GS-1150 HANDHELD SPECTROPHOTOMETER. ABOUT GAMMA SCIENTIFIC With over 50 years of experience in developing commercial light measurement instruments, Gamma.

Slides:



Advertisements
Similar presentations
Greenstar Nomad two-way portable telephone and Web access - anywhere in the world completely solar-powered, portable, rugged specially-configured laptop.
Advertisements

Dr. Richard Young Optronic Laboratories, Inc.
Next generation high performance instrument for measuring Luminance and Chromaticity of light sources.
THS3000 Product Introduction Market Dynamics  Customers require more flexible solutions  Many test solutions are driven by both measurement needs.
R-Scan Lite. Portable Dry-Coupled B-Scan Imaging System.
AXIS New Innovations October AXIS Product Naming Structure.
VISION MACHINE AUTOMATED SIEVE CERTIFICATION SYSTEM.
Mobile light measurement system Measuring light has never been easier.
A Guide to Spectroradiometry
Microspectrophotometry Validation. Reasons for Changing Instruments Reduced reliability. Limited efficiency. Limited availability and cost of replacement.
OPHIR-SPIRICON INC. 1 January 2009 OPHIR-SPIRICON INC. The True Measure of Laser Performance™ What’s New for 2009.
Rotary Encoder. Wikipedia- Definition  A rotary encoder, also called a shaft encoder, is an electro- mechanical device that converts the angular position.
7. Beer’s Law and It’s Implications for Instrument Construction.
CPSC 641 Computer Graphics: Radiometry and Illumination Jinxiang Chai Many slides from Pat Haranhan.
Radiometry and the Radiometer
PASCO scientific: Solid State Spectroscopy with SPARK Tom Loschiavo Chemistry Education manager.
ABRF meeting 09 Light Microscopy Research Group. Why are there no standards? Imaging was largely an ultrastructure tool Digital imaging only common in.
K-Space Associates, Inc. kSA BandiT: Band-edge Thermometry.
OL 750 Measurement Systems
Spectrophotometer Jan 28, 2002 Deryck Hong Suryadi Gunawan.
MDR ECE 415 Team Advisor: Professor Marinos Vouvakis Douglas Imbier EE Team Leader wireless, sensors Edmons Zongo EE Treasurer display, sensors Nicholas.
OL Series 754 Portable UV-VIS-NIR Spectroradiometer The OL 754 Portable UV-Visible-NIR Spectroradiometers are a series of compact, portable, double monochromator.
Digital Cameras (Basics) CCD (charge coupled device): image sensor Resolution: amount of detail the camera can capture Capturing Color: filters go on.
Activity: Emission spectroscopy and smart sensors.
Designing for the Alternative Energy market CONFIDENTIAL: All contents copyright of Illinois Tool Works, Inc. (ITW). The ITW Photonics Group, Cal Sensors,
Basic Principles of Imaging and Photometry Lecture #2 Thanks to Shree Nayar, Ravi Ramamoorthi, Pat Hanrahan.
© DIAMOND SA / / 1 CLEANING A focal point in fiber optics.
 A monitor or display is an electronic visual display for computers.  The monitor consists of : o the display device o circuitry o enclosure The display.
Pentagon Digital Mini Pocket Projector Product Info.
TRB 2000Photometry for Traffic Engineers1 Photometry for Traffic Engineers... Workshop presented at the annual meeting of the Transportation Research Board.
Page 1 © 2008 IDEAL INDUSTRIES IDEAL Micro OTDR Oktober 2008 Konstantin Hüdepohl.
[1] Reference: QCam API reference manual document version Charge Coupled Device (CCD)
Topic 2 - Overview of Image Acquisition and Processing Systems DIGITAL IMAGE PROCESSING Course 3624 Department of Physics and Astronomy Professor Bob Warwick.
Make the most of your energy Make the most of your energy SM Add application photo in this area Need an easy to use, modular system for revenue metering?
STATUS REPORT OF FPC SPICA Task Force Meeting March 29, 2010 MATSUMOTO, Toshio (SNU)
EE 7700 High Dynamic Range Imaging. Bahadir K. Gunturk2 References Slides and papers by Debevec, Ward, Pattaniak, Nayar, Durand, et al…
Chapter 3 Measuring / Testing Optoelectric Devices.
Optronic Laboratories Inc. OL Series 750 Automated Spectroradiometric Measurement System Optronic Laboratories Inc. OL Series 750 Automated Spectroradiometric.
Correlation between visual impression and instrumental colour determination for LEDs János Schanda Professor Emeritus of the University of Pannonia, Hungary.
OL Series 750 Automated Spectroradiometric Measurement System The OL Series 750 is an extremely versatile spectroradiometric measurement system capable.
DECam Daily Flatfield Calibration DECam calibration workshop, TAMU April 20 th, 2009 Jean-Philippe Rheault, Texas A&M University.
LIVES: LED LIV and Emission Spectrum Testing Solution W2 Laboratories
Compact High-Speed Spectroscopic Ellipsometer
OL 750 Measurement Systems OL 750 Measurement Systems Optronic Laboratories, Inc.
Miscellaneous Test Equipment Combustion, Tachometers, Hygrometers The materials included in this compilation are for the use of Dwyer Instruments,
Report on CIE Division 2 CIE Session 2007 Beijing.
CP5000 ‘ColorPro’ Color Analyzer
State of Engineering in Precision Agriculture, Boundaries and Limits for Agronomy.
SPECTRAL PRODUCTS INTRODUCTION 111 Highland Drive, Putnam, CT 06260, USA (East Office) 2659A Pan American Freeway NE, Albuquerque, NM 87107, USA (West.
아이알브이테크 1 IRV-TECH 아이알브이테크 May 12, 2015 IRV-65B Light Source.
The F3+ has been updated over the original F3 with a whole range of new features, and is more powerful than ever before – the world’s most powerful single.
Scanner.
Illumination Devices Measurement Unit.
Digital Light Sources First introduced in 2001.
Why OttLite? Range Proposal. Why OttLite? Range Proposal.
Precise Print Color Control
Meco A Milli-Ohm Meter with Software
Lighting Passport GateKeeper Quick Guide
To change picture – with LCD view.
Color & Light CMSC 435/634.
FRED A software tool for modern optical engineering
THE FUTURE OF LIGHT MEASUREMENT
Complex Nanophotonics
High Accuracy UV-VIS Spectroradiometer ( nm)
OL 750 Measurement Systems
Future of light measurement
Shanghai Institute of Technical Physics , Chinese Academy of Science
Palm-Top USB Radiometer/Photometer
OL 750 Spectroradiometer & Linear Spectral Transmission Measurements
PowerLogic ION6200 Power and energy meter.
Presentation transcript:

