X-STREAM Process Gas Analyzers

Slides:



Advertisements
Similar presentations
1 Series V4T 1/4 DIN Temperature Controllers. 2 3 Watlows Next Generation Styling Series 97 Matching 1/16 DIN Limit Controller Series F4S and F4D Ramping.
Advertisements

Variable Frequency Drives Bypass Options
IMR Environmental Equipment
… for Combustible Gas Detection S4000C Intelligent Sensors..
Customer Service – International dept. STAR 24 3 E.
“Enerpak” Units » Propeller Type Fan » Size 100 – 400 MBH » 80% Thermal Efficiency » Natural or LP Gas » 10 Year Warranty on Heat Exchanger, Burners,
Inputs: Digital and 4 configurable for Digital or 10 bit Analog Outputs:4 - 8 amp Relays or 700ma Transistors (1 PWM) 4 Line by 18 Character fully.
Veilux Fiber Optic Transceiver
MIFII DIGITAL FEEDER PROTECTION A Cost Effective Protection Solution for Overcurrent Protection at Any Voltage Level GE Multilin
 25,000 BTU per Cell  Cell Halves Edge Seams Folded and Crimped. Individual Cells Welded Together to Form Completed Heat Exchanger Assembly.  20 Gauge.
Company Confidential © 2005 All Rights Reserved. What is it? State-of-the-art: microprocessor-based, wall-mount gas monitor Easy installation and operation:
Copyright © 2011 Rockwell Automation, Inc. All rights reserved. Insert Photo Here OneGear™ 7.2kV Motor Control Center.
Zone 1 & 21 Universal Access Point Enclosure System I Copyright Extronics Ltd Zone1 & 21 Universal Access Point Enclosure System.
E VERY L IFE H AS A P URPOSE… Flame Detection Theory.
Introducing… HVS4000 & HVS400 Toxic Gas Detectors from Halogen Valve Systems.
E VERY L IFE H AS A P URPOSE… Z Gard ® Family of Gas Detection Products.
MET ONE 7000 Series Remote Airborne Particle Counters Customer Name Date Presenter Presenter Title.
3U ATCA Shelf October Proprietary and Confidential-
Engineer Presentation
GST FIRE ALARM SYSTEM INTERNATIONAL BUSINESS DEPARTMENT , GST BEIJING
You Can Measure the Benefits… Training Course Introduction to SmartScan.
© ABB Group July 3, 2015 | Slide 1 IRC5C second generation Overview Product Management, ABB Robotics, October 2014.
AS-i, The Simplest Automation Networking Solution Dated: 10/30/2008.
MUST HAVE SHOULD HAVE COULD HAVE Module # 010. Qi Hardware Objectives Recognize hardware Know how to interface to field equipment Know the 4 different.
NeSSI Update An Implementation of the Generation 2 Bus Siemens Activities November 2006.
Ultima® X Series Gas Monitors
ONYX Product Overview.
Single-Loop PID Controllers All Watlow single-loop auto-tuning temperature and time/temperature profiling controllers are available in 1/32, 1/16, 1/8.
E VERY L IFE H AS A P URPOSE… Chillgard ® L Series Refrigerant Monitors.
EESIFLO International Pte Ltd
1 © Red Lion Controls Inc. Introducing the RAM 9000.
System Elements HighPoint Broadband Delivery System Sector 1 Sector 3
ASAB New Additions Extended Bypass Models Ethernet Modules Remote Control Panel.
GasGard® XL Monitor.
BioWin ®. Bio Gas – The alternative energy source of the future! BioWin ® - Bio Gas Analysis of the future!
ENERGY of 21 st Century Independent Power Supplies.
High Sensitivity Smoke Detection
NAVIGATOR™ Portable Balances
XS26-2 Expandable Safety Controller.
Motor-driven pumps  Sigma/ 1  Sigma/ 2  Sigma/ 3.
-Proprietary and Confidential-
E VERY L IFE H AS A P URPOSE… 9010 / 9020 Controller.
EGA Technical World Leaders in Combustion Management Solutions Mk7 EGA.
Digital Temperature Switches The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and.
1 Name | Confidential Date Center line content EXPLOSION-PROOF ENCLOSURE MARKET INTRODUCTION PRESENTATION.
World Leaders in Combustion Management Solutions Module Gas Setup Introduction The Mk7 E.G.A Cell Status Further Information.
New Product Developments World Leaders in Combustion Management Solutions New Products New Products.
World Leaders in Combustion Management Solutions New Product Developments Autoflame Sales Meeting 2011 New Product Developments.
1 Powerware kVA The modular, scalable, redundant UPS for midrange applications.
ACT20X Ex isolator/ amplifier. Page 2 ACT20X (Ex isolators family) Overview - Connects to process equipment in Class/Div, or Zone 0 - Zone 2 areas - ACT20X.
AEON 4000 Including the SMPS 4000 rectifier and the AEON Gold Alarm & Monitoring Unit.
FLATPACK Rev.5 September 2002 Updated versions may be available.
GmbH Specialist hotel application ComplianceCommercial refrigeration Industrial refrigeration Light Industrial Gas Detection MGS-550 Product Portfolio.
LOGO Electronic Volume Converter TZ, PTZ ”Flougas-T”
Linescanner MP150 Infrared Temperature Measurement for Quality Control and Process Automation Raytek Confidential 10/2010, Rev. B.
Asahi/America Electric Actuators
C1300 advanced circular chart recorder
Asahi/America Electric Actuators Series 94.
FEEDER PROTECTION UNIT
Customer Presentation
Asahi/America Electric Actuators Series 94.
IRC5C second generation Overview
Series 5300 Lithium Cell Formation System
Day 2 Training - Technical
PQube® 3 Standard Pre-Wired Packages for quick and easy installation
Its strengths, your benefits
Total Solution for Flue Gas Analyzer Series
Presentation transcript:

X-STREAM Process Gas Analyzers Customer Presentation

X-STREAM Overview Packaging options Common design for all 3 variations Measurement options Operator interface and connectivity Installation Service and maintenance Features and benefits Applications

NEW NEW Packaging Options Three Variations Field housing Wall mount NEMA 4X / IP66 Stainless steel housing Type approved pressurization systems and non-incendive solution for hazardous areas NEW General purpose Rack mount Tabletop Flameproof housing Wall mount NEMA 4X / IP66 Cast aluminum housing Certified for ATEX and CSA-C/US hazardous areas NEW

Packaging Options - General Purpose Rack mount Standard 19” housing Small analyzer footprint Depth: 13.6 inches (344,5 mm) Minimizes space required for cabinet installations Separation of physics and electronics with purge Case purge enables measurement of corrosive and toxic gases protecting the electronics and providing operator safety

Packaging Options - General Purpose Rack mount Tabletop Tabletop accessory kit to modify rack version Mount 4 feet on the bottom plate Remove the mounting brackets (2x 4 Philips screws) Side view

Packaging Options - General Purpose X-STREAM replaces BINOS 100 Series, 755 and 880 BINOS 100 2M Depth: 19 inches (482 mm) 880 / 755 Depth: 19-24 inches (483-610 mm) BINOS 100 Depth: 16.5 inches (417 mm) BINOS 100 2M Depth: 19 inches (482 mm) 880 / 755 Depth: 19-24 inches (483-610 mm) BINOS 100 Depth: 16.5 inches (417 mm) Depth: 13.6 inches (344,5 mm)

Packaging Options - Field Housing Wall mount Small analyzer footprint Width: 19.1 inches (484 mm) Height: 18.1 inches (460 mm) Depth: 8.7 inches (222 mm) Minimizes overall space required for installation Minimal leakage Hinges and square sash fasteners outside of sealed compartment Safety glass directly glued to front cover Extended ambient temperature range -20 to +50 °C (-4 to +122 °F) Tropicalization for high ambient humidity NEW

