Fire Sprinkler Systems for New One- and Two-Family Homes.

Slides:



Advertisements
Similar presentations
Residential Fire Sprinklers. What is the leading cause of fire? Men Men Women Women Children Children.
Advertisements

Initiating Devices Manual Fire Alarm Boxes Ionization Smoke Detectors
“Fires in improperly secured vacant or abandoned buildings are a constant threat to firefighters, citizens and private property alike. We believe that.
Guidelines and Required Codes That Affect Building Design
DEPARTMENT OF DEVELOPMENT SERVICES BUILDING DIVISION Ronald L. Lynn, Director/Building Official Gregory J. Franklin, Assistant Director Neil Burning, Manager.
Policy and Social Change for Healthier Designs in Building Sustainable Fire Safe Homes Princella Lee-Bridges, MSN, RN Bridges From Augusta, Inc. Tim Travers.
Minnesota Department of Public Safety State Fire Marshal Division Fire Safety & Prevention.
Wet Sprinkler Systems Identifying components of, and inspection and testing procedures.
Chapter 20 Plumbing Plans.
N.F.P.A. 13R Justin Bohlmann FIR-204.
13D Systems What, Why and How Oregon Fire Sprinkler Coalition.
Residential Fire Sprinklers A Little Bit of History and The What, Where, Who, When and How Questions Richard J. Prospal – American Society of Sanitary.
Residential Fire Sprinklers in the 2010 CA Codes
RESIDENTIAL FIRE SPRINKLER SYSTEMS
FIRE SAFETY TRAINING THE LOSS PREVENTION UNIT OF THE OFFICE OF RISK MANAGEMENT.
City of Blaine Residential Fire Sprinklers Your Personal Fire Fighter =
AUTOMATIC SPRINKLERS.
Fire Sprinklers A Presentation to the Canadian Home Builders Association Technical Research Committee Sean Pearce National Marketing Manager Canadian Automatic.
Means of Egress and Fire Protection. 2 Objectives Understand Alarms and Warning Devices Know the location of Exits and Exit Routes Understand the RACE.
Paris, 31 January 2008 Alan Brinson Contribution of Sprinkler Systems to Fire Safety.
1 Residential Fire Sprinklers International Residential Code Change for 2011 Provides fire safety sprinklers in 1 & 2 Family Dwelling.
2012 International Fire Code Adopted as the minimum fire safety standard by the State of Wyoming City of Sheridan must adopt the minimum standard to retain.
FIRE DESIGN OF BUILDINGS VULNERABLE GROUPS. COMPONENTS OF FIRE building materials unattended stoves Loose electrical connections overloaded electrical.
Residential Fire Sprinkler Systems. Goal Provide entry level firefighters with an understanding of residential fire sprinkler system Provide entry level.
Home Fire Sprinkler Mythbusters Overcoming Barriers Oregon Fire Sprinkler Coalition.
CVFD Training – Fire Protection Systems
FALAR Part 3 – Post Construction  Compilation of  Maintenance records of fire protection/life safety equipment  Test records of fire protection/life.
CNG STATION & GARAGE MODIFICATION CODES & STANDARDS Graham Barker Business Development Manager.
Module C Sprinkler systems (4-20)
Protect What You Value Most. Today’s presentation will help you understand how home fire sprinklers can: Save livesSave lives Reduce injuriesReduce injuries.
Learning Objective 1 Explain the ways water supply system components are used by firefighters.
Fresno County Fire Protection District. Fire Sprinklers Systems Residential – 13D October 30, 2007.
EGRESS AND FIRE PROTECTION
Church Administrators & Emergency Planning
NFPA 31 Standard for the installation of Oil- Burning Equipment
Placing Vapor Distribution Systems and Appliances into Operation MODULE 8 System Tests.
MODULE:3 FIRE CONFINMENT AND EXTINGUISHMENT. OBJECTIVES Module 3 Select and deploy the appropriate hose lines to accomplish fire confinement and extinguishment.
Means of Egress and Fire Protection
© 2008 Delmar, Cengage Learning Property Security, Emergency Response, and Fire Protection Systems Chapter 13.
Week 1 Seminar Chapter Firefighter Fatalities in the United States 1.
MODULE:3 FIRE CONFINMENT AND EXTINGUISHMENT. OBJECTIVES Module 3 Overview Select and deploy the appropriate hose lines to accomplish fire confinement.
Fire Safety Month Fire Safety Tips for October Department of Risk Management James Madison University.
Chapter 5-Fire Safety Developing Effect Ways to Prevent and Deal With Fires in Your Home.
1 HVACR318 – Refrigeration II International Mechanical Code Relating to Refrigeration.
NEW TECHNOLOGY FOR FIRE AND BURN SAFETY DAVID J. BARILLO, MD, FACS MEDICAL UNVERSITY OF SOUTH CAROLINA CHARLESTON, SOUTH CAROLINA.
Means of Egress and Fire Protection. Introduction Fires and explosions kill more than 200 and injure more than 5,000 workers each year There is a long.
Advocating Residential Fire Sprinklers
Fire Protection Systems Chapter 6. Fire Protection Systems Most of the time you will work with an electrical engineer or fire-protection designer to coordinate.
Chapter 5 ID 234 Building Codes Fire Resistant Materials and Assemblies.
Exit Routes and Fire Protection
Maine State Fire Marshals Office1 Laws and Codes Relating to Existing Apartment occupancies in the State of Maine Mark Stevens CFI-II, CFPS, CFPE Inspections.
Sprinkler Loads on Trusses
Residential Fire Sprinklers for Compact Development.
Residential Fire Sprinklers Realtor Education
Residential Fire Sprinkler Systems Insurance Industry Perspective Scott Kramer, State Farm Insurance.
Sprinkler Loads on Trusses Educational Presentation.
Are you ready? Citizen Emergency Preparedness.  You are responsible for your own safety EVEN during an emergency.  You are expected to be self sufficient.
 There are 70,000 fires each year in Canada  Preventing fires will lessen the chance of injury or death  Knowing what to do in case of fire can save.
FIRE SAFETY & SUPPRESSION C ERT Unit 2. The Red Cross responded to 74,000 disasters last year and 93% were fires.
Fundamental Concepts for Design of Special Hazard and Fire Alarm Systems Chapter 1.
Process Safety Management Soft Skills Programme Nexus Alliance Ltd.
Exit Routes, Emergency Action Plans, Fire Prevention Plans, and Fire Protection.
To Sprinkle or Not to Sprinkle, That is the question
Home Fire Preparedness
What Realtors Should Know
AUTOMATIC SPRINKLERS.
Chapter 19 Electrical Plans.
Fire Service Professionals
Building standards Mr. Da Silva.
Presentation transcript:

Fire Sprinkler Systems for New One- and Two-Family Homes

About the Home Fire Sprinkler Coalition (HFSC) HFSC is a national nonprofit 501(c)(3) organization focused solely on education about the life-safety value of installing fire sprinkler systems in new houses. HFSC does not lobby for code adoptions, or promote any sprinkler industry product, service or installation. HFSC earned a competitive Fire Prevention & Safety Grant to develop and distribute this course. This generous grant is awarded as part of the national Assistance to Firefighters Grants, managed under the Grant Programs Directorate in the Federal Emergency Management Agency.

Learning Objectives 1.Recognize the documented life-safety ramifications of unwanted fire in homes and describe the superior fire protection that fire sprinkler systems bring to residents, firefighters and at-risk populations. 2.Describe the basics of home fire sprinkler operation and care/maintenance, and be conversant in the installation process and interaction with the fire sprinkler contractor, building official and water purveyor, and have a basic understanding of relevant national standards and codes. 3.Describe how water is supplied to a home fire sprinkler system in differing circumstances, recognize the varied water supply options, and become familiar with water supply components. 4.Recognize common myths and know the facts about home fire sprinklers.

Home Fire Dangers Fire does not discriminate; it kills more people in the U.S. annually than all natural disasters combined. –According to the National Fire Protection Association (NFPA), fire is more common and often more deadly than hurricanes, tornados and other disasters. More than 3,000 people perish in fires each year –Most fire deaths occur in the very place where people feel safest – their homes. –Fire sprinklers are mandatory in most public buildings, and people are now demanding the same level of protection for their homes.

Each Sprinkler is Individually Activated by Heat Not the entire system activates Smoke will not activate a sprinkler

Home Fire Sprinklers Save Lives Research conducted by the National Institute of Standards and Technology (NIST) has shown that home fires become deadly in as few as three minutes. “Fires today seem to burn faster and kill quicker, because the contents of modern homes (such as furnishings) can burn faster and more intensely...” - NIST senior engineer Richard Bukowski, P.E.

Home Fire Sprinkler Basics With a home fire sprinkler system Smoke alarm sounded at 30 seconds. Fire sprinkler activated at 90 seconds. Without a home fire sprinkler system Flashover (simultaneous ignition of combustible material in the area) occurred in only 3-5 minutes.

