G. GiraudoGSI-Darmstadt 24-06-2013 MVD updates Thermal properties improvement Thermal properties improvement Cooling circuit test (Torino) Cooling circuit.

Slides:



Advertisements
Similar presentations
MVD A SSEMBLY T WO HALF FRAME DONE – D IMENSION T ESTED A NCILLARIES FOR F RAMES DONE – D IMENSION T ESTED F RAME A SSEMBLY & F INAL M ACHINING – MUST.
Advertisements

1 st Petal Prototype Fabrication completed October 27, 2008.
1 Thermal Modeling Syracuse University HEP Group Brian Maynard Steven Blusk.
The LHCb Inner Tracker LHCb: is a single-arm forward spectrometer dedicated to B-physics acceptance: (250)mrad: The Outer Tracker: covers the large.
M. Gilchriese Pixel Stave thermal/mechanical studies for Valencia Upgrade Workshop M. Gilchriese, M. Garcia-Sciveres, M. Cepeda LBNL W. Miller and W. Miller,
Feasibility Analysis h T1 T2 T3 T4 T5 One Dimensional Transient Analysis One Dimensional Finite Difference Steady State Analysis T1 and T5 will be known.
Heat Transfer Rates Conduction: Fourier’s Law
Pixel Upgrade Local Supports Based on Thermally Conducting Carbon Foam E. Anderssen, M. Cepeda, S. Dardin, M. Garcia-Sciveres, M. Gilchriese, N. Hartman,
1 Conceptual design adopts state-of-the-art silicon sensor techniques (compare ATLAS/CMS/ALICE inner tracker layers, BaBar tracking of B mesons). Design.
17/06/2010UK Valencia RAL Petals and Staves Meeting 1 DC-DC for Stave Bus Tapes Roy Wastie Oxford University.
CMS TRACKER STATUS REPORT Dimitri PandoulasCMS Week
Hybrid Integrated Circuit
M. Gilchriese Integrated Stave Mechanics/Cooling Backup ATLAS Upgrade Workshop Valencia December 2007 M. Cepeda, S. Dardin, M. Gilchriese, C. Haber and.
SPD Mechanics and Cooling Status of the activity in Padova Rosario Turrisi Contents: Calibration of Johansson measuring machine Cooling components Half-stave.
The ALICE Silicon Pixel Detector Gianfranco Segato Dipartimento di Fisica Università di Padova and INFN for the ALICE Collaboration A barrel of two layers.
E. Da Riva/M. Gomez Marzoa1 WG4 Meeting - 18th July 2012 Ultra-light carbon fiber structures: first test campaign Enrico DA RIVA (EN-CV-PJ) Manuel GOMEZ.
M. Gilchriese SLHC Pixel Local Supports Based on Thermally Conducting Carbon Foam E. Anderssen, M. Cepeda, S. Dardin, M. Garcia-Sciveres, M. Gilchriese,
ATLAS Calorimeter Argon Gap Convection Test Bed Brian Cuerden 24 Apr
, T. Tischler, CBM Collaboration Meeting, GSI Status MVD demonstrator: mechanics & integration T.Tischler, S. Amar-Youcef, M. Deveaux, D. Doering,
20 th June 20111Enrico Da Riva, V. Rao Project Request and Geometry constraints June 20 th 2011 Bdg 298 Enrico Da Riva,Vinod Singh Rao CFD GTK.
, T. Tischler, CBM Collaboration Meeting, Split Status MVD Demonstrator: System Integration T.Tischler, S. Amar-Youcef, M. Deveaux, D. Doering,
Mechanical Status of EUDET Module Marc Anduze – 05/04/07.
SCT Week 2 Oct 2002N.P. Hessey NIKHEF1 Status ATLAS SCT 2002 NIKHEF Contributions to ATLAS: Magnets – discussed by Frank Trigger DCS Muon MDT and alignment.
Thermal & Mechanical Support for Diamond Pixel Modules Justin Albert Univ. of Victoria Nov. 6, 2008 ATLAS Tracker Upgrade Workshop.
JCOV, 25 OCT 2001Thermal screens in ATLAS Inner Detector J.Godlewski EP/ATI  ATLAS Inner Detector layout  Specifications for thermal screens  ANSYS.
THE VACUUM BOX FOR COMPASS CRYOSTAT MUNICH 23/10/2007 G. GIRAUDO I.N.F.N. TORINO 1.MECHANICS – OVERWIEV 2.WINDOWS 3.INTEGRATION WITH HODOSCOPE.
Strip Stave cores Stephanie Yang ATLAS upgrade Oxford activities, January 2015.
W.O. Miller i T i VG 1 Two Pixel Configurations Under Study First: A Monolithic Integrated Structure First: A Monolithic Integrated Structure –Axial array.
Production of Petal Mechanics. Petal plates (EUROCOMPOSITE) to be made with T300 skins (+45°/-45°) Second skins (FVT) are M40 (0°/90°) and are available.