Packaging Options - Field Housing Separation of physics and electronics with purge Case purge enables measurement of corrosive and toxic gases protecting the electronics and providing operator safety ATEX-approved Zone 2 non-incendive solution for non-flammable gases (type approval for CSA-C/US Div. 2 pending) Pressurization/purge systems for hazardous areas NEW

Packaging Options - Field Housing ATEX pressurization/purge systems for hazardous areas ATEX-certified pressurization system for Zone 1 Similar system for Zone 2 with simplified pressurization Versions for flammable & non-flammable gases NEW

Packaging Options - Field Housing CSA-C/US pressurization/purge systems for hazardous areas Upgrade with a CSA-C/US approved Z purge Type approval for CSA-C/US Div. 2 pending Versions for flammable & non-flammable gases NEW

Packaging Options - Flameproof Housing Wall mount Smaller analyzer footprint Width: 22.9 inches (580 mm) Height: 20.1 inches (510 mm) Depth: 11.5 inches (290 mm) Minimizes overall space required for installation NEW

Packaging Options - Flameproof Housing Extended ambient temperature range -20 to +50 °C (-4 to +122 °F) Tropicalization for high ambient humidity Separation of physics and electronics with purge Case purge enables measurement of corrosive and toxic gases protecting the electronics and providing operator safety Flameproof enclosure for hazardous areas Class I, Zone 1, Group IIB + H2, T4 Type approval for ATEX Zone 1 Type approval for CSA-C/US Zone 1 NEW NEW

Common Design for All 3 Variations Reduced number of internal parts Reduces customer inventory Reduces required spare parts

Common Design Compact card cage for wide range power supply and motherboard Card cage allows extension cards (e.g. TCD board) Easy removal of motherboard using detent springs

Measurement Options Non-dispersive Photometry NDIR/UV/VIS Improved NDIR capability on X-STREAM platform New components, e.g. nitrogen monoxide Lower ranges, e.g. 0-100 ppm CO and 0-250 ppm NH3 New benches with pyro-electric (solid-state) detectors are less sensitive to ambient temperature changes NDUV channels included Sulfur dioxide Nitrogen dioxide Dynamic ranges available – analog output can be adjusted in the field between minimum and maximum concentration Paramagnetic Oxygen Solvent resistant cells Corrosion resistant cells Intrinsically safe cells

Measurement Options Electrochemical Oxygen Thermal Conductivity Long-term stability Thermal Conductivity Standard aluminum cells 3 components only in contact with sample gas Aluminum, glass and Viton Long-term stability of gas-filled reference side Corrosion and solvent resistant SS cells Completely welded Quartz coated Intrinsically safe cells

Measurement Options Single or dual channel capability In series or parallel Flexible combinations of measurement principles All combinations of NDIR/UV/VIS, O2 and TCD available Sample handling options offered: Autocalibration with internal valve block or external valves via digital outputs Gas sampling pump for basic applications Barometric pressure compensation Flow sensor via internal pressure switch

Measurement Options Thermostatic control of physics compartment Enables low sample gas concentrations Enables measuring sample gas with higher dew point Thermostatic control Cover removed Rack mount / tabletop

Operator Interface and Connectivity Preferred language selectable during run-time English, French, German, Italian and Spanish 4 x 20 Characters alphanumeric display Easy to understand text in the chosen language Measurement information Analyzer status messages GP rack mount and tabletop with LCD only Two different displays available for field housing LCD for 0 to +50 °C (+32 to +122 °F) VFD for -20 to +50 °C (-4 to +122 °F)

Operator Interface and Connectivity 6 Keys to operate the menu UP/ DOWN LEFT / RIGHT keys HOME key for return to measurement / abort editing ENTER key to select menu / function

Operator Interface and Connectivity Status LED’s and keys labeled by use of icons Failure (red) Status message Maintenance request / function check / out of specification (red flashing) Power (green)

Operator Interface and Connectivity Communication capabilities RS 485/232 with Modbus RTU protocol Standard industrial protocol for easier connectivity Ethernet with Modbus TCP protocol NEW

