FM Global Warehouse Fires & Pre-Fire Planning Gary Keith Vice President Engineering Standards Manager.

Slides:



Advertisements
Similar presentations
Report on Fire Suppression Research for High-Density
Advertisements

Basics of Fire Sprinkler Design
Risk Assessment for Cultural Institutions: Fire Testing vs Computer Modeling Frederick W. Mowrer, Ph.D., P.E. Department of Fire Protection Engineering.
SPRINKLER PROTECTION IN ATRIUM SPACES, IS DELUGE AN OPTION?
Future Hazard Analysis in EN ‘Occupancy and Storage Classification’
FCIA CODE EFFORTS FCIA Spring Conference 2003 By William E. Koffel, P.E. Koffel Associates, Inc.
Automatic Nozzles. 1960’s & 70’s  Automatic pressure regulating nozzles invented 1960’s & 70’s  Automatic pressure regulating nozzles invented Hand.
1 Expertly Engineering Safety From Fire NFPA 25 As A Means to Improve Sprinkler System Reliability William E. Koffel, P.E., FSFPE President Koffel Associates,
Chapter 12 Systems and Equipment for Fire Protection.
Module 4: Storage and Dispensing Locations. 2 Objective Upon the successful completion of this module, participants will be able to discuss common and.
N.F.P.A. 13R Justin Bohlmann FIR-204.
Residential Fire Sprinklers A Little Bit of History and The What, Where, Who, When and How Questions Richard J. Prospal – American Society of Sanitary.
Fire Sprinkler Earthquake Protection – Sway Bracing
Reactive Hazards Management
Why In-Rack Sprinklers?
Hydrogen Workshop for Fleet Operators. Module 3, “Vehicle Operations and Maintenance Facilities”
NFPA Standard 1710: Organization and Deployment of Fire Suppression Operations, EMS and Special Ops The Right Description.
FIREFIGHTER I LESSON 15. SPRINKLER SYSTEM DESIGN AND OPERATION Series of sprinklers arranged to automatically distribute enough water to extinguish or.
WATER FOR FIRE PROTECTION (Chapter 26) Basic factors of fire – Rapid oxidation of combustible materials – A combination of oxygen, fuel, and heat is required.
Purpose of Standpipe and Hose Systems
Copyright © International Fire Consultants Ltd Sprinklers – An essential tool in fire engineering design Jon Pagan MA(Cantab) CEng MIFireE Director of.
Residential Fire Sprinkler Systems. Goal Provide entry level firefighters with an understanding of residential fire sprinkler system Provide entry level.
Fire Protection Engineering and Building Code Analysis Presented By: Harold D. Hicks P.E. President Use space bar or left mouse button to move through.
Automatic Sprinkler Systems
Updates to NFPA 13 What’s New in the 2013 Edition Kenneth E. Isman, P.E., F.S.F.P.E. For the European Fire Sprinkler Network’s Fire Sprinkler International.
Fire vs. Water Flow. What’s the best size for an “attack line?”  Maximum flow  Maximum mobility  Speed-How fast and how much  Ease of deployment and.
NFPA 13: Installation of Sprinkler Systems
FPF190: Fire Protection Fundamentals FPF190 Fire Protection Fundamentals 1 Code Consultant.
CNG STATION & GARAGE MODIFICATION CODES & STANDARDS Graham Barker Business Development Manager.
Module C Sprinkler systems (4-20)
Learning Objective 1 Explain the ways water supply system components are used by firefighters.
Risk Consulting REVISION TO EN and CEA 4001 EFSN – MAY 2014.
Research Affecting the Design and Use of Water-Based Fire Suppression Systems Russell P. Fleming, P.E. IFSA Technical Director.
Telecom Cabling Fire Stopping.
Technical Review Needed Fire Flow Analysis Developer Services Summit November 16, 2010 Engineering - Asset Planning Joe Dugandzic, PE.
Pre Incident Planning and Related Loss Reduction Strategies
Occupancy Classification Under NFPA 13 Examine the proposed facility and make recommendation on the Occupancy Classification Used to classify fuel loads.
SunTrust Tenant Improvements June 30, Background Current Situation Proposed Work Cost of Proposed Work Questions Presentation Outline.
FIRE PROTECTION TOPICS OF INTEREST Defense Nuclear Facilities Safety Board.
BALANCED FIRE PROTECTION: ARE SMOKE/HEAT VENTS NECESSARY FOR OCCUPANT AND FIREFIGHTER SAFETY IN ONE- STORY INDUSTRIAL AND STORAGE BUILDINGS PROTECTED BY.
Ron Pridgeon NC Division of Pollution Prevention & Environmental Assistance
Introduction to the ASD Suppression Actuation Threshold (ASAT) Calculator July _03_ASAT Calculator Sales and Marketing Introduction Presentation.
CHAPTER 12 Copyright © 2007 Thomson Delmar Learning 12.1 Protective Systems.
Prof. Kyriakos Papaioannou ARISTOTLE UNIVERSITY GREECE 7th Intern. Sprinkler Conference-Copenhagen 24-25/6/
Fire & Emergency Services Administration Chapter 6 Customer Service.
Module 3: Planning and Response. 2 Objective Upon the successful completion of this module, participants will be able to develop strategies for preplanning.
Advocating Residential Fire Sprinklers
© 2008 Delmar, Cengage Learning Fire Protection Systems and The Model Code Process Chapter 2.
1 The Case for Suppression “A view of warehouse fires from The Fire & Rescue Service” “and our endorsement of a pro-active approach to suppression systems”
NFPA 2 Overview Susan Bershad, Staff Liaison, NFPA.
Federal Aviation Administration Status of Research & Testing to Replace Halon Extinguishing Agents in Civil Aviation Douglas Ingerson Louise Speitel Constantine.
Sprinkler Loads on Trusses
ME444 ENGINEERING PIPING SYSTEM DESIGN
Fundamental Concepts for Design of Special Hazard and Fire Alarm Systems Chapter 1.
Building Construction
Washington Surveying & Rating Bureau  Who Are We?  What Do We Do?  How Does Insurance Rating Promote Sprinkler System Installations and What Obstacles.
Sprinkler Design FSE 221 – Fire Protection Systems
The South African Insurance Industry has reported fire loss figures in excess of R 6.5 Million per day ± R per hour.
Medium- and High-expansion Foam System Design
Fire Service Incidents. Today’s fire service does much more than fight fires. The Fire Service has become the primary source of emergency response and.
Smoke and Heat Venting in Sprinklered Facilities Dr. Craig Beyler.
1 Fire & Emergency Services Committee Fire Master Plan Consolidation of Recommendations Implementation Plan – Part B August 2014 – Revised September 24,
DoD Fuels Laboratory Standards UFC
Hazardous materials: What to look for
Borbotech BV • Tel.: +31(0) • •
GES SYSTEM THE IMPORTANCE OF GES SYSTEM IN BUILDING
WAREHOUSE RENTALS OF GEORGIA
ARIZONA WATER COMPANY East Sedona Water Storage Facility
Infrastructure Change
Bella Vista Fire Department Procedures on Sprinkled Buildings
Presentation transcript:

FM Global Warehouse Fires & Pre-Fire Planning Gary Keith Vice President Engineering Standards Manager

FM Global  Mutual Property Insurance Company – 1835  250 Standards  Technically-Based: –Research –Engineering Standards –FM Approvals

FM Global What Would You Expect?  Building: circa 1960; ~ 750,000 sq. ft.  Original occupancy: machine shop  Current occupancy: 20 ft. rack storage-plastic parts  Sprinklers: original ceiling-only system  Water supply: manual-start pumps Fire starts at approximately 0700 hours…

FM Global

“As warehouse configurations increase in height, include more complex rack storage configurations and continue to expand the volume of plastic packaging and commodities, the challenge to provide adequate fire protection is one that must always evolve.” Warehouse Fires & Pre-Fire Planning

FM Global Warehouse Fires & Pre-Fire Planning “Hey, it’s only property – that’s what insurance is for!”

FM Global Warehouse Fires & Pre-Fire Planning  Occupant Life Safety  Firefighter Safety  Loss to Property Tax Base

FM Global “What could be the most challenging warehouse fire?” Warehouse Fires & Pre-Fire Planning

FM Global Warehouse Fires & Pre-Fire Planning  “The Controlled Fire”  Sprinklers working effectively  Reduced visibility  Difficult to ventilate  Warehouse layout & difficult interior operations  Exact location of the seat of the fire  Coordinating sprinkler operation with manual suppression

FM Global

 Agenda  Warehouse Fire Protection  New In-Rack Sprinkler Protection Option  NFPA 1620 and FM Global Data Sheet 10-1 Warehouse Fires & Pre-Fire Planning

FM Global Outline  Evolution of in-rack sprinklers (IRAS)  Current guidance for IRAS  FM Global’s Recent IRAS Testing  New guidance for IRAS

FM Global Evolution: In-Rack Automatic Sprinklers (IRAS)

