Inventory of the ECAL spare Inner modules Scanning with 137 Cs 1Yu. Guz 2013/12/04 There are 32 spare ECAL Inner modules stored in b. 156. The purpose.

Slides:



Advertisements
Similar presentations
LHCb HCAL PMT problems HAMAMATSU studies 1 Yu. Guz.
Advertisements

1Beam Line Review. 17th November Detector parameters Fermilab Beam line monitors built to replaced SWICS Scintillating fibre tracker – readout.
Status of the Clermont-Ferrand R&D works Tilecal upgrade meeting at CERN (11 February 2015) François Vazeille on behalf of Clermont-Fd team ● Active Dividers:
ECAL and HCAL status 1Yu. Guz 2014/11/26. TED shots, 24-Nov 2Yu. Guz 2014/11/26.
Chapter 10 Section 2 Hypothesis Tests for a Population Mean
Tests of scintillators CsI, CsI(Na), BGO, NaI(Tl) CsI(Tl)
Preliminary Scan in x Shahab Khan. Scan in x procedure Placed Sr 90 radiation source 6mm from the edge of the left most cell moved across along the center.
Chapter 10 Optical fiber measuring instruments and testing single-mode fiber networks.
No dead cells (yet) The integrated luminosity since the last meeting: 477 pb -1 ; since the last TS: 609 pb -1 ; smooth operation since the last meeting,
Yu. Guz 2015/04/211 CALO HV Updated version of the 2012 slides, ** See also Anatoli’s.
Studies of radiation hardness of ECAL modules 1Yu. Guz 2013/05/28.
Yu. Guz 18/12/20061 HCAL commissioning: status and plans Yu. Guz, IHEP, Protvino Outline 1. current status of HCAL a)CW+PM b)signal cables c)LED monitoring.
The High Voltage, Monitoring and Control systems of the Hadronic and Electromagnetic calorimeters are essentially slow control based, and therefore are.
Study of response uniformity of LHCb ECAL Mikhail Prokudin, ITEP.
Anatoli Konoplyannikov Design and integration of HV, LED monitoring and calibration system for HCAL Overview of the subsystems design High voltage.
AHCAL Electronics. Status Commissioning and Integration Peter Göttlicher for the AHCAL developers CALICE meeting UT Arlington, March 12th, 2010.
Ondřej Svoboda for the ECAL group HADES collaboration meeting XXV, 19 – 23 November 2012 GSI.
0 The LHCb Hadron Calorimeter Rustem Dzhelyadin, (IHEP, Protvino) INSTR02 Conference, BNPI, Novosibirsk, Russia Contents: Œ Design overview  Trigger with.
1 Status of the calorimeter PMT’s time alignment LHCb CALO meeting Anatoli Konoplyannikov /ITEP/ Introduction Development status of the PMT time.
ECAL LED monitoring system upgrade R&D status V. Egorychev, P. Shatalov, A. Zhokhov (ITEP, Moscow, Russia) E. Chernov, Yu. Guz, V. Obraztsov (IHEP Protvino,
HCAL status and plans Yu. Guz.  Finally, no dead cells in the run However: There are unstable PMTs (mainly rate effect) Dark current.
Scanning the irradiated ECAL modules with 137 Cs source Yu. Guz 2011/12/161.
Scintillator tile-SiPM system development for CALICE Engineering AHCAL Prototype Michael Danilov, ITEP & CALICE LCWS10 Beijing March 2010 Outline New scintillator.
1 xCAL monitoring Yu. Guz, IHEP, Protvino I.Machikhiliyan, ITEP, Moscow.
ECAL LED monitoring system upgrade Pavel Shatalov ITEP, Moscow, Russia Yuri Guz IHEP Protvino, Russia.
Status of the Remote HV System 10 June 2015 TileCal week, upgrade session Roméo Bonnefoy, Romain Madar and François Vazeille ● Summary of performances.
16/04/20031PNPI / LHCb Muon EDR Wire Pad Chambers PNPI design for regions R4 in Stations M2,M3,M4  4 gas gaps of 5mm±70µm;  Active area: 1224x252.8 mm².
ECAL and HCAL status 1Yu. Guz 2015/02/18. ECAL maintenance 2Yu. Guz 2015/02/18 There were 22 non operational cells at the A side, because of 3 dead CW.
1 HCAL production, QC and preparation for installation Overview of the status report Rustem DZHELYADIN (IHEP, Protvino)  The general status.
