Tel: +44 (0) 1726 879800 www.partech.co.uk Dissolved Oxygen.

Slides:



Advertisements
Similar presentations
EO TP3 SAMPLING WASTE DISPOSAL SYSTEMS.
Advertisements

Unit Animal Science. Problem Area Aquaculture Lesson Factors Affecting Dissolved Oxygen in Water.
Analyze Immediately Dissolved Oxygen. Topics of Discussion *Definition & Pointers *Applications:Water Quality & Sewage Treatment *Theory *Partial Pressure.
Water Quality Testing Made Easy GPS Aquameter and Multiparameter Aquaprobe The perfect solution for your water quality testing needs.
© ABB Group September 1, 2014 | Slide Turbidity Systems Accurate, reliable turbidity measurement.
Dr C Narain Spantech Products, South Godstone, Surrey, UK The exclusive representative for ACD in Europe, Middle East and India.
Dissolved Oxygen (DO) What is ?. It IS elemental oxygen, O 2, physically absorbed in a liquid. It IS NOT the chemically bound O of H 2 O. It IS NOT physically.
IC Controls 855 & 802 ppm Dissolved Oxygen System pH / ORP Conductivity Dissolved Oxygen Chlorine Standards R1.0 © 2004 IC CONTROLS.
Luminescence Dissolved Oxygen
FUEL CELL.
ENVE 420 Industrial Pollution Control EQUALIZATION Dr. Aslıhan Kerç.
Biological waste water treatment
Introduction to Environmental Engineering Code No. (PE389) Lec. 6.
THE COMPARISON OF WASTEWATER TREATMENT METHODS AND THEIR USE FOR IRRIGATION Presented by: Michael Fynn Date: Tuesday 3rd September 2007.
INTRODUCTION TO THE TREATMENT OF TANNERY EFFLUENTS
The AFC Process What Is AFC? Key Operations are  Balancing of incoming waste streams  Thermophilic activated sludge (AFC) to oxidise the organic.
Oxygen, Temperature, Salinity Craig Kasper FAS 1401L Spring 2012.
Wastewater Processes.
ECE5320 Mechatronics Oxygen Sensor 3/11/2010 Prepared by: Carlos D. Guzman Dept. of Electrical and Computer Engineering Utah State University E:
IC Controls 865 ppb Dissolved Oxygen System pH / ORP Conductivity Dissolved Oxygen Chlorine Standards ppb Galvanic Dissolved Oxygen.
File Name: Dissolved Oxygen.pptFeb 2001 Dissolved Oxygen Overview.
Monroe L. Weber-Shirk S chool of Civil and Environmental Engineering Nutrient Removal Project: Oxygen Requirements ä History of Human Waste ä Nutrient.
Introduction to Environmental Engineering Code No. (PE389) Lec. 5 and 6.
Introduction: We will start with an overview of treatment processes 1) Why do we treat water and wastewater? The main objectives of the conventional wastewater.
Water Quality.
Tel: +44 (0) Turbidity Application and Product Data.
Secondary Treatment Processes
Water Quality.
Increasing Energy Efficiency at the Allegan WWTP MWEA/AWWA Joint Annual Conference August 19, 2010.
Pollutants in wastewater -- Revisited Ammonia Organic matter Nutrients Pathogens Color Metals and SUSPENDED SOLIDS.
Water Pollution. Daily planet run EA2Ej7w8QF;_ylu=X3oDMTFkM25xMDloBHNlYwNzYwRzbGsDa HF2aWQEdnRpZAMEdmlkAzAwMDExNTIzOTM5BGdwb3MDNg.
4.4 WATER POLLUTION.
Wastewater Treatment Processes
SEWAGE TREATMENT.  Sewage is the mainly liquid waste containing some solids produced by humans, typically consisting of washing water, urine, feces,
Waste Water Treatment Plant. HOW DO TREATMENT PLANTS PROTECT OUR WATER? Wastewater treatment plants: Remove solids, everything from rags and plastics.
1 Case Study Managing Aeration Energy Usage (Analyzing BOD load removal per kilowatt hour)
Generally speaking, water is a colorless, transparent, odorless, tasteless liquid that forms the seas, lakes, rivers, and rain and is the basis of the.
Free Residual Chlorine Measurement
Introduction to Environmental Engineering Dr. Kagan ERYURUK
FLOTATION. INTRODUCTION Flotation is an operation that removes not only oil and grease but also suspended solids from wastewaters. Flotation is an operation.
Aqua por la vida BBS SEMARANG GROUP.
Waste Water Treatment. Assignments Draw, label and explain each step in the wastewater treatment process.
AGROFARM WEATHER MONITOR USING LabVIEW. INTRODUCTION Innovation in agriculture field Implementing instrumentation tech. in agricultural field The quantity.
Freshwater pollution. What is water pollution? …the introduction of chemical, physical, or biological agents into water that degrades the quality of the.
Membrane Bioreactors for Wastewater Treatment.
Improve your skills on soil and water research q-SENSE Multi 100 © ETC october 2012.
WATER MANAGEMENT.
Dissolved Oxygen Pollution Types.
Ocean Pollution. What is pollution? Pollution occurs when an environment is contaminated, or dirtied, by waste, chemicals, trash, and other harmful substances.
Tel: +44 (0) Final Effluent Monitoring Application & Product Data.
THE HEALTH OF A WATER SYSTEM There are 6 indicators of the health of a water system: Dissolved oxygen (DO) Temperature Nitrates pHTurbidity Biological.
Waste Water Treatment.
PREVENTING AND REDUCING SURFACE WATER POLLUTION
Lecture (8): liquid wastes treatment (primary, vital, advanced).
Wastewater Treatment.
Self Aspirating Turbine Aerator for all kind of liquid
Wastewater Treatment Dr.Gulve R.M..
Chapter 21 Water Pollution and Treatment
Streaming Current Detectors
Water Treatment.
5.2 Detection and Monitoring of Pollution
11.3 Notes Water Pollution.
Water treatment Potable water…water that is drinkable; safe for consumption Drinking water treatment is widespread in developed countries today However,
5.2 Detection and Monitoring of Pollution
Gas Transfer and Dissolved Oxygen Probe
Wastewater Treatment Secondary Treatment.
________________________________________________________________
Nitrogen Removal University of Kansas
Water Treatment.
Presentation transcript:

Tel: +44 (0) Dissolved Oxygen

Applications Wastewater Treatment Plants – Used in activated sludge tanks for the control of nitrification strength Surface Water Monitoring – Oxygen measurement in rivers, lakes or seas as an indicator of the water quality. Water Treatment – Intake Protection – Reservoir Water Quality Fish Farms – Oxygen measurement and regulation for optimum living and growth conditions Wastewater Treatment Plants – Used in activated sludge tanks for the control of nitrification strength Surface Water Monitoring – Oxygen measurement in rivers, lakes or seas as an indicator of the water quality. Water Treatment – Intake Protection – Reservoir Water Quality Fish Farms – Oxygen measurement and regulation for optimum living and growth conditions

Inlet - Dissolved Oxygen Inlet works Storm Water Activated Sludge - Dissolved Oxygen Tertiary River - Dissolved Oxygen Product Application – Wastewater Treatment

ooooooooooooooooooo ooooooooooooooooooo ooooooooooooooooooo ooooooooooooooooooo ooooooooooooooooooo From Primary Settlement Aeration tank Aeration System Clarifier To Outfall or Tertiary Treatment Sludge Recirculation Excess sludge extraction Activated sludge is a biochemical process for treating sewage and industrial wastewater that uses air (or oxygen) and microorganisms to biologically oxidize organic pollutants, producing a waste sludge (or floc) containing the oxidized material. The oxygen reacts with ammonia to form nitrate (nitrification process). Atmospheric air or pure oxygen is bubbled through primary treated sewage (or industrial wastewater) and combined with organisms to develop a biological floc which reduces the organic content of the sewage The combination of raw sewage and biological mass is commonly known as Mixed Liquor. Activated sludge is a biochemical process for treating sewage and industrial wastewater that uses air (or oxygen) and microorganisms to biologically oxidize organic pollutants, producing a waste sludge (or floc) containing the oxidized material. The oxygen reacts with ammonia to form nitrate (nitrification process). Atmospheric air or pure oxygen is bubbled through primary treated sewage (or industrial wastewater) and combined with organisms to develop a biological floc which reduces the organic content of the sewage The combination of raw sewage and biological mass is commonly known as Mixed Liquor. Simplified Diagram of Activated Sludge System