Marcello Lunardon - ALICE Gluing Meeting 010/03/2003 Study of glues for the assembly of the ALICE Silicon Pixel Detectors Status at The PADOVA.
Overview WG4 Meeting - 16th October 20121M. Gomez Marzoa, E. Da Riva Maximum ΔT admissible at cooling system T_1 T_2 T_1+0.5*ΔT Stave  If T_2 – T_1 =
22/04/20011Wire Chamber Working Group Status on O-ring closed Prototype Foam panels from Frascati (size: 279mm*341mm) No pad structure 4 independent gas.
STEADY HEAT CONDUCTION
12/3/2015R. Mountain, Syracuse University LHCb CO2 Cooling EDR2.
Pixel Upgrade Carbon Foam and Outer Stave Update E. Anderssen, M. Cepeda, M. Garcia-Sciveres, M. Gilchriese, T. Johnson, J. Silber Lawrence Berkelely National.
Thermal Model of Pixel Blade Conceptual Design C. M. Lei 11/20/08.
Walter Sondheim 6/9/20081 DOE – Review of VTX upgrade detector for PHENIX Mechanics: Walter Sondheim - LANL.
ATLAS Inner Detector thermal study. The Inner Detector.
K.W. Glitza University of Wuppertal IBL Stave (Lessons for Upgrade)
Thermal Screen Grounding CERN - Dec. 10 th, 2003 Enzo Carrone The thermal screen grounding and the tracker: a scary concert Enzo Carrone.
Marc Anduze – CALICE Meeting – KOBE 10/05/07 Mechanical R&D for Technological EUDET ECAL Prototype.
A hollow stave Ian Wilmut – August LBL stave At the March UG week LBL showed a prototype asymmetric stave. This prompted consideration of the strip.
E. Da Riva/M. Gomez Marzoa1 WG4 Meeting - 27th June 2012 Air Cooling by means of carbon fiber structure Enrico DA RIVA (EN-CV-PJ) Manuel GOMEZ MARZOA (EN-CV-PJ)
Stavelet 09 and Storage/Assembly/Survey Frame Progress Report Brookhaven National Laboratory David Lynn, Susan Duffin, Anatoly Gordeev, Ken Sexton Yale.
Pixel upgrade test structure: CO 2 cooling test results and simulations Nick Lumb IPN-Lyon MEC Meeting, 10/02/2010.
Eric Vigeolas, July the 3 rd Status The IBL detector construction already started and the components assembly (flex, modules, stave loagin) will.
Thermal jumble! (Action list review) C. Marinas IFIC-Valencia DEPFET-Valencia 1 Valencia
Experiences and Issues with Carbon Foam at BNL & Yale BNL: David Lynn, Marc-Andre Pleier, Anatoli Gordeev, Russ Burns, Ken Sexton Yale: Paul Tipton, Will.
XXXIX PANDA COLLABORATION MEETING GSI-DECEMBER 2011 B. GIRAUDO / D. ORECCHINI CENTRAL SUPPORT FRAME STRUCTURAL ANALYSIS FIRST APPROACH AND PRELIMINARY.
B [OT - Mechanics & Cooling] Stefan Gruenendahl February 2, 2016 S.Grünendahl, 2016 February 2 Director's Review -- OT: Mechanics &
BLIP capsule update Beryllium, Graphite, Titanium K. Ammigan
MVD COOLING STATUS-PAST AND UPDATES PIXEL COOLING PROJECT: -STUDIES and TEST on MATERIALS (Carbon Foam) -THERMAL FEM ANALYSES and TEST on DISKS and STAVES.
Marc Anduze – EUDET Meeting – PARIS 08/10/07 Mechanical R&D for EUDET module.
F.Bosi, M.Massa, 11 th Pisa Meeting on Advanced Detectors, May 2009 Development and Experimental Characterization of Prototypes for Low Material.
Stave thermal analysis Cooling connections CO2 warm Test
Date of download: 9/27/2017 Copyright © ASME. All rights reserved.
P. Sutcliffe Liverpool University
Feedback on transfer line sizing and flow calculations for UT
Toward a Reasoned Design.
Micro Vertex Detector of PANDA Status of Strip BARREL and DISC
MECHANICAL FRAME OF THE MVD
MVD Mechanics update EXTERNAL FRAME: NEW DESIGN
FEE COOLING UPDATE CGEM Workshop - IHEP - June 13th 2017
IBL Overview Darren Leung ~ 8/15/2013 ~ UW B305.
Micro Vertex Detector of PANDA Strip Detector
Antti Onnela CERN – EP – Detector Technologies group
WG4 – Progress report R. Santoro and A. Tauro.
The Stave Thermo-Conductivity QC Procedure Idea
Work packages status in Torino and perspectives
Tests on a dummy facet of PIX upgrade using CO2 cooling
Presentation transcript:

G. GiraudoGSI-Darmstadt MVD updates Thermal properties improvement Thermal properties improvement Cooling circuit test (Torino) Cooling circuit test (Torino) Integration (Jülich) Integration (Jülich)

G. GiraudoGSI-Darmstadt Updates for stave – Improvements for thermal properties Changes: carbon foam  carbon paper carbon foam  Rohacell 31 IG Thermagraph FGS PropertiesUnitData Thicknessmm0.03 Densityg/cm Thermal Conductivity Through Plane W/m·K1500 Thermal Conductivity Through Thickness W/m·K15 Poco Foam/HTC PropertiesUnitData Thicknessmm<25.4 Densityg/cm 3 0.6/0.9 Thermal Conductivity Through Plane W/m·K135/245 Thermal Conductivity Through Thickness W/m·K45/70 REFERENCE:

Position and detectors distribution of Layer 1 & Layer 2 UNCHANGED Rohacell Carbon Paper Thermal filler G. GiraudoGSI-Darmstadt

CARBON FOAM PROJECT ADVANTAGES: CF plane workable DRAWBACK: CF gluing uniformity CARBON PAPER PROJECT Carbon PaperCarbon Foam ADVANTAGES: minor Temperature; less material DRAWBACK: plane precision Si=0,1mm Glue=0,1mm CF=1mm Glue=0,1mm Ω=0,3mm Glue=0,1mm MP35N=0,08mm Si=0,1mm Glue=0,1mm MP35N=0,08mm Glue=0,1mm CP=0,05mm Glue=0,1mm Ω=0,3mm TEST ARE NEEDED Tmax=35°C Tmax=33°C

G. GiraudoGSI-Darmstadt Hydraulic circuit test – 2 lines First step – not remote controlled

G. GiraudoGSI-Darmstadt Central frame (Prototype) completed in Frascati last 15 th May Bosses for MVD suspension added Ready to be sent in Jülich a.s.a.p.

G. GiraudoGSI-Darmstadt