Library QA & QC Day 1, Video 3

Slides:



Advertisements
Similar presentations
RNA-seq library prep introduction
Advertisements

Genome Biology for Programmers Lecture Series: Illumina Sequencing
The Past, Present, and Future of DNA Sequencing
An Introduction to Studying Expression Data Through RNA-seq
The Good, Bad, and Ugly of Next-Gen Sequencing
V Improvements to 3kb Long Insert Size Paired-End Library Preparation Naomi Park, Lesley Shirley, Michael Quail, Harold Swerdlow Wellcome Trust Sanger.
REAL TIME PCR ………A step forward in medicine
National Center for Environmental Health Centers for Disease Control and Prevention DBS DNA Extraction, Validation & Quantitation NBS Molecular Training.
Peter Tsai Bioinformatics Institute, University of Auckland
Nucleic Acid Prep Station What we can do for you!.
RNA-Seq An alternative to microarray. Steps Grow cells or isolate tissue (brain, liver, muscle) Isolate total RNA Isolate mRNA from total RNA (poly.
RNA Lab (Isolation, quantification and qPCR analysis) MCB7300.
Transcriptomics Jim Noonan GENE 760.
The SOLiD System: Next-Generation Sequencing Overview of the SOLiD System –  Scalable  Accurate Ultra High Throughput  Flexible  Mate Pairs.
RNA-Seq An alternative to microarray. Steps Grow cells or isolate tissue (brain, liver, muscle) Isolate total RNA Isolate mRNA from total RNA (poly.
What Can You Do With qPCR?
High Throughput Sequencing
Quantifying Sample DNA. Definition Quantifying DNA: a technique to calculate the quantity (weight) of DNA (deoxyribonucleic acid) in a sample. Using a.
Final Presentation Sample Preparation Nextera TruSeq RiboZero Strand Specific Clontech smRNA 16s.
Real Time PCR = Quantitative PCR.
11 © 2009 PerkinElmer © 2010 PerkinElmer November 20, 2012 DNA Services Overview.
Diabetes and Endocrinology Research Center The BCM Microarray Core Facility: Closing the Next Generation Gap Alina Raza 1, Mylinh Hoang 1, Gayan De Silva.
Page 1 A new method for separation and characterization of Small RNA by On-Chip Electrophoresis Marc Valer Agilent Technologies, Genomics Lab-on-a-Chip.
Real-Time Quantitative RT-PCR
Mapping protein-DNA interactions by ChIP-seq Zsolt Szilagyi Institute of Biomedicine.
Brian Sanderson Molecular Biology Facility
Genomics – Next-Gen sequencing and Microarrays
Chapter 13: DNA Quantitation.  Quantitation determines the amount of human DNA present in an extract  A narrow concentration range is required to “seed”
Chromatin Immunoprecipitation DNA Sequencing (ChIP-seq)
How will new sequencing technologies enable the HMP? Elaine Mardis, Ph.D. Associate Professor of Genetics Co-Director, Genome Sequencing Center Washington.
Next-Generation Sequencing of Microbial Genomes and Metagenomes
1. 2 VARIANTS OF PCR APPLICATIONS OF PCR MECHANICS OF PCR WHAT IS PCR? PRIMER DESIGN.
Sequencing Kristian Stevens Mark Crepeau Charis Cardeno Charles H. Langley University of California, Davis Evolution.
Genomics Core Facility at UNH: High-Throughput Sequencing on the Illumina HiSeq 2500 Platform Project Consultation Sample Submission Library Creation Illumina.
Introduction to PCR Polymerase Chain Reaction
CyVerse Workshop Transcriptome Assembly. Overview of work RNA-Seq without a reference genome Generate Sequence QC and Processing Transcriptome Assembly.
Introduction to quantitative real- time PCR Veryan Codd
Sequencing Transcriptomes Do Me a SOLiD. Overview – Library Construction RNA ◦Isolate & Bioanalyze ◦rRNA Depletion ◦Fragment ◦Bioanalyze Amplified Library.
HRM Assay and Optimization 1. DNA Quality 2. Amplicon LengthAmplicon  lengths of 100–300 bp 3. Primer Selection 4. Dye Selection 5. MgCl2 Concentration.
Canadian Bioinformatics Workshops
Short Read Workshop Day 1 - Experimental Design Example 1: How to log in to vieques.
Canadian Bioinformatics Workshops
Introduction to Illumina Sequencing
Assay I HLA-DQ Alpha (A1) Haplotype. Purpose To determine which one of several known alleles is present at the HLA DQ α locus on each of an individual’s.
RAD – technology overview Baird et al PLoS ONE.
Introduction to PCR Polymerase Chain Reaction
Quality Control Metrics for DNA Sequencing
DNA Sequencing Second generation techniques
Short Read Sequencing Analysis Workshop
RNA Quantitation from RNAseq Data
Next generation sequencing
RNA-Seq for the Next Generation RNA-Seq Intro Slides
Gene expression from RNA-Seq
Lab meeting
S1 Supporting information Bioinformatic workflow and quality of the metrics Number of slides: 10.
Fosmid Library Construction Report
Israel maritime college
Introduction to NGS.
Teagasc/APC Sequencing Facility
Primers 2 primers are required for exponential amplification
Small RNA Sample Preparation
mRNA Sequencing Sample Preparation
ChIP DNA Sample Preparation
Molecular Diagnosis of Autosomal Dominant Polycystic Kidney Disease Using Next- Generation Sequencing  Adrian Y. Tan, Alber Michaeel, Genyan Liu, Olivier.
Digital Gene Expression – Tag Profiling Sample Preparation
Mass and Molar Ratios of DNA
Genomic DNA Sample Preparation
Sequence Analysis - RNA-Seq 1
RealTime-PCR.
Genomic & RNA Profiling Core Facility
Presentation transcript:

Library QA & QC Day 1, Video 3 Experimental considerations for library construction Considerations for input material Quantification by Qubit Quality control by Bioanalyzer Quantification and quality control by qPCR

Experimental considerations Single read vs. Paired end reads Read length Sequencing Depth/Coverage Replicates These will direct you to a specific platform MiSeq: 15-25M clusters per run, 50-300bp read length HiSeq v3: 150-200M clusters per lane, 50-100bp read length Coverage = bp Sequence bp Genome

Input – DNA (genomic DNA) Which method or kit to use? How much: >1 ug or <10 ng What is the quality? How will you fragment? What is your optimal insert size, does it matter? Are you concerned about amplification bias (high/low GC, etc) Other considerations: Multiplexing: how many do you need to get on one lane Is there a reference genome available?

Input - RNA Which method or kit to use? How much: >1 ug or <10 ng or single cell What is the quality? Total RNA vs. poly-A RNA vs. ribosomal removal Strand specific or not? Unlike with DNA sequencing/resequencing these questions will often depend on what question you are asking Differential expression Isoform analysis De novo transcriptome assembly

ChIP-Seq Library kits available that deal with low input, but most of the steps are performed outside of a kit Every step likely requires some optimization Antibody choice – require good signal to noise No antibody controls Crosslinking reagent and time Fragmentation

Always check the quality of your input material! gDNA: Intact, high MW DNA on agarose gel Quantify input by Qubit (fluorescent DNA and RNA assays) Check size after fragmentation on Bioanalzyer Total RNA: Run on Bioanalyzer RNA nano or RNA pico Quantify RNA by Qubit (RNA assay) Check ribosomal removal before fragmentation ChIP: check no-antibody controls Check size after fragmentation on Bioanalyzer

Quantification of DNA/RNA Use a fluorescent method – Qubit or picoGreen Dye binds specifically to dsDNA or RNA In many cases measure both DNA and RNA by Qubit Nanodrop quantification can be off by an order of magnitude! Requires ~2uL sample

Bioanalyzer – what’s the deal? Agarose gel meets microfluidics - Measures fluorescence (DNA or RNA) versus time Great for size estimates at low concentrations Great for determining quality of total RNA Not so great for quantification

Determination of input RNA quality RNA Nano (5-500 ng/uL) or RNA Pico (50-5000 pg/uL) RNA Integrity Number (RIN) indicator of quality Monitor rRNA depletion

During library construction High Sensitivity DNA chip (5-500 pg/uL) Monitor fragmentation (RNA or DNA) Check for problems: Over-amplification adapter-dimer, primer-dimer, excess primers Determine size range of final library Adapter-dimer Excess primers Over-amplification

Final QC - qPCR Primers for P5 and P7 ends of the adapters – only detect molecules with both adapters bound Requires significant dilution, can lead to large errors Final concentration calculation depends on the size of your library Adapter-dimers WILL be amplified (can check on gel after qPCR)

Comparison between methods Rarely see the same concentration by Qubit, Bioanalyzer and qPCR Ratios between qPCR:Qubit (molar) typically between 0.8-2.0 for well-performing libraries Higher ratios may indicate over-amplification or significant adapter-dimer, check the Bioanalyzer Low ratios may indicate a problem with adapter ligation It is better to make a new library than to sequence a terrible library!!

QC and sequencing facilities Every facility has their own proven method – trust the experts and have them do quantification even if you have already done it! Every instrument is slightly different Relationship between loading concentration and cluster density is not a simple one! Everything about your library is important for your sequencing facility to know Library construction method, quality of input, size distribution, strain/species, potential low sequence complexity, barcoding method, previous performance (if known), etc.