GS-1150 HANDHELD SPECTROPHOTOMETER

ABOUT GAMMA SCIENTIFIC With over 50 years of experience in developing commercial light measurement instruments, Gamma Scientific is trusted by the world’s leading organizations to provide accurate and reliable results.Gamma Scientific Gamma Scientific also operates an ISO compliant, NVLAP accredited laboratory that performs ENERGY STAR® lighting certification and LM-79 testing.

GS-1150 HANDHELD ILLUMINANCE SPECTROPHOTOMETER  The GS-1150 is a versatile handheld, battery-powered illuminance spectrophotometer and spectral light meter  The GS-1150 uniquely combines the capability and accuracy of a desktop spectrophotometer into a compact and portable handheld unit  Operated by using a color touchscreen, it is designed for engineers, designers, calibrators and lighting installers who require accurate portable spectral measurements

GS-1150 ILLUMINANCE SPECTROPHOTOMETER  The GS-1150 is based on a compact Czerny-Turner design spectrophotometer with a 2048 element linear CCD array. This enables it to measure light intensity and color with 0.2nm resolution  The high resolution CCD array provides accurate measurements of narrow bandwidth light sources such as LEDs, OLEDs, LED Displays and general lighting  Multiple calibrations for different applications can be stored on the same unit  NIST traceable calibration On/Off Power input Mini USB Cosine diffuser 5” touchscreen

SAMPLE APPLICATIONS  Architectural lighting and installation measurements  Automotive lighting  Display booth color and brightness  General lighting color and brightness  Signage lighting  Street light illumination  Photography lighting  UVA and UVB measurements. (Requires UV model)

GS-1150 MEASUREMENT CAPABILITIES  Measurement capabilities:  Illuminance – Lux  Luminance – Nits, Lumens and Candela with optional accessories and calibration  CRI – Color Rendering Index  Spectral Irradiance  CIE 1931 chromaticity x,y coordinates  CIE 1976 UVS u v coordinates  Peak Wavelength  Dominant Wavelength  CCT – Color Temperature

GS-1150 SOFTWARE  Clear and easy to use  All measurement parameters are easily accessible by touch operation

REPORT OUTPUT  Up to 500,000 data files can be stored  Data can be exported to a PC in Excel format and as an official measurement report

GS-1150 SPECIFICATIONS Detector TypeLinear CCD array sensor, 2048 pixel spectrometer, 29mm Cosine Receptor Diameter6.6 ± 0.1 mm (0.260 ± inch) Measurement Range50 lx – 50,000 lx Wavelength Range360 – 830 nm Exposure Time Range1 – 4000 ms Capture ModeSingle/Continuous Exposure TimeAuto Digital Resolution16 bits Dark CalibrationAuto Stray Light0.001% Wavelength Data Increment0.5 nm Wavelength Data Accuracy± 0.3 nm FWHM1 nm Illuminance Accuracy± 1% / ± 4% Color Accuracy (Illuminant A)x,y: ± Color Repeatabilityx,y: ± CCT Accuracy± 1% / ± 2% CRI Ra± 0.8% / ± 1.5% Display5″ LCD 480×800 Touch Panel Battery Operation TimeUp to 3 hours continuous use Battery3500 mAh / Rechargeable lithium ion battery Date Output Interfacemini-USB 2.0 Weight660 g (1.45 lbs) Size200mm L x 92mm W x 30mm H (7.87” L x 3.63” W x 1.18” H) Operating Temp. Range0 – 35° C (32 – 95° F)

CARRYING CASE AND POUCH

ADDITIONAL APPLICATIONS  When combined with optional accessories such as an integrating sphere or focusing lens, the GS-1150 can also measure optical parameters such as Lumens, Candela and Nits  Sample applications:  Display test and measurement. The spectroradiometer design provides accurate measurements for all display types including OLEC, LED, CFL, CRT and Projection  Transmission and reflectance measurements using optional accessories  Laser power and fiber optic power with integrating spheres  Led Test and Measurement

ADDITIONAL APPLICATIONS  LED Measurement with an Integrating Sphere Integrating Sphere  Ideal for quick testing of individual LEDs and LED lamps  Can be combined with large or small integrating spheres  Measurement parameters:  Lumens & Watts  CRI (R1 to R15)  CIE 1931 x,y coordinates  CIE 1976 UVS u v coordinates  Peak Wavelength  Dominant Wavelength  CCT

SUMMARY  The GS-1150 is a versatile and powerful portable light measurement tool built on a high resolution Czerny Turner spectrometer  The GS-1150 uniquely provides accurate color and brightness measurements from a handheld instrument  By attaching modular light collection devices, the GS-1150 can be used for many different applications  Gamma Scientific instruments are trusted by leading global organizations that require high-speed, precision measurements and custom configurations for the most challenging environments