Gamma Beam System at ELI–NP The ELI–NP Team* ELI–NP, IFIN–HH, Bucharest–Magurele, Romania * The ELI–NP Gamma Beam System (GBS) will.

Slides:



Advertisements
Similar presentations
GOVERNMENT OF ROMANIA Structural Instruments Sectoral Operational Programme „Increase of Economic Competitiveness” “Investments for Your Future”
Advertisements

Gamma-Ray Spectra _ + The photomultiplier records the (UV) light emitted during electronic recombination in the scintillator. Therefore, the spectrum collected.
ATF2 Interaction Point Beam Size Monitor (Shintake Monitor) Status T. Yamanaka, M. Oroku, Y. Yamaguchi, S. Komamiya ( Univ. of Tokyo ), T. Suehara, Y.
Detection of Gamma-Rays and Energetic Particles
Interaction of High Energy Radiation with Matter review Two basic types Excitation electrons move to a higher orbital shell temporarily ~70% of charged.
An Advanced Linear Accelerator Facility for Microelectronic Dose Rate Studies P.E. Sokol and S.Y.Lee Indiana University.
L 35 — Modern Physics [2] X-rays How lasers work –Medical applications of lasers –Applications of high power lasers Medical imaging techniques –CAT scans.
Scint. Al Internal reflection External reflection ↑ ↑ ↑ Decay Detector Development for Giant Resonance Studies By: Gus Olson Mentor: Dr. D.H.Youngblood.
Pair Spectrometer Design Optimization Pair Spectrometer Design Optimization A. Somov, Jefferson Lab GlueX Collaboration Meeting September
Upcoming Review of the Hall D Photon Beam and Tagger Richard Jones, University of Connecticut, for the GlueX collaboration GlueX Collaboration Meeting.
Detecting Giant Monopole Resonances Peter Nguyen Advisors: Dr. Youngblood, Dr. Lui Texas A&M University Energy Loss Identifying The Particles Discovered.
Medical Imaging Mohammad Dawood Department of Computer Science University of Münster Germany.
Slide 1 Diamonds in Flash Steve Schnetzer Rd42 Collaboration Meeting May 14.
Photon Source and Tagger Richard Jones, University of Connecticut GlueX Detector ReviewOctober 20-22, 2004, Newport News presented by GlueX Tagged Beam.
Detecting Giant Monopole Resonances Peter Nguyen Advisors: Dr. Youngblood, Dr. Lui Texas A&M University.
K. Moffeit 6 Jan 2005 WORKSHOP Machine-Detector Interface at the International Linear Collider SLAC January 6-8, 2005 Polarimetry at the ILC Design issues.
ELI: Electronic Timing System (ETS) at Facility Level E L I – B L – – P R E – B.
ALPHA Storage Ring Indiana University Xiaoying Pang.
USING A MICRO FABRICATED UNDULATOR TO BRIDGE THE FOUR DECADE GAP BETWEEN REGULAR PURE PERMANENT MAGNET UNDULATORS AND INVERSE COMPTON SCATTERING SOURCES.
Gamma Beam Systems a simple introduction. Purpose of the machine Deliver a high performance photon beam: Variable energy Highly polarized High intensity.
1 A PC/Linux-based Control System with EPICS for RFGTB S. Araki, K. Hirano, J. Odagiri, T.T. Nakamura and N. Terunuma High Energy Research Accelerator.
Quality Control Rad T 110.
EuroNNAc Workshop, CERN, May 2011 External Injection at INFN-LNF ( integrating RF photo-injectors with LWFA ) Luca Serafini - INFN/Milano High Brightness.
HPS Test Run Setup Takashi Maruyama SLAC Heavy Photon Search Collaboration Meeting Thomas Jefferson National Accelerator Facility, May 26-27,
NEEP 541 Radiation Interactions Fall 2003 Jake Blanchard.
NON-SCALING FFAGs: questions needing answers Andy Wolski The Cockcroft Institute, and the University of Liverpool Department of Physics. BASROC-CONFORM.
