Tokubetsu-shishin kickoff meeting, Sep-13 th 2011 Satoru Uozumi Korean Activities on Calorimetry in ILC History of Japan-Korea collaboration.

Slides:



Advertisements
Similar presentations
Recent news about SiPM based applications R&D in DESY Nicola D’Ascenzo University of Hamburg - DESY.
Advertisements

R&D of Strip/Block Scintillators E.P.Jacosalem, S.Iba, N.Nakajima, H.Ono, A.L.Sanchez, A.M.Bacala & H.Miyata GLD Calorimeter Group 8 th ACFA Workshop on.
Comparison of 3 types of scintillator strips and 2 types of reflector films Miho NISHIYAMA Shinshu-U Light yield of 3 scintillator strips have been measured.
The Multi-Pixel Photon Counter for the GLD Calorimeter Readout Jul Satoru Uozumi University of Tsukuba, Japan 1.Introduction 2.Recent.
Study of the MPPC Performance - contents - Introduction Fundamental properties microscopic laser scan –check variation within a sensor Summary and plans.
W. Clarida, HCAL Meeting, Fermilab Oct. 06 Quartz Plate Calorimeter Prototype Geant4 Simulation Progress W. Clarida The University of Iowa.
R&D status of Scintillator
Performance of MPPC using laser system Photon sensor KEK Niigata university, ILC calorimeter group Sayaka IBA, Hiroaki ONO, Paul.
1 Calice LCUK Bristol 24/03/09 David Ward WP1 : Test Beam.
Performance of new strip scintillator Jungeun Lee, Jaeyun Choi, Kyungpook National University Minseok Park.
1 Tianchi Zhao University of Washington Concept of an Active Absorber Calorimeter A Summary of LCRD 2006 Proposal A Calorimeter Based on Scintillator and.
Status of EIC Calorimeter R&D at BNL EIC Detector R&D Committee Meeting January 13, 2014 S.Boose, J.Haggerty, E.Kistenev, E,Mannel, S.Stoll, C.Woody PHENIX.
GLD Calorimeter Status Oct 学術創成会議 S. Uozumi Shinshu University FJPPL meeting held at the end of September. Preparation underway toward the ECAL.
Calorimetry: a new design 2004/Sep/15 K. Kawagoe / Kobe-U.
CALICE Meeting DESY ITEP&MEPhI status report on tile production and R&D activities Michael Danilov ITEP.
Construct two layers of hadron calorimeter and test Makoto Harada High Energy Physics Laboratory Faculty of Physics Department of Science Shinshu University.
J.S. Suh The Second Korean ILC Workshop Plastic Scintillator Detector for ILC Jun-Suhk Suh KNU/CHEP.
Beam test of scintillator strips Miho NISHIYAMA Shinshu University ・ scintillator strip calorimeter ・ Kuraray scintillator strips and KNU extruded ・ the.
Implementing a dual readout calorimeter in SLIC and testing Geant4 Physics Hans Wenzel Fermilab Friday, 2 nd October 2009 ALCPG 2009.
The MPPC Study for the GLD Calorimeter Readout Introduction Measurement of basic characteristics –Gain, Noise Rate, Cross-talk Measurement of uniformity.
The Scintillator ECAL Beam Test at FNAL Adil Khan International Linear Collider Workshop 2010 LCWS10 & ILC10, Beijing, China CALICE Scintillator ECAL group.
The Scintillator ECAL Beam Test at FNAL K. Kotera, Shinshu-u, 1st October 2009 CALICE Scintillator ECAL group; Kobe University, Kyungpook University, the.
서준석, KPS, R&D of Extruded Plastic Scintillator 서 준석 김 동희, 양 유철, 오 영도, 장 성현, 조 기현, KHAN Adil, MIAN Shabeer Ahmad ( 경북대학교 )
Future Beam Test Plans of the GLD Calorimeter Aug 学術創成会議 Satoru Uozumi (Shinshu) for the GLD calorimeter group We are planning to have two beam.
Electromagnetic Calorimeter for the CLAS12 Forward Detector S. Stepanyan (JLAB) Collaborating institutions: Yerevan Physics Institute (Armenia) James Madison.
Toward the FNAL Beam Test S. Uozumi (Kobe) May Japan-Korea meeting.
Study of the MPPC performance - R&D status for the GLD calorimeter readout – Nov 6-10.
Study of the Multi-Pixel Photon Counter for ILC calorimeter Satoru Uozumi (Kobe University) Atami Introduction of ILC and MPPC The MPPC performance.
Linear collider muon detector: Marcello Piccolo Amsterdam, April 2003.
Scintillator ECAL for ILC for Calorimeter Review DESY May2007 Tohru Takeshita (CALICE-Shinshu) Idea implementation current status future mile stones.
Scintillator-based ILC detector R & D Status and Milestone DongHee Kim Kyungpook National University Joint Korea-Japan Collaboration KPS meeting, Spring.
June 4, Scint 2007 Scintillators and ILC 1 Scintillator calorimeters at ILC Jaroslav Cvach Institute of Physics ASCR, Prague CALICE Collaboration 1.Accelerator.
KEK BT Summary &Plan Shinshu University Miho Nishiyama.
Nov Beam Catcher in KOPIO (H. Mikata Kaon mini worksyop1 Beam Catcher in the KOPIO experiment Hideki Morii (Kyoto Univ.) for the KOPIO.
R&D status of the Scintillator- strip based ECAL for the ILD Oct LCWS14 Belgrade Satoru Uozumi (KNU) For the CALICE collaboration Scintillator strips.
SCECAL progress report Tohru Takeshita (Shinshu) _DESY Beam Test summary _improvements for FNAL BT _FNAL module _current status at Fermilab.
Status of photon sensor study at Niigata University -- SiPM and MPPC -- Photon sensor mini workshop 05/9/16 University Niigata University.
Study of the MPPC for the GLD Calorimeter Readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group (KNU, Kobe, Niigata, Shinshu, ICEPP.
DESY Beam Test of a EM Calorimeter Prototype with Extruded Scintillator Strips DongHee Kim Kyungpook National University Daegu, South Korea.
ILC Calorimetry Test Beam Status Lei Xia ANL HEP.
Multipixel Geiger mode photo-sensors (MRS APD’s) Yury Kudenko ISS meeting, KEK, 25 January 2006 INR, Moscow.
Scintillator tile – SiPM development at ITEP Michael Danilov, ITEP CALICE Meeting, Casablanca, 23 Sep 2010.
SiPM for CBM Michael Danilov ITEP(Moscow) Muon Detector and/or Preshower CBM Meeting ITEP
Systematics on ScECAL 1 st prototype DESY Apr , CALICE Satoru Uozumi for the CALICE collaboration NIM A, 763 (2014) 278.
ScECAL Beam FNAL Short summary & Introduction to analysis S. Uozumi Nov ScECAL meeting.
Short report on MPPC gain monitoring system S. Uozumi Jun ScECAL meeting At the FNAL BT, having the gain monitoring system for all the channel.
The 2 nd SCECAL module for the Fermilab beam test - tentative idea - S. Uozumi (Shinshu) Jun GLDCAL meeting Next beam test will be held likely.
DESY Beam Test of a EM Calorimeter Prototype with Extruded Strip Scintillator DongHee Kim Kyungpook National University Daegu, South Korea.
06 FEB th ACFA Development of fine strip scintillator with extrusion technique SungHyun Chang, DongHee Kim, Jun Suhk Suh, Youngdo Oh, Daejung Kong,
Status of E14 G.Y.Lim IPNS, KEK. E14 Experiment Step-by-step approach to precise measurement of Br( K L    ) KEK-PS E391a J-PARC E14 (Step-1) J-PARC.
Taikan SUEHARA et al., LCWS2007 & DESY, 2007/06/01 R&D Status of ATF2 IP Beam Size Monitor (Shintake Monitor) Taikan SUEHARA, H.Yoda, M.Oroku,
Performance of Scintillator-Strip Electromagnetic Calorimeter for the ILC experiment Satoru Uozumi (Kobe University) for the CALICE collaboration Mar 12.
Jet Energy Measurement at ILC Separation of jet particles in the calorimeter is required for the PFA  Fine granular calorimeter is necessary. Particle.
The KNU-WCU Scintillator Laboratory The WCU Collider Physics Research Group in Kyungpook National University Jets from more massive particles decay 1.Introduction.
The Multi-Pixel Photon Counter for the GLD Calorimeter Readout Jul Satoru Uozumi University of Tsukuba, Japan for the GLD Calorimeter.
Short Summary of the Japan- Korea KNU Oct GLDCAL meeting S. Uozumi (Shinshu) 3 rd Japan-Korea joint meeting is held on Oct at Kyunpook.
The Scintillator-ECAL 2 nd Prototype S. Uozumi (Kobe) Jun
The ILD ECAL Jan th 2010 Paris Satoru Uozumi (Kyungpook Natl. Univ.) for the ILD ECAL group.
Study and Development of the Multi-Pixel Photon Counter for the GLD Calorimeter Satoru Uozumi (Shinshu, Japan) on behalf of the GLD Calorimeter Group Oct-9.
The KNU-WCU Scintillator Laboratory The WCU Collider Physics Research Group in Kyungpook National University Jets from more massive particles decay 1.Introduction.
Study of the MPPC for the GLD Calorimeter Readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group Kobe Introduction Performance.
Plan for the KEK beam test in November 2007 and Beyond Satoru Uozumi (Shinshu) Oct-1 Japan-Korea KNU.
I nstrumentation of the F orward R egion Collaboration High precision design ECFA - Durham2004 University of Colorado AGH University, Cracow I nstitute.
Status Report of Tile Calorimeter at Korea Calorimeter meeting 2005/6/13 Youngdo Oh Kyungpook National University.
Simulation and reconstruction of CLAS12 Electromagnetic Calorimeter in GSIM12 S. Stepanyan (JLAB), N. Dashyan (YerPhI) CLAS12 Detector workshop, February.
Future Beam Test Plans of the Calorimeter Group Aug 学術創成会議 Satoru Uozumi (Shinshu) for the GLD calorimeter group We are planning to have two beam.
Scintillator-ECAL Beam Test Scintillator-strip ECAL Beam DESY My task and achievement at DESY Contents Satoru Uozumi Shinshu University, Japan Nov-23.
ILC Detector Activities in Korea
ScECAL+AHCAL+TCMT Combined Beam FNAL
The MPPC Study for the GLD Calorimeter Readout
Presentation transcript:

Tokubetsu-shishin kickoff meeting, Sep-13 th 2011 Satoru Uozumi Korean Activities on Calorimetry in ILC History of Japan-Korea collaboration Current R&D and funding status Prospects (yet rough)

History The Japan-Korea (Kyungpook National Univ.) collaboration has more than several years of history. The KNU is dedicated to scintillator-strip production by extrusion technique It allows suppressing production costs while keeping necessary performance.

The KNU Scintillator-Lab overview The KNU has a production & bench-test system to develop extruded plastic scintillator strips. The laboratory is capable to study : – Performance of various scintillators (types, dimensions, configurations). – General optical simulation to reproduce the results of the measurements. So far we have successful to produce scintillator strips for two ScECAL technical prototypes.

Plastic scintillator strip by extrusion technique Multi-Pixel Photon Counter (MPPC) Absolute amount of light Response uniformity Effect of covering material Transparency Mechanical stability Production cost Configuration change to 2mm thick with MPPC direct coupling Current base design of the scintillator-strip for the ILD calorimeter 5 x 45 x 2 mm Thickness 2mm 3mm

Extruded Scintillator Production by KNU Extruded scintillator Extruder and die Extrusion system at Misung Co.

Setup of the Bench Test Systems in the Scintillator Laboratory Precise 2-D scanning system with collimated beta-ray to measure scintillator light output and its position dependence. Collimated  - ray Automated 2-D scanning system MPPC Strip scintillator Readout electronics (ADC) Target scintillator Trigger scintillator MPPC

Tungsten (3.5 mm thick) Scintillator layer (3 mm thick) Test of the 2 nd prototype at Fermilab Sep 2008 / May cm 72 strips x 30 layers Test of the first ScECAL prototype at DESY March 2007 Build with 10 mm width scintillator with readout fiber

Current status in KNU lab Funding To narrower and thinner strips

Funding : The WCU Collider Physics Program in KNU Since 2009 till 2013 (extension is being considered) Funding for wide physics and detector R & D Several research prof., postdocs and students Working on CDF, CMS, ILC and Super-KEKB Professor Teruki Kamon Texas A&M U/KNU Professor Satoru Uozumi KNU Foreign Scholars Professor DongHee Kim Professor Hwanbae Park Professor HongJoo Kim KNU Scholars

Current result (a highlight) Thickness 2 mm Thickness 3 mm Comparison of the Thickness of strip Keeping other configurations same Comparison of strips with 5 x 45 mm wide, 2 and 3 mm thick

5) Thickness : 3mm vs 2mm(Direct readout) Thickness 2mm Thickness 3mm The 5 x 45 x 2 mm strip shows almost comparable and sufficient performance with others ! ~ ~120

We are aiming to establish the scintillator strip performance by a systematic measurement with various configurations : – Quality of the scintillator – mechanical stability / precision – Dimensions of the strip – Covering materials (reflector) – Photo-sensor performance Prospects (yet rough, will be discussed more) For next technological prototype, we will need detailed discussion on collaborative work betweek Japan and KNU teams. Songyungwan Univ. is also a member of SiW-ECAL, may have a room for future collabolative work.

