Safety Testing of Medical Electrical Equipment
Advertisements

Bonding and Grounding What? Why? How?
Earthing PRESENTATION BY: Er. Satnam Singh Lecturer(Electrical engg.)
Electrical Safety Basic Electrical Safety Rafael Coll, Environment Safety and Health Section Health& Safety Group Ext Pager: (630)
GROUND FIELD RESISTANCE TESTING
“Equipment bonding jumpers: are they always necessary?” Massimo Mitolo, Senior Member, IEEE.
Proposed Design and the Operation of a Disconnecting Device for Small EG Installations Prepared by Hendri Geldenhuys.
Electrical Safety. Introduction Electricity is essential to modern life Some employees work with electricity directly Some indirectly Electricity is a.
1 EXPERIENCE AND RELIABILITY. 2 Short circuit loop measurements EN EN
The Home Inspection Book: A Guide for Professionals By Marcia Darvin Spada Copyright, Thomson/South-Western, 2003, Revised, 2006.
NFPA ELECTRIC VEHICLE SAFETY FOR EMERGENCY RESPONDERS Module II : Basic Electrical Concepts And Hazards Module II : Basic Electrical Concepts And Hazards.
Resistance in Electrical Systems
Physiological Effects of Electricity on Human Body by Mohd Yusof Baharuddin.
Protection against Electric Shock (Note: All the mentioned tables in this course refer to, unless otherwise specified, Low Voltage Electrical Installation.
Electricity at Work.
4.3 Notes Resistance in Electrical Systems. Properties of Materials Conductors Have a large ability to conduct electric current They contain many free.
EVPC-2-5 Safety Requirement in Attachment 111 JASIC.
POWER SYSTEM PROTECTION
Ferris State University & Michigan Department of Career Development 1 Electrical Safety.
Electrical Resistance and Ohm’s Law Electric circuits are used to convert electrical energy into some other form of energy we need.
Voltage, Current, Resistance, Ohm’s Law 10.9,
Mrs. Brinston. a. Electrical malfunction is the second leading cause of fires in hospitals. b. Fortunately, electricity is also the most manageable of.
CHAPTER 6 EARTHING SYSTEM.
Basic Electrical Safety
BEAMLINE for SCHOOLS – East Area ELECTRICAL HAZARDS SAFETY 11 th September 2015 HSE Unit 1.
Ground loops Why grounding is so important ?DefinitionGround loops :(Introduction)where ground loops affect ?Ground loops are created by :Solutions.
© 2005 PRS S.A. Ships’ electrical power network systems protected from damages caused by short-circuit current other than three-phase symmetrical current.
Lesson 6 Voltage Do we need to MEASURE it? OR Do we need to DETECT it?
Electrical Safety Safety Unit Lesson 6. Electricity Electric shock from welding and cutting equipment can kill or cause severe burns by coming in contact.
GROUND FIELD RESISTANCE TESTING COMPLYING WITH MSHA REGULATIONS.
PR570 POWERITE II TRAINING Dedicated to Success in Electronic Servicing for 50 Years.
 Electrical circuit: a closed loop where charged particles flow  Electrical current: a flow of charged particles (e - )  Direct current (DC): a flow.
In the Name of Allah, the Most Beneficent, the Most Merciful University and science of Faculty of Scienc& Technology Engineering Department of Electronic.
Electrical Safety Authority
132KV GSS PIPAR CITY JODHPUR
Current Electricity is the rate at which charges pass a given point. The higher the current is the greater the number of charges pass the point each second.
Testing of Low Voltage Installations
Timing (minutes) Learning ObjectiveMain tasks / ProcessResources / tools 5TitleStandard Operating Procedures for Power Press Machine Slide 1 5Index 
Chapter 3 PHYSICAL INJURY AND CONTROLS 3.2 Electrical Safety
Lecture Name: Dr. Mohammed Elmaleeh Office Location: Building No. D Office Contact Number: ELECTRICAL CIRCUITS (EE 270)
OICA TF8 drafting annex Mar. **, 2016 TF8 OICA pilot 1 EVSTF-08-25e.
Electrical Safety Basic Electrical Safety. Electrical Safety  Course not designed to teach you to work on electrical equipment. Basic Electrical Safety.
Principles of Electricity Volt The measurement of electrical pressure.
UNIT-5. ELECTRICAL SAFETY, WIRING & INTRODUCTION TO POWER SYSTEM
Ground Bond and Ground Continuity Testing
4.0 DOMESTIC ELECTRICITY Domestic electricity is that electricity which is supplied to homes under specific conditions of current and voltage. Voltage,
Hipot Testing 101.
PROTECTION AGAINST INDIRECT CONTACT
Meet Our Team Anthony Arroyo Syed Abidi Allison Oba Presenter Panelist
Grounding.
Basic Electricity.
Basic Electrical Safety
Electricity - Current.
Notes 5 ECE 3318 Applied Electricity and Magnetism Fall 2017
Webinar Notes Please use the Q & A utility to ask us any questions concerning the material being presented. Please contact Brittany Socha - chat line.
Maintenance schedule for different equipment and their records in a hospital By Mr. Rahul kumar.
Low Voltage Hazards Low voltage = Higher than 50V ac, 120Vdc
ELECTRICAL POWER-II Electrical engineering sixth semester
Electrical energy By; Kemi and Kim.
ECMA-287 Safety of Electronic Equipment Safeguards to reduce harmful exposure to energy sources Ecma TC12 Rue du Rhône CH-1204 Geneva - T: +41.
Basic Electrical Safety
Basic Electrical Safety
Basic Electric Principles
Electrical components and systems
Parker domnick hunter. Safety of Electrical and
Biosco: MV/LV prefabricated substations IEC Presentation of the standard Safety is a choice.
Presentation transcript:

the Most Beneficent, the Most Merciful In the Name of Allah, the Most Beneficent, the Most Merciful University and science of Faculty of Scienc& Technology Engineering Department of Electronic Engineering Major: Biomedical Engineering Report about: Association for the Advancement of Medical Instrumentation AAMI By: 1-Salman Abass Alzoriki 2- Aref Abdo Mohammed Alkobi Under the supervision of: Dr. Eng. Fadel Alakwa. 2010-2011

2-Human Factors Design Principles : 1-Scope. 2-Normative references. 3-Terminology and definitions. 4-General requirements. 5-General requirements for testing ME EQUIPMENT. 6-Classification of ME EQUIPMENT and ME SYSTEMS. 7-Protection against electrical HAZARDS from ME EQUIPMENT.

2-Normative references: 1-Scope: This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of MEDICAL ELECTRICAL EQUIPMENT and MEDICAL ELECTRICAL SYSTEMS, hereafter referred to as ME EQUIPMENT and ME SYSTEMS. 2-Normative references:

3-Terminology and definitions MEDICAL ELECTRICAL EQUIPMENT(ME EQUIPMENT): Electrical equipment having an APPLIED PART or transferring energy to or from the PATIENT or detecting such energy transfer to or from the PATIENT. ENCLOSURE: Exterior surface of electrical equipment or parts thereof. HAZARD: Potential source of HARM. LEAKAGE CURRENT: Current that is not functional. PATIENT: Living being (person or animal) undergoing a medical, surgical, or dental PROCEDURE. TYPE TEST: Test on a representative sample of the equipment with the objective of determining if the equipment, as designed and manufactured, can meet the requirements of this standard.

CLASS I: Term referring to electrical equipment in which protection against electric shock does not rely on BASIC INSULATION only, but which includes an additional safety precaution in that means are provided for ACCESSIBLE PARTS of metal or internal parts of metal to be PROTECTIVELY EARTHED. Example of a CLASS I ME EQUIPMENT.

Example of a metal-enclosed CLASS II ME EQUIPMENT. CLASS II: Term referring to electrical equipment in which protection against electric shock does not rely on BASIC INSULATION only, but in which additional safety precautions such as DOUBLE INSULATION or REINFORCED INSULATION are provided, there being no provision for protective earthing or reliance upon installation conditions. Example of a metal-enclosed CLASS II ME EQUIPMENT.

TYPE B APPLIED PART: APPLIED PART complying with the specified requirements of this standard to provide protection against electric shock, particularly regarding allowable PATIENT LEAKAGE CURRENT and PATIENT AUXILIARY CURRENT. MD

TYPE BF APPLIED PART: APPLIED PART complying with the specified requirements of this standard to provide a higher degree of protection against electric shock than that provided.

TYPE CF APPLIED PART: F-TYPE APPLIED PART complying with the specified requirements of this standard to provide a higher degree of protection against electric shock than that provided by TYPE BF APPLIED PARTS.