FM Global Testing with in-rack sprinklers started on October 1, 1969 and ran through January 13, Over that time a total of 49 tests with in-rack sprinklers were conducted Fire Protection Consortium for NFPA 231C Background

FM Global Since 1968, close to 60 different projects involving roughly 160 full-scale fire tests have been conducted at FM Global involving in-rack sprinkler protection Projects have included testing of:  Aerosols  Carpet  Distilled Spirits  Flammable Liquids  Hanging Garments  Lithium Batteries  Nonwovens  Tires  Class 2, 3 and 4  Cartoned Plastics  Uncartoned Plastics Background

FM Global Today’s Guidance

FM Global Ceiling-only protection is available up to: 45 ft. ceilings  Class 1-3  Cartoned Unexpanded Plastics 40 ft. ceilings  Cartoned Expanded Plastics  Uncartoned Plastics Trend towards higher storage heights Current Guidance

FM Global Maximum vertical increments for IRAS  25 ft.  Class 3  20 ft.  Cartoned Unexpanded Plastics  15 ft.  Cartoned Expanded Plastics  10 ft.  Uncartoned Plastics Current Guidance Maximum storage above IRAS  Maximum 10 ft. above top level IRAS

FM Global  Storage Height: 75 ft.  Ceiling Height: 80 ft.  Open-frame Double Row Rack  Commodity: Cartoned Unexpanded Plastics Hypothetical Warehouse Current Guidance

FM Global 10ft. X X X X X X X X X X X X X X X X X X X 4ft. Hypothetical Warehouse Current Guidance Option 1 IRAS Design:  Longitudinal only  K5.6, 165°F, QR  30 gpm  7 levels of IRAS every 10 ft.

FM Global X X X X X X X X X X X X X X X X 4ft. 20ft. Hypothetical Warehouse Current Guidance Option 2 IRAS Design:  Longitudinal and face  K5.6, 165°F, QR  30 gpm  4 levels of IRAS

FM Global Why is there resistance to install IRAS?

FM Global Why Resistance? Vulnerable to Impact

FM Global High Cost of In-Rack Sprinklers Why Resistance?

FM Global FM Global’s Recent IRAS Testing

FM Global Goal of the new IRAS test program:  Maximize vertical increments  Increase storage height above in-racks  Independent ceiling and in-rack sprinkler designs  Modular design Which will result in:  Less IRAS needed  Reduce likelihood of in-rack sprinkler damage  Reduce cost of in-rack sprinkler installations Research and Testing

FM Global New protection guidance for IRAS

FM Global Maximum Vertical Spacing ft (m) Commodity Minimum Flow GPM (L/min) # of SprinklersK Factor 30 (9) CUP and Less65 (250)6> K14 (200) CEP100 (380)6> K14 (200) UUP/UEP120 (455)10 (5 + 5)> K22 (320) 40 (12)CUP and less120 (455)6> K22 (320) New Options

FM Global Hypothetical Warehouse X X X X X X X X X X X X X 4ft. 40ft. Current Guidance New IRAS Design:  Longitudinal and face  K25.2,165°F, QR  120 gpm  1 level of IRAS

FM Global New Options  Cost −25-40% savings  Performance −Fire suppression −Taller higher hazard storage −Reduced water demand  Fewer Sprinklers in the Rack Key Benefits

FM Global  Unlimited Storage Height  Virtual Floor Concept  Independence of In-Rack and Ceiling  Maximized Storage Above Topmost In-Racks  Unlimited storage heights  Water flow < ceiling Summary Virtual Floor

FM Global What’s Next?  Data Sheet 8-9 Storage Protection −Released in July 2015  NFPA 13 −Plan to submit Public Input next cycle

FM Global Warehouse Fires & Pre-Fire Planning  Agenda  Warehouse Fire Protection  New In-Rack Sprinkler Protection Option  NFPA 1620 and FM Global Data Sheet 10-1

FM Global Warehouse Fires & Pre-Fire Planning  NFPA 1620 –Standard for Pre-Incident Planning

FM Global Warehouse Fires & Pre-Fire Planning  FM Global Data Sheet 10-1 –Pre-Incident Planning with the Public Fire Service

FM Global Warehouse Fires & Pre-Fire Planning  Fighting Fire in Sprinklered Buildings –Original: early 1990s –State Fire Academies –Two Revisions

FM Global Warehouse Fires & Pre-Fire Planning  Our “Recommendation”  Identify Target Warehouse Locations  Adopt NFPA 1620: Department Policy or Local Regulation (be familiar with FM Global Data Sheet 10-1)  Develop Co-operative Partnership:  Warehouse Owner/Operators  Property Insurance Carriers/Risk Consultants

FM Global