converted on a fixed Tb grid for each IR channel, with a Tb-count table linear to rad. (no calibration coefficient contained) Calibration Interpolation in radiance space Users can retrieve Tb easily from digital count looking at the Tb-count table What is GSICS correction for MTSAT convenient for users?

Current GSICS Correction for MTSAT IR I GEO = a I LEO + b is available on the JMA/MSC Web Why producing I GEO = a I LEO + b, now? –To compute Tb biases at 290, 250 and 220 K –Easy to compare with the results of GCC Inconvenience to users –Long way to get corrected TB data – I LEO = a’ I GEO + b’ is required for the correction –Sensor Planck functions for MTSAT are also required digital count Tb radiancecorrected radiance corrected Tb Tb-count table Planck functions for MTSAT IR I LEO = a’ I GEO + b’

Choices of GSICS Correction I GEO = a I LEO + b (no change) –Complicate to get corrected Tb count  Tb  rad.  corrected rad.  corrected Tb We got complaint from some researchers before. I LEO = a N GEO + b (corrected calibration equation) –Equation to get corrected radiance from digital count N GEO –Simpler digital count  corrected rad.  corrected TB Corrected TB-count table –The simplest digital count  corrected TB –Increase the volume Something else?

Define Standard GSICS Correction? To avoid confusion for users Standard expression? –I LEO = a N GEO + b (corrected calibration equation) All GPRCs may be applicable RMA regression keeps consistency with I GEO = a I LEO + b Standard LEO data usage? –Combine all LEOs (AIRS & IASI), Separate AIRS & IASI –Separate day & night, Separate LEO orbits Standard frequency to update the equation? –Every day, every week, every month, etc Standard period of data used to generate the equation? –One month, latest 30 days, latest 7 days, etc. Allow options for GPRCs –e.g.) Separate LEO orbits to correct MTSAT diurnal variation

larger AIRS noise AIRS erroneous channel (#276) Error trend in an AIRS detector module Normalized Standard Deviation Diff. (SD/Rad) between Observed and Estimated Radiances red: AIRS black: IASI larger IASI noise larger AIRS noise Blacklisted AIRS channels excluded

consistent red and black indicates biases associated with the spectral compensation method Mean TB Difference between Observation and Estimation red: AIRS black: IASI Blacklisted AIRS channels excluded large biases for AIRS #121 and #122 small biases for AIRS #133 and #134

JMA Participants in JFY2009 GSICS EP –Mr Toshiyuki Kurino (transition is planed) GRWG and GDWG –Ms Hiromi Owada for IR calibration (in GDWG & GRWG) –Mr Arata Okuyama for VIS calibration (in GRWG) –Mr Kenji Date (in GRWG) –Mr Ryuichiro Nakayama (in GDWG) Contact person for operation & product acceptance –Ms Hiromi Owada Leaving GSICS –Mr Yoshihiko Tahara –Mr Koji Kato Please update your address books!