1 REGIONAL BIOTECH AT THE UNIVERSITY OF TEXAS-PAN AMERICAN BIOSCIENCE EDUCATION FOR THE RIO GRANDE VALLEY.

Slides:



Advertisements
Similar presentations
Measuring Volume Biotech I pg. 301 to 323 in Basic Laboratory Methods.
Advertisements

Use and Maintenance of Micropipets
Salk Institute Mobile Lab Gel Electrophoresis Student Instructions VWR Set up.
An Introduction to Microvolumetrics and Pipetting
Use and Maintenance of Micro-pipettes
Measuring Small Amounts Part 1: Using pipets and micropipets.
INTRODUCTION TO PIPETTES
Cautions! 1. Set pipet volume only within the range specified for that micropipet 2. Do not attempt to set a volume beyond the pipet’s minimum or maximum.
Oct. 22, 2012 Generosity Ludicrous: causing or deserving laughter because of absurdity Do Now: What is a microliter? How many microliter are in one liter?
How to Use a Micropipettor A micropipettor is a precision instrument – expensive (about $200 each), easily broken. Good technique will let it work for.
What are Micropipettors?! We will be using 3 different sizes of micropipettors: ◦ P20 ◦ P200 ◦ P1000 Very expensive and very fragile – USE Responsibly!!!
Micropipette Lab Comparing Precision and Accuracy!
Micropipette Tutorial
Pipette Calibration Procedure Pipette, water and balance Test the maximum volume or minimum volume Pre-wet tips Test 5 volumes per setting.
MLAB 1335 Immunology Serology Terry Kotrla, MS, MT(ASCP)BB
The Basic Skills of the Biotechnology Workplace
Measuring volumes which are what we scientists call “very, very small”
Introduction of CLS 333.  Course Description:  This is a required course in biochemistry for preparing a generalist in medical technology program. The.
Introduction to Equipment
Micropipette Tutorial From the Science Dept at SHS
MLAB 1335 Immunology Serology Terry Kotrla, MS, MT(ASCP)BB
Biochemistry Practical Dept.of Biochemistry Zhihong Li ( 李志红 )
Biochemistry Practical Dept.of Biochemistry Zhihong Li ( 李志红 ) PhD.
Micropipettes and Centrifuges Bio 9. Micropipettes are essential equipment in a modern biology lab For moving liquids from container to container Can.
Lab Techniques How to do a Manual Titration. Rinse the inside of the Burette Rinse the burette with 2-3 cm 3 of water then with 2-3 cm 3 the solution.
Micropipettes Step-by-Step to use Micropipettes 1) Check the volume 2) Attach disposable tip (different tips for each size micropipette) 3) Depress the.
Wildlife Forensics Environmental Study Center. Chinchilla.
CHAPTER 1: Some Tools of the Trade Lab Purpose of Lab 1.1 Become familiar with the small volumes of solutions used in molecular biology Introduce.
How to use a micropipette. When is a micropipette needed? Micropipettes are precision instruments designed to measure and transfer small volumes of liquids.
 Accurately measure and transfer small amounts of liquid  Volumes commonly range from 0.5 – 2000  L (1/millionth of a liter aka )  2-20  L.
1. Which tool would you use for picking up 15 microliter? Which tool for 25 ml? Why? 2. Why do the little test tubes look this way? 3. Answer “Micropipette.
Use of the Labnet Micropipettor. Purpose of the Pipettor Biotechnologists use a pipettor to transfer precise amounts of liquids from one container to.
Micropipettes Why they are useful How they work How to care for them.
Automatic pipettes use and calibration
TOOLS AND TECHNIQUES DNA Fingerprinting. Intoducing the microLiter! A TINY amount…a millionth of a Liter Very difficult to measure because it is SOOO.
Biotech 8/20/13 What pump would you use for a 1 or 2 ml pipet? What pump would you use for a 5 or 10 ml pipet?
Proper Micropipette Technique and Slide Preparation
Use and Maintenance of Micro-pipettes
An Introduction to Microvolumetrics and Pipetting
Automatic Pipettes Use And Calibration
Micropipette Tutorial
How to do a Manual Titration
Techniques in Molecular Biology 2017 Fall Lecture -2-
Measuring Volume.
MLAB 1335 Immunology Serology Terry Kotrla, MS, MT(ASCP)BB
مهارتك الأساسية في معامل التقنية الحيوية
Techniques in Molecular Biology 2017 Fall Lecture -2-
Measurement of Volume Chapter 20.
Use of the Labnet Micropipettor
Metric System and Lab Skills
Use and Maintenance of Micro-pipettes
Introduction To Medical Technology
(Examples of both horizontal and vertical windows are shown)
An Introduction to Microvolumetrics and Pipetting
How to do a Manual Titration
Micropipette Tutorial
Measuring volumes which are what we scientists call “very, very small”
Micropipettes.
How to Micropipette 1) Never adjust the volume below 5 uL or above 50uL 2) Never leave pipetter lying on bench with a tip attatched Basic Methods - Set.
Pipette Technique.
Restriction Enzymes.
Do Now How many ul (microliters) is in 1 liter?.
Using the micropipette
Grade Level: Middle School
Do Now How many ul (microliters) are in one liter?
Measurement & Micropipetting
Laboratory Glassware.
Pipette Calibration.
Sustainability by Biotechnology
Micropipette Tutorial
Presentation transcript:

1 REGIONAL BIOTECH AT THE UNIVERSITY OF TEXAS-PAN AMERICAN BIOSCIENCE EDUCATION FOR THE RIO GRANDE VALLEY

2 AN INTRODUCTION TO USING A DIGITAL MICROLITER PIPETTE PIPETMAN  & EAGLE  BRANDS

3 FUNCTION OF THE MICROLITER PIPETTE In the biotechnology laboratory, scientists use an instrument called a microliter pipette or micropipette to measure and transfer precise amounts of liquid reagents The micropipette is a precision instrument calibrated in microliters (  L). 1ml = 1000 (  L)

4 CAREFUL HANDLING OF THE MICROPIPETTE The micropipette must be handled with great care, to avoid damage. A damaged micropipette may produce imprecise measurements and this could affect the results from an experiment. Do not rough-handle or drop the micropipette

5 CAREFUL HANDLING OF THE MICROPIPETTE Do not adjust the micropipette volume above or below that recommended. If you encounter resistance while turning the volume adjustment wheel, stop and inform your instructor immediately. When not using the micropipette, lay it flat on the workbench or hang it on the pipette stand in front of you.

6 PARTS OF A MICROPIPETTE (EAGLE BRAND)

7 PARTS OF A MICROPIPETTE (PIPETMAN BRAND)

8 SETTING THE VOLUME ON THE P20 & E20 In the digital volume indicator window are three vertical numbers read from top to bottom The top number indicates “tens” microliters (  L) The middle number indicates “units” microliters (  L) The bottom number indicates “tenths” microliters (  L)

9 SETTING THE VOLUME ON THE P200 & E100 In the digital volume indicator window are three vertical numbers read from top to bottom The top number indicates “hundreds” microliters (  L) The middle number indicates “tens” microliters (  L) The bottom number indicates “units” microliters (  L)

10 SETTING THE VOLUME ON THE P1000 & E1000 In the digital volume indicator window are three vertical numbers read from top to bottom The top number indicates “thousands” microliters (  L) The middle number indicates “hundreds” microliters (  L) The bottom number indicates “tens” microliters (  L)

11 SETTING THE VOLUME ON THE MICROPIPETTE Hold the micropipette in one hand and with the other hand, turn the volume adjustment knob until the volume indicator displays the desired volume. See tables and pictures in the next slide for examples IF THE VOLUME ADJUSTMENT KNOB IS HARD TO TURN, STOP AND CALL THE INSTRUCTOR. DO NOT TRY TO FORCE THE KNOB TO TURN BECAUSE YOU WILL DAMAGE THE MICROPIPETTE

P20E20 TENS11 UNITS88 TENTHS33 THIS EXAMPLE IS A SETTING FOR 18.3 MICROLITERS (  L) P200E100 HUNDREDS11 TENS00 UNITS00 THIS EXAMPLE IS A SETTING FOR 100 MICROLITERS (  L) P1000E1000 THOUSANDS00 HUNDREDS88 TENS77 THIS EXAMPLE IS A SETTING FOR 870 MICROLITERS (  L)

13 MEASURING AND TRANSFERRING LIQUID REAGENTS Turn the volume adjustment knob to the desired volume Hold the micropipette so that the tip ejector button is facing the user and the thumb is free to depress the push button

14 MEASURING AND TRANSFERRING LIQUID REAGENTS Select and open a box containing the correct size tips to be used. Place the pointed end of the micropipette shaft into one of the tips and press down firmly, then lift-up the micropipette with tip attached. YOU MUST NEVER USE THE MICROPIPETTE WITHOUT A TIP ATTACHED !!!

15 MEASURING AND TRANSFERRING LIQUID REAGENTS Using your thumb, depress the pushbutton to the first stop. Immerse the micropipette tip about half-way into the reagent you are measuring. Make sure the reagent does not touch the micropipette shaft

16 MEASURING AND TRANSFERRING LIQUID REAGENTS With the pipette tip immersed in the reagent, draw the reagent into the tip by slowly raising your thumb and releasing the pushbutton Remove the tip from the reagent by lifting the micropipette Visually examine the tip to make sure it contains reagent and that there are no bubbles present.

17 MEASURING AND TRANSFERRING LIQUID REAGENTS Move the micropipette towards the transfer container which is to receive the measured reagent Expel the reagent inside the tip into the transfer container by placing the tip in the transfer container and slowly depressing the pushbutton with your thumb as far as it will go. With your thumb still holding down the depressed push button, lift the micropipette and tip out of the transfer container

18 MEASURING AND TRANSFERRING LIQUID REAGENTS With the micropipette and tip out of the transfer container, slowly raise your thumb, releasing the pushbutton. Position the micropipette on top of the waste container Dispose of the tip by using your thumb to press down on the tip ejector