F-TYPE ISOLATED: APPLIED PART in which the PATIENT CONNECTIONS are isolated from other parts of the ME EQUIPMENT to such a degree that no current higher than the allowable PATIENT LEAKAGE CURRENT flows if an unintended voltage originating from an external source is connected to the PATIENT, and thereby applied between the PATIENT CONNECTION and earth. F-TYPE ISOLATED: APPLIED PART in which the PATIENT CONNECTIONS are isolated from other parts of the ME EQUIPMENT to such a degree that no current higher than the allowable PATIENT LEAKAGE CURRENT flows if an unintended voltage originating from an external source is connected to the PATIENT, and thereby applied between the PATIENT CONNECTION and earth.

4-General requirements: 4.1-Conditions for application to ME EQUIPMENT or ME SYSTEMS. 4.2-RISK MANAGEMENT PROCESS for ME EQUIPMENT or ME SYSTEMS. 4.3-ESSENTIAL PERFORMANCE. 4.4-EXPECTED SERVICE LIFE. 4.5-Equivalent safety for ME EQUIPMENT or ME SYSTEMS. 4.6-ME EQUIPMENT or ME SYSTEM parts that contact the PATIENT. 4.7-SINGLE FAULT CONDITION for ME EQUIPMENT. 4.8-Power supply. 4.9-Power input.

4.10-Components of ME EQUIPMENT.

5-General requirements for testing ME EQUIPMENT: 5.1-TYPE TESTS. 5.2-Ambient temperature, humidity, atmospheric pressure. 5.3-Supply voltages, type of current, nature of supply, frequency. 5.4-Repairs and modifications. 5.5-Sequence of tests. 5.6-Determination of APPLIED PARTS and ACCESSIBLE PARTS. 6-Classification of ME EQUIPMENT and ME SYSTEMS: 6.1-Protection against electric shock. 6.2-Protection against harmful ingress of water or particulate matter. 6.3-Method(s) of sterilization. 6.4-Mode of Operation: ME EQUIPMENT shall be classified for either CONTINUOUS OPERATION or non-CONTINUOUS OPERATION

Muscular contractions 30+ mA Respiratory paralysis 50+ mA 7-Protection against electrical HAZARDS from ME EQUIPMENT: 7.1-Fundamental rule of protection against electric shock. 7.2-Classification of APPLIED PARTS. 7.3-Limitation of voltage, current, or energy. 7.4-Measuring Circuits of electrical HAZARDS. Current Effect 3+ mA Shock 10+ mA Muscular contractions 30+ mA Respiratory paralysis 50+ mA Heart paralysis (can be fatal) 100+ mA Ventricular fibrillation (usually fatal) 200+ mA Heart clamps tight 1500+ mA Tissue and organs burn

7.4.1-EARTH LEAKAGE CURRENT: Current flowing from the MAINS PART through or across the insulation into the PROTECTIVE EARTH CONDUCTOR.

Compare between EARTH LEAKAGE CURRENT standards: Leakage current(μA) Standards I/CF I/BF I/B 500 IEC 601-1 AAMI HEI 95 AS/NZS 3551

7.4.2-Protective Earth Resistance:

Protective Earth Resistance (Ω) Compare between Protective Earth Resistance standards: Protective Earth Resistance (Ω) Standards I/CF I/BF I/B 0.2 IEC 601-1 VDE 751-1 HEI-95 AAMI AS/NZS 3551 Allowable protective earth impedance where the fault current is limited: Z = Impedance of PROTECTIVE EARTH CONNECTION in ohms MD = Measuring device IF = Maximum continuous prospective fault current in amperes. PE

7.4.3-Patient Leakage Current:

7.4.4-VDE, Equivalent Patient Leakage: (Verband der Elektrotechnik, Elektronik und Informationstechnik) (Association for Electrical, Electronic and Information Technology) I/CF I/BF (μA)50 5000(μA)

7.4.5-Patient Auxiliary Current:

7.4.6-Enclosure Leakage Current:

7.4.7-Mains Insulation Resistance:

7.4.8-Applied Part Insulation Resistance:

7.4.9-Mains on Applied Part:

7.4.10-VDE, Equivalent Device Leakage:

7.4.11-Accessible Leakage Current:

7.4.12-Accessible Voltage:

7.5-Insulation : Insulation example 2: Insulation example 1:

Insulation example 4: Insulation example 3:

Insulation example 5: Insulation example 6:

Allowable values of PATIENT LEAKAGE CURRENTS and PATIENT AUXILIARY CURRENTS under NORMAL CONDITION and SINGLE FAULT CONDITION: Current in μA Click here Click here Click here Click here Click here :Key NC = NORMAL CONDITION. SFC = SINGLE FAULT CONDITON.