Air is forced into the aeration basins, it increases the activity of the micro organisms and helps keep the organic waste thoroughly mixed Oxygen is added to the aeration basin to enhance the nitrification process by providing oxygen to combine with ammonia to form nitrates Micro organisms must have at least 0.1 to 0.3mg/l DO. Plants maintain the DO to 2 mg/l. If the DO is less than 2mg/l the bugs in the centre of the floc may die as the bugs on the outside of the floc use up the DO first. If this happens the floc breaks up and settles poorly When the DO comes too high it wastes energy. The aeration process takes between 30-60% of the total electrical power in a WwTW. Automated aeration process using DO according to the ESEPA may reduce energy costs by 50%. Also adds benefit of mixing, bring the bugs, oxygen and nutrient together. This keeps the floc suspended and prevents it from settling Why Measure Dissolved Oxygen?

Platform over aeration process Over aerated process with inaccessible probes Sample point is critical Find Representative sample point of the process Well mixed sample Safe to reach sensors Find Representative sample point of the process Well mixed sample Safe to reach sensors Avoid Dead Zone Extreme Turbulence Area next to Aerator Hazardous access to sensor Reaching over handrails Avoid Dead Zone Extreme Turbulence Area next to Aerator Hazardous access to sensor Reaching over handrails Ensure Success – Pick Your Location

Outlet RASInletAerator Where should the DO sensor go? Oxidation Ditch

Outlet RASInletAerator Here Not representative Not fully mixed False High Good Balance

Technologies

Active Membrane with Luminescent Molécules on an Inerte Material Inert Membrane allows DO molecules to pass into the electrolyte The Sensing Environment for an Optical Cell consist of an optical arrangement where the membrane is excited by an LED to cause a luminescent response. The oxygen reacting with the surface of the membrane causes the luminescent properties to change and hence DO can be monitored. Variations LED Wavelength: Green or Blue Membrane Material Membrane Life The Sensing Environment for an Optical Cell consist of an optical arrangement where the membrane is excited by an LED to cause a luminescent response. The oxygen reacting with the surface of the membrane causes the luminescent properties to change and hence DO can be monitored. Variations LED Wavelength: Green or Blue Membrane Material Membrane Life Sensors Technologies - Comparisons The Sensing Environment for a Galvanic Cell consists of a cathode and anode surrounded by an electrolyte. The oxygen passing through the membrane reacts with the electrolyte generating a potential difference proportional to the concentration of dissolved oxygen. Variations: Clarke Cell – electrolyte is consumed and sensing heads needs replacing. Mackereth Cell – electrolyte is not consumed and no sensor replacement is required. Membrane Materials Electrolyte Composition Anode/Cathode Materials The Sensing Environment for a Galvanic Cell consists of a cathode and anode surrounded by an electrolyte. The oxygen passing through the membrane reacts with the electrolyte generating a potential difference proportional to the concentration of dissolved oxygen. Variations: Clarke Cell – electrolyte is consumed and sensing heads needs replacing. Mackereth Cell – electrolyte is not consumed and no sensor replacement is required. Membrane Materials Electrolyte Composition Anode/Cathode Materials Receiver Emitter

The cell is cylindrical in construction, the anode is so constructed as to give the maximum surface area to improve response.(the type 3 electrode –used for sewage applications has an iron anode) The membrane may be of polyethylene, silicone rubber, PTFE, or any membrane showing good permeability to oxygen. In this cell the oxygen reacts with the metal anode and ceramic cathode generating a current, which is directly proportional to the partial pressure of the oxygen passing through the membrane. It is in effect an electrochemical cell. The electrode has a high temperature coefficient but a thermistor is built into the cell to give temperature compensation over a range from +2 to +40˚C. The signal is amplified and displayed either as concentration or percentage saturation. The cell is cylindrical in construction, the anode is so constructed as to give the maximum surface area to improve response.(the type 3 electrode –used for sewage applications has an iron anode) The membrane may be of polyethylene, silicone rubber, PTFE, or any membrane showing good permeability to oxygen. In this cell the oxygen reacts with the metal anode and ceramic cathode generating a current, which is directly proportional to the partial pressure of the oxygen passing through the membrane. It is in effect an electrochemical cell. The electrode has a high temperature coefficient but a thermistor is built into the cell to give temperature compensation over a range from +2 to +40˚C. The signal is amplified and displayed either as concentration or percentage saturation. Dissolved Oxygen Sensors Technologies – Galvanic Membrane

