Anatomic Feasibility of Distal Fibula Bicortical Fixation with Lateral Neutralization Plating Laura E. Sansosti, DPM a, and Andrew J. Meyr, DPM FACFAS.

Slides:



Advertisements
Similar presentations
دانشیار گروه ارتوپدی دانشگاه علوم پزشکی مشهد
Advertisements

Ankle problems/procedures and techniques
BASICS OF ORTHOPEDIC RADIOLOGY
Mr G Shyamalan Consultant Hand Surgeon HEFT.  Understanding the radiograph  Classification  Imaging and consent  Approach  Surgical case based discussion.
Olecranon fracture Lonnie Froberg, MD, Ph.D Odense University Hospital.
Malunions: Principles of Evaluation & Treatment Clifford B Jones, MD Orthopaedic Associates of Michigan Clinical Professor, MSU/CHM Grand Rapids, MI May.
Coen A. Wijdicks, Ph.D. Chief Operating Officer Director of the Department of BioMedical Engineering Senior Staff Scientist Steadman.
Open Reduction and Internal Fixation of Intra-Articular Calcaneal Fractures Via an Extensile Lateral Approach by Karl M. Schweitzer, Trevor R. Gaskill,
by Saam Morshed, Kevin Choo, Utku Kandemir, and Scott Patrick Kaiser
Anatomic Description of the Oblique Bands of the Annular Ligament in the Human Elbow Vijit Chouhan 1, Akin Cil 1,2, James Barnes 1,2 1 UMKC School of Medicine,
The Effect of Suture-Button Fixation on Simulated Syndesmotic Malreduction: A Cadaveric Study by Robert W. Westermann, Chamnanni Rungprai, Jessica E. Goetz,
Biomechanics of Plate Fixation
Internal Fixation of Ankle Fractures
Where Art Thou Diabetic Limb Salvage Data?: A Literature Review and Subsequent Challenge to the Diabetic Limb Salvage Community Christine K. Nolan, DPM.
A Pictorial Review of Reconstructive Foot and Ankle Surgery: Evaluation and Intervention of the Flatfoot Deformity Andrew J. Meyr, DPM FACFAS a, Laura.
A reliable anatomical marker for the Evans Calcaneal Osteotomy Corine L. Creech, DPM¹; Kerianne Spiess, DPM¹, Kieran T. Mahan, DPM FACFAS 2 ¹Resident,
Distal Femur Fractures
Locking Plates Advantages & Indications
X-ray Interpretation Skills Dr. Hisham Alsanawi Orthopaedic Consultant and Assistant Professor.
ACTIVMOTION.
Biocompatibility of Titanium Implants in Beagle Dogs Chuck Rosenwasser Mentors: Frank Raia & Mel Rosenwasser Columbia Presbyterian Medical Center.
Retrospective Review of ACL Reconstruction in Children 12 Years of Age or Younger Dr. Answorth Allen, MD Dr. Steven Thorton, MD Hospital for Special Surgery.
Computer-Assisted Navigation in Total Knee Replacement: Results of an Initial Experience in Thirty-five Patients by S. David Stulberg, Peter Loan, and.
The Effect of Patient Positioning on Absolute Digital Toe Pressures with Non-Invasive Vascular Testing Laura Sansosti, DPM a, Michael D. Berger b, Michael.
Session VIII Fixation Devices Casts are stress sharing Pins, screws, Steinman pins and Kirschner wires when used alone provide partial immobilization and.
Reverse Total Shoulder Arthroplasty Reza Omid, M.D. Assistant Professor Orthopaedic Surgery Shoulder & Elbow Reconstruction Sports Medicine Keck School.