1 Yu. Guz HCAL status 22/06/ Yu. Guz HCAL 137 Cs calibration The 3 rd run in 2011 was performed at the technical stop, May-09. Two source passages,
LHCb HCAL PMT problems initial report 1 Yu. Guz. LHCb HCAL & ECAL 2 Yu. Guz PMTs of type HAMAMATSU R are used in both HCAL and ECAL. The detector.
7/28/2003DC/EC Review Aerogel Read out Electronics K. Ozawa, N. Kurihara, M. Inaba, H. Masui T. Sakaguchi, T. Matsumoto.
Calo preparation for 2015 Goals: -Trigger stability -Good calibration for HLT2 processing -Improved calibration ( timing, e/gamma response) for all calo.
1 LHCb CALO commissioning meeting Anatoli Konoplyannikov /ITEP/ XCAL commissioning with LED News New LED scan and stability data for ECAL were.
DESY Beam Test of a EM Calorimeter Prototype with Extruded Scintillator Strips DongHee Kim Kyungpook National University Daegu, South Korea.
1 Calorimeters LED control LHCb CALO meeting Anatoli Konoplyannikov /ITEP/ Status of the calorimeters LV power supply and ECS control Status of.
CALO DCS upgrade A. Konoplyannikov, M. Soldatov, A. Ostankov, Yu. Guz (IHEP, Protvino) V. Kudryavtsev (BINP, Novosibirsk)
1 LHCb CALO commissioning meeting Anatoli Konoplyannikov /ITEP/ XCAL commissioning with LED Outline Scan data collected on HCAL and ECAL during.
ECAL and HCAL technical status 1Yu. Guz 2015/09/02.
Yu. Guz 21/04/20061 Database usage by calorimeters Yu. Guz IHEP Protvino.
DESY Beam Test of a EM Calorimeter Prototype with Extruded Strip Scintillator DongHee Kim Kyungpook National University Daegu, South Korea.
Upgrade of the LHCb ECAL monitoring system Yu. Guz (IHEP Protvino / CERN), on behalf of the LHCb collaboration 07/04/2014.
Calorimeter Status: Preparing RUN II Pascal Perret LPC Clermont 25 February 2014.
BRANs Sune Jakobsen (BE-BI-PM) LHC BI 2015 summary
1 ECS CALO HV Control CALO Piquet Training Session Anatoli Konoplyannikov /ITEP/ Outline  ECS HV control of the ECAL/HCAL sub-detectors.  Introduction.
Yu. Guz 08/02/20121 HCAL 2011/2012 shutdown activities.
1 ECAL/PRS quality check with LED system Outline  Introduction, how to use LED time scan data for a detector quality check;  Last collected data of the.
PMT test device setup functionality –reproducibility of output signal –dynamic range –limitations –test duration conclusion T. Wälchli, TT-Meeting Brussels,
HCAL1 Status 2004 Oleg Gavrishchuk, JINR, Dubna 1. HCAL1 performance in 2004 General design High Voltage system LED monitoring 2. Stability in 2003 Led.
CALO News Pascal Perret LPC Clermont 23 October 2011.
Yu. Guz 14/03/20121 CALO HV ** See also Anatoli’s slides for the 2009 piquet training **
Outline Upgrade status of the ECAL/HCAL HV control mezzanine board;  Firmware design,  Setup for making functional tests and validation FPGA firmware.
1 XCAL LED quality check and time alignment consideration CALO meeting Anatoli Konoplyannikov [ITEP / LAPP] Outline  CALO sub-detector status.
Authors: Dmitrii Pereima, ITEP; Dmitry Golubkov, ITEP; Iouri Gouz, IHEP; Victor Egorychev, ITEP. Visualization of HCAL 137 Cs calibration data 1 CALO +
M.Taguchi and T.Nobuhara(Kyoto) HPK MPPC(Multi Pixel Photon Counter) status T2K280m meeting.
SHIP calorimeters at test beam I. KorolkoFebruary 2016.
ECAL LED monitoring system upgrade status 04/09/20131.
TileCal EM scale status Irene Vichou University of Illinois at Urbana on behalf of TileCal Collaboration MPI Hadronic Calibration Workshop May 3 rd, 2006.
The LHCb Calorimeter system
Two-Sample Hypothesis Testing
PMT/CW Irradiation tests-2010
Chapter 9: Testing a Claim
JMU Quantum Efficiency tests
Instrumentation for Colliding Beam Physics 2017
LHCb HCAL: performance and calibration
Chapter 9: Testing a Claim
Chapter 9: Testing a Claim
Chapter 9: Testing a Claim
Unit 5: Hypothesis Testing
Significance Tests: The Basics
Presentation transcript:

Inventory of the ECAL spare Inner modules Scanning with 137 Cs 1Yu. Guz 2013/12/04 There are 32 spare ECAL Inner modules stored in b The purpose of the inventory was to determine whether they are operational and good for replacement of the ECAL central modules after the LHCb upgrade. The chosen method was to scan the modules with the 137 Cs source and measure DC anode current of PMTs. When using the same PMTs at same HV for all the modules, we measure the relative light yield of the cells. The bad cells are expected to have the (relative) light yield significantly lower than good ones. Also, significant deviation of the shape of I PMT (x) from the standard one can be a signature of a bad cell. The scan was performed in b Nov The spare HCAL 137 Cs source was used. The procedure is described in the EDMS document

2Yu. Guz 2013/12/04 Prior to the scan, all the 32 modules were checked with a pocket light (blue) and a microscope (Sergii Kandybei, KIPT Kharkiv, Ukraine). 2 cells with 1 broken fiber (out of 16) found (-6% in the light yield, not a problem). Module #31 has many cells with loose LED light input connectors – to be assigned to the non instrumented zone in the centre. The clear fiber (LED light guide) Preliminary checks

Yu. Guz 2013/12/043 The setup The standard xCAL control boards (communicated via SPECS) were used to set PMT HVs and measure DC anode currents.

Yu. Guz 2013/12/ Pos. 1 Pos. 2 Pos. 3 Pos ECAL module PMT module Each ECAL module was scanned in 4 positions; the PMT block was always in the same position. Only PMTs ##1,2,3,5 were used. The PMTs ##1 and 3 looked through all the corner cells; the PMT #2 – all the side cells, the PMT #5 – all the central cells, 4 times each. The module #32 (“reference”) was scanned twice, at the beginning and at the end (<5% difference). Total of 132 runs were performed during 5 days, Nov. Test procedure

Yu. Guz 2013/12/045 The shape is similar in all the cells. Difference at start and end because of different distance from the source (different shape of I(x) for an individual tile). No significant peculiarities in the I(x) were found in any cell. In what follows, the average current for the interval of 50<x<350 mm was taken as a measure of light yield. The I(t) shapes Cs

Yu. Guz 2013/12/046 Each corner cell was scanned twice, once with PMT #1 and once with #3. In figure: distribution of ratios of the two results for each corner cell (RMS/mean ≈ 2.3%). The accuracy (assuming that PMT#1 and #3 are equivalent) is 2.3% / √2 ≈ 1.6% Method’s accuracy 2.3% 0.7% Each central cell was scanned four times with the same PMT #5. In figure: distribution of ratios of each result to the average of the four ones. The accuracy is 0.7% * √(4/3) ≈ 0.8% The results are different: possible reasons can be difference in individual PMTs’ stability, mechanical positioning etc. In any case, this kind of accuracy is far enough for the purpose of inventory.

Yu. Guz 2013/12/047 All the cells showed rather similar light yield, max/min < 1.5. We can conclude that the light yield of all the cells is satisfactory. The difference in the light yield is most probably because of the optical contact with PMT (fiber polishing quality). Optionally, the least bright cells can be assigned to the non instrumented zone in the ECAL centre. Results