Compare a good optical sensor and a good galvanic sensor and there is little to choose between them. Optical has a shorter response time (5 times faster than galvanic) and can monitor in static water. Optical Membrane caps can have a short life. –12 – 18 month enforced replacement for some. Good Galvanic sensors will last 3+ years between refurbishments. Compare a good optical sensor and a good galvanic sensor and there is little to choose between them. Optical has a shorter response time (5 times faster than galvanic) and can monitor in static water. Optical Membrane caps can have a short life. –12 – 18 month enforced replacement for some. Good Galvanic sensors will last 3+ years between refurbishments. Does the Sensing Technology Matter? Good Optical and Galvanic sensors work Choose a good sensor, the principal of operation is only part of the decision. Correct installation is key to success. Maintenance is required and must be included in operating budgets New monitors need to be quickly integrated into operator and technicians work programmes, not left until they fail. Or use the supplier/ICA contractor to look after the equipment. Consider who will do the calibration, cleaning and servicing of the instrument. Good Optical and Galvanic sensors work Choose a good sensor, the principal of operation is only part of the decision. Correct installation is key to success. Maintenance is required and must be included in operating budgets New monitors need to be quickly integrated into operator and technicians work programmes, not left until they fail. Or use the supplier/ICA contractor to look after the equipment. Consider who will do the calibration, cleaning and servicing of the instrument.

Product Information

OxyTechw 2 ™ OPT Dissolved Oxygen & Temperature Sensor Optical Luminescent Technology Applications Activated Sludge Control OxyTechw 2 ™ GAL Dissolved Oxygen Galvanic principle. Applications. Activated Sludge Control Exceptional resistance to damage. Long term stability of 3 years without need for sensor replacement or membrane replacement Fast response – Minimal Maintenance Sensors – Dissolved Oxygen

Provides self cleaning action on face of sensor Prone to ragging and fats/grease Floating Ball Places sensor below the surface. Prone to ragging Rigid staff Ragging falls off by moving sensor Places the sensor below the surface Provides self cleaning action on face of sensor Flexible Shaft Sensors Installation & Cleaning

7300w 2 Monitor/Controller Multiple Sensors 1 or 2 into the base unit Upto 8 using expansion boxes Any w² sensor is compatible with the monitor Graphic Display with trending Easy to configure Multiple language ability Flexible control and monitoring options Profibus output – anticipated late 2011 Triple Validation option Dosing control and datalogging available on request

Example of a Dissolved Oxygen Application

Example of connection layout for 7300w 2 (1 or 2 sensors) Example of connection layout for 7300w 2 (1 or 2 sensors)

Example of connection layout for 7300w 2 (1 to 8 sensors) Example of connection layout for 7300w 2 (1 to 8 sensors)

Portable Option Galvanic Sensor Self Polarising and Self Temperature Compensated No warm up time, short response time 90% of end value in less than 20 seconds Automatic Calibration and self check 1400 hours from one 9V alkaline battery Approximately 2 years with 1 hour use per day Large easy to read graphical LCD display Galvanic Sensor Self Polarising and Self Temperature Compensated No warm up time, short response time 90% of end value in less than 20 seconds Automatic Calibration and self check 1400 hours from one 9V alkaline battery Approximately 2 years with 1 hour use per day Large easy to read graphical LCD display

Tel: +44 (0) Andrew Wallace - Field Sales Engineer Mobile: Angus Fosten - Sales and Marketing Director Mobile: Clive Teobald - Sales Engineer Mobile: Derek Bourne - Export Sales and Marketing Director Mobile: Jan Johnson - Sales Administrator