August 2005Snowmass Workshop IP Instrumentation Wolfgang Lohmann, DESY Measurement of: Luminosity (precise and fast) Energy Polarisation.
March 2011Particle and Nuclear Physics,1 Experimental tools accelerators particle interactions with matter detectors.
Tools for Nuclear & Particle Physics Experimental Background.
The GlueX Detector 5/29/091CIPANP The GlueX Detector -- David Lawrence (JLab) David Lawrence (JLab) Electron beam accelerator continuous-wave (1497MHz,
Soft collective excitations in weakly bound nuclei studied with ELI-NP A.Krasznahorkay Inst. of Nuclear Research of the Hung. Acad. of Sci. (ATOMKI)
1 Status of EMMA Shinji Machida CCLRC/RAL/ASTeC 23 April, ffag/machida_ ppt & pdf.
Photon Diagnostic Station For TAC IR-FEL Test Facility ILHAN TAPAN* *on behalf of the TAC collaboration Uludag Universitesi, Bursa,16059, TURKEY References.
Compton/Linac based Polarized Positrons Source V. Yakimenko BNL IWLC2010, Geneva, October 18-22, 2010.
Properties of Synchrotron Radiation Presentation at JASS02 Seminar; Jordan, Oct , 2002 Herman Winick, SSRL/SLAC, Stanford University.
V.Grishin, A.Koshelev, A.Larionov A.Pushkarev, V.Seleznev, M.Sleptsov A.Sytin.
National Authority for Scientific Research IFIN-HH.
L 36 — Modern Physics [2] X-rays How lasers work –Medical applications of lasers –Applications of high power lasers Medical imaging techniques –CAT scans.
Monte Carlo methods in ADS experiments Study for state exam 2008 Mitja Majerle “Phasotron” and “Energy Plus Transmutation” setups (schematic drawings)
Development of a Gamma-Ray Beam Profile Monitor for the High-Intensity Gamma-Ray Source Thomas Regier, Department of Physics and Engineering Physics University.
MICE at STFC-RAL The International Muon Ionization Cooling Experiment -- Design, engineer and build a section of cooling channel capable of giving the.
Overview of the GlueX Tagger and Photon Beamline..
X-RAY LIGHT SOURCE BY INVERSE COMPTON SCATTERING OF CSR FLS Mar. 6 Miho Shimada High Energy Research Accelerator Organization, KEK.
February 2010 ALBA Synchrotron Light Source Francis Perez.
ELECTRON MOVING AT CONSTANT VELOCITY
GOVERNMENT OF ROMANIA Structural Instruments Sectoral Operational Programme „Increase of Economic Competitiveness” “Investments for Your Future”
Photon Source and Tagger Richard Jones, University of Connecticut GlueX Detector ReviewOctober 20-22, 2004, Newport News presented by GlueX Tagged Beam.
1 Cost Room Availability Passive Shielding Detector spheres for accelerators Radiation Detection and Measurement, JU, First Semester, (Saed Dababneh).
B. Azadegan, S. A. Mahdipour Hakim Sabzevari University
Conclusions of the Workshop Nicolae – Victor Zamfir.
Interaction Ionizing Radiation with Matter BNEN Intro William D’haeseleer BNEN - Nuclear Energy Intro W. D'haeseleer
Assessment of Physics, Applications and Construction Issues for the Proposed Magurele Short-Pulse Facility Silviu Olariu National Institute of Physics.
ELI Nuclear Physics (Romania) 1 Laser-Induced Photonuclear Physics nuclear physics methods to study laser-target interactions, new nuclear spectroscopy,
MICRO-STRIP METAL DETECTOR FOR BEAM DIAGNOSTICS PRINCIPLE OF OPERATION Passing through metal strips a beam of charged particles or synchrotron radiation.
SL_THOMSON C. Vaccarezza on behalf of the SL_Thomson team.