Extraperiosteal Plating of Pronation-Abduction Ankle Fractures by Jodi Siegel, and Paul Tornetta JBJS Essent Surg Tech Volume os-90(Supplement 2 Part 1):
Internal Fixation of Type-C Distal Femoral Fractures in Osteoporotic Bone by Dirk Wähnert, Konrad L. Hoffmeier, Geert von Oldenburg, Rosemarie Fröber,
Results of Polyaxial Locked-Plate Fixation of Periarticular Fractures of the Knee by George Haidukewych, Stephen A. Sems, David Huebner, Daniel Horwitz,
The Biceps Tendon: From Proximal to Distal by David Y. Ding, Garret Garofolo, Dylan Lowe, Eric J. Strauss, and Laith M. Jazrawi J Bone Joint Surg Am Volume.
by Matjaz Veselko, and Matej Kastelec
ALTERNATIVE TREATMENT IN PATIENTS WITH
MANAGEMENT OF CONGENITAL PSEUDARTHROSIS OF TIBIA
Supramalleolar Osteotomy in Patients with Varus Ankle Osteoarthritis by Woo-Chun Lee, Jeong-Seok Moon, Kang Lee, Woo Jin Byun, and Sang Hyeong Lee JBJS.
The Effect of Patient Positioning on Radiographic Assessment of Fibular Length. Corine L. Creech, DPM a, Laura E. Sansosti, DPM a, and Andrew J. Meyr,
Over-Tightening of the Syndesmosis After Ankle Fracture by Dirk S. Gesink, and John G. Anderson JBJS Case Connect Volume 5(4):e85 October 14, 2015 ©2015.
Correction of Tibial Deformity with Use of the Ilizarov- Taylor Spatial Frame by S. Robert Rozbruch, Austin T. Fragomen, and Svetlana Ilizarov J Bone Joint.
Locking Plates: Tips and Tricks by Wade R. Smith, Bruce H. Ziran, Jeff O. Anglen, and Philip F. Stahel J Bone Joint Surg Am Volume 89(10): October.
Module 12 RESTORE RESTORE ® External Hex Implant System Surgical Hands-On.
Abstract  An abstract is a concise summary of a larger project (a thesis, research report, performance, service project, etc.) that concisely describes.
Treatment of Closed Tibial Fractures by Andrew H Schmidt, Christopher G. Finkemeier, and Paul Tornetta J Bone Joint Surg Am Volume 85(2): February.
PRESENTERSSUPERVISOR Mickey Macatha, Sharon Ocholla.Dr. James Obondi Maseno University school of medicineChief orthopedic surgeon MBChB VDr. Steve Okello.
Competence of the Deltoid Ligament in Bimalleolar Ankle Fractures After Medial Malleolar Fixation* by Paul Tornetta J Bone Joint Surg Am Volume 82(6):
Quantitative assessment of triplanar first metatarsophalangeal joint radiographic parameters Todd Hasenstein, DPM a, and Andrew J. Meyr, DPM FACFAS b a.
Statement of Purpose and Literature Review
Mohammed El-Gebiely, MD
1st Zliten Orthopedic Symposium (ZOS) 10th March,2016
Late results after a two-stage protocol for soft tissue management in the treatment of tibial pilon fractures Obadă B., Șerban Al. O., Costea D., Grasa.
Mid to long term functional outcomes of reduced and malreduced ankle fractures in two university teaching hospitals V Roberts1, L Mason2, E Harrison2,
Large Fragment Workshop
Distal Femoral Osteotomy: Lateral Opening Wedge Technique
A Novel Closed-Wedge High Tibial Osteotomy Procedure to Treat Osteoarthritis of the Knee: Hybrid Technique and Rehabilitation Measures  Ryohei Takeuchi,
Eiji Kondo, M. D. , Ph. D. , Kazunori Yasuda, M. D. , Ph. D
Treatment of Midshaft Clavicle Fractures: Application of Local Autograft With Concurrent Plate Fixation  Erik L. Slette, B.A., Jacob D. Mikula, B.S.,
Alessio Bernasconi, M. D. , Nazim Mehdi, M. D. , François Lintz, M. D
Treatment of Midshaft Clavicle Fractures: Application of Local Autograft With Concurrent Plate Fixation  Erik L. Slette, B.A., Jacob D. Mikula, B.S.,
Mosaicplasty Using Grafts From the Upper Tibiofibular Joint
Masato Takao, M. D. , Ph. D. , Mark Glazebrook, M. D. , M. Sc. , Ph. D
Anatomical Arthroscopic Anterior Talofibular Ligament and Calcaneofibular Ligament Reconstruction Using an Autogenic Hamstring Tendon: Safe Creation of.
