INTRACRANIAL PRESSURE MONITOR Dan Frost Rebecca Koszalinski Justin Lundell Michael Socie Advisor: Professor Naomi Chesler, UW-Madison Client: Joshua Medow,

Slides:



Advertisements
Similar presentations
Hydrocephalus. Background What is hydrocephalus? Abnormal accumulation of cerebrospinal fluid in the ventricles of the brain Results in elevated intracranial.
Advertisements

MR Airway Pressure Device Group Members Laura Sheehan Kevin Johnson Jon Cappel Noelle Simatic Client Dr. Victor Haughton Advisor Prof. Mitch Tyler.
1st practice Medical Informatics Biomedical Signal Processing TAMUS, Zoltán Ádám
Tools for Non-Invasively Measuring Brain Compliance By Mark L. Manwaring.
Presented by- Md. Bashir Uddin Roll: Dept. of BME KUET, Khulna-9203.
Infrascanner Harry Martin.
MRI Infusion Pump. Advisor Dr. Naomi Chesler  Biomedical Engineering  University of Wisconsin - Madison.
Sensors and Their Uses in Hospitals
Mist Generator Kelly Toy Jon Cappel Joe Bothwell Abdikarim Mahamud Advisor – John Webster Client – Jack Jiang, MD, PhD tents/06.00/ asp.
Peak Inspiratory and Expiratory Flow Meter Team: Andrew Eley, Sarah Offutt, Darshan Patel, Eric Bader BME 200/300 December 2, 2005.
GROUP 2: Martha Ingram, Megan Johnston, Chelsea Samson MENTORS: Dr. Michael Holzman, Dr. William Beck, Dr. Benjamin Poulose AN OPENING IN THE ABDOMEN,
Group 4 Derek Sheesley Sunil Shah Michael Iskhakov Marina Louis Anthony Jones.
Intracranial Pressure Monitoring Calibration and Setup Ashish V M.
Team Members: Joe Bothwell BWIG IT Ryan Fischer Communicator Brant Kochsiek Team Leader Brian Schwartz BWIG David Ugai BSAC Dan Carlson BSAC.
Elastic Measurements in an Operating Shoe Sole
Esophageal Strictures William Stanford – Leader & BSAC Daniel Frost – BWIG Thomas Fleming – Communicator Client: Dr. Mark Reichelderfer, MD Advisor: Professor.
Understanding Blood Pressure. Your heart sends blood to the whole body Oxygen Nutrients Carries away waste Heart Parts: Arteries Capillaries Veins.
Skin Color Monitor Sarah Offutt, Rachel Mosher, Victoria Vasys BME 301 March 7, 2008.
Smart transmitters.
Team Members: Joe Bothwell Communicator Kelly ToyTeam Leader Jon Cappel BWIG Karim Mahamud BSAC.
Quality Control Spirometry & Lung Volumes
IV Tubing Organizer Blake Hondl, Amit Mehta, Ryan Pope, Kristen Sipsma, April Zehm, Katie Zenker BME 200/300 October 10, 2003.
April 13, 2004 Design of a Prenatal Perfusion System PROJECT PROPOSAL Timothy Bachman Garrett Grindle Leigh McClure Scott Morley Bioengineering 1160/61.
Multifunction IV Catheter Brett Byram 1, Steve Harris 1, Adam Travis 1 Advisors: Gary Byram, Ph.D. 2 ; Paul King, Ph.D., P.E. 1 1 Department of Biomedical.
Authors Timothy Eng Team Leader Mary Lim BWIG Lauren Hensley BSAC April Zehm Communicator.
Development of Depth Gage Instrument Brian Cost Justin Johnson Tyler Kibbee February 19, 2008.
Pulmonary Flow Resistive Device Taya Furmanski Albert Attia Advisor: Thomas Doyle, M.D. April 9, 2003.
Accessible Home Vital Signs Monitoring System Kristyn Eilertsen Adam Goodale Stephen Kepper Sunil Narayan Stacey Tarver Group 22 BME 272.
Solar Powered Blood Pressure Assist Device Laura Allen 1, James Berry 2, Casey Duckwall 2, David Harris 1 Advisor: Dr. Franz Baudenbacher 2 Department.
Team: Charlie Haggart, Gabriel J. Martínez-Díaz,
Heart Failure Devices: Staying Connected Lisa D. Rathman, MSN, CRNP, CCRN, CHFN The Heart Group of Lancaster General Health Lancaster, PA.
Measuring Monkey Eye Movement in the MRI Team Members: Josh Anders Betsy Appel Bryan Baxter Alyssa Walsworth Client: Luis Populin,Ph. D. Advisor: Justin.