ESLS Workshop Nov 2015 MAX IV 3 GeV Ring Commissioning Pedro F. Tavares & Åke Andersson, on behalf of the whole MAX IV team.
g beam test of the Liquid Xe calorimeter for the MEG experiment
Silicon microstrip detector for imaging of fast processes at high intensity synchrotron radiation beam. Budker INP V.Aulchenko1,2, L.Shekhtman1,2, B.Tolochko3,2,
SPARCLAB: PW-class Ti:Sa laser+SPARC
Laser wakefield accelerated electrons
A 3D design model of the apparatus for the Laser Wakefield Acceleration of electrons at ELI-NP S. Balascuta1 , R. Dinca1 1) “Horia Hulubei” National.
In collaboration with Winthrop Brown, T.Y. Fan, Franz Kaertner,
A new-concept Absorption Calorimeter for the ELI-NP facility
Paul Scherrer Institut
DTS Fields of Interest POF IV
Advanced Research Electron Accelerator Laboratory
Interaction of Radiation with Matter
Val Kostroun and Bruce Dunham
Undulator Cavity BPM Status
Status of ELI Beamlines
Presentation transcript:

Gamma Beam System at ELI–NP The ELI–NP Team* ELI–NP, IFIN–HH, Bucharest–Magurele, Romania * The ELI–NP Gamma Beam System (GBS) will produce a very intense and brilliant gamma–ray beam with energy tunable in the range E γ = 0.2–19.5MeV, obtained from the incoherent Inverse Compton Scattering (ICS) of direct laser light off a very brilliant and intense relativistic electron beam (E e ≤ 0.72 GeV). The experiments planed to be performed with the gamma–ray system require a high–quality gamma–ray beam: bandwidth ≤ 5x10 −3, energy up to 19.5 MeV to access all GDR, total flux higher than photons/s at 100%BW, peak brilliance higher than photons/mm 2 /mrad 2 /s/(0.1% BW). High quality lasers and a high perfomance electron radio–frequency linear accelerator are combined to build a state–of–the–art device able to deliver gamma beams with unique features in the world. Gamma Beam Delivery and Diagnostics The ELIADE –ray array Gamma Beam Parameters Integrated Control System The control system of the ELI-NP project is a large-scale distributed control system based on EPICS framework. All the Input / Output Controllers (IOC) and the Operator Interfaces (OPI) are connected by an Ethernet network via the EPICS Channel Access (CA) protocol. The control system of the ELI-NP project is a large-scale distributed control system based on EPICS framework. All the Input / Output Controllers (IOC) and the Operator Interfaces (OPI) are connected by an Ethernet network via the EPICS Channel Access (CA) protocol.  L ≂ 7 o,  = 0 o Inverse Compton Scattering ELIADE stands for ELI–NP Array of DEtectors. It will comprise 8 segmented CLOVER detectors with anti–Compton shields and 4 LaBr3 scintillator detectors. It will be used for Nuclear Resonance Florescence Experiments. Main features of ELIADE: Detectors placed on two rings (90 o and 135 o ) Ring at 90 o can be turned by up to 180 o Position accuracy of the detectors is better than 1 mm Target alignment is better than 0.1 mm Main features of ELIADE: Detectors placed on two rings (90 o and 135 o ) Ring at 90 o can be turned by up to 180 o Position accuracy of the detectors is better than 1 mm Target alignment is better than 0.1 mm General Layout of the Gamma Beam System The control system includes the following subsystems: Diagnostic system Radio Frequency (RF) system Timing system Vacuum system Magnet system Laser synchronization system. The control system includes the following subsystems: Diagnostic system Radio Frequency (RF) system Timing system Vacuum system Magnet system Laser synchronization system. Complexity highlights: over 190 complex subsystems are connected to the Control System synchronisation between systems <0.5ps Complexity highlights: over 190 complex subsystems are connected to the Control System synchronisation between systems <0.5ps ELIADE is just one of the ten experiments under construction at the GBS of ELI-NP. Gamma Beam Delivery and Diagnostics are developed in synergy with EuroGammaS. Attenuator for energy and bandwidth measurements challenges: precise absorber blocks (10 μm) high vacuum radiation hardness Attenuator for energy and bandwidth measurements challenges: precise absorber blocks (10 μm) high vacuum radiation hardness Fission chamber for flux measurements characteristics: very precise machining (μm) thin layers of radioactive materials Fission chamber for flux measurements characteristics: very precise machining (μm) thin layers of radioactive materials Beam Time Structure 15 cm 2.5 m γ-beam