Summary We are having successful collaborative efforts with Japan and KNU teams to develop the ILD calorimeter. Extensive R&D effort is still ongoing for the test of scintillator-strip calorimeter in close collaboration. KNU team is aiming to establish the scintillator-strip production & performance with final strip configuration for the ILD calorimeter. The scintillator-laboratory is set up in KNU under WCU funding since Systematic measurement of various types, shapes of scintillators are ongoing. Results obtained so far shows are in good shape. Establishment of detailed production technology will be followed by collaborative work for next technological prototype.

Backups

Setup of the Bench Test Systems in the Scintillator Laboratory Establishing the photo-sensor performance is also important ! The system is capable to measure following properties of the MPPC. - Gain - Dark noise rate - Dynamic range ADC Gate Signal Electric pulse LED MPPC Precise 2-D scanning system with collimated beta-ray to measure scintillator light output and its position dependence. Collimated  - ray Automated 2-D scanning system MPPC Strip scintillator Readout electronics (ADC) Light shield

Plastic Scintillator for the strip production Base transparent material : poly-stirol - with a dopant like p-Terphenyl or POPOP, etc... Energy deposit by passing charged particles is converted to photons by those scintillation dopants. The molecular excitation and photon emission occur in order of sub-nano second. fast response, good timing resolution scintillation light wavelength ~ nm (ultra violet – violet region).

Advantages of the Scintillator-based Detector Robustness, production and handling of the scintillators are well established in past experiments – Various scintillators are commonly used in last 40 years for radiation detection and high energy experiments. Cost effective – Especially for the plastic scintillators, general forming method (extrusion, injection mould) can be used. – Photo-sensor price will also be order of $2-3 / piece. Neutron sensitive (in organic scintillator case) – for hadronic cascade shower, neutrons bring 10-30% of whole incident particle energy. Those neutrons can be efficiently detected by the organic scintillators.

Performance of extruded scintillator-strips with various configurations has been measured at KEK. Precise 2-dimensional scanning has been performed to evaluate amount of light signal, hitting position dependence of the strips. Test of scintillator-strips performance (Nov-2007 at KEK Fuji electron beamline) Semiconductor Tracker Scintillator strips Movable stage 3 GeV e - beam

A B C D E F beam Tested Strips typeMethodRead- out Cover Thickness (mm) A1 Extruded Fiber TiO 2 3 No fiber A2good matching B1 Reflector big fiber hole B2matched hole size CDirectTiO 2 D Kuraray Direct Reflector 2 E 3 FFiber reference A1,A2,….,F

extruded TiO 2 No fiber extruded TiO 2 good matching extruded reflector bad matching extruded reflector good matching extruded TiO 2 Kuraray reflector thickness:2mm Kuraray reflector Kuraray reflector reference Beam position (mm) Strength of light signal (arbitrary unit) Test results so far

4) With fiber vs Direct readout (5mm) Strip2 (Direct readout) Strip1 (fiber) Comparison of the existence of fiber Compare strip with fiber and direct readout while other conditions are same

Strip 1 With fiber Strip 2 Direct readout 4) With fiber vs Direct readout(5mm) The strip1 with fiber gets lower Light yield than strip2 But uniformity is better ~ ~60

What we have been done so far with the ScECAL R&D We have produced first version of base components (extruded scintillator strip + MPPC) with reasonable performance. Variation of the strip performance with some different configurations (covering material, mechanical stability, thickness, etc…) has been tested in some extents. Tests of the 1 st and 2 nd prototypes prove reasonable performance of the ScECAL. – Observing shower shape with the fine granular calorimeter. – Obtained performance comparable with computer simulation.

Establishment of Photon Transfer Simulation Developing reliable optical simulation makes any scintillation detector designs much easier. Simulation will be based on a simple ray-tracing method with various material parameters. Simulation results will be compared with actual measurements at the scintillator-laboratory. Reflector Photo sensor

Going to even finer segmentation (1 cm 5 mm width, without WLS fiber) Jet energy resolution by Particle Flow with different segmentation size M. ThomsonFirst test result with 3 mm thick machined scintillator