Installation Light field housing enables easy installation Up to 26 kg (57 lbs.) Light flameproof version enables easy installation Approximately 57-63 kg (126-139 lbs.) Line Voltage: 96 – 264 VAC, 50/60 Hz for worldwide installation

Installation Standard I/O: 2 optically isolated analog outputs – 4(0) to 20 mA 3 status relays Analyzer failure Maintenance request / out of specification Function check (e.g. “in calibration”) Ethernet interface or serial interface (RS 485/232) Bi-directional interface

Installation Optional I/O: 8 digital outputs 7 digital inputs Concentration alarms (Pre-alarm and main alarm) Control of external calibration valves or calibration status 7 digital inputs Remote calibration control Remote valve control Remote pump control

Installation – General Purpose Rack mount and tabletop rear panels Analog out, relays, serial Digital in and out Power Terminals for power and signal cables Gas inlets and outlets Analog out, serial, relays Power Digital in and out Sockets for power and signal cables

Installation – Field Housing Wall mount Cable glands for power and signal cables Purge gas inlet 4 supports for wall mounting Gas inlets and outlets including purge gas outlet

Installation - Field Housing Power lines on screw terminals Signal lines on terminal strips Power EMI Filter Power terminals with fuses 4 cable glands for power and signals Terminals for signals

Installation – Flameproof Housing NEW Electrical connections for power and signal cables NPT adapters for conduits (CSA) Cable glands (ATEX) Gas inlets and outlets, including purge gas inlet and outlet, with flame arrestors 4 supports for wall mounting

Installation - Flameproof Housing Power lines on screw terminals Signal lines on terminal strips NEW Power EMI Filter Power terminals with fuses 4 cable connections Terminals for signals

Service and Maintenance All assemblies easily accessible from top or front of analyzer Physics assembly Card cage and electronic boards Easy service of field housing and flameproof versions in the field Front panels are attached and swing down for service purposes User interface is visible and usable while servicing the analyzer

Service and Maintenance Easy service in the field Front door flipped down User interface is visible and operable 2 nuts to loosen on both sides

Service and Maintenance Easy exchange of benches or parts in the field Replacement without need for return to factory Replacement of pyro-electric bench parts without exchange of complete cell/filter cell or chopper/filter assembly (filter on pyro-electric detector) Software update by exchanging Flash PROM in the field allows to preserve Factory settings Customer settings

Features and Benefits Features Benefits Small footprint and light enclosures Requires small cabinets/analyzer shelter/wall mounting space and provides easy installation Support for multiple languages Enables operators to use analyzer in native language Field Housing and Flameproof version have NEMA 4X / IP66 housing Enables outdoor use and installation in harsh environments Field Housing and Flameproof version have tropicalization available and an extended ambient temperature range: -20 to +50 oC (-4 to +122 oF) Eliminates the need for shelters in many climates Measure up to 2 components in any measuring combination Provides flexibility in using analyzers in different applications

Features and Benefits Features Benefits Improved NDIR capability and added UV capability on X-STREAM platform Increased number of applications where analyzers can be used Optional thermostatic control Enables measuring lower sample gas concentrations and at higher dew points Separation of electronics and physical benches with purge capability Enables measuring corrosive and toxic gases while protecting electronics and providing operator safety Modbus communication capability over an Ethernet or serial interface Standard industrial protocol for easier connectivity

Features and Benefits Features Benefits Line voltage and terminal strips for I/O connectivity Ease of installation Sample handling options Minimizes need for external sample handling system All assemblies easily accessible from front of analyzer Easy maintenance and service Benches exchanged and software updated in field without returning analyzer to factory Global certifications Enables use in non-hazardous and hazardous areas world-wide

Applications Refining, petrochemical and chemical process gas Hydrogen, ammonia and fertilizer production Metallurgical process gas, hardening and heat treatment Natural gas production and distribution Safety measurement for flammable mixtures Hydrogen cooling of gas turbines Fermentation gases in biotechnology Biogas for landfill applications Scrubber and activated carbon filter efficiency control Flue gas analysis of boilers, power plants, process furnaces and incinerators