Distal Lateral Fibular Workshop Kit
Alessio Bernasconi, M. D. , Nazim Mehdi, M. D. , François Lintz, M. D
Case for small group discussion
Fractures of the humeral diaphysis
Fractures of the olecranon and the patella
Case for small group discussion
Fractures of the tibial diaphysis
Case for small group discussion
Case for small group discussion
Presentation transcript:

Anatomic Feasibility of Distal Fibula Bicortical Fixation with Lateral Neutralization Plating Laura E. Sansosti, DPM a, and Andrew J. Meyr, DPM FACFAS b a Resident, Temple University Hospital Podiatric Surgical Residency Program, Philadelphia, Pennsylvania b Associate Professor and Residency Program Director, Department of Podiatric Surgery, Temple University School of Podiatric Medicine and Temple University Hospital, Philadelphia, Pennsylvania *Please don’t hesitate to contact AJM with any questions. He’s happy to provide you with a.pdf of this poster if you him. [] AO Principles of Fracture Management. [] Milner BF, Mercer D, Firoozbakhsh K, Larsen K, Decoster TA, Miller RA. Bicortical screw fixation of distal fibula fractures with a lateral plate: an anatomic and biomechanical study of a new technique. J Foot Ankle Surg Sep-Oct; 46(5): DiscussionResults References Methodology Statement of Purpose and Literature Review Supination-external rotation type ankle fractures are the most commonly encountered fracture pattern encountered by the foot and ankle surgeon. When utilizing the interfragmentary compression and neutralization plating technique in this location, typically only two screw holes are available distal to the fracture fragment, and further, screws in this location are typically inserted in a unicortical manner to avoid penetration of the articular cartilage of the ankle mortise. It has been our clinical experience that surgeons are often less than satisfied with this unicortical distal fixation, especially in situations of weakened cancellous bone stock. Additionally, standard AO technique dictates that 3-4 cortices are purchased distal to the fracture fragment for a more stable plate fixation construct. In 2007, Milner et al observed a more biomechanically stable construct when comparing bicortical screws to unicortical screws in the distal fibula. They further described an anatomic “safe corridor” based on 8 cadaveric limbs when the distal most screw was inserted 10° posterior to midline and the second most distal screw was angled 25° superior and 12° posterior. The objective of this investigation was to examine the anatomic feasibility of distal fibula bicortical fixation with lateral neutralization plating. As with any scientific investigation, critical readers are encouraged to review the study design and results and reach their own conclusions, while the following represents our conclusions based on the specific results. As scientists, we also never consider data to be definitive, but do think that these results are worthy of attention and future investigation. -We think that the results of this investigation demonstrate clinically significant findings. Extra-articular bicortical distal fibula fixation was able to be performed in the most distal screw hole in majority of cases (79.31%), and in the second most distal screw hole in all cases (100.0%) when angulated as described. In most cases the most distal screw terminated within the posterior fibular fossa when angled 10° posterior to the midline of the fibula. -Descriptive statistics of the length measurement of these screws might also provide foot and ankle surgeons with some degree of confidence during measurement and insertion. In the distal fibula, we found all bicortical screws to be at least 16mm in length and none longer than 24mm, with most screws measuring approximately 20mm. The results of this investigation expand and to some degree confirm the findings of the Milner et al investigation with a larger sample size, however, it is still our intention to continue data collection on more limbs to increase the size of our anatomic cohort. In conclusion, the results of this investigation provides evidence that bicortical distal fibula fixation in concordance with AO principles is possible with a simple 1/3 tubular plate. The increase in stability of this construct could negate the need for more expensive fixation options (i.e. locked plates and anatomic contoured plates) as well as fixation options that