Gamma Beam System at ELI–NP The ELI–NP Team* ELI–NP, IFIN–HH, Bucharest–Magurele, Romania * The ELI–NP Gamma Beam System (GBS) will produce a very intense and brilliant gamma–ray beam with energy tunable in the range E γ = 0.2–19.5MeV, obtained from the incoherent Inverse Compton Scattering (ICS) of direct laser light off a very brilliant and intense relativistic electron beam (E e ≤ 0.72 GeV). The experiments planed to be performed with the gamma–ray system require a high–quality gamma–ray beam: bandwidth ≤ 5x10 −3, energy up to 19.5 MeV to access all GDR, total flux higher than photons/s at 100%BW, peak brilliance higher than photons/mm 2 /mrad 2 /s/(0.1% BW). High quality lasers and a high perfomance electron radio–frequency linear accelerator are combined to build a state–of–the–art device able to deliver gamma beams with unique features in the world. Gamma Beam Delivery and Diagnostics The ELIADE –ray array Gamma Beam Parameters Integrated Control System The control system of the ELI-NP project is a large-scale distributed control system based on EPICS framework. All the Input / Output Controllers (IOC) and the Operator Interfaces (OPI) are connected by an Ethernet network via the EPICS Channel Access (CA) protocol. The control system of the ELI-NP project is a large-scale distributed control system based on EPICS framework. All the Input / Output Controllers (IOC) and the Operator Interfaces (OPI) are connected by an Ethernet network via the EPICS Channel Access (CA) protocol.  L ≂ 7 o,  = 0 o Inverse Compton Scattering ELIADE stands for ELI–NP Array of DEtectors. It will comprise 8 segmented CLOVER detectors with anti–Compton shields and 4 LaBr3 scintillator detectors. It will be used for Nuclear Resonance Florescence Experiments. Main features of ELIADE: Detectors placed on two rings (90 o and 135 o ) Ring at 90 o can be turned by up to 180 o Position accuracy of the detectors is better than 1 mm Target alignment is better than 0.1 mm Main features of ELIADE: Detectors placed on two rings (90 o and 135 o ) Ring at 90 o can be turned by up to 180 o Position accuracy of the detectors is better than 1 mm Target alignment is better than 0.1 mm General Layout of the Gamma Beam System The control system includes the following subsystems: Diagnostic system Radio Frequency (RF) system Timing system Vacuum system Magnet system Laser synchronization system. The control system includes the following subsystems: Diagnostic system Radio Frequency (RF) system Timing system Vacuum system Magnet system Laser synchronization system. Complexity highlights: over 190 complex subsystems are connected to the Control System synchronisation between systems <0.5ps Complexity highlights: over 190 complex subsystems are connected to the Control System synchronisation between systems <0.5ps ELIADE is just one of the ten experiments under construction at the GBS of ELI-NP. Gamma Beam Delivery and Diagnostics are developed in synergy with EuroGammaS. Attenuator for energy and bandwidth measurements challenges: precise absorber blocks (10 μm) high vacuum radiation hardness Attenuator for energy and bandwidth measurements challenges: precise absorber blocks (10 μm) high vacuum radiation hardness Fission chamber for flux measurements characteristics: very precise machining (μm) thin layers of radioactive materials Fission chamber for flux measurements characteristics: very precise machining (μm) thin layers of radioactive materials Beam Time Structure 15 cm 2.5 m γ-beam