Case Study: Prince George’s County, Maryland Prince George’s County, Maryland* –15-year study from 1992 through 2007 –Recorded 13,494 single-family home and townhouse fires Homes with Fire Sprinkler Systems –245 homes were protected with fire sprinkler systems –No deaths and only 6 injuries reported Homes without Fire Sprinkler Systems –13,249 homes were not protected with fire sprinkler systems –101 deaths and 328 injuries reported

Case Study: Prince George’s County, Maryland Thousands of Dollars Fires with no sprinklers/ no fatalities Fires with no sprinklers/ with fatalities Fires in homes protected with fire sprinklers Another important advantage of home fire sprinklers is property protection. From , the fire department recorded $134,711,199 of damage due to fire loss for single-family homes and townhouses.

Today’s Homes Burn Quicker Reduced risk of injury –Modern homes are made with lightweight materials that tend to burn more quickly, increasing risk of structural collapse Reduced risk of death related to structural collapse –In unsprinklered homes, firefighters don’t know what kind of fire situation they are walking into

NFPA 13D Standard for the Installation of Sprinkler Systems in One- and Two-Family Dwellings and Manufactured Homes In accordance with NFPA 13D, Fire Sprinklers are Expected to: –Aid in the detection and control of home fires; –Provide improved protection against injury and life loss; –Prevent flashover (total simultaneous ignition of combustible materials) in the room of fire origin; and –Improve the chance for occupants to escape or to be evacuated.

NFPA 13D Compliance with NFPA 13D is intended to prevent injury and life loss. The standard requires at least 10 minutes of sprinkler water on the fire in its initial stage of development. –Time to exit safely –Time for fire department to respond A single fire sprinkler flows approximately 15 gallons per minute.

NFPA 13D Requirements NFPA 13D requires fire sprinklers to be installed only in living areas. The standard does not require fire sprinklers in: bathrooms less than 55 sq ft., certain small closets or pantries; garages, carports or attached open structures (porches), attics, crawl spaces and concealed spaces not used for living purposes, storage or mechanical equipment; entrance vestibules that are not the only means of egress. Local building authorities may have requirements that exceed NFPA 13D, so it is necessary to determine local requirements ahead of time.

NFPA 13D Accepted Systems Two common types of fire sprinkler systems acceptable under NFPA 13D: –Stand-alone, or independent systems separate piping for fire sprinkler system and domestic water supply –Multipurpose, or combined (network) systems same piping used for household cold water and fire sprinkler system

NFPA 13D: Water Supply When the water supply is a well, or there is not enough water pressure, a holding tank is used. A pump and a 300-gallon tank provide the 10 minutes of water supply required by NFPA 13D.

NFPA 13D Components: Fire Sprinklers The fire sprinkler system designer determines the piping design and the appropriate number, type, and layout of sprinklers along the piping. In many rooms a single fire sprinkler can protect the room. –Fire sprinklers typically cover a minimum 12 x 12-foot area –Extended-range fire sprinklers cover up to a 20 x 20-foot area

NFPA 13D Components: Piping Home fire sprinklers have become more economical and easier to install. Chloro-polyvinyl chloride (CPVC) piping, cross-linked polyethylene (PEX) tubing and other listed non-metallic piping simplify installation

NFPA 13D Components: Piping NFPA 13D includes information for installation of fire sprinkler systems in areas where freezing may occur. When freezing is a concern, pipe can be installed in interior walls using sidewall fire sprinklers. In finished attics and in warm regions, pipe can be run up into the attic and ceiling fire sprinklers can be used.

Typical Fire Sprinkler Water Supply In a typical stand-alone system the water supply for the fire sprinklers comes from the household water main –There will be a T-connection between the main and the water meter, feeding water to the fire sprinklers. This is called the riser –Riser includes the pressure gauge, a flow switch, a backflow valve (where required), and the test and drain assembly

Inconspicuous Fire Sprinklers Today's home fire sprinklers are inconspicuous – smaller than recessed lighting or smoke alarms. Can be custom-painted by manufacturer and concealed beneath color- matched plates

NFPA Maintenance Recommendations Once a month: –Check to be sure all valves are open. –If you have a water storage tank, make sure it is full. –Test the pump (if you have one), to be sure it starts. Twice a year: –If you have a water flow device, test it and your monitoring service (if any). Year-Round –Look at all fire sprinklers and inspect any visible pipes to make sure nothing is hanging from them. Make sure nothing is obstructing any fire sprinkler.