are biomechanically stable but potentially anatomically impeding (i.e. posterior anti-glide plating). Bicortical screw distal fibula fixation was successful in all 29 limbs: -The length of the most distal screw measured a mean ± standard deviation (range; 95% confidence interval) of ± 2.49mm (14-26mm; mm). The screw was found to be intra-articular within the distal fibula in 4 (4.94%) of 81 cases, and close to articular in 9 (11.11%) of 29 cases. Therefore, in 68 (83.95%) of 81 cases, the terminus of the distal screw was well extra-articular within the posterior malleolar fossa. -The length of the more proximal screw measured a mean ± standard deviation (range; 95% confidence interval) of ± 3.02mm (12-28mm; mm). The screw was found to be intra-articular within the distal fibula in 0 (0.0%) of 81 cases, and close to articular in 0 (0.0%) of 81 cases. Figure 1: We positioned 1/3 tubular plates on the lateral distal fibula as would be expected during fixation of a supination-external rotation type fibular fracture. Conventionally in these situations, two holes in the plate are available distal to the fracture allowing for screw purchase of two total cortices if performed in a unicortical manner. However, AO technique recommends purchase of 3-4 total cortices distal to the fracture with neutralization plating. Figure 2: We then drilled bicortically and inserted 3.5mm fully threaded cortical screws through the two most distal holes in the plate. The most distal hole was drilled aiming perpendicular to the long axis of the fibula and 10° posterior to midline. The second most distal hole was drilled aiming 25° superiorly and 12° posterior to midline. Axis guides built for these positions were utilized for consistent drill positioning. Figure 3: The screw tracts were measured with a depth gauge according to standard technique followed by insertion of screws of appropriate length. Descriptive statistics were performed of these measurements. Figure 4: Dissection was then performed removing the fibula from the ankle mortise with an assessment of whether the screws invaded the articular cartilage of the distal fibula. We observed that the terminus of the distal screw was well extra-articular in 23 (79.31%) of 29 limbs. The distal most screw typically ended in the posterior malleolar fossa while the second most distal screw always (100.0%) ended superior to the ankle joint. Figure 5: This cadaveric specimen displays an example where the distal most screw invaded the articular cartilage of the distal fibula. This occurred in 2 (6.67%) of 29 cases with an additional 4 cases (13.33%) being a little “too close for comfort,” at least in the opinion of the corresponding author. Figure 6: The results of this investigation have given us the confidence to begin attempting this technique in vivo. We have been careful to ensure extra-articular positioning with intra-operative fluoroscopy, but have to this point been satisfied with the stabilization construct. We performed 1/3 tubular neutralization plating on 81 embalmed cadaveric specimens (39 right-sided) according to our standard operative technique for the fixation of supination-external rotation type ankle fractures. The plate was first positioned on the lateral aspect of the distal fibula at the seemingly optimal anatomic contouring (Figure 1). The plate was contoured if needed. A 2.5mm drill bit was then used to drill bicortically through the two most distal holes on the plate. The most distal hole was drilled perpendicular to the long axis of the fibula and angled 10° posteriorly. The second most distal hole was drilled 25° superior angled 12° posteriorly to the long axis of the fibula. We fashioned two metallic axis guides at these two different angular specifications to ensure the appropriate drill angle for the two locations (Figure 2). The depth gauge was then utilized to ascertain appropriate length, and a 3.5mm fully threaded cortical screw subsequently inserted (Figure 3). Dissection was then performed removing the distal fibular from the ankle mortise to assess the terminus of the two screws (Figure 4). A subjective determination was then performed by the corresponding author (AJM) as to whether or not the screw was “intra-articular”, “extra- articular”, or “extra-articular but a little too close for comfort”. Descriptive statistics were additionally performed on the observed appropriate screw lengths.