Measurable Milestones END-PRODUCT DESCRIPTION The bed monitor system helps prevent injury by predicting when an individual is attempting to leave the bed.
EMG Biofeedback Device BME 200/300 Fall 2003 Department of Biomedical Engineering University of Wisconsin-Madison.
MR Airway Pressure Device Group Members Laura Sheehan Kevin Johnson Jon Cappel Noelle Simatic Client Dr. Victor Haughton Advisor Prof. Mitch Tyler.
Pulmonary Flow Resistive Device Taya Furmanski Albert Attia Advisor: Thomas Doyle, M.D. March 17, 2003.
Pulmonary Flow Resistive Device Taya Furmanski Albert Attia Advisor: Thomas Doyle, M.D. February 12, 2003.
BME Design 200/300 Glaucoma Medication Reminder. Intellectual Property  All information provided by individuals or Design Project Groups during this.
Balances The balance is an instrument which measures the mass of a body or substance using the gravity force which acts on that body At present, there.
Tested liquid flow rate: Aspirator was run for 30 second intervals Liquid Recorded collected volume Flow rate was calculated as liters/minute Air Connected.
By: Mason Jellings, Sarah Reichert, John Byce, and Justin Gearing Advisor: Prof. Tom Yen Client: Dr. Joshua Medow Instrument Controlled Microscopy for.
Gas Pressure Meter (Engineering World Health) Advisor: Prof. Ken Gentry Client: Prof. John Webster, Engineering World Health Engineering World Health Team.
Team Members: Allison McArton Angwei Law Jonathan Meyer Grant Smith Padraic Casserly Advisor: Dr. John G. Webster, Ph.D. Client: Engineering World Health.
Transnasal Endoscopic Model Justin Lundell, Mike Socie, Alice Tang, Karissa Thoma Advisor: Willis Tompkins Client: Brian Petty, M.A.
INSTRUMENT CONTROLLED MICROSCOPY Mason Jellings, Justin Gearing, Sarah Reichert, John Byce Client: Dr. Joshua Medow Advisor: Professor Thomas Yen Introduction.
Gas Pressure Meter (Engineering World Health) Advisor: Professor Naomi Chesler Client: EWH and Professor John Webster Team Members: Ksenija Bujanovic-
Determine method of rapid prototyping or plastic extrusion to create prototype of true-to-scale catheter Determine optimal slot size without affecting.
Gas Pressure Meter Advisor: Naomi Chesler Client: EWH Team Members Ksenija Bujanovic – Team Leader Claire Edlebeck – Communicator Mike Oldenburg – BWIG.
INTRACRANIAL PRESSURE MONITOR INTRACRANIAL PRESSURE MONITOR Lacey Halfen, Jessica Hause, Erin Main, and Peter Strohm Client: Dr. Josh Medow Advisor: Willis.
ICP Monitor Client Josh Medow Advisor Willis Tompkins Team Members Lacey Halfen - BSAC Jess Hause – Leader Erin Main – Communicator Peter Strohm - BWIG.
Terminology modeling and measurements
Endotracheal Tube Cuff
Intracranial Pressure Sensor
Testing System for Pressure Sensitive Cardiovascular Catheter
Intracranial Pressure Monitor
Endotracheal Tube Pressure Monitor
GPS-Enabled Inhaler Final Design Cost of Materials Abstract
Padraic Casserly, Andrew Dias, Joey Labuz, Joel Webb
Device Specifications Sleep Disordered Breathing
Device for Measuring Esophageal Tissue Compliance
Peak Inspiratory and Expiratory Flow Meter
Breast Pedicle Protector
MRI Lower Leg Exerciser
INSTRUMENTASI INDUSTRI
Transcranial Magnetic Stimulation Positioner
Breast Pedicle Protector
Robotic Needle End Arm Effector for Integration With CT Scan
Endotracheal Tube Cuff Valve
Instrumented Hand Exerciser
CHAMPION Trial design: Patients with recent hospitalization for heart failure were implanted with a pulmonary artery pressure monitor and randomized so.
Presentation transcript:

INTRACRANIAL PRESSURE MONITOR Dan Frost Rebecca Koszalinski Justin Lundell Michael Socie Advisor: Professor Naomi Chesler, UW-Madison Client: Joshua Medow, M.D., UW-Hospital

Background Why is this technology needed? –Shunt failure 17% –Hydrocephalus – ventricle blocked –Symptoms not specific for diagnosis –Children don’t report symptoms –Excess CT scan testing dangerous

Current Technology Existing technology –CT scan –Ultrasound –Exploratory surgery –Shunt taps What this technology lacks –Patient home testing –Multiple use monitoring –Absence of radiation –Accessibility to patient –Ease of testing for children –Cost effective testing

Current Devices Radionics Telesensor for intracranial pressure Medtronic Hemodynamic Monitor for symptomatic heart failure Duncan Graham-Rowe batteryless implant for blood pressure

Problem Statement ICP monitor should: –Measure pressure of intracranial fluid –Produce accurate recordings –Have a low drift rate –Be small, convenient to patient –Be MRI compatible

Design Constraints Small, implantable, durable Bio and MRI compatible Low power High precision (1 mmHg error) Low drift rate (<1% annually) Send output for reading

Materials & Budget Polypropylene sheets Aluminum rods MicroEpsilon EddyNCDT 2mm range pressure sensor $1.60 * 5 = $8.00 $3.00 * 4 = $12.00 $1500 analog only $3600 with digital display Purchase pending

Construction Thermoforming –Cheap –Simple process –Low repeatability –Prototype applicable Injection molding –$10,000+ for a mold –Lab equipment needed –Highly repeatable –Good for mass production

Final Prototype Aluminum Rod Membrane Polypropylene Cap 22 mm 18mm 4.76 mm 3 mm 20 mm 8 mm

Testing Liquid above zero line corresponds to positive pressure on prototype Sensor Tip Prototype P = 0 1mL = 0.6 mmHg mmHg Normal mmHg Fatal if prolonged 40+ mmHg Coma and death

Results 10mL = 6mmHg

Future Work Further testing for: –Pressure range –Accuracy –Durability If testing is successful: –Purchase sensor –Patents and FDA approval –Mass production via injection molding

References & Acknowledgements References: 1.“Measuring Strain Gauges” National Instruments “Wheatstone Bridge Background” dwiarda Dr. Josh Medow, Neurosurgery, UW Hospital 4.Collins, C.C. (1970) Biomedical transensors: A review. J. Biomed. Syst., 1: Webster, John. (1978) Medical Instrumentation: Application and Design 1st Edition 6.Budgett D., et al. (2007) Novel technology for the provision of power to implantable physiological devices. J Appl Physiol 102: Konigsberg, E., and R. H. Russel., (1968) A bettery operated miniature pressure transducer amplifier system. Biomedical Sciences Instrumentation, New York: Plenum, Vol. IV. Acknowledgements: Naomi Chesler, Josh Medow, John Webster, Tim Fauser, Adam Kramschuster