Trade-Up Options Many municipalities offer what’s known as “trade ups” for developers who include fire sprinklers in new homes. Street Width Reduction –Traffic lanes may be narrowed, substantially reducing the amount of pavement in every linear foot of street in the development. Longer Dead-End Streets –Dead-end streets may be increased in length, allowing additional building lots to be accessed. Tee Turnarounds Permitted –The permitted use of tee turnarounds in sprinklered developments can create at least one additional lot per cul-de- sac. Increased Street Grades and Building Setbacks –Steeper street grades and building locations further from paved vehicle access may be permitted. Other trade ups include additional units and increased hydrant spacing.

Trade-Up Options Building code alternatives may further offset installation costs. –Reduction in fire-rated portioning requirements between living spaces and other spaces

Environmental Impact of Fire Sprinklers An HFSC and FM Global study explored the environmental impacts of sprinklered and non-sprinklered homes. The testing examined: –Types, quantity and duration of air and water pollutants –Water uses from fire sprinklers vs. firefighter hoses –Impact of burning household furnishings –Carbon footprint of rebuilding

Environmental Impact of Fire Sprinklers This research proved that automatic fire sprinklers: Reduced greenhouse gases by 98% Reduced water usage by up to 91% Reduced fire damage by up to 97% Reduced water pollution Damage Findings Unsprinklered room = 100% damage Sprinklered room = 3% damage

Water Usage: Fire Sprinklers vs. Fire Hoses A report documenting home fire sprinkler installation in Scottsdale, Arizona, found that a fire sprinkler uses, on average, 341 gallons of water to control a fire. –Firefighters, on average, use 2,935 gallons of water That’s more than 8½ times the water use to contain and fight a home fire

Refuting Myths Myth: The water damage from fire sprinklers is worse than a fire. Fact: A fire sprinkler activates during the early stages of a fire before it grows and spreads. It controls a fire with only a tiny fraction of the water used by fire department hoses. Myth: Fire sprinklers go off accidentally, causing unnecessary water damage. Fact: Fire sprinklers are individually activated by the extreme heat of a fire. Smoke from burnt toast or cooking will not activate a fire sprinkler. Myth: Fire sprinklers operate all at once, flooding every room in the house. Fact: Fire sprinklers activate independently; only the fire sprinkler closest to the fire will activate, spraying water directly on the fire, not the rest of the house. Myth: Fire sprinklers will leak. Fact: Fire sprinklers are no more likely to leak than the other plumbing in a home.

Refuting Myths Myth: Fire sprinklers are ugly. Fact: Modern home fire sprinklers are inconspicuous and can be mounted flush with walls or ceilings. Some fire sprinklers can even be concealed. Myth: Fire sprinklers will freeze in the winter. Fact: When correctly installed according to NFPA 13D guidelines, freezing is not an issue. Methods include installing fire sprinkler piping in interior walls and avoiding unheated attics. Myth: Smoke alarms are all a home needs. Fact: Smoke alarms are essential in every home. But they can only detect a fire and signal a warning. Fire sprinklers detect the fire and automatically control it. Myth: Fire sprinklers cost too much. Fact: Increasing demand is driving the cost down. Research by the nonprofit Fire Protection Research Foundation reports that the national average is $1.61 per sprinklered square foot. Fire sprinklers increase a home's value and marketability.

Summary Fires kill more people in the U.S. every year than all natural disasters combined. Installing both smoke alarms and a fire sprinkler system reduces the risk of death in a home fire by 83%, relative to having neither. Remember, only the fire sprinkler closest to the fire will activate, spraying water directly on the fire. According to the Scottsdale, Arizona report, fire hoses, on average, use more than 8½ times the water that fire sprinklers do to contain a fire. The likelihood that a fire sprinkler will accidently discharge because of a manufacturing defect is extremely rare. Modern home fire sprinklers provide unobtrusive protection.

Summary Fire sprinklers can save money for developers, builders, homeowners, and communities. Fire sprinklers benefit communities by: Protecting residents for generations Protecting firefighters Reducing insurance costs Increasing the value of the house/development/community Helping real estate professionals sell homes Protecting the environment

Resources Home Fire Sprinkler Coalition (HFSC): National Fire Protection Association (NFPA): Prince George’s County, Maryland Case Study: officials officials FM Global study on the “Environmental Impact of Automatic Fire Sprinklers”: Underwriters Laboratories (UL): materials/fire/fireservice/lightweight/ materials/fire/fireservice/lightweight/

Thank you Please contact us with questions: